FRIEDRICH SS10M10 High Efficiency Air Conditioner Instruction Manual

June 17, 2024
FRIEDRICH

FRIEDRICH-logo

FRIEDRICH SS10M10 High Efficiency Air Conditioner

FRIEDRICH-SS10M10-High-Efficiency-Air-Conditioner-
image

Product Information

Specifications

  • Model Number: YS10M10A
  • Serial Number: LICY00008
  • Volts: 115
  • Frequency: 60 Hz / 1 PH
  • Minimum Volts: 108
  • Cooling Capacity: 6500 BTH/HR
  • EER (Energy Efficiency Ratio): 12.0
  • Amperage (Cooling): 8.0 Amps
  • Heating Capacity: 6500 BTH/HR
  • EER (Heating): 10.4
  • Amperage (Heating): 7.0 Amps
  • Refrigerant: R410A, 30.1 oz
  • High-Side Pressure: 600 PSIG
  • Low-Side Pressure: 300 PSIG
  • Fuse Type: 15A Time Delay Fuse

Product Usage Instructions

Installation

  1. Choose a suitable location for the air conditioner unit near a power outlet.
  2. Ensure proper clearance around the unit for efficient airflow.
  3. Install the unit according to the instructions provided in the installation manual.

Operation

  1. Make sure the air conditioner is connected to a power source.
  2. Turn on the power and select the desired operating mode (AUTO, AUTO CONTINUOUS, AUTO SYSTEM, FAN MODE, SCHEDULE).
  3. Adjust the fan speed to your preference (FAN SPEED).

Maintenance

  1. Regularly clean or replace the air filters according to the maintenance schedule provided in the user manual.
  2. Keep the exterior of the unit clean by wiping it with a damp cloth.
  3. Inspect the unit for any visible damage or loose connections.
    If any issues are found, contact a certified technician for repairs.

FAQs

Q: What should I do if the air conditioner is not cooling properly?

A: Check if the air filters are clean and not obstructed. Also, ensure that the temperature settings are appropriate for cooling. If the issue persists, contact a certified technician for further assistance.

Q: How often should I clean or replace the air filters?

A: It is recommended to clean or replace the air filters every 1-2 months, depending on usage and environmental conditions.

Q: Can I use this air conditioner in a room with higher voltage than specified?

A: No, it is important to use the air conditioner with the specified voltage to ensure safe and proper operation. Using higher voltage can damage the unit and void the warranty.

Installation and Operation Manual

Room Air Conditioners

Standard Chassis Models
115-Volt: SS08M10, SS10M10, SS12M10, SS14M10 208-230-Volt: SS12M30, SS15M30, SM18M30, SM21M30
SL25M30, SL28M30, SL36M30
115-Volt: YS10M10 208-230-Volt: ES12M33, ES15M33, YS12M33, EM18M34,
YM18M34, EL25M35, EL36M35, YL24M35

920-198-00 (11-09)
wwww.sylvane.com 1 800-934-9194
q

920-198-00
Congratulations!
Thank you for your decision to purchase the Friedrich High Efficiency Air Conditioner. Your new Friedrich has been carefully engineered and manufactured to give you many years of dependable, efficient operation, maintaining a comfortable temperature and humidity level. Many extra features have been built into your unit to assure quiet operation, the greatest circulation of cool, dry air, and the most economic operation.
THANK YOU, on behalf of our entire company, for making such a wise purchase.

AIR CONDITIONING CO. SAN ANTONIO, TEXAS ASSEMBLED IN MEXICO

MODEL NUMBER YS10M10A SERIAL NUMBER LICY00008

VOLTS 115 60 HZ / 1 PH VOLTS MIN 108

COOLING BTH/HR 6500 EER 12.0 AMPS 8.0

HEATING BTH/HR 6500 EER 10.4 AMPS 7.0

REFRIGERANT 30.1 OZ R410A

XXXXXXXXX 600 PSIG HS 300 PSIG LS

XXXXXXXXXX XXXXXXXXX XXXXXXXXXX XXXXXXXXXX

FUSE PROTECTED CIRCUITS USE 15A TIME DELAY FUSE

X UL XX XXXXX
XXXXXXXXXX

AIR CONDITIONING CO. SAN ANTONIO, TEXAS ASSEMBLED IN MEXICO

MODEL NUMBER YS10M10A SERIAL NUMBER LICY00008

Register your air conditioner
Model information can be found on the name plate behind the front cover. Please complete and mail the owner registration card furnished with this product, or register online at www.friedrich.com (USA only). For your future convenience, record the model information here.
MODEL NUMBER
SERIAL NUMBER
PURCHASE DATE

2
wwww.sylvane.com 1 800-934-9194

Safety Precautions

920-198-00

Your safety and the safety of others are very important.
We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety messages.
This is a safety Alert symbol. This symbol alerts you to potential hazards that can kill or hurt you and others. All safety messages will follow the safety alert symbol with the word “WARNING” or “CAUTION”. These words mean:

WARNING

Indicates a hazard which, if not avoided, can result in severe personal injury or death and damage to product or other property.

CAUTION

Indicates a hazard which, if not avoided, can result in personal injury and damage to product or other property.

All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what will happen if the instructions are not followed.

NOTICE

Indicates property damage can occur if instructions are not followed.

WARNING
Refrigeration system under high pressure
Do not puncture, heat, expose to flame or incinerate. Only certified refrigeration technicians should service this equipment. R410A systems operate at higher pressures than R22 equipment. Appropriate safe service and handling practices must be used.
Only use gauge sets designed for use with R410A. Do not use standard R22 gauge sets.

4
wwww.sylvane.com 1 800-934-9194
q

920-198-00

Unpacking Instructions

STEP 1. Cut all 4 packing straps. STEP 2. Remove wooden shipping bar dividers. STEP 3. Remove top foam pads. STEP 4. Slowly remove outer box, careful not to loosen decorative front.

