FRIEDRICH UET08B11A Built In Through the Wall Air Conditioner Instruction Manual
- June 1, 2024
- FRIEDRICH
Table of Contents
- FRIEDRICH UET08B11A Built In Through the Wall Air Conditioner
- Product Usage Instructions
- FAQs
- IMPORTANT SAFETY AND GENERAL INFORMATION
- SPECIFICATIONS
- INSTALLATION OF THE UNIT
- ELECTRICAL
- Electrical Safety Information
- STARTUP AND OPERATION
- TROUBLESHOOTING
- INFORMATION FOR THE OWNER
- Warranty
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
- 2 Phillips Screw Driver
FRIEDRICH UET08B11A Built In Through the Wall Air Conditioner
Specifications
Standard Chassis Models Using R-32 Refrigerant
- 115 VOLT: UCT08B10A, UCT10B10A, UCT12B10A
- 230 VOLT: UCT10B30A, UCT12B30A, UCT14B30A
- 230 VOLT: UET08B11A, UET10B33A, UET12B33A, UET14B33A
Product Usage Instructions
A. Important Safety and General Information
A.1 Introduction
This booklet contains the installation and operating instructions for your Air Conditioning unit. Improper installation can result in unsatisfactory operation or dangerous conditions. Read this booklet and any instructions packaged with separate equipment required to make up the system prior to installation.
A.2 Safety Warnings
WARNING: The manufacturer’s warranty does not cover any damage or defect to the air conditioner caused by the attachment or use of unauthorized components, accessories, or devices. The use of unauthorized components may adversely affect the operation of the air conditioner and may endanger life and property.
B. Specifications
B.1 Dimensions
Dimensions information should be provided here.
C. Installation of the Unit
C.1 Pre-Installation Checkpoints
Check all necessary components are included and inspect for any damage.
C.2 Tools Required
List of tools required for installation should be provided here.
C.3 Choosing a Location
Select a suitable location for installation ensuring proper ventilation and access to power source.
C.4 Sleeve Installation
Follow instructions to install the sleeve properly to support the unit.
C.5 Chassis Installation
Step-by-step guide on how to install the chassis of the air conditioner.
E. Electrical
E.1 Electrical Safety Information
Important electrical safety information should be followed during installation and operation.
FAQs
- Q: Where can I find the model information?
- A: The model information can be found on the nameplate of the air conditioner.
- Q: How do I register my air conditioner?
- A: You can either complete and mail the owner registration card provided with the product or register online at www.friedrich.com.
- Q: What refrigerant is used in this air conditioner?
- A: The air conditioner uses R-32 refrigerant.
CAUTION: Do Not Operate Equipment During Active Stages Of Construction
To ensure proper operation, Friedrich requires that all equipment is not operated during active construction phases. This includes active stages of completing framing, drywalling, spackling, sanding, painting, flooring, and molding in the equipment’s designated conditioning space. The use of this equipment during construction could result in premature failure of the components and/or system and is in violation of our standard warranty guidelines. The operation of newly installed equipment during construction will accelerate the commencement and/or termination of the warranty period.
Register your Air Conditioner
Model information can be found on the nameplate. Please complete and mail the owner registration card furnished with this product, or register online at www.friedrich.com
IMPORTANT SAFETY AND GENERAL INFORMATION
Introduction
This booklet contains the installation and operating instructions for your Air Conditioning unit. There are some precautions that should be taken to ensure proper operation. Improper installation can result in unsatisfactory operation or dangerous conditions. Read this booklet and any instructions packaged with separate equipment required to make up the system prior to installation. Give this booklet to the owner and explain its provisions. The owner should retain this booklet for future reference.
Safety Warnings
WARNING: The manufacturer’s warranty does not cover any damage or defect to
the air conditioner caused by the attachment or use of any components,
accessories or devices (other than those authorized by the manufacturer) into,
onto or in conjunction with the air conditioner. You should be aware that the
use of unauthorized components, accessories or devices may adversely affect
the operation of the air conditioner and may also endanger life and property.
The manufacturer disclaims any responsibility for such loss or injury
resulting from the use of such unauthorized components, accessories or
devices.
WARNING: Electrical Shock Hazard Disconnect all power to the unit before
starting maintenance. All electrical connections and wiring MUST be installed
by a qualified electrician and conform to the National Code and all local
codes which have jurisdiction. Failure to do so can result in property damage,
severe electrical shock or death.
WARNING: Read Installation Manual Please read this manual thoroughly prior to
equipment installation or operation. It is the installer’s responsibility to
properly apply and install the equipment. Installation must be in conformance
with the NFPA 70-2023 national electric code or current edition, International
Mechanic code 2021 or current edition, and any other local or national codes.
WARNING: Safety First Do not remove, disable, or bypass this unit’s safety
devices. Doing so may cause fire, injuries, or death.
Read All Instructions and Cautionary Markings Before Operation
and Installation to prevent death or injury to the user, other people,
or property damage, the following instructions must be followed.
Incorrect operation due to ignoring of instructions may cause death,
harm or damage.
WARNING: This symbol indicates the possibility of a
hazard to personnel.
CAUTION: This symbol indicates the possibility of
property damage or serious consequences.
WARNING:
- Installation must be performed according to the installation instructions. Improper installation can cause water leakage, electrical shock, or fire.
- Use only the included accessories and parts, and specified tools for the installation. Using nonstandard parts can cause water leakage, electrical shock, fire, and injury or property damage.
- Make sure that the outlet you are using is grounded and has the appropriate voltage. The power cord is equipped with a three-prong grounding plug to protect against shock. Voltage information can be found on the nameplate of the appliance.
- Your appliance must be used in a properly grounded wall receptacle. If the wall receptacle you intend to use is not adequately grounded or protected by a time delay fuse or circuit breaker (the fuse or circuit breaker needed is determined by the maximum current of the appliance. The maximum current is indicated on the model nameplate located on the appliance, have a qualified electrician install the proper receptacle.
- Install the appliance on a flat, sturdy surface. Failure to do so could result in damage or excessive noise and vibration.
- The appliance must be kept free from obstruction to ensure proper function and to mitigate safety hazards.
- The unit should not be in contact with any equipment that will transmit vibration to the unit. Any excessive vibration or pulsation to the unit could result in damage to the refrigerant tubing.
- Do not modify the length of the power cord or use an extension cord to power the appliance.
- Do not share a single outlet with other electrical appliances. Improper power supply can cause fire or electrical shock.
- Do not install your air conditioner in a wet room such as a bathroom or laundry room. Too much exposure to water can cause electrical components to short circuit.
- Do not install the appliance in a location that may be exposed to combustible gas, as this could cause fire.
- Do not operate the appliance if it has been dropped or damaged.
- Do not touch the appliance with wet or damp hands or when barefoot.
- If the air conditioner is knocked over during use, turn off the appliance and unplug it from the main power supply immediately. Visually inspect the appliance to ensure there is no damage. If you suspect the appliance has been damaged, contact a technician or customer service for assistance.
