FRIEDRICH FRA18AZ Endeavor Line K-Series iM Air Conditioners User Manual
- June 13, 2024
- FRIEDRICH
Table of Contents
- FRIEDRICH FRA18AZ Endeavor Line K-Series iM Air Conditioners
- Product Information
- Product Usage Instructions
- Features and Benefits
- Air Conditioners
- General Data
- Accessories
- Unit Dimensions
- CLEARANCES
- Control Wiring
- Application Guidelines
- Refrigerant Line Size Information
- Performance Data @ AHRI Standard Conditions – Cooling
- Integrated Controls
- OPERATIONAL FEATURES
- GENERAL TERMS OF LIMITED WARRANTY
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
FRIEDRICH FRA18AZ Endeavor Line K-Series iM Air Conditioners
Product Information
- Product Name: EndeavorTM Line K-Series in Air Conditioners
- Model: FRA18AZ
- Brand: EndeavorTM
- Product Category: Air Conditioners
- SEER2: Varies based on model (ranging from 24 to 60)
- Refrigerant: Varies based on model
- Capacity BTU/HR: Varies based on model (ranging from 24,000 to 60,000)
- Major Series: A – 1st Design
- Voltage: J – 1ph, 208-230/60
- Controls: C – Communicating
Features and Benefits
- High energy efficiency with SEER2 rating
- A variety of models available with different capacities
- Inverter technology for precise temperature control
- Communicating controls for easy operation
Product Usage Instructions
- Make sure the air conditioner is placed in a location that allows for proper airflow and clearance. Refer to the Clearances section in the user manual for specific clearance requirements.
- Connect the air conditioner to the appropriate electrical power source. Check the Line Voltage Data section for the correct voltage specifications.
- Turn on the air conditioner using the controls provided. The specific control features may vary based on the model.
- Set the desired temperature and fan speed using the controls. The air conditioner will adjust its operation accordingly.
- Monitor the air conditioner’s performance and make any necessary adjustments to the temperature and fan settings for optimal comfort.
- Regularly clean and maintain the air conditioner as recommended in the user manual to ensure proper functioning and longevity.
*Proper sizing and installation of equipment is critical to achieve optimal performance. Split system air conditioners and heat pumps must be matched with appropriate coil components to meet Energy Star. Ask your Contractor for details or visit www.energystar.gov.
The Bluetooth® word mark and logos are registered trademarks owned by
Bluetooth SIG, Inc. and any use of such marks by Rheem® is under license.
Other trademarks and trade names are those of their respective owners.
Features and Benefits
- EcoNet® Enabled: Automatic system configuration and optimization
- PlusOne® Diagnostics & Bluetooth®1 Connectivity: With the Friedrich® Contractor & EcoNet® Apps, built-in technology makes advanced set-up, monitoring, troubleshooting, and repairing the product easier than ever before
- Brushless DC Condenser Motors (BLDC): Enhances reliability and allows for easier serviceability
- Swept Wing Fan Technology: Features quieter operation and improved unit acoustics
- PlusOne® Expanded Valve Space: 3 in. – 4 in. – 5 in. service valve space—provides a minimum working area of 27 square inches for easier access
- PlusOne® Triple Service Access: 15 in. wide, industry leading corner service access, two fasteners, removable corner and individual louver panels – makes repairs easier and faster
1 The Bluetooth® word mark and logos are registered trademarks owned by Bluetooth SIG, Inc., and any use of such marks by Rheem® is under license. Other trademarks and trade names are those of their respective owners.