STEP 5. STEP 6. STEP 7.

Slide the foam front support forward Carefully lift decorative front box from foam front support Remove decorative front and set safely aside

67(3

67(3

67(3

67(3

67(3

67(3

67(3

‘5$:1
HKHUQDQGH] &+(&.(‘
4$
0)*
$33529(‘

7,
6

5
wwww.sylvane.com 1 800-934-9194
q

920-198-00
WARNING:

Before Operating Your Unit

WARNING

NOTICE

Electrical Shock Hazard
Make sure your electrical receptacle has the same configuration as your air conditioner’s plug. If different, consult a Licensed Electrician.
Do not use plug adapters. Do not use an extension cord. Do not remove ground prong.
Always plug into a grounded 3 prong oulet. Failure to follow these instructions can result in death, fire, or electrical shock.
Make sure the wiring is adequate for your unit.
If you have fuses, they should be of the time delay type. Before you install or relocate this unit, be sure that the amperage rating of the circuit breaker or time delay fuse does not exceed the amp rating listed in Table 1.
DO NOT use an extension cord.
The cord provided will carry the proper amount of electrical power to the unit; an extension cord may not.
Make sure that the receptacle is compatible with the air conditioner cord plug provided.
Proper grounding must be maintained at all times. Two prong receptacles must be replaced with a grounded receptacle by a certified electrician. The grounded receptacle should meet all national and local codes and ordinances. You must use the three prong plug furnished with the air conditioner. Under no circumstances should you remove the ground prong from the plug.
Test the power cord
All Friedrich room air conditioners are shipped from the factory with a Leakage Current Detection Interrupter (LCDI) equipped power cord. The LCDI device on the end of the cord meets the UL and NEC requirements for cord connected air conditioners.
To test your power supply cord:
1. Plug power supply cord into a grounded 3 prong outlet.
2. Press RESET (See Figure 1).
3. Press TEST, listen for click; the RESET button trips and pops out.
4. Press and release RESET (Listen for click; RESET button latches and remains in). The power cord is ready for use.

Do not use the LCDI device as an ON/OFF switch.
Failure to adhere to this precaution may cause premature equipment malfunction.

Once plugged in, the unit will operate normally without the need to reset the LCDI device. If the LCDI device fails to trip when tested or if the power supply cord is damaged, it must be replaced with a new power supply cord from the manufacturer. Contact our Technical Assistance Line at 800-541-6645. To expedite service, please have your model number available.

Table 1.
MODEL
SS08M10, SS10M10, SS12M10, SS14M10, YS10M10 SS12M30, SS15M30, SM18M30, SM21M30 SL25M30, SL28M30, ES12M33, ES15M33, YS12M33 SL36M30, EM18M34, EL25M35, EL36M35, YM18M34, YL24M35

CIRCUIT RATING OR TIME DELAY
FUSE

REQUIRED WALL
RECEPTACLE

AMP

VOLT

NEMA NO.

15

125 5-15R

15

250 6-15R

20

250 6-20R

30

250 6-30R

Figure 1
RESET TEST
WARNING
TEST BEFORE EACH USE 1. PRESS RESET BUTTON 2. PLUG LCDI INTO POWER
RECEPTACLE 3. PRESS TEST BUTTON,
RESET BUTTON SHOULD POP UP
4. PRESS TEST BUTTON, FOR USE
DO NOT USE IF ABOVE TEST FAILS WHEN GREEN LIGHT IS ON IT IS WORKING PROPERLY

TEST
RESET
WARNING
TEST BEFORE EACH USE 1. PRESS RESET BUTTON 2. PLUG LCDI INTO POWER
RECEPTACLE 3. PRESS TEST BUTTON,
RESET BUTTON SHOULD POP UP 4. PRESS TEST BUTTON, FOR USE DO NOT USE IF ABOVE TEST FAILS WHEN GREEN LIGHT IS ON IT IS WORKING PROPERLY

15/20A LCDI Device

30A LCDI Device
FRR001

6
wwww.sylvane.com 1 800-934-9194
q

920-198-00

Standard Filter Cleaning / Installation Instructions

STEP 1. Swing the door open and remove the filter by grasping the filter grip and pushing the filter holder upward and outward.

STEP 2. Slide the filter grip out from the filter as shown in Figure 4. NOTE: Make sure the front frame with the mesh filter is facing you.

Figure 2

Figure 4

Figure 3

FILTER

FRR071
FILTER GRIP
HANDLE
FRR052

FILTER GRIP

STEP 3.

FRR047
Swing the front frame open. Clean the front frame by washing the dirt from the filter. Use a mild soap solution if necessary. Allow filter to dry.

Figure 5

A

TOP TAB

FRONT FRAME WITH STANDARD MESH FILTER

FRR048

STEP 4. Install the filter grip back into the filter by sliding it into the filter.

NOTE:

The filter handle slides into the frame in only one direction. If the tab in the frame stops the handle from sliding in, slide the handle from the other direction. Do not force the handle into the frame.

STEP 5. Install the filter back into the unit. Follow the Instructions on the inside of the front door.

7
wwww.sylvane.com 1 800-934-9194
q

920-198-00

Premium Carbon Filter Installation Instructions

STEP 1. Remove the filter from the unit as per the instructions on the inside of the filter door.

STEP 2. Hold the filter at the top and slide the filter grip out as shown in Figure 4.

STEP 3.

If you already have a carbon filter installed remove the dirty filter by laying the filter down and swinging open the front frame as shown in Figure 6.

NOTE: Make sure the frame with the mesh is facing towards you.

STEP 4.

Place the new carbon filter on the top of the back filter frame. The carbon filter has been cut to the correct dimension and should fit within the frame as shown in figure 7

NOTE: The carbon filter is not a re-usable filter, and needs to be replaced every three months for optimum efficiency.

STEP 5.