- In a thunderstorm, the power must be cut off to avoid damage to the machine due to lightning. Your air conditioner should be used in such a way that it is protected from moisture. e.g. condensation, splashed water, etc. Do not place or store your air conditioner where it can fall or be pulled into water or any other liquid. Unplug immediately if it occurs.
- All wiring must be performed strictly in accordance with the wiring diagram located inside of the appliance.
- The appliance’s circuit board(PCB) is designed with a fuse to provide over current protection. The specifications of the fuse are printed on the circuit board, such as: T 3.15A/250V, etc.
- After proper installation, condensate will not overflow during normal use. If the fan hits the built-up water and the sound annoys you, please remove the cap located at the back of the air conditioner to drain the water away.
CAUTION:
- This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance. Children must be supervised around the appliance at all times.
- If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard.
- Prior to cleaning or other maintenance, the appliance must be disconnected from the supply mains.
- Never use this appliance if it is not working properly, or if it has been dropped or damaged.
- Do not run cord under carpeting. Do not cover cord with throw rugs, runners, or similar coverings. Do not route cord under furniture or appliances. Arrange cord away from traffic area and where it will not be tripped over.
- Do not operate with a damaged cord, plug, power fuse or circuit breaker. Discard the appliance or return to an authorized service facility for examination and/or repair.
- To reduce the risk of fire or electric shock, do not use this fan with any solid-state speed control device.
- The appliance shall be installed in accordance with national wiring regulations.
- Contact the authorized service technician for repair or maintenance of this appliance.
- Contact the authorized installer for installation of this appliance.
- Do not cover or obstruct the inlet or outlet grilles.
- Do not use this product for functions other than those described in this instruction manual.
- Before cleaning, turn off the power and unplug the appliance.
- Disconnect the power if strange sounds, smell, or smoke comes from it.
- Do not press the buttons on the control panel with anything other than your fingers.
- Do not operate or stop the appliance by inserting or pulling out the power cord plug.
- Do not use hazardous chemicals to clean or come into contact with the appliance.
- Do not use the appliance in the presence of flammable substances or vapor such as alcohol, insecticides, petrol,etc.
- Always contact a qualified person to carry out repairs. If the power supply cord is damaged, it must be replaced with a new power supply cord obtained from the product manufacturer and not repaired.
- Hold the plug by the head of the power plug when taking it out.
- Turn off the product when not in use.
Warning For Using R32 Refrigerant
For R32 refrigerant models:
- Appliance shall be installed, operated and stored in a room with a floor area larger than 43 sq ft.
- Appliance shall not be installed in an unventilated space, if that space is smaller than 43 sq ft.
- Compliance with national gas regulations shall be observed.
- Keep ventilation openings clear of obstruction.
- The appliance shall be stored so as to prevent mechanical damage from occurring.
- A warning that the appliance shall be stored in a well-ventilated area where the room size corresponds to the room area as specified for operation.
- Any person who is involved with working on or opening a refrigerant system must be certified for refrigerant handling as required by local, state, and federal regulations.
- Servicing shall only be performed as recommended by the equipment manufacturer. Maintenance and repair requiring the assistance of other skilled personnel shall be carried out under the supervision of the person competent in the use of flammable refrigerants.
- Please follow the instruction carefully to handle, install, clear, and service the air conditioner to avoid any damage or hazard. Flammable Refrigerant R32 is used within air conditioner. When maintaining or disposing the air conditioner, the refrigerant (R32) shall be recovered properly, and shall not be discharged to air directly.
- No any open fire or device like a switch which may generate spark/arcing shall be around the air conditioner to avoid causing ignition of the flammable refrigerant used.
- Please follow the instruction carefully to store or maintain the air conditioner to prevent mechanical damage from occurring.
- Flammable refrigerant R32 is used in air conditioner. Please follow the instruction carefully to avoid any hazard.
- For specific information on the type of gas and the amount of refrigerant used, refer to the model nameplate on the unit.
CAUTION: Risk of fire/flammable materials (Required for R32 units only)
WARNING: low burning velocity material (For R32 models apply to IEC60335-2-40:2018)
Note about Fluorinated Gases
- Fluorinated greenhouse gases are contained in hermetically sealed equipment. For specific information on the type, the amount and the Co2 equivalent in tonnes of the fluorinated greenhouse gas(on some models), please refer to the relevant label on the unit itself.
- Installation, service, maintenance and repair of this unit must be performed by a certified technician.
- Product uninstallation and recycling must be performed by a certified technician.
For Household Use Only Read And Save These Instructions
- Transport of equipment containing flammable refrigerants: See transport regulations.
- Marking of equipment using signs: See local regulations.
- Disposal of equipment using flammable refrigerants: See national regulations.
- Storage of equipment/appliances: The storage of equipment should be in accordance with the manufacturer’s instructions.
- Storage of packed (unsold) equipment: Storage package protection should be constructed such that mechanical damage to the equipment inside the package will not cause a leak of the refrigerant charge. The maximum number of pieces of equipment permitted to be stored together will be determined by local regulations.
Information on servicing:
-
Checks to the area: Prior to beginning work on systems containing flammable refrigerants, safety checks are necessary to ensure that the risk of ignition is minimized. For repair to the refrigerating system, the following precautions shall be complied with prior to conducting work on the system.
-
Work procedure: Work shall be undertaken under a controlled procedure so as to minimize the risk of a flammable gas or vapor being present while the work is being performed.
-
General work area: All maintenance staff and others working in the local area shall be instructed on the nature of work being carried out. Work in confined spaces shall be avoided. The area around the workspace shall be sectioned off. Ensure that the conditions within the area have been made safe by control of flammable material.
-
Checking for presence of refrigerant: The area shall be checked with an appropriate refrigerant detector prior to and during work, to ensure the technician is aware of potentially flammable atmospheres. Ensure that the leak detection equipment being used is suitable for use with flammable refrigerants, i.e. non-sparking, adequately sealed or intrinsically safe.
-
Presence of fire extinguisher: If any hot work is to be conducted on the refrigeration equipment or any associated parts, appropriate fire extinguishing equipment shall be available to hand. Have a dry powder or CO2 fire extinguisher adjacent to the charging area.
-
No ignition sources: No person carrying out work in relation to a refrigeration system which involves exposing any pipe work that contains or has contained flammable refrigerant shall use any sources of ignition in such a manner that it may lead to the risk of fire or explosion. All possible ignition sources, including cigarette smoking, should be kept sufficiently far away from the site of installation, repairing, removing and disposal, during which flammable refrigerant can possibly be released to the surrounding space. Prior to work taking place, the area around the equipment is to be surveyed to make sure that there are no flammable hazards or ignition risks. No Smoking signs shall be displayed.
-
Ventilated area: Ensure that the area is in the open or that it is adequately ventilated before breaking into the system or conducting any hot work. A degree of ventilation shall continue during the period that the work is carried out. The ventilation should safely disperse any released refrigerant and preferably expel it externally into the atmosphere.
