FRIEDRICH Endeavor Line F-Series Plus iM Air Conditioners Instruction Manual

June 13, 2024
FRIEDRICH

FRIEDRICH Endeavor Line F-Series Plus iM Air Conditioners

FRIEDRICH-Endeavor-Line-F-Series-Plus-iM-Air-Conditioners-fig-
\(2\)

Product Information

The Air Conditioners FRA16AZ is part of the EndeavorTM Line F-Series Plus iM Air Conditioners. It is a high-performance air conditioner designed to provide efficient cooling in residential and commercial spaces. The FRA16AZ model is available in four different capacities: 24,000 BTU/HR, 36,000 BTU/HR, 48,000 BTU/HR, and 60,000 BTU/HR. It operates on a voltage of 208/230V and has a SEER2 rating for energy efficiency.

Features and Benefits

  • Efficient cooling performance
  • Multiple capacity options
  • Communicating controls for enhanced functionality
  • Twin Rotary compressor for reliable operation
  • Low ambient control for operation in colder temperatures
  • Compressor sound cover for reduced noise levels
  • Compressor hard start kit for smooth startup
  • Compressor time delay for added protection
  • High and low pressure control for safe operation
  • Liquid Line Solenoid for precise refrigerant flow control

Product Usage Instructions

  1. Select the appropriate model of the FRA16AZ based on the desired cooling capacity for your space.
  2. Ensure that the electrical supply is compatible with the unit’s voltage requirements (208/230V, 1 phase, 60Hz).
  3. Install the air conditioner in a suitable location, following the guidelines provided in the installation manual.
  4. Connect the air conditioner to the power supply using the appropriate electrical connections.
  5. Set the desired temperature and fan speed using the controls on the air conditioner or the remote control (if provided).
  6. Monitor the operation of the air conditioner and make any necessary adjustments to maintain a comfortable indoor environment.
  7. Regularly clean and maintain the air conditioner according to the maintenance instructions provided in the user manual.
  8. If additional accessories are required, refer to the accessories section of the user manual for information on compatible options.

Note: For detailed installation, operation, and maintenance instructions, please refer to the complete user manual provided with the FRA16AZ air conditioner.

FRA16AZ

  • EcoNet® Enabled
  • Cooling Efficiencies up to: 17 SEER2/10.5 EER2
  • Nominal Sizes: 2 to 5 Tons [7.0 to 17.6 kW]
  • Cooling Capacities: 23.5 kBTU to 56 kBTU [6.9 to 16.4 kW]

The Bluetooth® word mark and logos are registered trademarks owned by Bluetooth SIG, Inc. and any use of such marks by Rheem® is under license. Other trademarks and trade names are those of their respective owners.

Features and Benefits

  • EcoNet® Enabled: Automatic system configuration and optimization
  • PlusOne® Diagnostics & Bluetooth®1 Connectivity: With the Friedrich® Contractor & EcoNet® Apps, builtin technology makes advanced set-up, monitoring, troubleshooting and repairing the product easier than ever before
  • PlusOne® Variable Speed Twin Rotary Compressor & Inverter Drive: Features Inverter operation from 40 to 100% capacity with the EcoNet® Smart Thermostat
  • 3-Speed Operation: When installed with a 24V two-stage thermostat
  • Provides Precise Temperature Control: Advanced humidity control and greater efficiency
  • Brushless DC Condenser Motors (BLDC): Enhances reliability and allows for easier serviceability
  • Swept Wing Fan Technology: Features quieter operation and improved unit acoustics
  • 7mm Condenser Copper Coil: Requires less refrigerant allowing for a smaller and lighter footprint while enhancing reliability
  • PlusOne® Expanded Valve Space: 3 in. – 4 in. – 5 in. service valve space—provides a minimum working area of 27-square inches for easier access
  • PlusOne® Triple Service Access: 15 in. wide, industry leading corner service access, two fastener, removable corner and individual louver panels—makes repairs easier and faster

Air Conditioners

FRIEDRICH-Endeavor-Line-F-Series-Plus-iM-Air-
Conditioners-fig- \(3\)