Slide the filter handle back on to hold the frames together and slide the assembly into the unit as per the instructions on the door.

NOTE:

The filter handle slides into the frame in only one direction. If the tab in the frame stops the handle from sliding in, slide the handle from the other direction. Do not force the handle into the frame.

Figure 6

Figure 7

FRONT FRAME WITH MESH FILTER

FRR050

FRR051

8
wwww.sylvane.com 1 800-934-9194
q

920-198-00
THIS PAGE INTENTIONALLY LEFT BLANK
9
wwww.sylvane.com 1 800-934-9194
q

920-198-00

Control Panel Operation
Let’s check out how to control your air conditioner. On the control panel, just to the left of the POWER , is a liquid crystal display (LCD). All of the control panel function buttons and mode icons can be viewed in Figure 8.
Power On ­ Press the button to turn on the air conditioner. The power button will illuminate to indicate the power is on. The backlight on the power switch will automatically dim to 20% intensity after 15 seconds of inactivity. The remote control can also be used to turn power ON / OFF (See Remote Control).
Display ­ The display is a high efficiency LCD with a built-in white back light. The back light has an automatic two (2) step dim function. After 15 seconds of inactivity, the display dims to 20% intensity. After an additional 120 seconds, the display switches off. Touching buttons will automatically bring the display to full brightness.
There are four control push buttons on each side of the display.
SYSTEM Button ­ Allows the user to sequentially select, AUTO Cool , HEAT , and FAN ONLY operation. Press the SYSTEM button and
the display advances to the next mode. A new icon appears. At the same time, the mode displays for two (2) seconds, then returns the display to the temperature set point for modes other than FAN. Note that when the heating function is not available, the system will automatically skip the HEAT and AUTO modes.
FAN MODE Button ­ Selects between automatic AUTO or CONTINUOUS operation. In the AUTO mode, the fan only turns on and off when the compressor operates or the heat function is enabled.
In the FAN ONLY Mode, AUTO is not available. The display indicates . CONTINUOUS In the CONTINUOUS mode, fans speed is determined by your selection on the FAN button.
SPEED

FAN SPEED Button ­ Used to sequentially select between fan speeds.

Depending on your model, you can select between LOW, MED, HIGH,

and MAX and AUTO. Max setting not on SL or Kühl + models). When

the

FAN SPEED

button is

pressed,

the

fan

speed is temporarily displayed

in

the

display window, plus a fan speed icon (triangle) changes to indicate the

new speed level when auto is selected. Fan speed automatically varies

depending on the set temperature on the control panel and the actual

room temperature. Let me explain. Say for example you’re working in

your garage and you need to open the big door for several minutes. The

air conditioner will sense a wide difference between the set temperature

and the actual room temperature when this occurs the system fan speed

increases to MAX. The fan speed decreases (in step) as the temperature

difference decreases. When the set point temperature is reached the FAN

speed returns to the original setting.

SCHEDULE Button ­ The SCHEDULE button turns the schedule function on and off. The current day of the week is indicated as a dot underneath the day symbol. Pressing the SCHEDULE button a second time turns the schedule function off. The schedule function comes preprogrammed with recommended energy savings values (Addendum 1). The values may be changed through the schedule program function (See Programmable Thermostat).

UP and DOWN arrows ­ Pressing either (UP) or (DOWN) button changes the desired room temperature. The factory preset lower and upper limits are 60° F (16° C) and 99° F (37° C). These buttons are also used to navigate between function options when using the User Menu or Maintenance Mode.

BACK Button ­ This button is used after a menu item has been selected. It takes the user back to the previous menu level.

DISPLAY/ENTER Button ­ This button is used in conjunction with User Menu and Maintenance Mode operation to select items.

Alerts ­ The control system has five (5) customer alerts.

Figure 8
AUTO MODE

COOL MODE

HEAT MODE

FAN ONLY MODE

FRONT MAINTENANCE PANEL FILTER
REQUIRED LOCK MAINTENANCE WAIT

SYSTEM
FAN MODE
FAN SPEED
SCHEDULE

AUTO

CHECK ON EXIT FILTER OFF RESET

AUTO CONTINUOUS
AUTO

OUTDOOR TEMP ROOM TEMP % RH

HEAT ->SET POINT<- COOL
F
A M P M

C
MTWT F S S WAKE AWAY RETURN NIGHT

BACK
DISPLAY ENTER

POWER

BUTTONS SCHEDULE ON/OFF

SCHEDULE PERIODS

BUTTONS

10
wwww.sylvane.com 1 800-934-9194
q

FRR002

920-198-00

CHECK

FILTER

­

When

the

fi lter

needs

to

be

checked,

an

icon

CHECK FILTER

appears on screen. The word ” RESET ” appears next to the BACK button.

The

CHECK FILTER

alert

is

issued

when

the

fan

run

time

is

greater

than

500

hours.

This alert may be reset by the user (Refer to Special Functions, Filter Reset).

Maintenance Required ­ When maintenance is required, a service icon appears on screen. This icon will not be dismissed until maintenance
has been performed. If the service icon flashes, maintenance is required and must only be performed by qualified service personnel. When the icon is on standby the system has sensed an abnormal condition. For example: The air in/out louvres may be blocked. Once proper air flow is established the service icon goes away.

Wait ­ The WAIT icon illuminates when the compressor lockout is active. Whenever the compressor shuts off, system pressures must be allowed to equalize. At this time, an internal timer begins a count-down from up to 240 seconds. If a demand for heat or cool occurs during this count-down the WAIT icon displays letting you know that the compressor will not operate until the count-down has completed. This timer prevents damage to the unit if it tries to start too quickly after it stops running. Normally the WAIT icon is off. Once the timer has cleared, the air conditioner will heat or cool based on the temperature setting. Electric heat is not affected by this timer.

