Specifications

  • Power Consumption of 85 021: 0.14 A
  • Lamp Module Connected Wattage: 24.1 W
  • Luminaire Connected Wattage: 27 W
  • Colour Temperature: 3000 K or 4000 K
  • Colour Rendering Index (CRI): > 90
  • Module Luminous Flux: 3350 lm or 3400 lm
  • Luminaire Luminous Flux: 2472 lm or 2509 lm
  • Luminaire Luminous Efficiency: 91.6 lm/W or 92.9 lm/W

Product Usage Instructions:

Safety
The installation and operation of this luminaire must comply with national safety regulations. The manufacturer is not liable for damages due to improper use or installation.

Installation

  1. Unscrew the hexagon socket screws on the sides of the connection adapter using a 3 mm wrench.
  2. Screw the corresponding accessory to the floodlight with a torque of 5 Nm.
  3. Plug the floodlight’s connecting cable into the appropriate plug contact with the mains plug, distribution box, or extension cable.
  4. Ensure the connecting cable length does not exceed 50 m per luminaire for low protective conductor resistance.
  5. To adjust beam direction, undo the joint screw using a 5 mm wrench, set desired direction, and tighten with a torque of 2.5 Nm.

Maintenance
Regularly check the connecting cable for external damage, and only replace it with the help of a qualified electrician.

FAQ

  • Q: Can I remove the desiccant bag from the luminaire housing?
    A: Do not remove the desiccant bag as it is necessary to remove residual moisture.

  • Q: Are overvoltage protection components necessary?
    A: The luminaire has overvoltage protection according to DIN EN 61547, but additional protection components are recommended for extra safety against transients.

  • Q: What accessories are available for fitting to floodlights with connection adapter?
    A: Accessories such as Shield, Cylindrical shield, and Exchangeable lens flat beam are available for fitting to floodlights with connection adapter.

Compact floodlight BEGA UniLink®

BEGA-85-021-UniLink-Compact-Floodlight- \(1\)

Instructions for use

Application
Compact floodlight BEGA UniLink® with connection adapter for use in combination with various accessories, e.g. for mounting on trees, pipes or wooden structures.
A separate mains plug must be ordered in order to connect the floodlight to the mains. The various country-specific mains plugs with 0.5 m connecting cable, as well as extension cables and five-way distribution boxes are available as accessories.

Product Description

  • Floodlight made of aluminium alloy,
  • aluminium and stainless steel
  • BEGA Unidure® coating technology
  • Colour graphite or silver
  • Clear safety glass
  • Reflector surface made of pure aluminium Rotation range of floodlight 360°
  • Swivel range -35°/+55°
  • 5 m mains supply cable
  • X05RN-F FEP 2 × 1@ + 1G2,5@ with
  • BEGA UniLink® plug-in connector
  • Complies with flicker requirements in accordance with IEEE 1789,
  • DIN IEC/TR 63158, DIN IEC/TR 61547-1
  • LED power supply unit
  • 220-240 V 50/60 Hz
  • BEGA Thermal Switch®
  • Temporary thermal shutdown to protect temperature-sensitive components
  • Safety class I
  • Protection class IP 65
  • Dust-tight and protection against water jets Impact strength IK07
  • Protection against mechanical
  • impacts < 2 joule
  • – Conformity mark
  • Weight: 2.2 kg
    This product contains light sources of energy efficiency class(es) E

Safety

The installation and operation of this luminaire are subject to national safety regulations.
The manufacturer accepts no liability for damage caused by improper use or installation. If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.

Total load
When configuring your lighting system, please ensure that the maximum power consumption of 6 A is not exceeded. Information on power consumption can be found in the instructions for use and data sheets for all BEGA UniLink® luminaires.
Power consumption of 85 021: 0,14 A

Lamp

  • Module connected wattage 24.1 W
  • Luminaire connected wattage 27 W
  • Rated temperature = 25 °C
  • Ambient temperature = 25 °C

85 021 K3

  • Module designation LED-0800/930
  • Colour temperature 3000 K
  • Colour rendering index CRI > 90
  • Module luminous flux 3350 lm
  • Luminaire luminous flux 2472 lm
  • Luminaire luminous efficiency 91,6 lm / W

85 021 K4

  • Module designation LED-0800/940
  • Colour temperature 4000 K
  • Colour rendering index CRI > 90
  • Module luminous flux 3400 lm
  • Luminaire luminous flux 2509 lm
  • Luminaire luminous efficiency 92,9 lm / W

Light technique

  • Symmetrical wide beam light distribution
  • Half beam angle 45°
  • The symmetrical light cone can be modified to resemble flat beam light distribution for special lighting applications by replacing the cover glass.