Designates Metric Conversions

AVAILABLE MODELS DESCRIPTION
FRA16AZ24AJ3CA Endeavor™ Line F-Series Plus 2 ton EcoNet® Enabled 3+ Speed

iM Air Conditioner – 208/230/1/60
FRA16AZ36AJ3CA| Endeavor™ Line F-Series Plus 3 ton EcoNet® Enabled 3+ Speed iM Air Conditioner – 208/230/1/60
FRA16AZ48AJ3CA| Endeavor™ Line F-Series Plus 4 ton EcoNet® Enabled 3+ Speed iM Air Conditioner – 208/230/1/60
FRA16AZ60AJ3CA| Endeavor™ Line F-Series Plus 5 ton EcoNet® Enabled 3+ Speed iM Air Conditioner – 208/230/1/60
STANDARD EQUIPMENT

R-410A Refrigerant
Scroll Compressor
Field Installed Filter Drier
Front Seating Service Valves
Internal Pressure Relief Valve
Internal Thermal Overload
Long Line capability
Low Ambient capability with Kit
3-4-5 Expanded Valve Space
Composite Basepan
2 Screw Control Box Access
15″ Access to Internal Components
Quick release louver panel design
No fasteners to remove along bottom
Optimized Venturi Airflow
Single row condenser coil
Powder coated paint
Rust resistant screws
QR code
External gauge ports
Service trays

5T Model SEER2: 15.5 SEER2

General Data

General Data

MODEL NO.| FRA16AZ24AJ3| FRA16AZ36AJ3| FRA16AZ48AJ3| FRA16AZ60AJ3
Nominal Tonnage| 2.0| 3.0| 4.0| 5.0
Valve Connections|
Liquid Line O.D. – in.| 3/8| 3/8| 3/8| 3/8
Suction Line O.D. – in.| 3/4| 3/4| 7/8| 7/8
Refrigerant (R410A) furnished oz.¹| 91| 119| 130| 154
Compressor Type| Twin Rotary
Outdoor Coil|
Net face area – Outer Coil| 11.79| 14.4| 16.42| 17.88
Net face area – Inner Coil| —| —| —| —
Tube diameter – in.| 0.276| 0.276| 0.276| 0.276
Number of rows| 1| 1| 1| 1
Fins per inch| 24| 24| 24| 24
Outdoor Fan|
Diameter – in.| 20| 24| 24| 26
Number of blades| 3| 3| 3| 3
Motor hp| 1/5| 1/5| 1/3| 1/2
CFM| 2883| 4138| 4508| 5348
RPM| 1075| 1000| 1075| 1075
watts| 168| 267| 297| 379
Shipping weight – lbs.| 153| 157| 195| 211
Operating weight – lbs.| 146| 150| 188| 204
Electrical Data
Line Voltage Data (Volts-Phase-Hz)| 208/230-1-60| 208/230-1-60| 208/230-1-60| 208/230-1-60
Maximum overcurrent protection (amps)²| 20| 30| 40| 50
Minimum circuit ampacity³| 12| 20| 25| 32
Compressor|
Rated load amps| 10| 15| 20| 25
Locked rotor amps| 65| 70| 96| 119

  1. Refrigerant charge sufficient for 15 ft. length of refrigerant lines. For longer line set requirements see the installation instructions for information about set length and additional refrigerant charge required.
  2. HACR type circuit breaker of fuse.
  3. Refer to National Electrical Code manual to determine wire, fuse and disconnect size requirements

Accessories

MODEL NO.| FRA16AZ24AJ3| FRA16AZ36AJ3| FRA16AZ48AJ3| FRA16AZ60AJ3
---|---|---|---|---
Compressor crankcase heater*| x| x| x| x
Low ambient control| Factory Installed| Factory Installed| Factory Installed| Factory Installed
Compressor sound cover| Factory Installed| Factory Installed| Factory Installed| Factory Installed
Compressor hard start kit| Factory Installed| Factory Installed| Factory Installed| Factory Installed
Compressor time delay| Factory Installed| Factory Installed| Factory Installed| Factory Installed
Low pressure control| x| x| x| x
High pressure control| Factory Installed| Factory Installed| Factory Installed| Factory Installed
Liquid Line Solenoid (24 VAC, 50/60 Hz)| Solenoid Valve| 200RD2T3TVLC| 200RD2T3TVLC| 200RD2T3TVLC| 200RD2T3TVLC
Solenoid Coil| 61-AMG24V| 61-AMG24V| 61-AMG24V| 61-AMG24V
Liquid Line Solenoid (120/240 VAC, 50/60 Hz)| Solenoid Valve| 200RD2T3TVLC| 200RD2T3TVLC| 200RD2T3TVLC| 200RD2T3TVLC
Solenoid Coil| 61-AMG120/240V| 61-AMG120/240V| 61-AMG120/240V| 61-AMG120/240V

Crankcase Heater recommended with Low Ambient Kit.

