The Thru-the-wall Air Conditioners are available in two types: Cool Only and Cool with Electric Heat. The Cool Only model is available in 8,000 to 12,000 Btu for 115 volts and 14,000 to 16,000 Btu for 230 volts with EERs up to 10.7 and CEER up to 10.6. The Electric Heat models are available in 8,000 Btu Cooling and 4,200 Btu Heating for 115 volts and 10,000 to 14,000 Btu Cooling and 10,600 Btu Heating for 230 volts with EERs up to 9.7 and CEER up to 9.6. The air conditioner features a Sleep setting and R-32 refrigerant with low global warming potential (GWP) on select models. The product is tested at Friedrich Design and Development Center and is compared to leading rotary compressor models.
Specifications
Model| Cooling Btu| Heating Btu| Volts| Cooling Rated Amps| Cooling Watts|
Heating Amps| Heating Watts| EER| CEER
---|---|---|---|---|---|---|---|---|---
UCT08B10A| 8000| —| 115| 6.9| 755| —| —| 10.7| —
UCT10B10A| 10000| —| 115| 8.3| 940| —| —| 10.7| —
UCT10B30A| 10000| —| 230| 4.5| 940| —| —| 10.7| —
UCT12B10A| 12000| —| 115| 10.1| 1130| —| —| 10.7| —
UCT12B30A| 12000| —| 230| 5.4| 1130| —| —| 10.7| —
UCT14B30A| 14000| —| 230| 7.2| 1490| —| —| 9.4| —
UET08A11A| 8000| 4200| 115| 7.2| 810| —| 1320| 9.7| —
UET10A33A| 10000| 10600| 230| 4.9| 1030| —| 3500| 9.7| —
UET12A33A| 12000| 10600| 230| 5.9| 1230| —| 3500| 9.7| —
UET14A33A| 14000| 10600| 230| 7.2| 1490| —| 3500| 9.4| —
Model
|
UPC
|
Cooling Btu
|
Heating Btu
|
Volts Rated
|
Cooling Amps
|
Cooling Watts
|
Heating Amps
|
Heating Watts
|
EER
|
CEER
| Estimated Yearly Energy Cost|
Moisture Removal Pints/Hr
|
Refrigerant
|
CFM
|
Net Weight Lbs
|
Ship Weight Lbs
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---
UNI-FIT®
Cool Only
UCT08B10A| 724587442342| 8000| —| 115| 6.9| 755| —| —| 10.7| 10.6| $69| 0.80|
R-32| 265| 64| 78
UCT10B10A| 724587442359| 10000| —| 115| 8.3| 940| —| —| 10.7| 10.6| $85| 1.25|
R-32| 247| 74| 86
UCT10B30A| 724587442366| 10000| —| 230| 4.5| 940| —| —| 10.7| 10.6| $85| 1.25|
R-32| 265| 74| 86
UCT12B10A| 724587442373| 12000| —| 115| 10.1| 1130| —| —| 10.6| 10.5| $102|
1.70| R-32| 276| 75| 88
UCT12B30A| 724587442380| 12000| —| 230| 5.4| 1130| —| —| 10.6| 10.5| $102|
1.70| R-32| 265| 75| 88
UCT14B30A| 724587442397| 14000| —| 230| 7.2| 1490| —| —| 9.4| 9.3| $135| 2.15|
R-32| 265| 76| 89
Cool with Electric Heat
UET08A11A| 724587436792| 8000| 4200| 115| 7.2| 810| 12.5| 1320| 9.7| 9.6| $74|
0.75| R410A| 265| 66| 79
UET10A33A| 724587436808| 10000| 10600| 230| 4.9| 1030| 15| 3500| 9.7| 9.6|
$93| 1.2| R410A| 276| 75| 87
UET12A33A| 724587436815| 12000| 10600| 230| 5.9| 1230| 15| 3500| 9.7| 9.6|
$111| 1.65| R410A| 276| 76| 89
UET14A33A| 724587436822| 14000| 10600| 230| 7.2| 1490| 15| 3500| 9.4| 9.3|
$135| 2.15| R410A| 265| 77| 90
Optional Accessories
The air conditioner requires an existing or new sleeve for installation. The Friedrich USC Sleeve ships with the accessories needed for installation in new construction or installation into an existing sleeve. The USC wall sleeve ships with weather panels (2) and grille. The sleeve includes a painted steel inner panel, a painted steel outer panel, and a painted steel standard grille. The product also has an optional extruded brushed aluminum grille called the ARCHITECTURAL GRILLE-UXAA. When installing into an existing sleeve, consult the Installation Section of your Installation/Operation Manual to determine whether or not the grille needs to be replaced and/or a baffle adapter (included with the chassis) should be used.