-
Checks to the refrigeration equipment: Where electrical components are being changed, they shall be fit for the purpose and to the correct specification. At all times the manufacturer’s maintenance and service guidelines shall be followed. If in doubt consult the manufacturer’s technical department for assistance. The following checks shall be applied to installations using flammable refrigerants:
- a. The charge size is in accordance with the room size within which the refrigerant containing parts are installed;
- b. The ventilation machinery and outlets are operating adequately and are not obstructed;
- c. If an indirect refrigerating circuit is being used, the secondary circuit shall be checked for the presence of refrigerant; Marking to the equipment continues to be visible and legible. Markings and signs that are illegible shall be corrected;
- d. Refrigeration pipe or components are installed in a position where they are unlikely to be exposed to any substance which may corrode refrigerant-containing components, unless the components are constructed of materials which are inherently resistant to being corroded or are suitably protected against being so corroded.
-
Checks to electrical devices: Repair and maintenance to electrical components shall include initial safety checks and component inspection procedures. If a fault exists that could compromise safety, then no electrical supply shall be connected to the circuit until it is satisfactorily dealt with. If the fault cannot be corrected immediately but it is necessary to continue operation, an adequate temporary solution shall be used. This shall be reported to the owner of the equipment so all parties are advised.
Initial safety checks shall include:- a. That capacitors are discharged: this shall be done in a safe manner to avoid possibility of sparking;
- b. That there no live electrical components and wiring are exposed while charging, recovering or purging the system;
- c. That there is continuity of earth bonding.
-
Repair to intrinsically safe components: Do not apply any permanent inductive or capacitance loads to the circuit without ensuring that this will not exceed the permissible voltage and current permitted for the equipment in use. Intrinsically safe components are the only types that can be worked on while live in the presence of a flammable atmosphere. The test apparatus shall be at the correct rating. Replace components only with parts specified by the manufacturer. Other parts may result in the ignition of refrigerant in the atmosphere from a leak.
-
Cabling: Check that cabling will not be subject to wear, corrosion, excessive pressure, vibration, sharp edges or any other adverse environmental effects. The check shall also take into account the effects of aging or continual vibration from sources such as compressors or fans.
-
Detection of flammable refrigerants Under no circumstances shall potential sources of ignition be used in the searching for or detection of refrigerant leaks. A halide torch (or any other detector using a naked flame) shall not be used.
-
Leak detection methods: The following leak detection methods are deemed acceptable for systems containing flammable refrigerants. Electronic leak detectors shall be used to detect flammable refrigerants, but the sensitivity may not be adequate, or may need re-calibration. (Detection equipment shall be calibrated in a refrigerant-free area.) Ensure that the detector is not a potential source of ignition and is suitable for the refrigerant used. Leak detection equipment shall be set at a percentage of the LFL of the refrigerant and shall be calibrated to the refrigerant employed and the appropriate percentage of gas (25 % maximum) is confirmed. Leak detection fluids are suitable for use with most refrigerants but the use of detergents containing chlorine shall be avoided as the chlorine may react with the refrigerant and corrode the copper pipe-work. If a leak is suspected, all naked flames shall be removed/extinguished. If a leakage of refrigerant is found which requires brazing, all of the refrigerant shall be recovered from the system, or isolated (by means of shut off valves) in a part of the system remote from the leak. Oxygen free nitrogen (OFN) shall then be purged through the system both before and during the brazing process.
-
Removal and evacuation When breaking into the refrigerant circuit to make repairs or for any other purpose conventional procedures shall be used. However, it is important that best practice is followed since flammability is a consideration. The following procedure shall be adhered to: Remove refrigerant; Purge the circuit with inert gas; Evacuate; Purge again with inert gas; Open the circuit by cutting or brazing. The refrigerant charge shall be recovered into the correct recovery cylinders. The system shall be flushed with OFN to render the unit safe. This process may need to be repeated several times. Compressed air or oxygen shall not be used for this task. Flushing shall be achieved by breaking the vacuum in the system with OFN and continuing to fill until the working pressure is achieved, then venting to atmosphere, and finally pulling down to a vacuum. This process shall be repeated until no refrigerant is within the system. When the final OFN charge is used, the system shall be vented down to atmospheric pressure to enable work to take place. This operation is absolutely vital if brazingoperations on the pipe-work are to take place. Ensure that the outlet for the vacuum pump is not close to any ignition sources and there is ventilation available.
12. Charging procedures: In addition to conventional charging procedures, the following requirements shall be followed. Ensure that contamination of different refrigerants does not occur when using charging equipment. Hoses or lines shall be as short as possible to minimize the amount of refrigerant contained in them. Cylinders shall be kept upright. Ensure that the refrigeration system is earthed prior to charging the system with refrigerant. Label the system when charging is complete (if not already). Extreme care shall be taken not to overfill the refrigeration system. Prior to recharging the system it shall be pressure tested with OFN. The system shall be leak tested on completion of charging but prior to commissioning. A follow up leak test shall be carried out prior to leaving the site.
13. Decommissioning: Before carrying out this procedure, it is essential that the technician is completely familiar with the equipment and all its detail. It is recommended good practice that all refrigerants are recovered safely. Prior to the task being carried out, an oil and refrigerant sample shall be taken in case analysis is required prior to re-use of reclaimed refrigerant. It is essential that electrical power is available before the task is commenced.-
* a. Become familiar with the equipment and its operation.
- b. Isolate system electrically.
- c. Before attempting the procedure ensure that: Mechanical handling equipment is available, if required, for handling refrigerant cylinders; All personal protective equipment is available and being used correctly; The recovery process is supervised at all times by a competent person; Recovery equipment and cylinders conform to the appropriate standards.
- d. Pump down the refrigerant system, if possible.
- e. If a vacuum is not possible, make a manifold so that refrigerant can be removed from various parts of the system.
- f. Make sure that cylinder is situated on the scales before recovery takes place.
- g. Start the recovery machine and operate in accordance with the manufacturer’s instructions.
- h. Do not overfill cylinders. (No more than 80 % volume liquid charge).
- i. Do not exceed the maximum working pressure of the cylinder, even temporarily.
- j. When the cylinders have been filled correctly and the process completed, make sure that the cylinders and the equipment are removed from site promptly and all isolation valves on the equipment are closed off.
- k. Recovered refrigerant shall not be charged into another refrigeration system unless it has been cleaned and checked.
-
-
Labeling: Equipment shall be labeled stating that it has been de-commissioned and emptied of refrigerant. The label shall be dated and signed. Ensure that there are labels on the equipment stating the equipment contains flammable refrigerant.