Protection Alert (Freeze) ­ If the room freeze protection is active, the display indicates this by showing Room Freeze Protection “FRZ”. Once the condition is satisfied, the “FRZ” display is removed. If the room temperature is less than 40° F (4° C), and the air conditioner is equipped with electric heat, the room freeze protection will activate. The air conditioner will run high fan and electric heat until the room temperature reaches 46° F (8° C). Pressing the BACK button delays the freeze protection function for five (5) minutes.

Low Battery ­ When the battery is low a warning display

will be

inserted before other messages such as “COOL”. If the Low Battery

alert is on, the battery in the control unit must be changed. Refer

to the changing the battery procedure. Once the battery is changed, the

alert message will go off. Refer to Troubleshooting Tips. Under normal

conditions the battery life should be greater than 7 years.

Special Functions

Panel Lock ­ The front panel push buttons can be locked to prevent

inadvertent operation. To lock the front panel, press and hold the SCHEDULE +

DISPLAY ENTER

buttons for three (3) seconds.

A double beep indicates your mode

change was successful and a icon appears on the display. To unlock

the display, press and hold the SCHEDULE + DISPLAY buttons for three (3) seconds. ENTER
The icon will no longer be visible.

Filter

Reset

­

If

the

CHECK FILTER

icon

displays,

the

timer

may

be

reset

by

pressing

and holding the BACK button for three (3) seconds. A beep indicates the

CHECK FILTER

system timer was reset and the

CHECK FILTER

icon and the word ” RESET ” will

no longer be visible.

User Menu Functions ­ The User Menu Functions allows you to change the following selections: Set TIME, 12/24 Hour Clock Format, BEEP ON / OFF, DIM ON / OFF, Emergency Heat (EMHT) ON / OFF, Auto BAND Adjust, F/ C Select, FRZ ON / OFF and Temp Offset.

To enter the User Menu, press and hold

DISPLAY ENTER

for 3 seconds, the TIME

selection appears. Use the (UP) or (DOWN) buttons to scroll

through the User Menu.

Press the

DISPLAY ENTER

button

to

enter

the

displayed

function. If left inactive for 15 seconds the User Menu display will no longer

be visible and it returns to normal operation mode display. To manually

exit the User Menu, press the BACK button.

SYSTEM
FAN MODE
FAN SPEED
SCHEDULE

EXIT

BACK

DISPLAY ENTER

The hour digits flash first. The user presses the or

to change the hours. To change AM-PM, the hours must be

advanced 12 hours. Press the

DISPLAY ENTER

key to change to the

minutes. To exit the selection process, user presses the BACK

key which will go to the time screen.

The minutes digits flash. The user presses the or

to change the minutes. Press the

DISPLAY ENTER

key to change the days.

To exit the selection process, the user presses the BACK key

which will go to the time screen.

The dot underneath the days of the week begins to blink to

indicate which day it is. If the user has not set the date before

the dot starts on Monday. If the user is making a correction to

previously set information the dot appears under whichever

day the unit thinks it is. The user can press or to move

the dot left or right (respectively) along the week. The user

presses

DISPLAY ENTER

to loop back to the hours setting. To exit the

selection process, the user presses the BACK key which will go

to the time screen.

Tuesday has been selected. The user presses

DISPLAY ENTER

to loop

back to the hours setting. To exit the selection process and

accept the changes, the user presses the BACK key which will go

to the time screen.

FRR062

Time Setting ­ When in the User Menu, on the Control Panel, use the

(UP) and

(DOWN) to select TIME.

Push

DISPLAY ENTER

,

the

hours

segment

flashes. Use the (UP) and (DOWN) to set the hour, then push

. DISPLAY
ENTER

The minutes segment and AM or PM flashes.

Use the

(UP) and

(DOWN) to set the minutes, then push

. DISPLAY
ENTER

NOTE:

If the AM or PM indicator is incorrect, push

DISPLAY ENTER

until the hours

segment flashes, use the (UP) or (DOWN) to advance

the hour segment 12 hours, then push

. DISPLAY
ENTER

The day of the week

displays. Use the (UP) or (DOWN) to select the current

day. Press the BACK key to go back to the TIME screen. Press

(UP) to go to the next menu 1224.

NOTE: Pressing the BACK button again will exit the user menu function mode. Or simply leave the control inactive for 15 seconds and the control will return back to normal operation.

11
wwww.sylvane.com 1 800-934-9194
q

SYSTEM
FAN MODE
FAN SPEED
SCHEDULE

EXIT

BACK

DISPLAY ENTER

920-198-00

SYSTEM
FAN MODE
FAN SPEED
SCHEDULE

EXIT

BACK

DISPLAY ENTER

User presses or to toggle the format between 12HR and 24HR display. To exit the selection process and accept the change, press the BACK key.

FRR063

Clock Type ­ You may select between a 12 hr and 24 hr clock. When

1224 is displayed press the

DISPLAY ENTER

key then press

(UP) or

(DOWN)

to toggle between 12 hr and 24 hr clock. To accept the change, press the

BACK key to return to the 1224 screen. Press the (UP) to go to the

next menu BEEP.

SYSTEM
FAN MODE
FAN SPEED
SCHEDULE

EXIT

BACK

DISPLAY ENTER

User presses or to toggle between Beep On and Beep Off. Press the BACK key to accept the change and exit the selection process.

FRR064

Audible Alerts ­ You can select to have the control beep when buttons

are pushed at the unit control or when a signal is received from the remote

control.

When BEEP is displayed press the

DISPLAY ENTER

key then press

(UP)

or (DOWN) to toggle between ON and OFF. To accept the change,

press the BACK key to return to the BEEP screen. Press the (UP) to go

to the next menu EMHT on Kühl+ models or F C for Kühl models.

SYSTEM
FAN MODE
FAN SPEED
SCHEDULE

EXIT

BACK

DISPLAY ENTER

User presses or to toggle between Emergency Heat On and Emergency Heat Off. Press the BACK key to accept the change and exit the selection process.