Air Conditioners
[ ] Designates Metric Conversions
AVAILABLE MODELS | DESCRIPTION |
---|---|
FRA18AZ24AJVCA | Endeavor™ Line K-Series 2 ton EcoNet ® |
_Enabled_ Inverter Driven Variable Speed iM Air Conditioner
– 208/230/1/60
FRA18AZ36AJVCA| Endeavor™ Line K-Series 3 ton EcoNet ®
_Enabled_ Inverter Driven Variable Speed iM Air Conditioner
– 208/230/1/60
FRA18AZ48AJVCA| Endeavor™ Line K-Series 4 ton EcoNet ®
_Enabled_ Inverter Driven Variable Speed iM Air Conditioner
– 208/230/1/60
FRA18AZ60AJVCA| Endeavor™ Line K-Series 5 ton EcoNet ®
_Enabled_ Inverter Driven Variable Speed iM Air Conditioner
– 208/230/1/60
STANDARD EQUIPMENT
R-410A Refrigerant
EcoNet® Enabled
Variable Speed Compressor
Compressor Sound Blanket
Variable speed outdoor fan motor
Swept wing fan blade
Field Installed Filter Drier
Front Seating Service Valves
Internal Pressure Relief Valve
Internal Thermal Overload
Low Ambient capability
3-4-5 Expanded Valve Space
Composite Basepan
1″ Screw Control Box Access
15″ Access to Internal Components
Quick release louver panel design
No fasteners to remove along bottom
Optimized Venturi Airflow
Single row condenser coil 1
Powder coated paint
Rust resistant screws
QR code
External gauge ports
Service trays
¹ 5 Ton model includes 2 row condenser coil
General Data
MODEL NO.| FRA18AZ24AJVCA| FRA18AZ36AJVCA|
FRA18AZ48AJVCA| FRA18AZ60AJVCA
Nominal Tonnage| 2.0| 3.0| 4.0| 5.0
Valve Connections|
Liquid Line O.D. – in.| 3/8| 3/8| 3/8| 3/8
Suction Line O.D. – in.| 3/4| 3/4| 7/8| 7/8
Refrigerant (R410A) furnished oz.¹| 210| 212| 222| 252
Compressor Type| Scroll
Outdoor Coil|
Net face area – Outer Coil| 22.2| 22.3| 32.5| 32.5
Net face area – Inner Coil| —| —| —| 32.5
Tube diameter – in.| 0.375| 0.375| 0.375| 0.375
Number of rows| 1| 1| 1| 2
Fins per inch| 20| 20| 22| 20
Outdoor Fan|
Diameter – in.| 24| 24| 26| 26
Number of blades| 3| 3| 3| 3
Motor hp| 1/5| 1/3| 1/2| 1/2
CFM| 3330| 4315| 6240| 6175
RPM| 772| 825| 935| 900
watts| 83| 114| 278| 278
Shipping weight – lbs.| 226| 244| 263| 316
Operating weight – lbs.| 214| 236| 255| 307
Electrical Data
Line Voltage Data (Volts-Phase-Hz)| 208/230-1-60|
208/230-1-60| 208/230-1-60| 208/230-1-60
Maximum overcurrent protection (amps)²| 35| 45| 70| 80
Minimum circuit ampacity³| 21| 29| 46| 48
Compressor|
Rated load amps| 15| 20.1| 32| 34.1
Locked rotor amps| 35| 35| 50| 50
¹ Refrigerant charge sufficient for 15 ft. length of refrigerant lines. For
longer line set requirements see the installation instructions for information
about set length and additional refrigerant charge required.
²HACR type circuit breaker of fuse.
³Refer to National Electrical Code manual to determine wire, fuse and
disconnect size requirements.
Accessories
MODEL NO.| FRA18AZ24AJVCA| FRA18AZ36AJVCA|
FRA18AZ48AJVCA| FRA18AZ60AJVCA
---|---|---|---|---
EcoNet® Smart Thermostat| CETST800SYS| CETST800SYS| CETST800SYS| CETST800SYS
Compressor Sound Cover| STD| STD| STD| STD
Supply / Return Sensor| RXHT-A02| RXHT-A02| RXHT-A02| RXHT-A02
Weighted Sound Power Level
MODEL
| SOUND POWER LEVEL [DB(A)] LOW SPEED/ HIGH SPEED| FULL
OCTAVE LINEAR SOUND POWER LEVEL DB – CENTER
FREQUENCY – HZ| SOUND POWER LEVEL [DB(A)] WITH SOUND
BLANKET
---|---|---|---
125| 250| 500| 1000| 2000| 4000| 8000
FRA18AZ24AJVCA| 58.9| 29| 36.5| 42| 45.7| 42.3| 43.2| 33| ****
Sound Blankets – Standard
68| 47.1| 47.7| 58.8| 57.1| 55.0| 52.7| 45.6
FRA18AZ36AJVCA| 57| 29.2| 36.7| 44.9| 45.4| 42.2| 39.4| 32.2
72| 42.9| 52.8| 62.7| 63.6| 58.7| 54.1| 52.4
FRA18AZ48AJVCA| 54| 30.6| 39| 42.2| 42.5| 36.5| 35.2| 35
72| 48.2| 55.3| 64.6| 61.7| 56.2| 51.7| 46.2
FRA18AZ60AJVCA| 70| 46.6| 50.5| 62.7| 52.9| 49.4| 46| 41.4
76| 50.7| 62.7| 67.7| 65.4| 64.2| 59.2| 54.9
NOTE : Tested in accordance with AHRI Standard 270-08 (not listed in AHRI)
Unit Dimensions
MODEL NO.
