- Cooling Efficiencies up to: 15.2 SEER2/9.8 EER2
- Nominal Sizes: 2 to 5 Ton [7.0 to 17.6 kW]
- Cooling Capacities: 22.8 to 56.0 kBTU [6.68 to 16.4 kW]
- FORM NO. AFR-336
Features and Benefits
- 3-speed operation when installed with a 24V two-stage thermostat
- Provides precise temperature control, advanced humidity control, and greater efficiency
Model Number Identification Brand| Product Category| SEER2| Region|
Refrigerant Capacity BTU/HR| Major Series| Voltage| Type| Controls| Minor
Series
---|---|---|---|---|---|---|---|---|---
A| All| 15 – 15.2 SEER2| Z – R-410A| 24 – 24,000 [7.03 kW] 36 – 36,000 [10.55
kW] 48 – 48,000 [14.07
kW] 60 – 60,000 [17.58 kW]| A – 1st Design| J – 1ph, 208-230/60| 3 – 3+ Stage|
C – Communicating| A – 1st Design
General Data Model No.| Nominal Tonnage| Valve Connections| Number of
blades| Motor hp| CFM| RPM| watts
---|---|---|---|---|---|---|---
FRA15AZ24AJ3| 2.0| 3/8| 3/4| 91| 11.79| —| 0.276 1 24
FRA15AZ36AJ3| 3.0| 3/8| 7/8| 119| 14.4| —| 0.276 1 24
FRA15AZ48AJ3| 4.0| 3/8| 7/8| 130| 16.42| —| 0.276 1 24
FRA15AZ60AJ3| 5.0| 3/8| 7/8| 154| 17.88| —| 0.276 1 24
Electrical Data
- Line Voltage Data (Volts-Phase-Hz): 208/230-1-60
- Rated load amps: 10 (FRA15AZ24AJ3), 15 (FRA15AZ36AJ3), 20 (FRA15AZ48AJ3), 25 (FRA15AZ60AJ3)
- Locked rotor amps: 65 (FRA15AZ24AJ3), 70 (FRA15AZ36AJ3), 96 (FRA15AZ48AJ3), 119 (FRA15AZ60AJ3)
Accessories Model No.| Compressor crankcase heater*| Low ambient control|
Compressor sound cover| Low-pressure control| High-pressure control| Liquid
Line Solenoid (24 VAC, 50/60 Hz)| Solenoid Valve Solenoid Coil| Liquid Line
Solenoid (120/240 VAC, 50/60 Hz)| Solenoid Valve Solenoid Coil
---|---|---|---|---|---|---|---|---|---
FRA15AZ24AJ3| N/A| 47-102709-10| 68-23427-27| 47-103454-01| 47-103669-02|
200RD2T3TVLC| 61-AMG24V| 200RD2T3TVLC| 61-AMG120/240V
FRA15AZ36AJ3| N/A| 47-102709-10| 68-23427-28| 47-103454-01| 47-103669-02|
200RD2T3TVLC| 61-AMG24V| 200RD2T3TVLC| 61-AMG120/240V
FRA15AZ48AJ3| N/A| 47-102709-10| 68-23427-29| 47-103454-01| 47-103669-02|
200RD2T3TVLC| 61-AMG24V| 200RD2T3TVLC| 61-AMG120/240V
FRA15AZ60AJ3| N/A| 47-102709-10| 68-23427-29| 47-103454-01| 47-103669-02|
200RD2T3TVLC| 61-AMG24V| 200RD2T3TVLC| 61-AMG120/240V
Weighted Sound Power Level (dBA) Unit Size Voltage, Series| Standard
Rating (dBA)| Low Speed/ High Speed
---|---|---
FRA15AZ24AJ3| 71.7| 35.9, 47.9, 55.3, 53.2, 50.4, 47.1, 43.8
FRA15AZ36AJ3| 72.9| 38.5, 48.0, 53.8, 49.2, 45.9, 47.0, 47.4
FRA15AZ48AJ3| 76.2| 42.3, 45.9, 53.5, 48.9, 45.8, 59.1, 36.4
FRA15AZ60AJ3| 76.7| 39.7, 49.0, 58.2, 54.5, 52.2, 53.8,
Features and Benefits
- EcoNet® Enabled: Automatic system configuration and optimization
- PlusOne® Diagnostics & Bluetooth®1 Connectivity: With the Friedrich® Contractor & EcoNet® Apps, built-in technology makes advanced set-up, monitoring, troubleshooting, and repairing the product easier than ever before
- PlusOne® Variable Speed Twin Rotary Compressor & Inverter Drive:
- Features Inverter operation from 40 to 70% capacity or 100% capacity via line voltage with the EcoNet® Smart Thermostat
- 3-speed operation when installed with a 24V two-stage thermostat
- Provides precise temperature control, advanced humidity control, and greater efficiency
