Specifications

Model Number| Furnace Efficiency| Stages of Heating| Motor Type| Heating Input (BTUH)| AC Max. Major Series Capacity| Width| Position| NOx| Controls| Minor Series Option Code
---|---|---|---|---|---|---|---|---|---|---
FR801V| 80.0%| Single Stage| Variable Speed Constant Torque (VS-CT)| 50,000 – 125,000 BTUH| 3 – 5 ton drive| 14″ – 24.5″| Upflow Horizontal| Standard or Low NOx| 1st Series or Premium Grade

Product Usage Instructions

Installation

  1. Ensure the furnace is not to be installed in mobile homes as it is not approved for such use.
  2. Follow the physical data and specifications provided for the specific model number.

Operation

  1. Connect the furnace to a gas supply line with a 1/2″ N.P.T. connection.
  2. Ensure the electrical requirements are met (115V, 60Hz, 1 Ph).

Maintenance

  1. Regularly clean or replace air filters to maintain optimal performance.
  2. Schedule annual professional maintenance to ensure safe and efficient operation.

FAQ (Frequently Asked Questions)

  • Is this furnace suitable for use in mobile homes?
    No, this furnace is not approved or recommended for use in mobile homes.

  • What type of motor does this furnace use?
    This furnace uses a Variable Speed Constant Torque (VS-CT) motor.

  • What is the heating capacity range of this furnace?
    The heating input ranges from 50,000 to 125,000 BTUH.

  • What is the AFUE (Annual Fuel Utilization Efficiency) of this furnace?
    The AFUE of this furnace is 80.0%.

Endeavor™ Line F-Series Gas Furnaces

FR801V

  • 80% A.F.U.E.†
  • EcoNet® Enabled
  • Heating Stages: Single Stage
  • Motor Type: Constant CFM
  • Input Rates: 50-125 kBTU [14.65-36.63 kW] Configuration Options: Up flow/Horizontal

A.F.U.E. (Annual Fuel Utilization Effi ciency) calculated in accordance with Department of Energy test procedures.
The Bluetooth® word mark and logos are registered trademarks owned by Bluetooth SIG, Inc. and any use of such marks by Rheem® is under license. Other trademarks and trade names are those of their respective owners.

Features and Benefits

  • PlusOne® Diagnostics: With the Friedrich® Contractor & EcoNet® Apps, built-in EcoNet® & Bluetooth® technology makes monitoring, troubleshooting and repairing the product easier than ever before
  • Dip Switch Free Installation Commissioning via Bluetooth®1 Technology: Seamless final install step without DIP switch configuration using the Friedrich Contractor App
  • PlusOne® Ignition System: Proven Direct Spark Ignition (DSI) for reliability and longevity
  • Constant CFM Motor: Truly variable speed technology allows for ultimate humidity control, quieter sound levels and year-round energy savings
  • Quieter Operation2: A fully insulated blower cabinet, solid bottom and truly variable speed airflow technology makes this furnace one of the quieter options available
  • EcoNet® Enabled Furnace: The latest in sensor technology and the EcoNet® monitoring system provides a new level of protection, control and energy savings
  • Allows on-the-go control and receipt of system alerts by the homeowner via the EcoNet® Smart Thermostat and EcoNet® App3
  1. The Bluetooth® word mark and logos are registered trademarks owned by Bluetooth SIG, Inc. and any use of such marks by Rheem® is under license. Other trademarks and trade names are those of their respective owners.
  2. Based on manufacturer’s furnace offering, and the product’s heating stages, motor type and cabinet insulation. Sound levels are also dependent on furnace location and installation.
  3. Wifi broadband internet connection required. Download the EcoNet® App from the App Store® or Google Play® to set up your EcoNet® Smart Thermostat. Receipt of notifications depend on home WiFi set up. Amazon, Alex and all related logos are trademarks of Amazon.com, Inc. or its affiliates.