FRR065

Emergency Heat ­ The Kühl+ heat pump models (YS, YM, YL) have

a special feature that is designed to bring the temperature of the space

up quickly when the unit is first cycled into the heating mode. With the

emergency heat feature enabled the electric heat will be used to bring the

temperature up to the setpoint initially, then utilize the energy saving heat

pump mode to maintain the temperature. If the emergency heat feature

is not selected the unit may take more time initially to reach the setpoint

at the initial selection of heat.

When EMHT is displayed press the

DISPLAY ENTER

key then press (UP) or (DOWN) to toggle between ON and OFF.

To accept the change, press the BACK key to return to the EMHT screen.

Press the (UP) to go to the next menu BAND.

12

The menu allows the user to adjust the minimum spread between the Auto Cool set point and the Auto Heat set point. Press the or key to adjust. The adjust range is 3 to 10.

FRR066

Auto Changeover `Dead Band’ ­ For Kühl+ models with the auto

changeover feature you can select the temperature band between heating

and cooling. From the factory the band is set at 3° F (-16° C). The band is

adjustable from 3° F (-16° C) to 10° F (-12° C). When BAND is displayed

press the

DISPLAY ENTER

key then press

(UP) or

(DOWN) to toggle between

3 and 10. To accept the change, press the BACK key to return to the BAND

SYSTEM
FAN MODE
FAN SPEED
SCHEDULE

EXIT

BACK

DISPLAY ENTER

User presses or to select between AUTO, DM 20, OFF. Press the BACK key to accept the change and exit the selection process.
The Dim Auto automatically dims the display and then turns it off after a period of time. The Dim 20 setting behavior is similar to AUTO, but prevents the display from turning off. Minimum brightness is 20%. The Dim Off setting forces the display to run at full brightness.

FRR067

SYSTEM
FAN MODE
FAN SPEED
SCHEDULE

EXIT

BACK

DISPLAY ENTER

User presses or at the same time to toggle between Fahrenheit or Celsius as their temperature unit of choice. Press the BACK key to accept the change and exit the selection process.
FRR068

screen. Press the (UP) to go to the next menu F C.

Fahrenheit / Celsius Selection ­ You may select between displaying

temperature in F or C.

When F C is displayed press the

DISPLAY ENTER

key then

press (UP) or (DOWN) to toggle between F and C. To accept the

change, press the BACK key to return to the F C screen. Press the

wwww.sylvane.com 1 800-934-9194
q

SYSTEM
FAN MODE
FAN SPEED
SCHEDULE

EXIT

BACK

DISPLAY ENTER

920-198-00

User presses or to select between Freeze Protection On & Freeze Protection Off. Press the BACK key to accept the change and exit the selection process.

FRR069

(UP) to go to the next menu FRZ.

Freeze Protection ­ The Kühl+ models have a special feature that is

designed to keep the interior space above freezing by energizing the

electric heater anytime the indoor room temperature falls to 40° F (4° C).

With the freeze protection feature turned on, when the unit senses the

indoor temperature fall to 40° F (4° C) the unit will run the heater and high

fan until the space reaches 46° F (8° C) When FRZ is displayed press

the

DISPLAY ENTER

key then press

(UP) or

(DOWN) to toggle between ON

SYSTEM
FAN MODE
FAN SPEED
SCHEDULE

EXIT

BACK

DISPLAY ENTER

User presses or to increment/decrement the temperature offset (TO) for the room temperature sensor. (Maximum offset = +/- 8 degrees F). Press the BACK key to accept the change and exit the selection process
FRR070

and OFF. To accept the change, press the BACK key to return to the FRZ screen. Press the (UP) to go to the next menu TO.

Temperature Offset ­ In some cases the built in thermostat on the unit

may not display the temperature as it is felt in the room. This can be caused

by many things including the size of the unit, the heat load on the room or

other factors. Friedrich allows you to select the appropriate temperature

offset to make the temperature readout as accurate as possible for your

application. In many cases the factory 0° F (-18° C) offset will provide

an accurate temperature readout. To change the offset follow these

instructions.

When TO is displayed press the

key then press DISPLAY
ENTER

(UP) or (DOWN) to toggle between 0° F (-18° C) and 8° F (-13° C).

In most instances an offset from 0° F (-18° C) to 2° F (-17° C) is all that is

necessary. To accept the change, press the BACK key to return to the TO

screen. Press the (UP) to go to the next menu TIME.

You may cycle through the menus using the (UP) or (DOWN) keys

13
wwww.sylvane.com 1 800-934-9194
q

920-198-00

to access any of the menus.

Add a Remote Thermostat

Remote Thermostat ­ An external thermostat may be added to the air conditioner to provide remote temperature sensing and control. The thermostat interface connector is located on the panel behind the front grille. To enable the remote thermostat operation, remove the jumper

  1. Changing modes on the remote thermostat will not illuminate the Control Panel LCD.
    Remote Thermostat Selection
    Friedrich recommends the use of either the RT4 or RT5. The RT4 is a digital display thermostat with single speed fan control. The RT5 features a digital display, two fan speed selection, battery backup and backlight.

Figure 9

THERMOSTAT CONNECTOR

FP F2 F1 D2 D1 C GH GL B Y W R

POWER CORD

THERMOSTAT WIRE ROUTING USE #18 AWG COLORED THERMOSTAT WIRE

TO REMOTE THERMOSTAT

Table 2

Interface Definitions

Terminal Code

Wire Connection Function

C

Common Ground Terminal

GH

Call for Heating

GL

Call for Compressor

B

24V Power from Electronic Control to Wall Thermostat

Y

Call for low fan

W

Call for high fan

R

Call for heat pump reversing valve

between terminals 11 & 12 on the terminal block. Connect the thermostat using Figure 9 and Table 2 as a guide.

