BEGA 85195 Pole Top Luminaire Instruction Manual

June 1, 2024
BEGA

BEGA 85195 Pole Top Luminaire

Instructions for use

Application
Pole-top luminaire with symmetrical light distribution.
For mounting heights 3500 – 5000mm.

Dimensions

Dimensions
Dimensions

Dark Sky
The light from this luminaire is directed evenly and highly efficiently onto the surface to be illuminated. Less than 1% of the luminaire luminous flux is emitted into the upper half space of the luminaire.

Product description

Luminaire made of aluminium alloy, aluminium and stainless steel BEGA Unidure® coating technology Colour graphite Clear synthetic cover with optical structure Silicone gasket
Reflector made of pure anodised aluminium For pole top ø 76mm Slip fitter insert depth 60mm
Connecting cable X05BQ-F 4×1 mm²
Cable length 5m
BEGA Ultimate Driver®
Complies with flicker requirements in accordance with IEEE 1789, DIN IEC/TR 63158, DIN IEC/TR 61547-1 LED power supply unit 220-240 V 0/50-60 Hz
DC 176-264 V
DALI controllable
Number of DALI addresses: 1
A basic isolation exists between power cable and control line
BEGA Thermal Control®
Temporary thermal regulation to protect temperature-sensitive components without switching off the luminaire
Safety class II
Protection class IP 65
Dust-tight and protection against water jets
Impact strength IK10
Protection against mechanical
impacts < 20 joule
– Conformity mark
Weight: 4.6 kg
This product contains light sources of energy efficiency class(es) C

Safety

The installation and operation of this luminaire are subject to national safety regulations. Installation and commissioning may only be carried out by a qualified electrician.
The manufacturer accepts no liability for damage caused by improper use or installation. If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.

Overvoltage protection
The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547.
To achieve an additional protection against e.g. transients, etc. we recommend separate overvoltage protection components.
You can find them on our website at www.bega.com.

The ideal protection of all electronic components installed in the luminaires is achieved by using bounce-free switching contacts such as an electronic relay (solid-state relay), e.g. BEGA 71320.

Lamp
Module connected wattage 35.3 W
Luminaire connected wattage 38.5 W
Rated temperature ta=25 °C
Ambient temperature t max =35 °C

85 195K3
Module designation LED-0770/830
Colour temperature 3000 K
Colour rendering index CRI > 80
Module luminous flux 6675 lm
Luminaire luminous flux 3593 lm
Luminaire luminous efficiency 93,3 lm/W

Installation

Lead luminaire connecting cable into the pole and put on luminaire.
Align luminaire and fix it.
Fix lateral hexagon socket head screws M8 firmly.
Torque = 12Nm.

The electrical connection of the luminaire must be made with the appropriate protection class and safety class using suitable connection terminals (not included in the scope of delivery) on the luminaire power supply cable. We recommend you use BEGA connection boxes for this purpose.
Note correct configuration of the mains supply cable. The phase is connected to the brown wire (L) and the neutral conductor to the blue wire (N). The connection of the control cables is achieved by means of the both leads marked with DALI. In case these leads are not used the luminaire will be operated at full light output.

Cleaning · Maintenance
Clean luminaire regularly with solvent-free
cleansers from dirt and deposits.
Do not use high pressure cleaners.

Please note:

Do not remove the desiccant bag from the luminaire housing.
It is needed to remove residual moisture.

Replacement of the LED module

The designation of the LED module is noted on a separate label in the luminaire or on the underside of the specific LED module.
The light colour and light output of BEGA replacement modules correspond to those of the modules originally fitted.
The module can be replaced by qualified persons using standard tools.
Disconnect the electrical installation.
To open the luminaire undo the hexagon socket screws (wrench size 5 mm) in the luminaire top and lift off luminaire top.
LED-Netzteil austauschen.
In order to replace the LED module, the device holder also must first be removed from the luminaire housing.
Replace LED module, insert and secure the device holder.
Inspect and, if necessary, replace the luminaire gaskets.
Defective synthetic diffuser must be replaced.
Put on luminaire top and tighten the screws uniformly in crosswise fashion.
Torque = 3.7Nm.

Accessories

For this luminaire we recommend the following BEGA luminaire poles:

Tapered aluminium poles,
lacquered with access door and C-clamp

70 913 Pole with anch. section H 3500 mm
70 914 Pole with anch. section H 4000 mm
70 725 Pole with anch. section H 4500 mm
70 915 Pole with anch. section H 5000 mm
70 789 Pole with baseplate H 3500 mm
70 791 Pole with baseplate H 4000 mm
70 792 Pole with baseplate H 4500 mm
70 794 Pole with baseplate H 5000 mm

Cylindrically stepped aluminium poles lacquered · with door und C rail

70 901 Pole with anch. section H 4000 mm
70 903 Pole with anch. section H 5000 mm
70 900 Pole with baseplate H 4000 mm
70 902 Pole with baseplate H 5000 mm

Please see the instructions for use of the luminaire poles for suitable connection boxes.

Spares

Synthetic cover 15 000 824
LED power supply unit DEV-0270/1050i
LED module 3000 K LED-0770/830
Reflector 76 002 129
Gasket top 83 001 575

CUSTOMER SUPPORT

BEGA Gantenbrink-Leuchten KG ·
Postfach 3160 ·
58689 Menden ·
[email protected]·
www.bega.com
Symbol.png

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

BEGA User Manuals

Related Manuals