| OPERATING| SHIPPING
---|---|---
H (Height)| L (Length)| W (Width)| H
(Height)| L (Length)| W (Width)
INCHES| mm| INCHES| mm| INCHES| mm| INCHES|
mm| INCHES| mm| INCHES| mm
FRA18AZ24AJVCA| 39| 990| 33.75| 857| 33.75| 857| 41.56| 1055| 37.64| 956|
37.56| 954
FRA18AZ36AJVCA| 39| 990| 33.75| 857| 33.75| 857| 41.56| 1055| 37.64| 956|
37.56| 954
FRA18AZ48AJVCA| 51| 1295| 35.75| 908| 35.75| 908| 53.56| 1360| 39.37| 999|
39.64| 1006
FRA18AZ60AJVCA| 51| 1295| 35.75| 908| 35.75| 908| 53.56| 1360| 39.37| 999|
39.64| 1006
[ ] Designates Metric Conversions
CLEARANCES
NOTE : NUMBERS IN () = mm
IMPORTANT : When installing multiple units in an alcove, roof well or
partially enclosed area, ensure there is adequate ventilation to prevent re-
circulation of the discharge air.
Control Wiring
Application Guidelines
- Intended for outdoor installation with free air inlet and outlet. The outdoor fan external static pressure available is less than 0.01 in. wc.
- The minimum outdoor operation air temperature for a cooling mode without a low-ambient operation accessory is 55°F (12.8°C).
- Maximum outdoor operating air temperature is 125°F (51.7°C).
- For reliable operation, the unit should be level in all horizontal planes.
- Use only copper wire for electric connections at the unit. Aluminum and clad aluminum are not acceptable for the type of connector provided.
- Do not apply capillary tube indoor coils to these units.
- Factory-supplied filter drier must be installed.
Refrigerant Line Size Information
18 SEER2 VARIABLE SPEED AIR CONDITIONERS
UNIT SIZE
| ****
ALLOWABLE LIQUID LINE SIZE
| ****
ALLOWABLE VAPOR LINE SIZE
| OUTDOOR UNIT ABOVE OR BELOW INDOOR UNIT EQUIVALENT LENGTH (FEET)
< 25| 26- 50| 51- 75| 76- 100| 101-
125| 126- 150
MAXIMUM VERTICAL SEPARATION/CAPACITY MULTIPLIER
2 Ton* SEE NOTE 3
| 1/4″| 5/8″| 25/1.00| 50/0.99| 32/0.98| 40/0.97| NR| NR
5/16″| 5/8″| 25/1.00| 50/0.99| 50/0.98| 50/0.97| 50/0.96| 50/0.95
3/8″| 5/8″| 25/1.00| 50/0.99| 50/0.98| 50/0.97| 50/0.96| 50/0.95
1/4″| 3/4″| 25/1.00| 50/1.00| 32/0.99| 40/0.99| NR| NR
5/16″| 3/4″| 25/1.00| 50/1.00| 50/0.99| 50/0.99| 50/0.99| 50/0.98
3/8″| 3/4″**| 25/1.00| 50/1.00| 50/0.99| 50/0.99| 50/0.99| 50/0.98
3 Ton
| 5/16″| 5/8″| 25/0.99| 50/0.97| 50/0.95| 50/0.93| 37/0.91| NR
3/8″| 5/8″| 25/0.99| 50/0.97| 50/0.95| 50/0.93| 50/0.91| NR
5/16″| 3/4″| 25/1.00| 50/0.99| 50/0.99| 50/0.98| 37/0.97| 22/0.96
3/8″| 3/4″| 25/1.00| 50/0.99| 50/0.99| 50/0.98| 50/0.97| 50/0.96
1/2″| 3/4″| 25/1.00| 50/0.99| 50/0.99| 50/0.98| 50/0.97| 50/0.96
4 Ton
| 3/8″| 3/4″| 25/0.99| 50/0.98| 50/0.97| 50/0.96| 50/0.94| 50/0.93
1/2″| 3/4″| 25/0.99| 50/0.98| 50/0.97| 50/0.96| 50/0.94| 50/0.93
3/8″| 7/8″| 25/1.00| 50/0.99| 50/0.99| 50/0.98| 50/0.98| 50/0.97
1/2″| 7/8″| 25/1.00| 50/0.99| 50/0.99| 50/0.98| 50/0.98| 50/0.97
5 Ton
| 3/8″| 3/4″| 25/0.99| 50/0.97| 50/0.95| 50/0.93| 50/0.91| NR
1/2″| 3/4″| 25/0.99| 50/0.97| 50/0.95| 50/0.93| 50/0.91| NR
3/8″| 7/8″| 25/1.00| 50/0.99| 50/0.98| 50/0.98| 50/0.97| 38/0.96
1/2″| 7/8″| 25/1.00| 50/0.99| 50/0.98| 50/0.98| 50/0.97| 50/0.96
NOTES:
- Do not exceed 150 ft linear line length.