Overvoltage protection

  • The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547.
  • To achieve an additional protection against e. g. transients, etc. we recommend separate overvoltage protection components.
  • You can find them on our website at www.bega.com.

Caution
The BEGA UniLink® plug connectors may only be connected and disconnected in a voltage-free state.

Installation

Unscrew the hexagon socket screws (wrench size 3 mm) on the sides of the connection adapter and screw the corresponding accessory to the floodlight.
Torque = 5 Nm.
Plug the floodlight’s connecting cable into the plug contact of the connecting cable with the country-specific mains plug, or into the distribution box or extension cable.
To ensure a sufficiently low protective conductor resistance (loop resistance), the connecting cable of each luminaire in the system must not exceed a length of 50 m from the entry point.

Adjustment of beam direction:
Undo joint screw (hexagon socket head wrench size 5 mm) and set the desired beam direction.
Tighten the joint screw.
Torque = 2.5 Nm.

Please note
Do not remove the desiccant bag from the luminaire housing.
It is needed to remove residual moisture.

Cleaning · Maintenance

  • Clean luminaire regularly with solvent-free cleansers from dirt and deposits.
  • Do not use high pressure cleaners.

Maintenance
The connecting cable must be checked for external damage and may only be replaced by a qualified electrician.

Replacing the LED module

  • The designation of the LED module is noted on a label in the luminaire.
  • The light colour and light output of BEGA replacement modules correspond to those of the modules originally fitted. The replacement can be carried out by a qualified person using standard tools.
  • Disconnect the system from the power supply. Open the floodlight:
  • Loosen the back locking pin (hexagon socket wrench size 2 mm) in the trim ring.
  • Remove the trim ring along with the safety glass and reflector by twisting it anti-clockwise. Replace LED module.
  • Please follow the installation instructions for the LED module.
  • Inspect and, if necessary, replace the luminaire gaskets.
  • Defective glass must be replaced.
  • Place the trim ring with glass and reflector on the floodlight housing so that the notches in the trim ring and luminaire housing sit on top of each other.
  • Twist on the trim ring clockwise as far as the stop. Screw in the locking pin.

Accessories

The following combination options are available for fitting to floodlights with connection adapter:

  • 71 223 Screw clamp with connection adapter 71 224 Tube clamp with connection adapter 71 225 Lashing strap with connection adapter 71 226 General fastener with connection adapter
  • 71 227 G½ mount with connection adapter
  • 71 280 Shield
  • 71 285 Cylindrical shield
  • 71 290 Exchangeable lens flat beam Country-specific mains plugs with 0.5 m connecting cable
  • 71 180 Plug type F / E: system common in Germany and Europe
  • 71 181 Plug type G: system used in Great Britain (“Commonwealth plug”)
  • 71 182 Plug type J: system common in Switzerland and Liechtenstein
  • 71 183 Plug type L: system common in Italy and Greece
  • 71 184 Plug type K: system common in Denmark and Greenland
  • 71 186 BEGA UniLink® Extension cable 5 m 71 187 BEGA UniLink® Extension cable 10 m 71 188 BEGA UniLink® Extension cable 20 m
  • 71 247 Connecting cable 5 m  with free line ends
  • 71 256 Connecting cable 0.5 m with free line ends
  • 71 189 BEGA UniLink® Five-way distribution box

For the accessories a separate instructions for use can be provided upon request.

Spares

  • Trim ring graphite with glass 25 000 234
  • Trim ring silver with glass 25 000 235
  • LED power supply unit DEV-0352/700
  • LED module 3000 K LED-0800/930
  • LED module 4000 K LED-0800/940
  • Reflector 75 005 075
  • Gasket housing 83 002 022
  • Gasket glass 83 002 222

BEGA Gantenbrink-Leuchten KG · Postfach 31 60 · 58689 Menden · info@bega.com · www.bega.com