Weighted Sound Power Level

UNIT SIZE – VOLTAGE, SERIES| STANDARD RATING (DBA)| TYPICAL OCTAVE BAND SPECTRUM (DBA WITHOUT TONE ADJUSTMENT)| SOUND POWER LEVEL [DB(A)] WITH SOUND BLANKET
---|---|---|---
125| 250| 500| 1000| 2000| 4000| 8000
FRA16AZ24AJ3| 63.3| 35.9| 47.9| 55.3| 53.2| 50.4| 47.1| 43.8| ****



Sound Blankets – Standard

71.7| 46.1| 59.1| 63.2| 60.8| 58.7| 56.5| 47.9
FRA16AZ36AJ3| 61.4| 38.5| 48.0| 53.8| 49.2| 45.9| 47.0| 47.4
72.9| 47.5| 59.5| 64.9| 60.7| 62.6| 57.0| 49.6
FRA16AZ48AJ3| 63.8| 42.3| 45.9| 53.5| 48.9| 45.8| 59.1| 36.4
76.2| 49.4| 61.4| 68.1| 53.9| 60.8| 57.4| 48.5
FRA16AZ60AJ3| 65.7| 39.7| 49.0| 58.2| 54.5| 52.2| 53.8| 41.3
76.7| 49.3| 64.6| 68.1| 65.1| 62.6| 58.6| 53.0

NOTE : Tested by AHRI Standard 270-08 (not listed in AHRI)

Unit Dimensions


MODEL NO.

| OPERATING| SHIPPING
---|---|---
H (Height)| L (Length)| W (Width)| H (Height)| L (Length)| W (Width)
INCHES| mm| INCHES| mm| INCHES| mm| INCHES| mm| INCHES| mm| INCHES| mm
FRA16AZ24AJ3| 27.00| 686| 29.75| 756| 29.75| 756| 28.50| 724| 32.38| 822| 32.38| 822
FRA16AZ36AJ3| 27.00| 686| 33.75| 857| 33.75| 857| 28.50| 724| 36.38| 924| 36.38| 924
FRA16AZ48AJ3| 31.00| 787| 33.75| 857| 33.75| 857| 32.50| 826| 36.38| 924| 36.38| 924
FRA16AZ60AJ3| 31.00| 787| 35.75| 908| 35.75| 908| 32.50| 826| 38.38| 975| 38.38| 975

FRIEDRICH-Endeavor-Line-F-Series-Plus-iM-Air-Conditioners-fig-
\(4\)

Designates Metric Conversions

CLEARANCES

FRIEDRICH-Endeavor-Line-F-Series-Plus-iM-Air-Conditioners-
fig- \(5\)

NOTE : NUMBERS IN () = mm
IMPORTANT : When installing multiple units in an alcove, roof well or partially enclosed area, ensure there is adequate ventilation to prevent re- circulation of discharge air

Control Wiring

FRIEDRICH-Endeavor-Line-F-Series-Plus-iM-Air-
Conditioners-fig- \(6\)

Application Guidelines

  1. Intended for outdoor installation with free air inlet and outlet. Outdoor fan external static pressure available is less than 0.01 -in. wc.
  2. Minimum outdoor operation air temperature for cooling mode without low-ambient operation accessory is 55°F (12.8°C).
  3. Maximum outdoor operating air temperature is 125°F (51.7°C).
  4. For reliable operation, unit should be level in all horizontal planes.
  5. Use only copper wire for electric connections at unit. Aluminum and clad aluminum are not acceptable for the type of connector provided.
  6. Do not apply capillary tube indoor coils to these units.
  7. Factory-supplied filter drier must be installed.

