BEGA 51178.4 Table Lamp Instruction Manual
- June 1, 2024
- BEGA
Table of Contents
03.23
Technical amendments reserved
NEUE LEUCHTE
51 178.4
51178.4 Table Lamp
Table lamp for indoor use
Instructions for use
Application
Table lamp · indoor luminaire with metal housing and light-diffusing synthetic disks for shielded light, deflected upwards and downwards.
Product description
Table lamp »STUDIO LINE«
Metal housing, finish colour velvet black
Synthetic housing cover, finish colour velvet black inside hue matt brass
Light-diffusing synthetic disks with optical texture
Black connecting cable · 2 m, with in-line cord switch and Euro plug
BEGA Ultimate Driver®
Complies with flicker requirements in accordance with IEEE 1789, DIN IEC/TR
63158, DIN IEC/TR 61547-1
LED power supply unit 220-240 V y 50/60 Hz
BEGA Thermal Control® Temporary thermal regulation to protect temperature-
sensitive components without switching off the luminaire
Safety class II
**** – Conformity mark
Weight: 1.4 kg
This product contains light sources of energy efficiency class(es) D
Safety
The installation and operation of this luminaire are subject to national
safety regulations.
The manufacturer accepts no liability for damage caused by improper use or
installation.
If subsequent modifications are made to the luminaire, the person responsible
for these modifications shall be considered the manufacturer.
Overvoltage protection
The electronic components installed in the luminaire are protected against
overvoltage in accordance with DIN EN 61547.
To achieve an additional protection against e. g. transients, etc. we
recommend separate overvoltage protection components.
You can find them on our website at www.bega.com.
Lamp
Module connected wattage …………………….7.8 W
Luminaire connected wattage …………………….8.9 W
Rated temperature …………………………………..ta = 25 °C
Ambient temperature……………………. ta max= 40 °C
51 178.4 K3
Module designation
LED-1439/930 + LED-1440/930
Colour temperature………………………………….. 3000 K
Colour rendering index…………………………………. CRI > 90
Module luminous flux………………………………………. 1175 lm
Luminaire luminous flux……………………………………. 636 lm
Luminaire luminous efficiency ……………………… 71,5 lm / W
Installation
LED are high-quality electronic components!
Please avoid touching the light output opening of the LED directly during
installation or relamping.
Carefully remove the table lamp from its packaging and set it up. Make sure
that the luminaire is in a firm and secure position.![BEGA 51178.4 Table Lamp
- overview 2](https://manuals.plus/wp-content/uploads/2024/04/BEGA-51178.4
-Table-Lamp-overview-2.png)Place the housing shield provided on the
luminaire’s light-diffusing synthetic lenses.
Connect luminaire to socket (230 V).
To turn the luminaire on or off use the in-line cord switch.
Cleaning · Maintenance
Clean luminaire regularly with solvent-free cleansers from dirt.
Replacing the LED module
The designation of the LED module is noted on a label in the luminaire.
The light colour and light output of BEGA replacement modules correspond to
those of the modules originally fitted. The module can be replaced by
qualified persons using standard tools.
Disconnect the system and open the luminaire.
Please follow the installation instructions for the LED module.
Defective luminaire cover must be replaced.
Close the luminaire.
Spares
LED power supply unit | DEV-0451/350 |
---|---|
LED module 3000 K | LED-1439/930 |
LED module 3000 K | LED-1440/930 |
Housing shield | 75 005 780 |
BEGA Gantenbrink-Leuchten KG
Postfach 31 60 · 58689 Menden
info@bega.com
www.bega.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>