-
Recovery: When removing refrigerant from a system, either for servicing or decommissioning, it is recommended good practice that all refrigerants are removed safely. When transferring refrigerant into cylinders, ensure that only appropriate refrigerant recovery cylinders are employed. Ensure that the correct number of cylinders for holding the total system charge is available. All cylinders to be used are designated for the recovered refrigerant and labeled for that refrigerant (i.e. special cylinders for the recovery of refrigerant). Cylinders shall be complete with pressure relief valve and associated shut-off valves in good working order. Empty recovery cylinders are evacuated and, if possible, cooled before recovery occurs. The recovery equipment shall be in good working order with a set of instructions concerning the equipment that is at hand and shall be suitable for the recovery of flammable refrigerants. In addition, a set of calibrated weighing scales shall be available and in good working order. Hoses shall be complete with leak-free disconnect couplings and in good condition. Before using the recovery machine, check that it is in satisfactory working order, has been properly maintained and that any associated electrical components are sealed to prevent ignition in the event of a refrigerant release. Consult manufacturer if in doubt. The recovered refrigerant shall be returned to the refrigerant supplier in the correct recovery cylinder, and the relevant Waste Transfer Note arranged. Do not mix refrigerants in recovery units and especially not in cylinders. If compressors or compressor oils are to be removed, ensure that they have been evacuated to an acceptable level to make certain that flammable refrigerant does not remain within the lubricant. The evacuation process shall be carried out prior to returning the compressor to the suppliers. Only electric heating to the compressor body shall be employed to accelerate this process. When oil is drained from a system, it shall be carried out safely.
NOTE: Check the appliance regularly and refer to TROUBLESHOOTING or contact our customer support if it shows any of the following signs:- Power cord or plug is damaged.
- Loud noise, unusual smell or excessive heat.
Importance of a Quality Installation
Optimal system performance and longevity depend upon quality and proper
installation. Failure to properly install this unit could result in
undesirable operation and subsequent faults and potential failures. Carefully
follow all guidelines listed in the manual and industry best practices.
Conform to all local code requirements. Contact your local technical
representative with any questions or concerns. Upon receiving the unit,
inspect it for any damage from shipment. Claims for damage, either shipping or
concealed, should be filed immediately with the shipping company. IMPORTANT:
Check the unit model number, Cooling size, electrical characteristics, and
accessories to determine if they are correct.
WARNING: If the unit appears damaged or if a refigerant leak is suspected, do
not install.Contact a licenced repair person to perform a leak check on the
unit,
WARNING:Under no circumstances shall potential sources of ignition be used in
the searching for or detection of refrigerant leaks. A halide torch (or any
other detector using a naked flame) shall not be used. The following leak
detection methods are deemed acceptable for all refrigerant systems.
Electronic leak detectors may be used to detect refrigerant leaks but, in the
case of FLAMMABLE REFRIGERANTS, the sensitivity may not be adequate, or may
need re-calibration. (Detection equipment shall be calibrated in a refrigerant
free area.) Ensure that the detector is not a potential source of ignition and
is suitable for the refrigerant used. Leak detection equipment shall be set at
a percentage of the LFL.
WARNING:Service of this product (aside from filter maintenance) shall only be
performed by trained service personnel. This includes: Opening of any
ventilated Any tubing or refrigerant circuit work Opening of any sealed
components Enclosures beyond the hinged door for filter cleaning Scan this QR
code to be linked to the Friedrich professional support page where you can
locate the Service Manual.
Product Inspection / Packing List
Upon receiving the unit, inspect it for any damage from shipment. Claims for damage, either shipping or concealed, should be filed immediately with the shipping company. IMPORTANT: Check the unit model number, Cooling size, electrical characteristics, and accessories to determine if they are correct.
SPECIFICATIONS
INSTALLATION OF THE UNIT
Pre-Installation Checkpoints
Before attempting any installation, carefully consider the following points:
- Clearances and provision for servicing. Install this unit in accordance with local and national standards. Any and all work must be done by authorized personnel.
- IMPORTANT: Before you begin the actual installation of your air conditioner, check your local electrical codes and the information below. Your air conditioner must be connected to a power source with the same alternating current (A.C.) voltage and amperage as marked on the name plate located on the chassis. Only A.C. can be used. Direct Current (D.C.) cannot be used.
- CIRCUIT PROTECTION – Use on single outlet circuit only. An overloaded circuit will invariably cause malfunction or failure of an air conditioner; therefore, it is necessary that the electrical protection is adequate. Due to momentary high current demand when the air conditioner starts, use a “TIME DELAY” fuse or a HACR type circuit breaker. Consult your dealer or power company if in doubt.
- Refer to the electrical name plate located on the air conditioner chassis (see Table E.1 to determine the correct fuse or circuit breaker amperage for your model.
- The power cord has a plug with a grounding prong and a matching receptacle is required.
Tools Required
- Power Drill
- 1/8 Drill Bit
- Gloves
- Carpenters Level
-
2 Phillips Screw Driver
- Putty Knife or (wood stir stick)
Choosing a Location
Installation Clearances
Improper installation of the Air Conditioner can cause poor performance and premature wear of the unit. Ensure that the unit is installed with proper clearances as described below. Ensure no obstructions or enclosures are within clearances limits to allow for proper airflow. Ensure no open flames, or surfaces that will exceed 1000 degrees Fahrenheit are within clearances limits.
Clearances
Top and Bottom of Unit – One (1) foot
- Sides of Unit – One (1) foot
- Front of Unit – Three (3) feet
- Rear of Unit – Three (3) feet
Installation Instructions for USC Sleeve
(USC Sleeve Sold Separately) Wall Preparation
- STEP 1. The wall opening required for a USC SLEEVE is 15 25/32 high by 26 1/8 wide.
- STEP 2. LINTELS must be used in opening of brick veneer and masonry walls to support the material above the USC SLEEVE. The following considerations should also be given:
- A. Masonry walls to support the material above the USC SLEEVE.
- B. Adjustable SUBBASE (SB) or other unit support must be provided for panel wall type construction and for walls less than 8 thick.
Installation Requirements
- STEP 1. The USC sleeve should be positioned so that the drain extension extends a minimum of 9/16 beyond the outside wall (see Figure C.4.1).
- STEP 2. The USC sleeve must extend a minimum of 7/8 beyond the inside wall.
- STEP 3. The USC sleeve must be installed level side to side.
- STEP 4. The USC sleeve must also be installed with a downward tilt toward the outside of the building. If a level is placed so that it rests on the front and back unit rest as shown in Figure C.4.2, a properly installed unit provides a 3/8” slope to the outside of the building.
NOTICE
Sleeve projections and leveling precautions must be observed to prevent the entry of water into the room.
Sleeve Requirements
-
STEP 1. After unpacking the USC sleeve from the carton, remove the indoor weather panel. Place the USC sleeve in the wall opening following the instructions given in the Installation Requirements. Attach the sleeve to the inside wall by driving two #12A x 2” screws in each side of the sleeve (see Figure C.4.3). Shim at the top of the sleeve, midway between the sides. Drive one #12A x 2” screw in the top of the sleeve. If the wall opening is not framed with wood, use expansion anchor bolts or molly (toggle) bolts (not provided).
-
STEP 2. Once the sleeve has been installed, check the level again to be sure the 3/8” downward slope is maintained.
NOTE: If necessary, apply shims below the chassis and inside the sleeve front unit rest, to ensure a 3/8” downward slope front to back. -
STEP 3. Caulk the perimeter of the entire opening on the inside and the outside between the sleeve and the wall.
-
STEP 4. The indoor weather panel removed in Step 1 above must be remounted back in place if masonry work is to be done and/ or if the “Uni-fit”chassis is to be installed at a later date.