- Swept Wing Fan Technology: Features quieter operation and improved unit acoustics
- 7mm Condenser Copper Coil: Requires less refrigerant allowing for a smaller and lighter footprint while enhancing reliability
- P lusOne® Expanded Value Space: 3 in. – 4 in. – 5 in. service valve space—provides a minimum working area of 27 square inches for easier access
- PlusOne® Triple Service Access: 15 in. wide, industry leading corner service access, two fasteners, removable corner, and individual louver panels–makes repairs easier and faster
Air Conditioners
- FR – Friedrich® A – Air Conditioners 15 – 15.2 SEER2 A – All Z – R-410A 24 – 24,000 [7.03 kW] A – 1st Design J – 1ph, 208-230/60 3 – 3+ Stage C – Communicating A – 1st Design
- 36 – 36,000 [10.55 kW]
- 48 – 48,000 [14.07 kW]
- 60 – 60,000 [17.58 kW]
Designates Metric Conversions
Available Models | Description |
---|---|
FRA15AZ24AJ3CA | Endeavor™ Line F-Series Plus 2 ton EcoNet® Enabled 3+ Speed |
iM Air Conditioner – 208/230/1/60
FRA15AZ36AJ3CA| Endeavor™ Line F-Series Plus 3 ton EcoNet® Enabled 3+ Speed
iM Air Conditioner – 208/230/1/60
FRA15AZ48AJ3CA| Endeavor™ Line F-Series Plus 4 ton EcoNet® Enabled 3+ Speed
iM Air Conditioner – 208/230/1/60
FRA15AZ60AJ3CA| Endeavor™ Line F-Series Plus 5 ton EcoNet® Enabled 3+ Speed
iM Air Conditioner – 208/230/1/60
Standard Equipment
R-410A Refrigerant
Variable Speed Twin Rotary Compressor
Field Installed Filter Drier
Front Seating Service Valves
Internal Pressure Relief Valve
Internal Thermal Overload
Long Line capability
Low Ambient capability with Kit
3-4-5 Expanded Valve Space
Composite Basepan
2 Screw Control Box Access
15″ Access to Internal Components
Quick-release louver panel design
No fasteners to remove along the bottom
Optimized Venturi Airflow
Single-row condenser coil
Powder coated paint
Rust resistant screws
QR code
External gauge ports
Service trays
General Data
Model No.| FRA15AZ24AJ3| FRA15AZ36AJ3| FRA15AZ48AJ3|
FRA15AZ60AJ3
Nominal Tonnage| 2.0| 3.0| 4.0| 5.0
Valve Connections|
Liquid Line O.D. – in.| 3/8| 3/8| 3/8| 3/8
Suction Line O.D. – in.| 3/4| 3/4| 7/8| 7/8
Refrigerant (R410A) furnished oz.¹| 91| 119| 130| 154
Compressor Type| Twin Rotary
Outdoor Coil|
Net face area – Outer Coil| 11.79| 14.4| 16.42| 17.88
Net face area – Inner Coil| —| —| —| —
Tube diameter – in.| 0.276| 0.276| 0.276| 0.276
Number of rows| 1| 1| 1| 1
Fins per inch| 24| 24| 24| 24
Outdoor Fan|
Diameter – in.| 20| 24| 24| 26
Number of blades| 3| 3| 3| 3
Motor hp| 1/5| 1/5| 1/3| 1/2
CFM| 2908| 4138| 4529| 5274
RPM| 1075| 1000| 1075| 1075
watts| 170| 267| 294| 370
Shipping weight – lbs.| 174| 198| 230| 251
Operating weight – lbs.| 167| 191| 223| 244
Electrical Data
Line Voltage Data (Volts-Phase-Hz)| 208/230-1-60| 208/230-1-60|
208/230-1-60| 208/230-1-60
Maximum overcurrent protection (amps)²| 20| 30| 40| 50
Minimum circuit ampacity³| 12| 20| 25| 32
Compressor|
Rated load amps| 10| 15| 20| 25
Locked rotor amps| 65| 70| 96| 119
- Refrigerant charge sufficient for 15 ft. length of refrigerant lines. For longer line set requirements see the installation instructions for information about set length and additional refrigerant charge required.