Refrigerant Line Size Information

15/16 SEER2 VARIABLE SPEED AIR CONDITIONERS



UNIT SIZE

| ****

ALLOWABLE LIQUID LINE SIZE

| ****

ALLOWABLE VAPOR LINE SIZE

| OUTDOOR UNIT ABOVE OR BELOW INDOOR UNIT EQUIVALENT LENGTH (FEET)
< 25| 26-50| 51-75| 76-100| 101-125| 126-150
MAXIMUM VERTICAL SEPARATION / CAPACITY MULTIPLIER



2.0 Ton

**SEE NOTE 3

| 1/4″| 5/8″| 25/1.00| 50/0.99| 32/0.98| 40/0.97| NR| NR
5/16″| 5/8″| 25/1.00| 50/0.99| 50/0.98| 50/0.97| 50/0.96| 50/0.95
3/8″| 5/8″| 25/1.00| 50/0.99| 50/0.98| 50/0.97| 50/0.96| 50/0.95
1/4″| 3/4″| 25/1.00| 50/1.00| 32/0.99| 40/0.99| NR| NR
5/16″| 3/4″
| 25/1.00| 50/1.00| 50/0.99| 50/0.99| 50/0.99| 50/0.98
3/8″| 3/4″**| 25/1.00| 50/1.00| 50/0.99| 50/0.99| 50/0.99| 50/0.98



3 Ton

| 5/16″| 5/8″| 25/0.99| 50/0.97| 50/0.95| 50/0.93| 37/0.91| NR
3/8″| 5/8″| 25/0.99| 50/0.97| 50/0.95| 50/0.93| 50/0.91| NR
5/16″| 3/4″| 25/1.00| 50/0.99| 50/0.99| 50/0.98| 37/0.97| 22/0.96
3/8″| 3/4″| 25/1.00| 50/0.99| 50/0.99| 50/0.98| 50/0.97| 50/0.96
1/2″| 3/4″| 25/1.00| 50/0.99| 50/0.99| 50/0.98| 50/0.97| 50/0.96



4 Ton

| 3/8″| 3/4″| 25/0.99| 50/0.98| 50/0.97| 50/0.96| 50/0.94| 50/0.93
1/2″| 3/4″| 25/0.99| 50/0.98| 50/0.97| 50/0.96| 50/0.94| 50/0.93
3/8″| 7/8″| 25/1.00| 50/0.99| 50/0.99| 50/0.98| 50/0.98| 50/0.97
1/2″| 7/8″| 25/1.00| 50/0.99| 50/0.99| 50/0.98| 50/0.98| 50/0.97



5 Ton

| 3/8″| 3/4″| 25/0.99| 50/0.97| 50/0.95| 50/0.93| 50/0.91| NR
1/2″| 3/4″| 25/0.99| 50/0.97| 50/0.95| 50/0.93| 50/0.91| NR
3/8″| 7/8″| 25/1.00| 50/0.99| 50/0.98| 50/0.98| 50/0.97| 38/0.96
1/2″| 7/8″| 25/1.00| 50/0.99| 50/0.98| 50/0.98| 50/0.97| 50/0.96

NOTES:

  1. Do not exceed 150 ft. linear line length.
  2. Do not exceed 50 ft. vertical separation if outdoor unit is above indoor unit.
  3. 3/4″ suction line should only be used for 2 ton systems if outdoor unit is below or at same level as indoor to assure proper oil return.
  4. Always use the smallest liquid line allowable to minimize refrigerant charge.
  5. Applications shaded in light gray indicate capacity multipliers between 0.90 and 0.96 which are not recommended, but are allowed.
  6. Applications shaded in dark gray are not recommended due to excessive liquid or suction pressure drop

15/16 SEER2 VARIABLE SPEED AIR CONDITIONERS



UNIT SIZE

| ****

ALLOWABLE LIQUID LINE SIZE

| ****

ALLOWABLE VAPOR LINE SIZE

| OUTDOOR UNIT ABOVE OR BELOW INDOOR UNIT EQUIVALENT LENGTH (METERS)
< 25| 26-50| 51-75| 76-100| 101-125| 126-150
MAXIMUM VERTICAL SEPARATION / CAPACITY MULTIPLIER