Gas Furnaces

FRIEDRICH-FR801V-Endeavor-Line-F-Series-Gas-Furnaces-
01

[ ] Designates Metric Conversions

AVAILABLE MODELS

FR801V0503A14UHCAP
FR801V0504A17UH
CAP
FR801V0754A17UHCAP
FR801V0755A21UH
CAP
FR801V1005A21UHCAP
FR801V1255A24UH
CAP

* S = Standard, N = Low NOx

STANDARD EQUIPMENT

100% Safety Lock Out
29-4C Stainless Steel Secondary Heat Exchanger Design
Adjustable Cool Fan Off Delay
Aluminized steel primary heat exchanger design
Blower Compartment Door Safety Switch
Bluetooth® diagnostics
Bluetooth® setup
Bluetooth® setup and diagnostics
Completely assembled and wired
Direct Drive Motor
EcoNet® Thermostat Connections
Electronic On/Off Blower Time Control
Fully Insulated Heat Exchanger Cabinet
Humidistat Terminal Connection
Induced Draft Motor
Limit Controls
Low Speed Continuous Fan Option
Manual Shut-Off Valve
Marked condensate hoses
One Hour Automatic Retry
Power And Self-Test Diagnostics
Pressure Switch
PWM Controlled Constant Torque Electrically Commutated Blower Motor
Redundant Main Gas Control
Single Stage Heating Thermostat Connection
Solid Bottom
Blower Insulation
Two Plus* Stage Cooling Thermostat Connection

NOTE: A thermostat is not included as standard equipment *When Connected to Three Speed Or Modulating AC/HP Product

WARNING
THIS FURNACE IS NOT APPROVED OR RECOMMENDED FOR USE IN MOBILE HOMES

Physical Data and Specifications—Upflow Models

MODEL NUMBERS FR801V 1stg VS-CT UP/HZ SERIES| FR801V 0503A14UHCAP| FR801V 0504A17UHCAP| FR801V 0754A17UHCAP| FR801V 0755A21UHCAP| FR801V 1005A21UHCAP| FR801V 1255A24UHCAP
---|---|---|---|---|---|---
Input-BTU/Hr [kW]| 50,000 [15]| 50,000 [15]| 75,000 [22]| 75,000 [22]| 100,000 [29]| 125,000 [37]
Heating Capacity BTU/Hr [kW] G)| 40,000 [12]| 40,000 [12]| 60,000 [18]| 60,000 [18]| 80,000 [23]| 100,000 [29]
Blower (D x W) [mm]| 11 x 6 [279 x 152]| 11 x 7 [279 x 178]| 11 x 7 [279 x 178]| 11 x 7 [279 x 178]| 11 x 10 [279 x 254]| 11 x 10 [279 x 254]
Motor H.P. [W] Type| 1/2 [373] VS-CT(ECM)| 3/4 [560] VS-CT(ECM)| 3/4 [560] VS- CT(ECM)| 1 [746] VS-CT(ECM)| 3/4 [560] VS-CT(ECM)| 3/4 [560] VS-CT(ECM)
Min. Circuit Ampacity| 9| 13| 9| 15| 12| 12
Min. Overload Protection Device| 15| 15| 15| 20| 15| 15
Max. Overload Protection Device| 15| 20| 15| 25| 15| 15
Motor Full Load Amps| 6.1| 9.6| 9.6| 12.4| 9.6| 9.6
Heating CFM [L/s]| 960 [453]| 930 [439]| 1450 [684]| 1425 [673]| 1550 [732]| 1900 [897]
MAX Cooling CFM [L/s]| 1240 [585]| 1650 [779]| 1650 [779]| 1980 [934]| 1980 [934]| 1980 [934]
MIN Cooling CFM [L/s]| 300 [142]| 500 [236]| 500 [236]| 500 [236]| 500 [236]| 500 [236]
Fan CFM [L/s]| 600 [283]| 800 [378]| 800 [378]| 1000 [472]| 1000 [472]| 1000 [472]
Max. E.S.P. (In. W.C.) [kPa]| 1.0 [0.25]| 1.0 [0.25]| 1.0 [0.25]| 1.0 [0.25]| 1.0 [0.25]| 1.0 [0.25]
Temperature Rise Range °F [°C]| 25-55 [13.9-30.6]| 25-55 [13.9-30.6]| 25-55 [13.9-30.6]| 25-55 [13.9-30.6]| 35-65 [19.4-36.1]| 40-70 [23-39]
Approx. Shipping Weight (Lbs.) [kg]| 104.5 [47]| 110 [50]| 117.5 [53]| 135 [61]| 140 [64]| 143.5 [65]
AFUE @| 80.0%| 80.0%| 80.0%| 80.0%| 80.0%| 80.0%