- HACR type circuit breaker of the fuse.
- Refer to the National Electrical Code manual to determine wire, fuse, and disconnect size requirements.
Accessories
Model No.| FRA15AZ24AJ3| FRA15AZ36AJ3| FRA15AZ48AJ3|
FRA15AZ60AJ3
---|---|---|---|---
Compressor crankcase heater*| N/A| N/A| N/A| N/A
Low ambient control| 47-102709-10| 47-102709-10| 47-102709-10| 47-102709-10
Compressor sound cover| 68-23427-27| 68-23427-28| 68-23427-29| 68-23427-29
Low-pressure control| 47-103454-01| 47-103454-01| 47-103454-01| 47-103454-01
High-pressure control| 47-103669-02| 47-103669-02| 47-103669-02| 47-103669-02
Liquid Line Solenoid (24 VAC, 50/60 Hz)| Solenoid Valve| 200RD2T3TVLC|
200RD2T3TVLC| 200RD2T3TVLC| 200RD2T3TVLC
Solenoid Coil| 61-AMG24V| 61-AMG24V| 61-AMG24V| 61-AMG24V
Liquid Line Solenoid (120/240 VAC, 50/60 Hz)| Solenoid Valve| 200RD2T3TVLC|
200RD2T3TVLC| 200RD2T3TVLC| 200RD2T3TVLC
Solenoid Coil| 61-AMG120/240V| 61-AMG120/240V| 61-AMG120/240V| 61-AMG120/240V
- Crankcase Heater recommended with Low Ambient Kit.
Weighted Sound Power Level (dBA)
Unit Size – Voltage, Series| Standard Rating (dBA) Low Speed/ High
Speed| TYPICAL OCTAVE BAND SPECTRUM (dBA without tone adjustment)|
Sound Power Level [dB(A)] with Sound Blanket
---|---|---|---
125| 250| 500| 1000| 2000| 4000| 8000
FRA15AZ24AJ3| 63.3| 35.9| 47.9| 55.3| 53.2| 50.4| 47.1| 43.8| ****
Sound Blankets – Standard
71.7| 46.1| 59.1| 63.2| 60.8| 58.7| 56.5| 47.9
FRA15AZ36AJ3| 61.4| 38.5| 48.0| 53.8| 49.2| 45.9| 47.0| 47.4
72.9| 47.5| 59.5| 64.9| 60.7| 62.6| 57.0| 49.6
FRA15AZ48AJ3| 63.8| 42.3| 45.9| 53.5| 48.9| 45.8| 59.1| 36.4
76.2| 49.4| 61.4| 68.1| 53.9| 60.8| 57.4| 48.5
FRA15AZ60AJ3| 65.7| 39.7| 49.0| 58.2| 54.5| 52.2| 53.8| 41.3
76.7| 49.3| 64.6| 68.1| 65.1| 62.6| 58.6| 53.0
NOTE: Tested in accordance with AHRI Standard 270-08 (not listed in AHRI)
Unit Dimensions
Model No.
| Operating| Shipping
---|---|---
H (Height)| L (Length)| W (Width)| H (Height)| L
(Length)| W (Width)
Inches| mm| Inches| mm| Inches| mm| Inches|
mm| Inches| mm| Inches| mm
FRA15AZ24AJ3| 27.00| 686| 29.75| 756| 29.75| 756| 28.50| 724| 32.38| 822|
32.38| 822
FRA15AZ36AJ3| 27.00| 686| 33.75| 857| 33.75| 857| 28.50| 724| 36.38| 924|
36.38| 924
FRA15AZ48AJ3| 31.00| 787| 33.75| 857| 33.75| 857| 32.50| 826| 36.38| 924|
36.38| 924
FRA15AZ60AJ3| 31.00| 787| 35.75| 908| 35.75| 908| 32.50| 826| 38.38| 975|
38.38| 975
Designates Metric Conversions
CLEARANCES
Control Wiring
Application Guidelines
- Intended for outdoor installation with free air inlet and outlet. The outdoor fan external static pressure available is less than 0.01 -in. WC.