If you connect an external thermostat, all Control Panel buttons will be disabled with the following exception:

  1. Maintenance commands (double button press & single button extended press).

The

DISPLAY ENTER

button for Freeze protection.

  1. First Button pushed, illuminate the LCD.

14

FRR004
Other thermostats may be used as long as they are configured correctly for the unit. For cooling models a single stage cooling thermostat with C, R, G, Y terminals must be used. For electric heat E’ models a single stage heating and cooling thermostat with C, R, G, Y, W terminals must be used. For heat pumpY’ models a single stage heating and cooling thermostat with C, R, G, Y, W, B terminals must be used.
CAUTION
It is the installer’s responsibility to ensure that all control wiring connections are made in accordance with the installation instructions.
Improper connection of the thermostat control wiring and/or tampering with the unit’s internal wiring can void the equipment warranty.
Failure to follow these instructions can result in personal injury and damage to product or other property.

wwww.sylvane.com 1 800-934-9194
q

920-198-00

Remote Control Operation

Remote Control ­ Refer to Figures 11 and 12 during operation description.
Getting Started ­ Install two (2) AAA batteries in the battery compartment located on the back of the unit.
Operation ­ The remote control should be within 25 feet of the air conditioner for operation (Refer to Figure 10 for effectiveness). Press the
button to turn the remote on. The remote will automatically power off after 15 seconds if the buttons are not being pressed. The remote must be on to control the unit.
POWER Button ­ Turns remote and unit on and off.
SYSTEM Button ­ Allows the user to sequentially select, AUTO Cool , HEAT , and FAN ONLY operation. When the button is pressed, the display indicates which mode has been selected via a display message. Note that when the heating function is not available, the system will automatically skip the HEAT and AUTO modes.
FAN MODE Button ­ Selects between automatic ( AUTO ) or CONTINUOUS operation. In the AUTO mode, the fan only turns on and off when the compressor operates or the heat function is enabled.
NOTE: AUTO is not available in the FAN ONLY Mode, the display indicates CONTINUOUS . In the CONTINUOUS mode, fan speed is determined by your selection on the FAN button.
SPEED
Figure 10

FAN SPEED Button ­ Used to sequentially select new fan speed, plus

AUTO

operation.

When

the

FAN SPEED

button

is

pressed,

the

fan

speed

is

temporarily displayed in the display window, plus a fan speed icon (triangle)

changes to indicate the new speed level. Fan speed automatically varies

depending on the set temperature on the control panel and the actual

room temperature. Let me explain. Say for example you’re working in

your garage and you need to open the big door for several minutes. Since

there is a big difference between your set temperature and the actual room

temperature the system fan speed increases to MAX. It remains at this

speed until the room temperature matches the set temperature.

SCHEDULE Button ­ The SCHEDULE button turns the schedule function on and off. Pressing the SCHEDULE button a second time turns the schedule function off. Only the schedule icon will be displayed.

UP and DOWN Arrows ­ Pressing either the (UP) or (DOWN) button changes the desired room temperature. The factory preset lower and upper limits are 60° F (16° C) and 99° F (37° C). These buttons are also used to navigate between function options when using the User Menu or Maintenance Mode.
Remote Effectiveness

Hand Held Remote ­ Has an operating range of up to 25 ft. The infrared remote control signal must have a clear path to transmit the command to the air conditioning unit. The remote signal has some ability to “bounce” off of walls and furniture similar to a television remote control. The diagram below shows the typical operating range of the control in a standard room with 8 ft high ceilings.

TOP VIEW

25ft

25ft

SIDE VIEW

7.5ft

45°

30°

60°

60° 45°
30°

8ft

25ft
25ft 25ft
25ft

4ft

60° 60°

6ft

8ft

45°

45°

30°

30°

16ft

25ft
25ft
FRR046

15
wwww.sylvane.com 1 800-934-9194
q

Figure 11

920-198-00

DISPLAY

SYSTEM
TEMPERATURE UP
SCHEDULE

FAN MODE POWER TEMPERATURE DOWN
FAN SPEED

Figure 12

AUTO ICON

SYSTEM MODE
FAN MODE
FAN SPEED

COOL ICON

HEAT ICON

FAN ONLY ICON

FRR005
°F / °C ICONs

SCHEDULE ICON

2 X 16 SEGMENT DISPLAY

16

wwww.sylvane.com 1 800-934-9194
q

FRR006

920-198-00

Airflow Selection and Adjustment

Air flow direction adjustment
The airflow path may be adjusted to distribute air independently from the left or right side of the discharge opening. Each of the banks of louvers can be directed left, right, up or down in order to achieve the most optimum airflow positioning.
To adjust airflow direction grab the lever in the center of the louver bank and move it in the direction that you would like the air to be directed. Please note that it is normal that airflow may be stronger out of one side of the louvers than the other.
TO BRING IN FRESH AIR ­ Move the lever to the Fresh Air position which allows outside air to enter the room. This is useful in fall and spring as a means of bringing in fresh outside air when using FAN ONLY . It can also be used in the summer with the compressor in the Cooling Mode if you wish.
Fresh air and exhaust control
Your air conditioner has the ability to bring fresh air into the room or exhaust stale air out of the room. The control slide is found on the upper part of the unit (See Figure 13).
TO EXHAUST INDOOR AIR ­ Move the lever to the Exhaust position. This will allow stale air to be expelled to the outside of the dwelling. This is especially handy in the spring or fall when indoor air tends to get stale, or after a social gathering involving smokers, or to remove cooking odors.
BEST PERFORMANCE ­ Move the lever to the Re-Circulate Position . This is the most efficient mode for cooling and heating.