- *Do not exceed 50 ft vertical separation between indoor and outdoor units.
- **3/4” suction line should only be used for 2 ton systems if the outdoor unit is below or at the same level as the indoor unit to ensure proper oil return.
- Always use the smallest liquid line allowable to minimize refrigerant charge.
- Applications shaded in light gray indicate capacity multipliers between 0.90 and 0.96 which are not recommended but are allowed.
- Applications shaded in dark gray are not recommended due to excessive liquid or suction pressure drop.
[ ] Designates Metric Conversions 18 SEER2 VARIABLE SPEED AIR CONDITIONERS
UNIT SIZE
| ALLOWABLE LIQUID LINE
SIZE
| ALLOWABLE VAPOR LINE
SIZE
| OUTDOOR UNIT ABOVE OR BELOW INDOOR UNIT EQUIVALENT LENGTH (METERS)
< **8| 8- 15| 16- 23| 24- 30| 31-
38| 39- 46
MAXIMUM VERTICAL SEPARATION/CAPACITY MULTIPLIER**
2 Ton* SEE NOTE 3
| 6.35 [1/4]| 15.88 [5/8]| 8/1.00| 15/0.99| 10/0.98| 10/0.97| NR|
NR
7.94 [5/16]| 15.88 [5/8]| 8/1.00| 15/0.99| 15/0.98| 15/0.97| 15/0.96| 15/0.95
9.53 [3/8]| 15.88 [5/8]| 8/1.00| 15/0.99| 15/0.98| 15/0.97| 15/0.96| 15/0.95
6.35 [1/4]| 19.05 [3/4]| 8/1.00| 15/0.99| 10/0.99| 12/0.99| NR| NR
7.94 [5/16]| 19.05 [3/4]| 8/1.00| 15/0.99| 15/0.99| 15/0.99| 15/0.99|
15/0.98
9.53 [3/8]| 19.05 [3/4]**| 8/1.00| 15/0.99| 15/0.99| 15/0.99| 15/0.99| 15/0.98
3 Ton
| 7.94 [5/16]| 15.88 [5/8]| 8/0.99| 15/0.97| 15/0.95| 15/0.93| 11/0.91|
NR
9.53 [3/8]| 15.88 [5/8]| 8/0.99| 15/0.97| 15/0.95| 15/0.93| 15/0.91| NR
7.94 [5/16]| 19.05 [3/4]| 8/1.00| 15/0.99| 15/0.99| 15/0.98| 11/0.97| 7/0.96
9.53 [3/8]| 19.05 [3/4]| 8/1.00| 15/0.99| 15/0.99| 15/0.98| 15/0.97| 15/0.96
12.70 [1/2]| 19.05 [3/4]| 8/1.00| 15/0.99| 15/0.99| 15/0.98| 15/0.97| 15/0.96
4 Ton
| 9.53 [3/8]| 19.05 [3/4]| 8/0.99| 15/0.98| 15/0.97| 15/0.96| 15/0.94| 15/0.93
12.70 [1/2]| 19.05 [3/4]| 8/0.99| 15/0.98| 15/0.97| 15/0.96| 15/0.94| 15/0.93
9.53 [3/8]| 22.23 [7/8]| 8/1.00| 15/0.99| 15/0.99| 15/0.98| 15/0.98| 15/0.97
12.70 [1/2]| 22.23 [7/8]| 8/1.00| 15/0.99| 15/0.99| 15/0.98| 15/0.98| 15/0.97
5 Ton
| 9.53 [3/8]| 19.05 [3/4]| 8/0.99| 15/0.97| 15/0.95| 15/0.93| 15/0.91| NR
12.70 [1/2]| 19.05 [3/4]| 8/0.99| 15/0.97| 15/0.95| 15/0.93| 15/0.91| NR
9.53 [3/8]| 22.23 [7/8]| 8/1.00| 15/0.99| 15/0.98| 15/0.98| 15/0.97| 12/0.96
12.70 [1/2]| 22.23 [7/8]| 8/1.00| 15/0.99| 15/0.98| 15/0.98| 15/0.97| 15/0.97
NOTES:
- Do not exceed 46 meters of linear line length.
- *Do not exceed 15 meters of vertical separation between indoor and outdoor units.
- **19.05mm [3/4 in.] vapor line should only be used for 2-ton systems if the outdoor unit is below or at the same level as the indoor unit to assure proper oil return.
- Always use the smallest liquid line allowable to minimize refrigerant charge.