NOTES: All models are 115V, 60HZ, 1 Ph. Gas connection size for all models is 1/2″ [13 mm] N.P.T.

  1. In accordance with D.O.E. test procedures.
  2. See Conversion Kit Index Form for high altitude derate.

*S=Standard, N=Low NOx
This furnace does not meet air district requirements of 14 ng/J NOx emissions limit, and thus is subject to a mitigation fee of up to $450.

This furnace is to be installed for propane firing only in air districts requiring 14 ng/J NOx emission limits. Operating in natural gas mode is in violation of these Rules.

[ ] Designates Metric Conversions

Dimensional Data
FR801V UH

Upflow Application

FRIEDRICH-FR801V-Endeavor-Line-F-Series-Gas-Furnaces-
\(1\) Dimensional Data: Upflow Model

MODEL FR801V-| ****

A

| ****

B

| ****

C

| ****

D

| ****

E

| ****

F

| MINIMUM CLEARANCE (IN.) [mm]
---|---|---|---|---|---|---|---
LEFT SIDE| RIGHT SIDE| BACK| TOP| FRONT| VENT
050314| 14        [356]| 1227/32 [326]| 105/8 [270]| G)| 111/2 [292]| 17/8 [48]| 0| 4 [102] @| 0| 1 [25]| 3 [76]| 6 [152] ®
050417/75417| 171/2 [445]| 1611/32 [415]| 123/8 [314]| G)| 15        [381]| 21/2 [64]| 0| 3 [76] @| 0| 1 [25]| 3 [76]| 6 [152] ®
075521/100| 21        [533]| 1927/32 [504]| 141/8 [359]| G)| 181/2 [470]| 21/2 [64]| 0| 0| 0| 1 [25]| 3 [76]| 6 [152] ®
125| 241/2 [622]| 2311/32 [593]| 157/8 [403]| G)| 22        [559]| 21/2 [64]| 0| 0| 0| 1 [25]| 3 [76]| 6 [152] ®

NOTES:

  1. May require a 3″ [76 mm] to 4″ [102 mm] or 3″ [76 mm] to 5″ [127 mm] adapter.
  2. May be 0″ [0 mm] with type B vent.
  3. May be 1″ [25 mm] with type B vent.

Furnaces must be vented in accordance with the National Fuel Gas Code, ANSI Z223.1 and in accordance with local codes.

Horizontal Application

FRIEDRICH-FR801V-Endeavor-Line-F-Series-Gas-Furnaces-
\(2\) FRIEDRICH-FR801V-Endeavor-Line-F
-Series-Gas-Furnaces- \(3\) WARNING
THIS FURNACE IS NOT APPROVED OR RECOMMENDED FOR INSTALLATION ON ITS BACK, WITH ACCESS DOORS FACING UPWARDS.