Chassis Installation
Chassis Preparation
- STEP 1. Check the sleeve to be certain it has been correctly installed in the wall. Remove the front panel on the USC SLEEVE. Remove the rear WEATHER PANEL. Reverse grille. Place lower edge into sleeve tab (Friedrich logo facing out). Align slots with the screw holes. Secure grille with screws.
- A. Check the anchor screw. There should be four (4) in the USC SLEEVE (two in each side).
- B. Determine if the sleeve has a downward slope of 3/8 to the outside. See figure C.4.2 for further details.
- C. Check to be sure the sleeve has been sealed around all edges with industrial type caulking on both the outside and inside to prevent rain entry.
- STEP 2. Check the electrical receptacle to see that it conforms to the requirements for the chassis model to be installed. See Figure E.1 for the receptacle requirements.
- STEP 3. Remove the chassis from the shipping carton. Lift the chassis by the basepan and slide it into the front of the sleeve. (Obtain assistance as needed.) Push the chassis all the way into the sleeve, using the plastic front handles, so that the front panel meets the front edge of the shell.
- NOTE: Chassis comes with a pre-installed seal gasket.
IMPORTANT: To ensure proper performance and energy efficiency it is essential that the chassis is properly installed in the wall sleeve.
This includes:
- Utilize the proper rear grille.
- Sealing all gaps between the unit and the rear grille.
- Sealing all gaps around the units to prevent air leakage from outside of the building to the inside.
- Installing the chassis so the rear grill is flush or extends beyond the sleeve.
Chassis Installation
Recommended Installation Method: Uni-Fit Dual Intake Grille with Friedrich USC Sleeve
-
Identify the wall-sleeve you are preparing. It is recommended to use the USC sleeve in any instance possible. The below table shows the standard dimension for the wall-sleeve required
NOTE:- a) All wall sleeves used to mount the new air conditioner must be in sound structural condition and the rear grille should be securely attached to the unit or unit as the instructions recommend.
- b) If wall sleeve used is not the recommended Friedrich USC sleeve, ensure the dimensions are suitable for the installation.
- c) Any wall sleeve used needs to be securely fastened to the wall; ensure all sleeve installation instructions are followed to completion. Any existing sleeve should be inspected to ensure it is securely fastened.
-
If preparing a new sleeve, please follow the sleeve instructions to ensure proper installation; Friedrich recommends using the Friedrich USC sleeve for best performance. If using existing sleeve, remove the old air conditioner from the wall sleeve and prepare the wall sleeve as follows:
- a. Clean interior (remove legacy gaskets and seals as necessary)
- b. Examine the wall sleeve and ensure the sleeve is securely fastened before installing. Add more fasteners as needed.
- c. Touch up any wall sleeve area that is missing paint to help prevent corrosion.
-
Remove the back grille
- a. The old intake grille must be removed and replaced by the UXAA (or optional alternate) detailed in this instruction.
- b. Warning: When removing the grille, protect from falling by securing with a leash. Loop strapping material through the grille and secure tightly with a knot. Holding the grille by the leash with one hand, the retaining screws can then be removed and the grille can be brought in through the front of the sleeve.
-
Examine the grounding wire hole.
- a. If it does not exist, drill a 3/16” pilot hole through the left-hand side of the sleeve, in a clear area about 3 inches into the front edge of the sleeve (as shown in image below).
- b. Fasten the grounding wire with screw to the drilled hole and pull the loose end of the ground wire out of the front of the sleeve and bend it away from the opening. This will be attached to the air conditioner once installed.
-
Add centering blocks to shell
- a. To help center the unit once it is placed inside of the sleeve. Cut two of the adhesive backed 3 3/8” x 1 1/2” x 4 1/2”seal cottons down to fill the difference between the width of the air conditioner and the width of the sleeve. Remove liner and place on either side of the shell.
-
Gasket the Dual Intake Grille
- a. Gasket the perimeter of the dual intake grille using the remaining ¼” thick seal sponges
-
Install the dual intake grille to the back of the TTW unit.
- a. Using the pre-drilled hole locations, use the 4 provided fasteners to secure the grille to the back of the TTW unit
- b. If markings are present on the grille, use them as guides to assist in the proper installation of the grille.
- c. Put the [OUTSIDE] lettering toward the back side of the sleeve; The [UP] markings should be pointed to the top of the sleeve.
- d. Ensure that from the back side of the TTW unit, the seven inlet opening should be on the left side while the eight inlet opening should be on the right side.
-
Install the grounding wire
- a. Install screw end of the ground wire into the inside of sleeve according to the preparation instruction.
- b. Remove the second screw from the left side of unit and remove the plastic washer.
- c. Screw the other end of the ground wire into the unit; make sure the toothed washer is against the cabinet
-
Install the TTW unit into the wall sleeve
- a. Gently slide the TTW unit into the wall-sleeve.
-
b. If the shell does not have the 3/8” tilt required, apply shims below the chassis front and inside the sleeve to ensure a 3/8” downward slope front to back. Optional Installation Method A: Install Friedrich Architectural louver (UXAA) on Friedrich USC Sleeve. Both sold separately. 1-NOTE: Please follow Steps 1 through 5 of the Recommended installation method before proceeding.
-
Install Friedrich Architectural louver UXAA
- a. Install UXAA architectural louver per the instructions
-
Prepare the air conditioner for installation.
- a. Remove the liner from the two 1” x ¼” x ¾” adhesive backed seal sponges and place on either side of the condenser as shown in the below image
- Follow steps 8-9 of the recommended installation option to finish the unit installation.
Optional Installation Method B: Uni-Fit Dual Intake Grille with
Generic Sleeve (Not Friedrich USC Sleeve) 1-5. NOTE: Please follow Steps 1
through 5 of the recommended installation methods before proceeding.
- Install Uni-Fit Dual Intake Grille
- a. Install the dual intake grille onto the back of the sleeve.
- Warning: To prevent the sleeve from falling, secure grille with a zip tie and remove after installation is complete.
- b. Put the [OUTSIDE] lettering toward the back side of the sleeve; The [UP] markings should be pointed to the top of the sleeve.
- c. Ensure that from the back side of the TTW unit, the seven inlet opening should be on the left side while the eight inlet opening should be on the right side.
- Seal the inside of the Wall-Sleeve
- a. Stick and seal two 1” x 1 1/2” x 25” pieces of seal sponge on top and bottom of the back, inside edge of the shell
- b. Stick and seal two 1” x 1 1/2” x 13 3/4” pieces of seal sponge on left and right side of the back inside edge.
- c. IMPORTANT: If the seal sponge blocks the grille inlet or outlet, modify them to a suitable dimension or thickness that will not cause any blockage.
- 8-9. Follow steps 8-9 of the recommended installation option to finish the unit installation.
ELECTRICAL
Electrical Safety Information
Make sure the wiring is adequate for your unit.
If you have fuses, they should be of the time delay type. Before you install or relocate this unit, be sure that the amperage rating of the circuit breaker or time delay fuse does not exceed the amp rating listed in Table 1.
DO NOT use an extension cord.
The cord provided will carry the proper amount of electrical power to the unit; an extension cord may not.
Make sure that the receptacle is compatible with the air conditioner cord plug provided.