Figure 13

FRR008

17
wwww.sylvane.com 1 800-934-9194
q

920-198-00

Installation Instructions

READ THIS FIRST! Electrical Requirements
WARNING
Electrical Shock Hazard
Make sure your electrical receptacle has the same configuration as your air conditioner’s plug. If different, consult a Licensed Electrician.
Do not use plug adapters. Do not use an extension cord. Do not remove ground prong.
Always plug into a grounded 3 prong oulet. Failure to follow these instructions can result in death, fire, or electrical shock.
IMPORTANT: Before you begin the actual installation of your air conditioner, check local electrical codes and the information below. Your air conditioner must be connected to a power source with the same alternating current (A.C.) voltage and amperage as marked on the name plate located on the chassis. Only A.C. can be used. Direct Current (D.C.) cannot be used.
CIRCUIT PROTECTION ­ Use on single outlet circuit only. An overloaded circuit will invariably cause malfunction or failure of an air conditioner, therefore, it is necessary that the electrical protection is adequate. Due to momentary high current demand when the air conditioner starts, use a “TIME DELAY” fuse or a HACR type circuit breaker. Consult your dealer or power company if in doubt.
Refer to the electrical name plate located on the air conditioner chassis (See page 2) to determine the correct fuse or circuit breaker amperage for your model (See Table 1 on Page 6 for electrical receptacle types).
The power cord has a plug with a grounding prong and a matching receptacle is required.

The following instructions are for standard chassis model groups distinguished by the first two letters of the model designations and cabinet sizes listed in Table 3.

Table 3

MODEL DESIGNATION CABINET SIZE (H x W x D)

SMALL CHASSIS – SS, 15 15/16″ x 25 15/16″ x 29″ (405 mm x

ES, YS

660 mm x 737 mm)

MEDIUM CHASSIS – SM, 17 15/16″ x 25 15/16″ x 29″ (455 mm x

EM, YM

660 mm x 737 mm)

LARGE CHASSIS – SL, 20 3/16″ x 28″ x 35 1/2″ (513 mm x 711

EL, YL

mm x 851 mm)

WARNING
MOVING PARTS HAZARDS

  • Do not operate unit out of sleeve or with front grille removed.
  • Do not place hands in blower or fan blade areas.
    Failure to do so can result in serious injury.

CAUTION
Excessive Weight Hazard Use two or more people when installing your air conditioner.
Failure to do so can result in back or other injury.

Recommended Tools

  1. Power Drill
  2. 5/32″ Drill Bit
  3. Gloves
  4. Carpenters Level

1

  1. 5/16″ Wrench
  2. 1/4″ Wrench
  3. 2 Phillips Screw Driver 2

    8. Putty Knife or (wood stir stick)

5/16

4
5/16
5

1/4
6

1/4

7

8

3

ITEMS NOT TO SCALE

18

wwww.sylvane.com 1 800-934-9194
q

920-198-00
INSTALLATION HARDWARE AND ACCESSORY DETAIL

ITEM 1 ITEM 4 ITEM 7

ITEM 2

ITEM 3

ITEM 5

ITEM 6

ITEM 8

ITEM 9

ITEM 10 ITEMS NOT TO SCALE

ITEM 11

ITEM 12

ITEM 13

ITEM 14

ITEM NO
1 2 3 4

DESCRIPTION
SHELL MOUNTING PARTS SUPPORT BRACKET SCREW, 10-24 x 1″ HEX HEAD 10-24 FLAT WELD NUT SCREW, SHEET METAL #12 x 2″

WINGBOARD ANGLE MOUNTING

5 WINGBOARD ANGLE, TOP

6 WINGBOARD ANGLE, SIDE

7

SCREW, SHEET METAL #8 x 3/8″

QTY.
2 4 4 7
1 2 2

NOTE: Kühl + models do not come with window mounting components. When mounting a cooling and heating model a window installation kit must be purchased separately.
KWIKS ­ For all ES and YS models.
KWIKM ­ For all EM and YM models.
KWIKL ­ For all EL and YL models.

ITEM NO
8 9 10 11

DESCRIPTION
WINGBOARD MOUNTING PARTS WINGBOARD (MASONITE) “J” TYPE SPEED NUT WINGBOARD CLIP (SPRING STEEL) SCREW, #8 x ½” PHILLIPS TRUSS HD.

WINDOW SEALING 12 SEALING GASKET (VINYL) 13 WINDOW SEAL GASKET (DARK FOAM) 14 CHASSIS SEAL GASKET (LIGHT FOAM)

FRR009
QTY.
1 4 4 4
1 1 1

19

wwww.sylvane.com 1 800-934-9194
q

920-198-00

Standard Window Installation

NOTE: Hardware and accessories used during installation are shown on page 18. Each part will be referred as Item No.

STEP 1.

Remove the chassis Entrygard retainer by removing the far right screw (See Figure 14), save this screw to reattach the chassis retainer after installation (Step 12). Also, remove and discard the two retainer screws and washers located at the rear of the unit (See Figure 14).

Figure 15

CAUTION

Use Handle Locations [both sides]

Handle Use Use handle on both sides to pull unit from sleeve.
Do not push, pull or lift from center of support.

STEP 2. STEP 3.

Hold the cabinet stationary, then use the hand grips on both ends of the control unit support bracket to pull the chassis out of the cabinet (See Figure 15).
Remove the large white foam blocks used to restrain the compressor during shipment (See Figure 16). Inspect base pan for dislodged white foam blocks and remove. Do not remove any other foam parts.

STEP 4.

CONTROL UNIT SUPPORT BRACKET

FRR012

Anchor the side angles (Item 6) by engaging the tabs of the lower sill plate (See Figure 17, Detail B-2) with the loops of the side angle. Engage the tabs of the top angle (Item 5) with the top loops of the side angle (See Figure 17, Detail B-1). Install two (2) screws (Item 7) to secure the top angle tabs and the side angle to the cabinet (See Figure 17, Detail B-1).