2.0 Ton

**SEE NOTE 3

| 6.35 [1/4]| 15.88 [5/8]| 8/1.00| 15/0.99| 10/0.98| 10/0.97| NR| NR
7.94 [5/16]| 15.88 [5/8]| 8/1.00| 15/0.99| 15/0.98| 15/0.97| 15/0.96| 15/0.95
9.53 [3/8]| 15.88 [5/8]| 8/1.00| 15/0.99| 15/0.98| 15/0.97| 15/0.96| 15/0.95
6.35 [1/4]| 19.05 [3/4]| 8/1.00| 15/0.99| 10/0.99| 12/0.99| NR| NR
7.94 [5/16]| 19.05 [3/4]
| 8/1.00| 15/0.99| 15/0.99| 15/0.99| 15/0.99| 15/0.98
9.53 [3/8]| 19.05 [3/4]**| 8/1.00| 15/0.99| 15/0.99| 15/0.99| 15/0.99| 15/0.98



3 Ton

| 7.94 [5/16]| 15.88 [5/8]| 8/0.99| 15/0.97| 15/0.95| 15/0.93| 11/0.91| NR
9.53 [3/8]| 15.88 [5/8]| 8/0.99| 15/0.97| 15/0.95| 15/0.93| 15/0.91| NR
7.94 [5/16]| 19.05 [3/4]| 8/1.00| 15/0.99| 15/0.99| 15/0.98| 11/0.97| 7/0.96
9.53 [3/8]| 19.05 [3/4]| 8/1.00| 15/0.99| 15/0.99| 15/0.98| 15/0.97| 15/0.96
12.7 [1/2]| 19.05 [3/4]| 8/1.00| 15/0.99| 15/0.99| 15/0.98| 15/0.97| 15/0.96



4 Ton

| 9.53 [3/8]| 19.05 [3/4]| 8/0.99| 15/0.98| 15/0.97| 15/0.96| 15/0.94| 15/0.93
12.7 [1/2]| 19.05 [3/4]| 8/0.99| 15/0.98| 15/0.97| 15/0.96| 15/0.94| 15/0.93
9.53 [3/8]| 22.23 [7/8]| 8/1.00| 15/0.99| 15/0.99| 15/0.98| 15/0.98| 15/0.97
12.7 [1/2]| 22.23 [7/8]| 8/1.00| 15/0.99| 15/0.99| 15/0.98| 15/0.98| 15/0.97



5 Ton

| 9.53 [3/8]| 19.05 [3/4]| 8/0.99| 15/0.97| 15/0.95| 15/0.93| 15/0.91| NR
12.7 [1/2]| 19.05 [3/4]| 8/0.99| 15/0.97| 15/0.95| 15/0.93| 15/0.91| NR
9.53 [3/8]| 22.23 [7/8]| 8/1.00| 15/0.99| 15/0.98| 15/0.98| 15/0.97| 12/0.96
12.7 [1/2]| 22.23 [7/8]| 8/1.00| 15/0.99| 15/0.98| 15/0.98| 15/0.97| 15/0.97

NOTES:

  1. Do not exceed 46 meters linear line length.
  2. Do not exceed 15 meters vertical separation between indoor and outdoor units.
  3. 19.05mm [3/4″] vapor line should only be used for 2 ton systems if outdoor unit is below or at same level as indoor unit to assure proper oil return.
  4. Always use the smallest liquid line allowable to minimize refrigerant charge.
  5. Applications shaded in light gray indicate capacity multipliers between 0.90 and 0.96 which are not recommended, but are allowed.
  6. Applications shaded in dark gray are not recommended due to excessive liquid or suction pressure drop.

ADDITIONAL OIL, OZ.

LINESET LENGTH| 50| 60| 70| 80| 90| 100| 110| 120| 130| 140| 150
2T| N/A| N/A| N/A| N/A| N/A| 1| 2| 3| 5| 6| 7
3T| N/A| N/A| N/A| N/A| N/A| N/A| 1| 2| 3| 5| 6
4T| N/A| N/A| N/A| N/A| N/A| N/A| N/A| N/A| N/A| N/A| N/A
5T| N/A| N/A| N/A| N/A| N/A| N/A| N/A| N/A| N/A| N/A| N/A

Performance Data @ AHRI Standard Conditions – Cooling

DESIGNATED TESTED COMBINATION (DTC)