Proper grounding must be maintained at all times. Two prong receptacles must be replaced with a grounded receptacle by a certified electrician. The grounded receptacle should meet all national and local codes and ordinances. You must use the three prong plug furnished with the air conditioner. Under no circumstances should you remove the ground prong from the plug.
Testing the Power Cord
All Friedrich room air conditioners are shipped from the factory with a
Leakage Current Detection Interrupter (LCDI) equipped power cord. The LCDI
device on the end of the cord meets the UL and NEC requirements for cord
connected air conditioners.
To test your power supply cord:
- Plug power supply cord into a grounded 3 prong outlet.
- Press RESET (see Figure E.2).
- Press TEST, listen for click; the RESET button trips and pops out.
- Press and release RESET (Listen for click; RESET button latches and remains in). The power cord is ready for use.
Once plugged in, the unit will operate normally without the need to reset the LCDI device. If the LCDI device fails to trip when tested or if the power supply cord is damaged, it must be replaced with a new power supply cord from the manufacturer..
STARTUP AND OPERATION
Control Panel Operation
USING YOUR AIR CONDITIONER Electronic Control Panel & Remote Control
NOTE: This display always shows the room temperature in Fan Mode except when setting the Timer.
Normal Operating Sounds
- You may hear a pinging noise caused by water hitting the condenser on rainy days, or when the humidity is high. This design feature helps remove moisture and improve efficiency.
- You may hear the thermostat click when the compressor cycles on and off.
- Water will collect in the base pan during rain or days of high humidity. The water may overflow and drip from the outside part of the unit.
- The fan may run even when the compressor is not on.
-
Digital Display: Without timer setting, the set temperature will be displayed. Time will be displayed under the timer setting.
-
+ and – Button: Use these buttons on the control panel and remote to increase or decrease the Set Temperature or Timer.
Temperature range: 61″F~88″F or 16’C~31 ‘C. -
Button: Turn the air conditioner on and off.
-
Mode Button: Press the mode button to cycle through the various modes: Cool, Dry, Fan and Auto, or Heat.
- Cool Mode: The cooling function allows the air conditioner to cool the room and at the same time reduces air humidity. Press the MODE button to activate the cooling function. To optimize the function of the air conditioner, adjust the temperature and the speed by pressing the button indicated.
- Dry Mode: This function reduces the humidity of the air to make the room more comfortable. Press MODE button to set the DRY mode. An automatic function of alternating cooling cycles and air fan is activated.
- Fan Mode: The conditioner works in only ventilation. Press MODE button to set the FAN mode. With pressing the FAN SPEED button the speed changes in the following sequence: Hi, Med and Low in FAN mode.
- Auto Mode: In AUTO mode the unit automatically chooses the fan speed and the mode of operation (COOL,HEAT,DRY or FAN). In this mode the temperature is set automatically according to the room temperature (tested by the temperature sensor which is incorporated in the indoor unit.).
Heat Mode: The heating function allows the air conditioner to heat the room. Press the MODE button to activate the heating function. To optimize the function of the air conditioner, adjust the temperature and the speed by pressing the button indicated.
-
Timer Button: Use these buttons on the control panel and remote to set the Timer.
- Timer Off: The timed stop is programmed by pressing TIMER button. Set the rest time by pressing the button “+” or “-” until the rest time displayed is to your liking then press the TIMER button again.
- Timer On: When the unit is off, press TIMER button at the first time, set the temperature with pressing the button “+” or “-” . Press TIMER button at the second time, set the rest time with pressing the button “+” or “-” . Press TIMER button at the third time, confirm the setting, then the rest time to next automatic switching-on could be read on the display of the machine. Note: It can be set to automatically turn off or on in 0.5-24 hours. Each press of the “+” “-” buttons will increase or decrease the timer. The Timer can be set in 0.5 hours increment below 10 hours and 1 hour increment for 10 hours or above. The SET light will turn on while setting. To cancel the set function, press the TIMER button again.
-
Money Saver Button: When the unit is in Money Saver mode, the light will turn on. In Money Saver mode, the unit will turn off once the room is cooled to the user-set temperature. The unit will turn back on when the room temperature rises above the user-set temperature. Before the compressor starts,the fan motor will run for a while, then it will stop for a while, and will repeat to provide a much more comfortable feeling and save energy.
-
Sleep Button: Press the SLEEP button, all of the display lights will turn off after a while, but the Sleep light is always on. In SLEEP mode, the air conditioner will automatically adjust the temperature and fan speed to make the room more comfortable during the night. The set temperature will automatically raise every 30-60 minutes, and at most change six times until the set temperature is 81 or 82°F. for cooling and 75 or 76°F for heating.
-
Fan Speed Button: Press the FAN SPEED button to choose the fan speed options. You can choose Hi, Med, Lo or auto speed in COOL mode or HEAT mode and choose Hi, Med, Lo in FAN mode.
-
Filter Button: When the Filter Check light is on, you can turn off the light by pressing the Filter Check button. After the fan motor works for 500 total hours, the Filter Check light will turn on to remind the user to clean the filter. When the Filter Check light is off, it is not necessary to press the Filter Check button.
-
Directional Louvers: To direct the airflow, use the horizontal wheel to control the horizontal direction, and use the air deflectors to control the vertical direction.
STARTUP AND OPERATION
J.2 Remote Control Operation
-
Power: Turn the air conditioner on and off. This button will clear the TIMER setting.
-
MODE: Press the button to select the mode of operation, AUTO, COOL, DRY, FAN ONLY, HEAT.
Note: The HEAT mode is only for some heating models. If you do not need it, press the MODE button for more than 5 seconds to delete the HEAT function, and the COOL mode will be selected automatically. Press the MODE again for more than 5 seconds to add the HEAT function, and the HEAT mode will be selected automatically. -
+ And – : Use these buttons to increase or decrease the setting Temperature or Timer. Setting temperature range: 61 ~88°F or 16 ~31°C .
Note: After setting temperature with remote using the + and – buttons, both the remote display and the unit display will automatically turn off after a short time. This does not affect the unit operation. -
TURBO: When the remote is ON, press the button to activate the TURBO function, under AUTO/COOL/FAN ONLY mode. Press again to cancel the TURBO function, and the fan speed will change to pre-setting before.
Note: °F and °C change: After inserting the batteries, in the off state within 3 minutes, press the TURBO button for more than 5 seconds to switch the Fahrenheit (°F) or Celsius (°C) degree display. -
DISPLAY: When the unit is ON, press the button, to switch off/on all lights or LED display. And this function will be canceled when changing mode.
-
TIMER: Use the button to set the TIMER, or cancel the TIMER.
TIMER OFF: When the unit is ON, the timed OFF is programmed by pressing TIMER button, the remote will display 6 hours of pre-setting at first. Set the rest time by pressing the button or until the needed rest time display, then press TIMER button again to confirm.
TIMER ON: When the unit is OFF, the timed ON is programmed by pressing TIMER button, the remote will display 6 hours pre-setting at first. Set the rest time by pressing the button or until the needed rest time display, then press TIMER button again to confirm. Later, the remote screen will keep display [TIMER] icon.