- The minimum outdoor operation air temperature for a cooling mode without a low-ambient operation accessory is 55°F (12.8°C).
- Maximum outdoor operating air temperature is 125°F (51.7°C).
- For reliable operation, the unit should be level in all horizontal planes.
- Use only copper wire for electric connections at the unit. Aluminum and clad aluminum are not acceptable for the type of connector provided.
- Do not apply capillary tube indoor coils to these units.
- Factory-supplied filter drier must be installed.
Refrigerant Line Size Information
15/16 SEER2 Variable Speed Air Conditioners
Unit Size
| ****
Allowable Liquid Line Size
| ****
Allowable Vapor Line Size
| Outdoor Unit ABOVE or BELOW Indoor Unit Equivalent Length (Feet)
< 25| 26-50| 51-75| 76-100| 101-125| 126-150
Maximum Vertical Separation / Capacity Multiplier
2.0 Ton
**SEE NOTE 3
| 1/4″| 5/8″| 25/1.00| 50/0.99| 32/0.98| 40/0.97| NR| NR
5/16″| 5/8″| 25/1.00| 50/0.99| 50/0.98| 50/0.97| 50/0.96| 50/0.95
3/8″| 5/8″| 25/1.00| 50/0.99| 50/0.98| 50/0.97| 50/0.96| 50/0.95
1/4″| 3/4″| 25/1.00| 50/1.00| 32/0.99| 40/0.99| NR| NR
5/16″| 3/4″| 25/1.00| 50/1.00| 50/0.99| 50/0.99| 50/0.99| 50/0.98
3/8″| 3/4″**| 25/1.00| 50/1.00| 50/0.99| 50/0.99| 50/0.99| 50/0.98
3 Ton
| 5/16″| 5/8″| 25/0.99| 50/0.97| 50/0.95| 50/0.93| 37/0.91| NR
3/8″| 5/8″| 25/0.99| 50/0.97| 50/0.95| 50/0.93| 50/0.91| NR
5/16″| 3/4″| 25/1.00| 50/0.99| 50/0.99| 50/0.98| 37/0.97| 22/0.96
3/8″| 3/4″| 25/1.00| 50/0.99| 50/0.99| 50/0.98| 50/0.97| 50/0.96
1/2″| 3/4″| 25/1.00| 50/0.99| 50/0.99| 50/0.98| 50/0.97| 50/0.96
4 Ton
| 3/8″| 3/4″| 25/0.99| 50/0.98| 50/0.97| 50/0.96| 50/0.94| 50/0.93
1/2″| 3/4″| 25/0.99| 50/0.98| 50/0.97| 50/0.96| 50/0.94| 50/0.93
3/8″| 7/8″| 25/1.00| 50/0.99| 50/0.99| 50/0.98| 50/0.98| 50/0.97
1/2″| 7/8″| 25/1.00| 50/0.99| 50/0.99| 50/0.98| 50/0.98| 50/0.97
5 Ton
| 3/8″| 3/4″| 25/0.99| 50/0.97| 50/0.95| 50/0.93| 50/0.91| NR
1/2″| 3/4″| 25/0.99| 50/0.97| 50/0.95| 50/0.93| 50/0.91| NR
3/8″| 7/8″| 25/1.00| 50/0.99| 50/0.98| 50/0.98| 50/0.97| 38/0.96
1/2″| 7/8″| 25/1.00| 50/0.99| 50/0.98| 50/0.98| 50/0.97| 50/0.96
NOTES:
- Do not exceed 150 ft. linear line length.
- Do not exceed 50 ft. vertical separation between indoor and outdoor units.
- A 3/4″ suction line should only be used for 2-ton systems if the outdoor unit is below or at the same level as the indoor unit to ensure proper oil return.
- Always use the smallest liquid line allowable to minimize refrigerant charge.
- Applications shaded in light gray indicate capacity multipliers between 0.90 and 0.96 which are not recommended but are allowed.
- Applications shaded in dark gray are not recommended due to excessive liquid or suction pressure drop.