USC SLEEVE
An existing or new sleeve is required for installation. The Friedrich USC
sleeve ships with the accessories needed for installation in new construction,
or installation into an existing sleeve.
INCLUDED WITH USC SLEEVE
USC wall sleeve ships with weather panels (2) and grille. Sleeve is shown at
right with:
- Painted steel inner panel
- Painted steel outer panel
- Painted steel standard grille
OPTIONAL GRILLE
ARCHITECTURAL GRILLE-UXAA
Optional extruded brushed aluminum grille.
INSTALLATION
SLEEVE/ CHASSIS DIMENSIONS
Model
| ****
Height
| ****
Width
| ****
Depth
| ****
Depth with Front
| ****
Minimum Extension Into Room
| ****
Minimum Extension Outside
| ****
Height
| Thru-the-wall Finished Hole
Width Max. Depth
---|---|---|---|---|---|---|---|---
Uni-Fit®
USC Sleeve| 15 1/2“| 25 7/8“| 16 3/4“| 20 1/2“| –| 1/2“| 15 3/4“| 26 1/8“| 16
1/4“
UCT, UET Chassis| 14 1/2“| 24 1/4“| –| 20 5/16“| 3 3/4“| –| –| –| –
UNIVERSAL FIT
Sleeve Dimensions
|
Friedrich USC Sleeve
|
Amana
|
Carrier (51S
Series)
|
Fedders/ Emerson/ Friedrich WSE
|
Emerson/ Fedders
|
GE/ Hotpoint
|
Whirlpool
|
White-Westinghouse/ Frigidaire/ Carrier (52F Series)
---|---|---|---|---|---|---|---|---
Height| 15 1/2“| 15 5/8“| 16 7/8“| 16 3/4“| 15 3/4“| 15 5/8“| 16 1/2“| 15 1/4“
Width| 25 7/8“| 26″| 25 3/4“| 27″| 26 3/4“| 26″| 25 7/8“| 25 1/2“
Depth| 16 3/4“| 16 7/8“| 18 5/8“| 16 3/4” or 19 3/4“| 15″| 16 7/8“| 17 1/8” or
23″| 16″, 17 1/2” or 22″
PLUG FACE / CIRCUIT RATING / POWER CORD
Uni-Fit®
Model Number
| Circuit Rating Breaker
or T-D Fuse
| ****
Plug Face (NEMA#)
| Power Cord Length (ft.)| ****
Wall Outlet
Appearance
---|---|---|---|---
UCT08B10A, UCT10B10A, UCT12B10A| ****
125V – 15A
| ****
5 – 15P
| ****
6
UCT10B30A, UCT12B30A,
UCT14B30A
| ****
250V – 15A
| ****
6 – 20P
| ****
6
UET08A11A
| ****
125V – 15A
| ****
5 – 15P
| ****
4.75
UET10A33A, UET12 A33A, UET14A33A| ****
250V – 20A
| ****
6 – 20P
| ****
4.75
CARTON DIMENSIONS
Model
| Carton Dimensions Inches Height Width Depth
---|---
Uni-Fit®
USC Sleeve| 17 7/8“| 28″| 19 1/4“
UCT, UET Chassis| 16 3/8“| 27 3/4“| 26 5/8 “
As an Energy Star® partner, Friedrich Air Conditioning Co. has determined that the selected Energy Star® models meet the Energy Star® guidelines for energy efficiency. EER is the unit’s Energy Efficiency Ratio; CEER is the unit’s Combined Energy Efficiency Ratio. Due to continuing research in new energy- saving technology, specifications are subject to change without notice. Your energy costs will depend on your utility rates and use. The estimated energy cost is based on a electricity cost of $.13 per kWh. For more information, visit –www.ftc.gov/energy.