OUTDOOR UNIT| INDOOR COIL| TOTAL CAPACITY BTU/H [KW]| NET SENSIBLE BTU/H [KW]| NET LATENT BTU/H [KW]| SEER2| EER2| INDOOR CFM [L/S]
FRA16AZ24AJ3C| RH3VZ2417STACN| 22,800 [6.7]| 17,600 [5.2]| 5,200 [1.5]| 16.0| 10.5| 750 [354.0]
FRA16AZ36AJ3C| RH3VZ3617STACN| 34,200 [10.0]| 26,600 [7.8]| 7,600 [2.2]| 16.0| 10.5| 1,125 [530.9]
FRA16AZ48AJ3C| RH3VZ4821STACN| 45,500 [13.3]| 35,500 [10.4]| 10,000 [2.9]| 16.0| 10.5| 1,425 [672.5]
FRA16AZ60AJ3C| RH3VZ6024STACN| 55,500 [16.3]| 43,000 [12.6]| 12,500 [3.7]| 15.5| 9.8| 1,675 [790.5]

NOTE : This data includes DTC (Designated Test Combination) ratings and is for reference purposes only. A full listing of official ratings and system match-ups, along with downloadable certificates, can be accessed from the AHRI website: www.ahridirectory.org.
Designates Metric Conversions

Integrated Controls

EcoNet® is smart, technology that allows Heating and Cooling, products to communicate with each other on one integrated network.

THE ECONET® SMART THERMOSTAT

  • BUILT-IN WIFI
  • 4.3″ LCD TOUCH SCREEN
  • LOCAL WEATHER – Current conditions plus 6-day forecast
  • 5 OPERATING MODES – Heat, Cool, Auto, Emergency Heat and Fan Only
  • 7-DAY PROGRAMMABLE SCHEDULE – Offers comfort without thought
  • ONE-TOUCH AWAY – Quickly switch to your energy-saving away preferences
  • VACATION SCHEDULING – Allows you to save while you’re away and come home to comfort
  • STANDBY SCREEN – Displays indoor temperature and current weather

OPERATIONAL FEATURES

  • AUTOMATIC CHANGEOVER – Transitions between heating and cooling automatically to keep the house comfortable
  • INTEGRATED WATER CONTROL – Enables easy water heater management
  • SMOOTH ARRIVAL – Prompts the system to start ahead of schedule to ensure the home is at the desired temperature at the scheduled time
  • HUMIDITY CONTROL – Supports humidifier accessories or over-cool-based dehumidification
  • DETAILED OPERATING STATUS – View pertinent equipment status information and run times
  • CONTINUOUS FAN – Offers 5 speeds (Low, Medium Low, Medium, Medium High, High)
  • SHORT-CYCLE PROTECTION – Avoids damage to equipment from short-run cycles

MONITORING & REMOTE CONTROL FEATURES

  • ACTIVE MONITORING – Alerts to problems that need immediate attention
  • REMOTE CONTROL – Allows adjusting of comfort and settings from anywhere using a mobile device
  • SERVICE ALERTS – Sends routine maintenance reminders
  • AIR FILTER MONITORING – Detects when it’s time to replace the air filter
  • ALARM HISTORY – Displays time-stamped alarm codes with clear descriptions

WARRANTY

GENERAL TERMS OF LIMITED WARRANTY

Friedrich® will furnish a replacement for any part of this product that fails in normal use and service within the applicable period stated, in accordance with the terms of the limited warranty.
For complete details of the Limited and Conditional Warranties, including applicable terms and conditions, contact your local contractor or the Manufacturer for a copy of the product warranty certificate.

Conditional Unit Replacement

  • (Registration Required)……………………………. Ten (10) Years
  • Parts……………………………………………………Ten (10) Years

Before proceeding with installation, refer to installation instructions packaged with each model, as well as complying with all Federal, State, Provincial, and Local codes, regulations, and practices.
© 2023 Rheem Manufacturing Company. Friedrich trademarks are owned by Rheem Manufacturing Company. In keeping with its policy of continuous progress and product improvement, Friedrich reserves the right to make changes without notice.

Friedrich
5600 Old Greenwood Road
Fort Smith, Arkansas 72908
www.friedrich.com

Friedrich
125 Edgeware Road, Unit 1
Brampton, Ontario
L6Y 0P5
PRINTED IN U.S.A. 7/23 QG FORM NO. AFR-335

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

FRIEDRICH User Manuals

Related Manuals