Refrigerant Line Size Information
15/16 SEER2 Variable Speed Air Conditioners
Unit Size
| ****
Allowable Liquid Line Size
| ****
Allowable Vapor Line Size
| Outdoor Unit ABOVE or BELOW Indoor Unit Equivalent Length (Meters)
< 25| 26-50| 51-75| 76-100| 101-125| 126-150
Maximum Vertical Separation / Capacity Multiplier
2.0 Ton
**SEE NOTE 3
| 6.35 [1/4]| 15.88 [5/8]| 8/1.00| 15/0.99| 10/0.98| 10/0.97| NR| NR
7.94 [5/16]| 15.88 [5/8]| 8/1.00| 15/0.99| 15/0.98| 15/0.97| 15/0.96| 15/0.95
9.53 [3/8]| 15.88 [5/8]| 8/1.00| 15/0.99| 15/0.98| 15/0.97| 15/0.96| 15/0.95
6.35 [1/4]| 19.05 [3/4]| 8/1.00| 15/0.99| 10/0.99| 12/0.99| NR| NR
7.94 [5/16]| 19.05 [3/4]| 8/1.00| 15/0.99| 15/0.99| 15/0.99| 15/0.99|
15/0.98
9.53 [3/8]| 19.05 [3/4]**| 8/1.00| 15/0.99| 15/0.99| 15/0.99| 15/0.99| 15/0.98
3 Ton
| 7.94 [5/16]| 15.88 [5/8]| 8/0.99| 15/0.97| 15/0.95| 15/0.93| 11/0.91| NR
9.53 [3/8]| 15.88 [5/8]| 8/0.99| 15/0.97| 15/0.95| 15/0.93| 15/0.91| NR
7.94 [5/16]| 19.05 [3/4]| 8/1.00| 15/0.99| 15/0.99| 15/0.98| 11/0.97| 7/0.96
9.53 [3/8]| 19.05 [3/4]| 8/1.00| 15/0.99| 15/0.99| 15/0.98| 15/0.97| 15/0.96
12.7 [1/2]| 19.05 [3/4]| 8/1.00| 15/0.99| 15/0.99| 15/0.98| 15/0.97| 15/0.96
4 Ton
| 9.53 [3/8]| 19.05 [3/4]| 8/0.99| 15/0.98| 15/0.97| 15/0.96| 15/0.94| 15/0.93
12.7 [1/2]| 19.05 [3/4]| 8/0.99| 15/0.98| 15/0.97| 15/0.96| 15/0.94| 15/0.93
9.53 [3/8]| 22.23 [7/8]| 8/1.00| 15/0.99| 15/0.99| 15/0.98| 15/0.98| 15/0.97
12.7 [1/2]| 22.23 [7/8]| 8/1.00| 15/0.99| 15/0.99| 15/0.98| 15/0.98| 15/0.97
5 Ton
| 9.53 [3/8]| 19.05 [3/4]| 8/0.99| 15/0.97| 15/0.95| 15/0.93| 15/0.91| NR
12.7 [1/2]| 19.05 [3/4]| 8/0.99| 15/0.97| 15/0.95| 15/0.93| 15/0.91| NR
9.53 [3/8]| 22.23 [7/8]| 8/1.00| 15/0.99| 15/0.98| 15/0.98| 15/0.97| 12/0.96
12.7 [1/2]| 22.23 [7/8]| 8/1.00| 15/0.99| 15/0.98| 15/0.98| 15/0.97| 15/0.97
NOTES:
- Do not exceed 46 meters of linear line length.
- Do not exceed 15 meters of vertical separation between indoor and outdoor units.
- 19.05mm [3/4 in.] vapor line should only be used for 2-ton systems if the outdoor unit is below or at the same level as the indoor unit to assure proper oil return.
- Always use the smallest liquid line allowable to minimize refrigerant charge.
- Applications shaded in light gray indicate capacity multipliers between 0.90 and 0.96 which are not recommended but are allowed.
- Applications shaded in dark gray are not recommended due to excessive liquid or suction pressure drop.
Additional Oil, Oz.