- Applications shaded in light gray indicate capacity multipliers between 0.90 and 0.96 which are not recommended but are allowed
- Applications shaded in dark gray are not recommended due to excessive liquid or suction pressure drop.
Performance Data @ AHRI Standard Conditions – Cooling
DESIGNATED TESTED COMBINATION (DTC)
OUTDOOR UNIT| INDOOR COIL| TOTAL CAPACITY BTU/H
[KW]| NET SENSIBLE BTU/H [KW]| NET LATENT BTU/H [KW]|
SEER2| EER2| INDOOR CFM [L/S]
FRA18AZ24AJVC| RHMVZ2421MEACN| 22,400 [6.6]| 17,200 [5.0]| 5,200 [1.5]| 18.0|
10.5| 825 [389.4]
FRA18AZ36AJVC| RHMVZ6021SEACA| 34,600 [10.1]| 25,800 [7.6]| 8,800 [2.6]| 18.0|
10.5| 1,225 [578.1]
FRA18AZ48AJVC| RHMVZ6021SEACA| 45,000 [13.2]| 32,600 [9.6]| 12,400 [3.6]|
18.0| 10.5| 1,575 [743.3]
FRA18AZ60AJVC| RHMVZ6024SEACN| 55,000 [16.1]| 40,200 [11.8]| 14,800 [4.3]|
18.0| 10.5| 1,650 [778.7]
NOTE : This data includes DTC (Designated Test Combination) ratings and is for reference purposes only. A full listing of official ratings and system match-ups, along with downloadable certificates, can be accessed from the AHRI website: www.ahridirectory.org.
[ ] Designates Metric Conversions
Integrated Controls
EcoNet® is smart, technology that allows Heating and Cooling, products to communicate with each other on one integrated network.
THE ECONET® SMART THERMOSTAT
- BUILT-IN WIFI
- 4.3″ LCD TOUCH SCREEN
- LOCAL WEATHER – Current conditions plus 6-day forecast
- 5 OPERATING MODES – Heat, Cool, Auto, Emergency Heat and Fan Only
- 7-DAY PROGRAMMABLE SCHEDULE – Offers comfort without thought
- ONE-TOUCH AWAY – Quickly switch to your energy-saving away preferences
- VACATION SCHEDULING – Allows you to save while you’re away and come home to comfort
- STANDBY SCREEN – Displays indoor temperature and current weather
OPERATIONAL FEATURES
- AUTOMATIC CHANGEOVER – Transitions between heating and cooling automatically to keep the house comfortable
- INTEGRATED WATER CONTROL – Enables easy water heater management
- SMOOTH ARRIVAL – Prompts the system to start ahead of schedule to ensure the home is at the desired temperature at the scheduled time
- HUMIDITY CONTROL – Supports humidifier accessories or over-cool-based dehumidification
- DETAILED OPERATING STATUS – View pertinent equipment status information and run times
- CONTINUOUS FAN – Offers 5 speeds (Low, Medium Low, Medium, Medium High, High)
- SHORT-CYCLE PROTECTION – Avoids damage to equipment from short-run cycles
MONITORING & REMOTE CONTROL FEATURES
- ACTIVE MONITORING – Alerts to problems that need immediate attention
- REMOTE CONTROL – Allows adjusting of comfort and settings from anywhere using a mobile device
- SERVICE ALERTS – Sends routine maintenance reminders
- AIR FILTER MONITORING – Detects when it’s time to replace the air filter
- ALARM HISTORY – Displays time-stamped alarm codes with clear descriptions
GENERAL TERMS OF LIMITED WARRANTY
Friedrich® will furnish a replacement for any part of this product that fails
in normal use and service within the applicable period stated, in accordance
with the terms of the limited warranty.
*For complete details of the Limited and Conditional Warranties, including applicable terms and conditions, contact your local contractor or the Manufacturer for a copy of the product warranty certifi cate.
Conditional Unit Replacement
- (Registration Required) ………………………………Ten (10) Years
- Parts ………………………………………………………..Ten (10) Years
Before proceeding with installation, refer to installation instructions
packaged with each model, as well as complying with all Federal, State,
Provincial, and Local codes, regulations, and practices.
© 2023 Rheem Manufacturing Company. Friedrich trademarks are owned by Rheem
Manufacturing Company.
In keeping with its policy of continuous progress and product improvement,
Friedrich reserves the right to make changes without notice.
Friedrich • 5600 Old Greenwood Road
Fort Smith, Arkansas 72908 • www.friedrich.com
Friedrich • 125 Edgeware Road, Unit 1 Brampton, Ontario • L6Y 0P5