Dimensional Data: Horizontal Model

MODEL FR801V-| **A| ****B| ****C| ****D| ****E| ****F| MINIMUM CLEARANCE (IN.) [mm]
---|---|---|---|---|---|---|---
SUPPLY AIR SIDE| RETURN AIR SIDE| BACK| TOP| FRONT| VENT**
050314| 14        [356]| 1227/32 [326]| 105/8 [270]| 1| 111/2 [292]| 17/8 [48]| 4 [102]| 4 [102]| 0| 1 [25]| 3 [76]| 6 [152] 1
050417/75417| 171/2 [445]| 1611/32 [415]| 123/8 [314]| 1| 15        [381]| 21/2 [64]| 3 [76]| 3 [76]| 0| 1 [25]| 3 [76]| 6 [152] 1
075521/100| 21        [533]| 1927/32 [504]| 141/8 [359]| 1| 181/2 [470]| 21/2 [64]| 0| 0| 0| 1 [25]| 3 [76]| 6 [152] 1
125| 241/2 [622]| 2311/32 [593]| 157/8 [403]| 1| 22        [559]| 21/2 [64]| 0| 0| 0| 1 [25]| 3 [76]| 6 [152] 1

NOTES:

  1. May require a 3″ [76 mm] to 4″ [102 mm] or 3″ [76 mm] to 5″ [127 mm] adapter.
  2. May be 0″ [0 mm] with type B vent.
  3. May be 1″ [25 mm] with type B vent.

Furnaces must be vented in accordance with the National Fuel Gas Code, ANSI Z223.1 and in accordance with local codes.

TARGET GAS HEATING AIRFLOWS

| FR801V 0503A14UHCAP| FR801V 0504A17UHCAP| FR801V 0754A17UHCAP| FR801V 0755A21UHCAP| FR801V 1005A21UHCAP| FR801V 1255A24UHCAP
Factory High Heating CFM [L/s]| 960 [453]| 930 [439]| 1450 [684]| 1425 [673]| 1550 [732]| 1900 [897]
High Heat Side Return CFM [L/s]| 960 [453]| 930 [439]| 1450 [684]| 1425 [673]| 1380 [651]| 1900 [897]
High Heat Approx. ±7°F CFM| 864 [408]| 837 [395]| 1305 [616]| 1283 [606]| 1395 [658]| 1710 [807]
High Heat Approx. ±12°F CFM| 796 [376]| 772 [364]| 1204 [568]| 1183 [558]| 1287 [607]| 1577 [744]

  • S = Standard, N = Low NOx

BOTTOM RETURN FILTER RACK FOR UPFLOW APPLICATION: RXGF-CB
SIDE RETURN FILTER RACK: RXGF-CD

*FILTER RACK FILTER SIZES INCHES [mm]**

**MODEL| RXGF-CB (UPFLOW/ HORIZONTAL)| RXGF-CD (UPFLOW) SIDE RETURN**
FR801V050| 121/4 x 25| 153/4 x 25
[311 x 635]| [400 x 635]
FR801V0754A17| 153/4 x 25| 153/4 x 25
[400 x 635]| [400 x 635]
FR801V0754A21/| 191/4 x 25| 153/4 x 25
FR801V100| [489 x 635]| [400 x 635]
FR801V125| 223/4 x 25| 153/4 x 25
[578 x 635]| [400 x 635]

4″ FLUE ADAPTER: RXGW-C01

Indoor Coil Casings

MODEL NUMBER

RXBC-D14AI
RXBC-D17AI
RXBC-D21AI
RXBC-D21BI
RXBC-D24AI
| WARNING: IMPORTANT NOTICE
---|---
A SOLID METAL BASE PLATE (SEE TABLE) MUST BE IN PLACE WHEN
THE FURNACE IS INSTALLED WITH SIDE AIR RETURN DUCTS. FAILURE
TO INSTALL A BASE PLATE COULD CAUSE PRODUCTS OF COMBUSTION
TO BE CIRCULATED INTO THE LIVING SPACE AND CREATE POTENTIALLY
HAZARDOUS CONDITIONS.
FURNACE| SOLID| BASE| BASE
WIDTH IN. [mm]| BOTTOM KIT NO.| PLATE NO.| PLATE SIZE IN. [mm]
14     [356]| RXGB-D14| AE-61874-01| 115/8 x 239/16 [295 x 598]
171/2 [445]| RXGB-D17| AE-61874-02| 151/8 x 239/16 [384 x 598]
21     [533]| RXGB-D21| AE-61874-03| 185/8 x 239/16 [473 x 598]
241/2 [622]| RXGB-D24| AE-61874-04| 255/8 x 239/16 [651 x 598]

For High Altitudes:

  • OPTION CODE FOR HIGH ALTITUDE: U.S.
    None required for high altitudes.