Lineset Length| 50| 60| 70| 80| 90| 100|
110| 120| 130| 140| 150
2T| N/A| N/A| N/A| N/A| N/A| 1| 2| 3| 5| 6| 7
3T| N/A| N/A| N/A| N/A| N/A| N/A| 1| 2| 3| 5| 6
4T| N/A| N/A| N/A| N/A| N/A| N/A| N/A| N/A| N/A| N/A| N/A
5T| N/A| N/A| N/A| N/A| N/A| N/A| N/A| N/A| N/A| N/A| N/A
Performance Data @ AHRI Standard Conditions – Cooling
Designated Tested Combination (DTC)
Outdoor Unit| Air Handler| Total Capacity BTU/H [kW]|
Net Sensible BTU/H [kW]| Net Latent BTU/H [kW]| SEER2|
EER2| Indoor CFM [L/s]
FRA15AZ24AJ3| FRH3VZ2417STACN| 22,800 [6.7]| 17,600 [5.2]| 5,200 [1.5]| 15.2|
9.8| 750 [354.0]
FRA15AZ36AJ3| FRH3VZ3617STACN| 34,200 [10.0]| 26,600 [7.8]| 7,600 [2.2]| 15.2|
9.8| 1,125 [530.9]
FRA15AZ48AJ3| FRH3VZ4821STACN| 45,500 [13.3]| 35,500 [10.4]| 10,000 [2.9]|
15.2| 9.8| 1,425 [672.5]
FRA15AZ60AJ3| FRH3VZ6024STACN| 55,500 [16.3]| 43,000 [12.6]| 12,500 [3.7]|
15.2| 9.8| 1,675 [790.5]
NOTE: This data includes DTC (Designated Test Combination) ratings and is for reference purposes only. A full listing of official ratings and system match-ups, along with downloadable certificates, can be accessed from the AHRI website: www.ahridirectory.org.
Integrated Controls
EcoNet® is smart, technology that allows Heating and Cooling, products to communicate with each other on one integrated network.
THE ECONET® SMART THERMOSTAT
- BUILT-IN WIFI
- 4.3″ LCD TOUCH SCREEN
- LOCAL WEATHER – Current conditions plus 6-day forecast
- 5 OPERATING MODES – Heat, Cool, Auto, Emergency Heat and Fan Only
- 7-DAY PROGRAMMABLE SCHEDULE – Offers comfort without thought
- ONE-TOUCH AWAY – Quickly switch to your energy-saving away preferences
- VACATION SCHEDULING – Allows you to save while you’re away and come home to comfort
- STANDBY SCREEN – Displays indoor temperature and current weather
OPERATIONAL FEATURES
- AUTOMATIC CHANGEOVER – Transitions between heating and cooling automatically to keep the house comfortable
- INTEGRATED WATER CONTROL – Enables easy water heater management
- SMOOTH ARRIVAL – Prompts the system to start ahead of schedule to ensure the home is at the desired temperature at the scheduled time
- HUMIDITY CONTROL – Supports humidifier accessories or over-cool-based dehumidification
- DETAILED OPERATING STATUS – View pertinent equipment status information and run times
- CONTINUOUS FAN – Offers 5 speeds (Low, Medium Low, Medium, Medium High, High)
- SHORT-CYCLE PROTECTION – Avoids damage to equipment from short-run cycles
MONITORING & REMOTE CONTROL FEATURES
- ACTIVE MONITORING – Alerts to problems that need immediate attention
- REMOTE CONTROL – Allows adjusting of comfort and settings from anywhere using a mobile device
- SERVICE ALERTS – Sends routine maintenance reminders
- AIR FILTER MONITORING – Detects when it’s time to replace the air filter
- ALARM HISTORY – Displays time-stamped alarm codes with clear descriptions
GENERAL TERMS OF LIMITED WARRANTY
- Friedrich® will furnish a replacement for any part of this product that fails in normal use and service within the applicable period stated, in accordance with the terms of the limited warranty.
- For complete details of the Limited and Conditional Warranties, including applicable terms and conditions, contact your local contractor or the Manufacturer for a copy of the product warranty certificate.
- Conditional Parts (Registration Required) …………………………….. Ten (10) Years
- Before proceeding with installation, refer to installation instructions packaged with each model, as well as complying with all Federal, State, Provincial, and Local codes, regulations, and practices.
- © 2023 Rheem Manufacturing Company. Friedrich trademarks are owned by Rheem Manufacturing Company.
- In keeping with its policy of continuous progress and product improvement, Friedrich reserves the right to make changes without notice.
- Friedrich 5600 Old Greenwood Road
- Fort Smith, Arkansas 72908 www.friedrich.com
Documents / Resources
|
FRIEDRICH F-Series Plus iM Air
Conditioners
[pdf] User Manual
FRA15AZ24AJ3CA, FRA15AZ36AJ3CA, FRA15AZ48AJ3CA, FRA15AZ60AJ3CA, F-Series Plus
iM Air Conditioners, F-Series Plus, iM Air Conditioners, Air Conditioners,
Conditioners
---|---