COOL ONLY
115 volt- 6,000 to 13,600 Btu
230 volt- 12,000 to 35,000 Btu
EFFICIENCY: EERs up to 12.2
HEAT PUMPS
115 volt- 10,000 Btu COOLING
8,800 Btu HEATING
230 volt- 24,000 Btu COOLING
9,800-21,000 Btu HEATING
EFFICIENCY: EERs up to 10.9
ELECTRIC HEAT MODELS
115 volt- 7,700 Btu COOLING
4,000 Btu HEATING
230 volt- 12,000 to 35,000 Btu COOLING
10,700 to 17,300 Btu HEATING
EFFICIENCY: EERs up to 11.1
FEATURES
Control with FriedrichConnect® app or by voice command
Customizable, 7-day schedules
Advanced grouping of multiple units
24-hour timer
-
Up to 4 cooling/4 fan-only speeds
-
Auto fan
-
Auto-changeover between cooling and heating (Kühl®+ models except KEQ08)
-
Auto restart
-
8-way air flow control
-
Control panel lockout (ON/OFF)
-
QuietMaster® technology for up to 45% quieter operation**
-
Steel inner wall and extra dense insulation blocks outdoor noise
-
Vibration isolating design and components reduce operating noise
-
FreshAire® IAQ ready- optional MERV 13filter captures particles down to 1 micronin size
-
Fresh air intake/stale air exhaust vent*
-
Washable air filter
-
Carbon filter absorbs odors and reduces ozone and volatile organic compounds (VOCs)
-
Standard dual filtration provides air filtration as high as MERV 6
-
Check filter reminder
-
Robust 20 gauge steel cabinet
-
Solid-steel blower housing offers enhanced protection
-
Totally enclosed commercial grade fan motor
-
Durable base pan and steel inner walls
-
Aluminum end plates
-
High-tech aluminum fins with rifled copper tubing
ENERGY STAR® qualified models,
Kühl®+ heat pumps provide energy efficient cooling and heating
Temperature limiting for maximum low and high temperature settings
Recyclable packaging -
EntryGard® anti-intrusion protection secures the chassis to the sleeve
-
Power cord leakage current protected
-
Insect barrier*
-
Aluminum rear grille protects the outdoor coil from debris and vandalism
-
Install in a window or thru-the-wall
-
Slideout chassis for more permanent installation, easier maintenance access
-
Patented firm grip handles for easier chassis installation and removal
-
Includes heavy duty window installation hardware (optional accessory on Kühl®+ models sold separately)
-
Hardboard side panels for a more permanent installation (heavy duty side curtains on KCQ and KEQ models)
-
Power cord can run either left or right
ACCESSORIES
MERV 13 FILTER / FILTER BRACKETS
FreshAire MERV 13 filtration is effective at capturing and removing
microorganisms from the air, which according to ASHRAE, the leading authority
on the science behind advanced indoor air quality, include harmful airborne
viruses. Maintaining the best indoor air quality possible requires that you
prevent harmful pollutants from circulating throughout the space. One way to
prevent this is to trap the pollutants with mechancial filtration. Kühl® is
the only window air conditioner that can utilize on optional MERV 13 air
filter, which is at least 85% efficient at capturing particles between 1 and 3
microns in size and up to 50% efficient in filtering particles between 0.30
and 1 micron in size such as bacteria and sneeze nuclei.
Based on ASHRAE Guidance for Building Operations During the COVID-19 Pandemic
Model No. | UPC | Description |
---|---|---|
KMFB1PK | 724587440553 | Kühl MERV filter bracket 1 pack |
KMFBQ1PK | 724587440546 | Kühl Q MERV filter bracket 1 pack |
KMFQ3PK | 724587440560 | Kühl MERV filter – Q chassis 3 pack |
KMFS3PK | 724587440577 | Kühl MERV filter – S chassis 3 pack |
KMFM3PK | 724587440584 | Kühl MERV filter – M chassis 3 pack |
KMFL3PK | 724587440591 | Kühl MERV filter – L chassis 3 pack |
Filter bracket
required for MERV 13 filter installation.