Note: When TIMER ON, it cannot select Sleep mode, but can pre-set Mode, temperature, fan speed, ECO. -
SLEEP: Press the SLEEP button, all of the display lights will turn off after a while, but the Sleep light is always on. In SLEEP mode, the air conditioner will automatically adjust the temperature and fan speed to make the room more comfortable during the night. The set temperature will automatically raise every 30-60 minutes and at most change six times until the set temperature is 81 or 82°F. This function can be selected when COOL or HEAT mode.
-
FAN SPEED: Press the FAN SPEED button to choose the fan speed options. You can choose Hi, Med, Lo or Auto speed in COOL or HEAT mode and choose Hi, Med, Lo in FAN mode. When DRY mode, it is only Low fan speed.
-
MONEY SAVER: When the unit is in COOL mode, press the button to MONEY SAVER function. In MONEY SAVER mode, the unit will turn off once the room is cooled to the user set temperature. The unit will turn back on when the room temperature rises above the user set temperature. Before the compressor starts, the fan motor will run for 20 sec., then it will stop for 10 min., and will repeat to provide a much more comfortable feeling and save energy.
-
Child Lock: Press the + or – button for more than 2 seconds to lock or unlock the remote controller. When locked, each function button is noTuseful, and the lock icon will flash when any button is pressed.
Battery size: AAA
Note: Do not mix old and new batteries or different types of AAA batteries .
This is a warm weather appliance
Your air conditioner is designed to cool in warm weather when the outside temperature is above 60 °F (15.6 °C) and below 115 °F (46.1 °C), so it won’t cool a room if it is already cool outside. Condensation is normal Air conditioners actually pump the heat and humidity from your room to the outside. Humidity becomes water, and your air conditioner will use most of the water to keep the outside coil cool. If there is excessive humidity, there may be excess water that will drip outside. This is normal operation.
Frosting
This usually occurs because of insufficient airflow across the coils, a dirty filter, cool damp weather, or all these. Set the SYSTEM mode to FAN ONLY and the frost will disappear. Setting the thermostat a little warmer will probably prevent the frosting from recurring.
Noises
All air conditioners make some noise. Friedrich units are designed to operate as quietly as possible. An air conditioner mounted in a wall is quieter than one mounted in a window. It is important to ensure that the chassis seal gasket is properly installed (refer to the Installation Instructions).
L. WiFi
Use a QR Reader on your phone to Scan this QR Code. It will take you to the Wifi Instructions page of our website.
TROUBLESHOOTING
COMPLAINT | CAUSE | SOLUTION |
---|
Unit does not operate.
| • The unit is turned to the off position, or
the thermostat is satisfied.
| • Turn the unit to the on position and raise or lower temperature
setting (as appropriate) to call for operation.
• The LCDI power cord is unplugged.| • Plug into a properly
grounded 3 prong receptacle. See “Electrical Rating Tables” on Page 6 for the
proper receptacle type for your unit.
• The LCDI power cord has tripped (Reset button has popped out).| •
Press and release RESET (Listen for click. Reset button latches and remains
in.) to resume operation.
• The circuit breaker has tripped or the supply circuit fuse has
blown.| • Reset the circuit breaker, or replace the fuse as
applicable. If the problem continues, contact a licensed electrician.
• There has been a local power failure.| • The unit will
resume normal operation once power has been restored.
Unit Trips Circuit Breaker or
Blows Fuses.
| • Other appliances are being used on the same circuit.| •
The unit requires a dedicated outlet circuit, not shared with other
appliances.
• An extension cord is being used.| • Do NOT use an
extension cord with this or any other air conditioner.
• The circuit breaker or time-delay fuse is not of the proper
rating.| • Replace with a circuit breaker or time-delay fuse of the
proper rating. See “Elec- trical Rating Tables” on Page 6 for the proper
circuit breaker/ fuse rating for your unit. If the problem continues, contact
a licensed electrician.
LCDI Power Cord Trips (Reset Button Pops Out).
| • The LCDI power cord can trip (Reset button pops out) due to
disturbances on your power supply line.| • Press and release RESET
(Listen for click. Reset button latches and remains in.) to resume normal
operation.
• Electrical overload, overheating, or cord pinching can trip (Reset
button pops out) the LCDI power cord.| • Once the problem has been
determined and corrected, press and release RESET (Listen for click. Reset
button latches and remains in.) to resume normal operation.
NOTE: **** A damaged power supply cord must be replaced with a new power
supply cord obtained from the product manufacturer and must not be repaired.
Unit Does Not Cool Room Sufficiently, or Cycles On And Off Too Frequently.
| • The return/ discharge air grille is blocked.| • Ensure
that the return and/ or discharge air paths are not blocked by curtains,
blinds, furniture, etc.
• Windows or doors to the outside are open.| • Ensure that
all windows and doors are closed.
• The temperature is not set at a cool enough enough setting.| •
Adjust the Temperature control to a cooler or warmer setting as necessary.
• The filter is dirty or obstructed.| • Clean the filter,
(see Routine Maintenance), or remove obstruction.
• The indoor coil or outdoor coil is dirty or obstructed.| •
Clean the coils, (see Routine Maintenance), or remove obstruction.
• There is excessive heat or moisture (cooking, showers, etc.) in the
room.| • Be sure to use exhaust vent fans while cooking or bathing
and, if possible, try not to use heat producing appliances during the hottest
part of the day.
• The temperature of the room you are trying to cool is extremely
hot.| • Allow additional time for the air conditioner to cool off a
very hot room.
Unit Does Not Cool Room Sufficiently, or Cycles On And Off Too Frequently (continued).
| • The outside temperature is below 60 °F (16 °C).| • Do
not try to operate your air conditioner in the cooling mode when the outside
temperature is below 60 °F (16 °C). The unit will not cool properly, and the
unit may be damaged.
• The digital control is set to fan cycling mode.| • Since
the fan does not circulate the room air continuously at this setting, the room
air does not mix as well and hot (or cold) spots may result. Using the con-
tinuous fan setting is recommended to obtain optimum comfort levels.
• The air conditioner has insufficient cooling capacity to match the
heat gain of the room.| • Check the cooling capacity of your unit to
ensure it is properly sized for the room in which it is installed. Room air
conditioners are not designed to cool multiple rooms.
• The air conditioner has insufficient heating capacity to match the
heat loss of the room.| • Check the heating capacity of your unit.
Air conditioners are sized to meet the cooling load, and heater size is then
selected to meet the heating load. In extreme northern climates, room air
conditioners may not be able to be used as a primary source of heat.
COMPLAINT| CAUSE| SOLUTION
---|---|---
Unit Runs Too Much.
| • This may be due to an excessive heat load in the room.| •
If there are heat producing appliances in use in the room, or if the room is
heavily occupied, the unit will need to run longer to remove the additional
heat.
• It may also be due to an improperly sized unit.| • Be sure
to use exhaust vent fans while cooking or bathing and, if possible, try not to
use heat producing appliances during the hottest part of the day.