  • HIGH ALTITUDE CONVERSION KITS: U.S.
    None required for high altitudes.
    80+ HIGH ALTITUDE INSTRUCTIONS

CAUTION: Always follow National Fuel Gas Code (NFGC) guidelines when converting for high altitudes.
High altitude option codes are not required for these models. How-ever, the burner orifice size needs to be recalculated and verified at elevations above 2000 ft. See Installation Instructions for more information.

Integrated Controls

EcoNet® is smart, technology that allows Heating and Cooling, products to communicate with each other on one integrated network.

THE ECONET® SMART THERMOSTAT BUILT-IN WIFI

  • 4.3″ LCD TOUCH SCREEN
  • LOCAL WEATHER – Current conditions plus 6-day forecast
  • 5 OPERATING MODES – Heat, Cool, Auto, Emergency Heat and Fan Only
  • 7-DAY PROGRAMMABLE SCHEDULE – Offers comfort without thought
  • ONE-TOUCH AWAY – Quickly switch to your energy-saving away preferences
  • VACATION SCHEDULING – Allows you to save while you’re away and come home to comfort
  • STANDBY SCREEN – Displays indoor temperature and current weather

OPERATIONAL FEATURES

  • AUTOMATIC CHANGEOVER – Transitions between heating and cooling automatically to keep the house comfortable
  • INTEGRATED WATER CONTROL – Enables easy water heater management
  • SMOOTH ARRIVAL – Prompts the system to start ahead of schedule to ensure the home is at the desired temperature at the scheduled time
  • HUMIDITY CONTROL – Supports humidifier accessories or over-cool based dehumidification
  • DETAILED OPERATING STATUS – View pertinent equipment status information and run times
  • CONTINUOUS FAN – Offers 5 speeds (Low, Medium Low, Medium, Medium High, High)
  • SHORT-CYCLE PROTECTION – Avoids damage to equipment from short run cycles

MONITORING & REMOTE CONTROL FEATURES

  • ACTIVE MONITORING – Alerts to problems that need immediate attention
  • REMOTE CONTROL – Allows adjusting of comfort and settings from anywhere using a mobile device
  • SERVICE ALERTS – Sends routine maintenance reminders
  • AIR FILTER MONITORING – Detects when it’s time to replace the air filter
  • ALARM HISTORY – Displays time-stamped alarm codes with clear descriptions

GENERAL TERMS OF LIMITED WARRANTY*

Friedrich® will furnish a replacement for any part of this product which fails in normal use and service within the applicable period stated, in accordance with the terms of the limited warranty.
*For complete details of the Limited and Conditional Warranties, including applicable terms and conditions, contact your local contractor or the Manufacturer for a copy of the product warranty certifi cate.

Conditional Parts

  • (Registration Required) ……………………………Ten (10) Years
  • Heat Exchanger ………………………………..Twenty (20) Years

Before proceeding with installation, refer to installation instructions packaged with each model, as well as complying with all Federal, State, Provincial, and Local codes, regulations, and practices.

© 2023 Rheem Manufacturing Company. Friedrich trademarks owned by Rheem Manufacturing Company.
In keeping with its policy of continuous progress and product improvement, Friedrich reserves the right to make changes without notice.

Friedrich • 5600 Old Greenwood Road
Fort Smith, Arkansas 72908 • www.friedrich.com
PRINTED IN U.S.A. 7/23 QG FORM NO. GFR-663

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

FRIEDRICH User Manuals

Related Manuals