Minimum bracket order of 24.
Minimum filter order quantity of eight.
*WINDOW MOUNTING KITS: KÜHL+*
Window kits are included with cooling only models, but are an accessory item
for Kühl+ heat/cool models.
Window kits are required for installation of Kühl+ models in a window.
Heat/Cool Models | Kit No. |
---|---|
KEQO8A11A* | KWIKQA |
KES12A33A, KES16A33A, KHS10A10A and KHS12A33A. | KWIKSB |
KEM18A34A and KHM18A34A. | KWIKMB |
KEL24A35B, KEL36A35A and KHL24A35A. | KWIKLB |
- KEQO8A11A window kit KWIKQA does not include window brackets.
DRAIN KIT
Allows field installed drain tube to be installed to the bottom of the sleeve
to route the condensate from the unit.
Model | Kit No. |
---|---|
All Kühl Series Models | DC2 |
PREMIUM CARBON FILTERS
Remove odors and VOCs (volatile organic compounds).
Achieve up to a MERV 6 rating when used with standard filter.
3 pack
Model | Kit No. |
---|---|
KCQ and KEQ | KWCFQ |
KCS, KES and KHS | KWCFS |
KCM, KEM and KHM | KWCFM |
KCL, KEL and KHL | KWCFL |
SPECIFICATIONS
ENERGY STAR® models
- KHS10A10A heat pump operates on 115 volt and is not equipped with supplemental heat. Will not provide heat at temperatures below 40˚F.
Friedrich room air conditioners are designed to operate in outdoor temperatures from 60˚F to 115˚F.
Kühl+ Heat Pump heating information indicates heat pump performance. Kühl+ Electric Heat heating information indicates electric heat strip performance.
For Kühl+ Heat Pump electric heating performance refer to corresponding Kühl+ Electric Heat model.
As an ENERGY STAR® partner, Friedrich Air Conditioning Co. has determined that the selected ENERGY STAR® models meet the ENERGY STAR® guidelines for energy efficiency. EER is the unit’s Energy Efficiency Ratio; CEER is the unit’s Combined Energy Efficiency Ratio.
Your energy costs will depend on your utility rates and use. The estimated energy cost is based on an electricity cost of $.13 per kWh.
For more information, visit www.ftc.gov/energy.
Due to continuing research in new energy-saving technology, specifications are subject to change without notice.
INSTALLATION
- Minimum extensions when mounted in a window.
Minimum widths achieved using one side curtain assembly as opposed to both in a standard installation.
NOTE:** S, M and L sleeves may be installed in window with no side kits if properly installed.
CIRCUIT RATING/ BREAKER/ POWER CORD
Model| Circuit Rating
Breaker or
T-D Fuse| Plug Face
(NEMA#)| Power Cord
Length (ft.)| Wall Outlet
Appearance
---|---|---|---|---
All KCQ MODELS. KEQO8A11A.
KCS08A10A, KCS10A10A,
KCS12A10A and KCS14A10A.
KHS10A10A. KCM14A10A.| 125V – 15A| 5 – 15P| 6|
KCS12A30A and KCS16A30A.
KCM18A30A and KCM21A30A.| 250V – 15A| 6 – 15P| 6|
KCL24A30B and KCL28A30A.
KES12A33A and KES16A33A.
KHS12A33A.| 250V – 20A| 6 – 20P| 6|
KCL36A30A. KEM18A34A and
KEL24A35B and KEL36A35A.
KHM18A34A and KHL24A35A.| 250V – 30A| 6 – 30P| 6|
*Feature not available on KCQ and KEQ models
**Based on testing conducted at the Friedrich Design and Development Center in
comparison to leading rotary compressor models
Friedrich Air Conditioning Co. l www.friedrich.com
SPECS_KÜHL_2023 (Rev. 2-19-23)
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>