• This may be normal for higher efficiency
(EER) air conditioners.
| • The use of higher efficiency components in your new air
conditioner may result in the unit running longer than you feel it should.
This may be more apparent, if it replaced an older, less efficient, model. The
actual energy usage, however, will be significantly less when compared to
older models.
• You may notice that the discharge air temperature of your new air
conditioner may not seem as cold as you may be accustomed to from older units.
This does not; however, indicate a reduction in the cooling capacity of the
unit.| ****
• The energy efficiency ratio (EER) and cooling capacity rating (Btu/ h) listed on the unit’s rating plate are both agency certified.
INFORMATION FOR THE OWNER
R.1 Routine Maintenance
Coils & Chassis
NOTE: Do not use a caustic cleaning agent on coils or base pan. Use a
biodegradable cleaning agent and degreaser. The use of harsh cleaning
materials may lead to deterioration of the aluminum fins or the coil end
plates. The indoor coil and outdoor coils and base pan should be inspected
periodically (annually or semi-annually) and cleaned of all debris (lint,
dirt, leaves, paper, etc.) as necessary. Under extreme conditions, more
frequent cleaning may be required. Clean the coils with and base pan with a
coil comb or soft brush and compressed air or vacuum. A low pressure washer
device may also be used; however, you must be careful not to bend the aluminum
fin pack. Use a sweeping up and down motion in the direction of the vertical
aluminum fin pack when pressure cleaning coils.
NOTE: It is extremely important to insure that none of the electricaland/ or
electronic parts of the unit get wet when cleaning. Be sure to cover all
electrical components to protect them from water or spray.
Decorative Front
Use a damp (not wet) cloth when cleaning the control area to prevent water from entering the unit, and possibly damaging the electronic control. The decorative front and the cabinet can be cleaned with warm water and a mild liquid detergent. Do NOT use solvents or hydrocarbon based cleaners such as acetone, naphtha, gasoline, benzene, etc. The indoor coil can be vacuumed with a dusting attachment if it appears to be dirty. DO NOT BEND FINS. The outdoor coil can be gently sprayed with a garden hose.
Air Filter
The air filter should be inspected weekly and cleaned if needed by vacuuming with a dust attachment or by cleaning in the sink using warm water and a mild dishwashing detergent. Dry the filter thoroughly before reinstalling. Use caution, the coil surface can be sharp. Blower Wheel / Housing / Condensor Fan / Shroud WARNING: Service of this product (aside from filter maintenance) shall only be performed by trained service personnel. Refer to the Service Manual for procedures on how to inspect and maintain the interior of the unit and its components. A QR code is located in section A.4 which will help you locate the service manual online. Inspect the indoor blower and its housing, evaporator blade, condenser fan blade and condenser shroud periodically (yearly or bi-yearly) and clean of all debris (lint, dirt, mold, fungus, etc.). Under extreme conditions, more frequent cleaning may be necessary. Clean the blower housing area and blower wheel with an antibacterial / antifungal cleaner. Use a biodegradable cleaning agent and degreaser on condenser fan and condenser shroud. Use warm or cold water when rinsing these items. Allow all items to dry thoroughly before reinstalling them.
Warranty
Friedrich Air Conditioning Company
- 10001 Reunion Place, Suite 500
- San Antonio, TX 78216
- 800.541.6645
- www.friedrich.com
ROOM AIR CONDITIONERS LIMITED WARRANTY FIRST YEAR
ANY PART: If any part supplied by FRIEDRICH fails because of a defect in workmanship or material within twelve months from date of original purchase, FRIEDRICH will repair the product at no charge, provided room air conditioner is reasonably accessible for service. Any additional labor cost for removing inaccessible units and/or charges for mileage related to travel by a Service Agency that exceeds 25 miles one way will be the responsibility of the owner. This remedy is expressly agreed to be the exclusive remedy within twelve months from the date of the original purchase.
SECOND THROUGH FIFTH YEAR
SEALED REFRIGERANT SYSTEM: If the Sealed Refrigeration System (defined for this purpose as the compressor, condenser coil, evaporator coil, reversing valve, check valve, capillary, filter drier, and all interconnecting tubing) supplied by FRIEDRICH in your Room Air Conditioner fails because of a defect in workmanship or material within sixty months from date of purchase, FRIEDRICH will pay a labor allowance and parts necessary to repair the Sealed Refrigeration System; PROVIDED FRIEDRICH will not pay the cost of diagnosis of the problem, removal, freight charges, and transportation of the air conditioner to and from the Service Agency, and the reinstallation charges associated with repair of the Sealed Refrigeration System. All such cost will be the sole responsibility of the owner. This remedy is expressly agreed to be the exclusive remedy within sixty months from the date of the original purchase.
APPLICABILITY AND LIMITATIONS: This warranty is applicable only to units retained within the Fifty States of the U.S.A., District of Columbia, and Canada. This warranty is not applicable to:
- 1. Air filters, fuses, batteries and the front grille removal tool.
- Products on which the model and serial numbers have been removed.
- Products which have defects or damage which results from improper installation, wiring, electrical current characteristics, or maintenance: or caused by accident, misuse or abuse, fire, flood, alterations and/or misapplication of the product and/or units installed in a corrosive atmosphere, default or delay in performance caused by war, government restrictions or restraints, strikes, material shortages beyond the control of FRIEDRICH, or acts of God.
OBTAINING WARRANTY PERFORMANCE:
Service will be provided by the FRIEDRICH Authorized Dealer or Service Organization in your area. They are listed in the Yellow Pages. If assistance is required in obtaining warranty performance, write to: Room Air Conditioner Service Manager (the Friedrich address is at the top of this warranty) or email tac@friedrich.com.
LIMITATIONS: THIS WARRANTY IS GIVEN IN LIEU OF ALL OTHER WARRANTIES. Anything in the warranty notwithstanding, ANY IMPLIED WARRANTIES OF FITNESS FOR PARTICULAR PURPOSE AND/OR MERCHANTABILITY SHALL BE LIMITED TO THE DURATION OF THIS EXPRESS WARRANTY. MANUFACTURER EXPRESSLY DISCLAIMS AND PE ARE WAR CAT
EXCLUDES ANY LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGE FOR BREACH OF ANY EXPRESSED OR IMPLIED WARRANTY.
Performance of Friedrich’s Warranty obligation is limited to one of the following methods:
- Repair of the unit
- A refund to the customer for the prorated value of the unit based upon the remaining warranty period of the unit.
- Providing a replacement unit of equal value
The method of fulfillment of the warranty obligation is at the sole discretion of Friedrich Air Conditioning.
NOTE: Some states do not allow limitations on how long an implied warranty lasts, or do not allow the limitation or exclusion of consequential or incidental damages, so the foregoing exclusions and limitations may not apply to you. OTHER: This warranty gives you specific legal rights, and you may also have other rights which vary from state to state. PROOF OF PURCHASE: Owner must provide proof of purchase in order to receive any warranty related services. All service calls for explaining the operation of this product will be the sole responsibility of the consumer. All warranty service must be provided by an Authorized FRIEDRICH Service Agency, unless authorized by FRIEDRICH prior to repairs being made.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>