Figure 14

RETAINER SCREWS AND WASHERS

ENTRYGARD RETAINER WIRE

FAR RIGHT SCREW
20

FRR011

wwww.sylvane.com 1 800-934-9194
q

920-198-00

CAUTION

Remove Shipping Blocks Prior to operating the unit remove the foam shipping blocks.
Failure to do so may result in damage to the unit which is not covered by the manufacturer’s warranty!

STEP 5. Check the window sill and frame to be sure they are in good condition and firmly anchored to the wall. Repair if necessary.

STEP 6.

CABINET MOUNTING ­ Raise the lower window 1/4″ more than the height of the cabinet. Carefully slide the cabinet through the opening until the lower sill plate channel rests behind the window sill and the top angle rests against the window (See Figure 18). Center the cabinet within the opening. Drill three (3) 5/32″ diameter pilot holes into window sill using the holes in the cabinet sill plate as a guide. Install
three (3) #12 x 2″ long screws (Item 4) (See Figure 18).

NOTE: DO NOT LEVEL the cabinet from front to back. Make sure there is approximately 3/8″ to 1/2″ slope (1/8 to 1/4 bubble on level) toward the outside of the house.
Adjust the support brackets to provide an inside-to-outside slope for excess condensation drainage (Refer to Standard Window Installation, Figures 19 through 23). Tighten all screws.
Alternate support method A: If you have a wide window sill which prevents you from mounting the brackets as shown in Figure 22, try the following: Using the elongated holes and different hole locations in the cabinet, set the placement of the bracket to support the unit’s weight (Figure 22). Tighten all screws.
Alternate support method B: If the window ledge gap is narrow, try the following. Bend the bracket end tab flat. Cut the bracket in two (2) places as shown in Figure 23. Bend the short piece so it will be vertical when installed. Adjust the placement as required. Tighten all screws.

STEP 8.

Measure and cut the wingboard panels (fit with about 1/8″ clearance) from the supplied Masonite (Item 8) to fit the space between the window side channels and cabinet. (Figure 24). Make sure you include the depth of the window channel.

NOTICE

STEP 7.

OUTSIDE SUPPORT MOUNTING ­ Refer to Figures 19 and 20. Assemble the support brackets (Item 1) to the bottom of the cabinet with four (4) 10-24 1″ long screws (Item 2) and four 10-24 flat nuts (Item 3). Adjust the support brackets, using a combination of the elongated holes of the bracket and different hole locations in the cabinet, to bring the bottom support bracket pads in contact with the wall. A 1″ x 4″ or 2″ x 4″ SPACER SHOULD BE USED BETWEEN THE WALL AND SUPPORT THE BRACKETS WHEN INSTALLED ON ALUMINUM OR VINYL SIDING. Drill 5/32″ diameter pilot holes and secure the brackets to the wall with two (2) 12A x 2″ long screws (Item 4).

For YOUR security and safety, YOU must provide a means of preventing the upper part of the window from opening.

STEP 9.

To assemble the wingboard panels, push on the “J” type speed nuts (Item 9) and spring steel clips (Item 10) (See Figures 25) on page 26. Secure each panel with two (2) screws (Item 11).

Figure 16

TOP VIEW OF UNIT

REMOVE AND DISCARD SCREWS

BACK

LEFT SIDE
REMOVE AND DISCARD FOAM BLOCKS

COMPRESSOR

FAN MOTOR

RIGHT SIDE

EVAPORATOR COIL
FRONT
wwww.sylvane.com 1 800-934-9194
q

REMOVE AND SAVE SCREW FOR RE-INSTALLATION
FRR045
21

Figure 17 CABINET

920-198-00 TOP ANGLE (ITEM 5)

8 x 3/8″ LONG SCREW (ITEM 7) 2 REQUIRED

Figure 18

TAB
SIDE ANGLE (ITEM 6) 2 REQUIRED

DETAIL B-2

SILL PLATE TAB

DETAIL B-1

TAB LOOP
FRR013

CENTER CABINET IN WINDOW SIDE TO SIDE
DRILL (3) 5/32″ DIA. PILOT HOLES AND INSTALL (3) #12 x 2″
LONG SCREWS (ITEM 4)
WINDOW SILL
LOCATE SILL PLATE GUIDE CHANNEL JUST BACK OF WINDOW SILL
22
wwww.sylvane.com 1 800-934-9194
q

TOP ANGLE (ITEM 5) PULL WINDOW SASH DOWN BEHIND TOP ANGLE
SIDE ANGLE (ITEM 6)
FRR014

Figure 19

920-198-00 3/8″ SLOPE DOWN

10-24 x 1″ HEX HD. SCREW (ITEM 2)

SUPPORT BRACKET (ITEM 1)

SPACER SHOULD BE USED BETWEEN WALL AND BRACKET WHEN INSTALLED ON ALUMINUM OR VINYL SIDING.

12 x 2″ SCREW (ITEM 4)

10-24 x FLAT WELD NUT (ITEM 3)

Figure 20

SUPPORT BRACKET (ITEM 1)
FRR015
3/8″ SLOPE DOWN

CONDENSER AIR OUTLET
CONDENSER AIR INLETS #10-24 SCREW #10-24 FLAT WELD NUT #12 x 2″ SHEET METAL SCREW (ITEM 4) SPACER SHOULD BE USED BETWEEN WALL AND BRACKET WHEN INSTALLED ON ALUMINUM OR VINYL SIDING.
wwww.sylvane.com 1 800-934-9194
q

FRR016
23

Figure 21

920-198-00

3/8″ SLOPE DOWN

STONE LEDGE Figure 22

CONDENSER AIR INLETS #10-24 SCREW #10-24 FLAT WELD NUT

12 x 2″ SHEET METAL SCREW (ITEM 4) SPACER

FRR017

3/8″ SLOPE DOWN

10-24 SCREW

STRAIGHTEN TAB TO LAY FLAT ALONG THE BOTTOM RAIL OF THE SHELL

10-24 FLAT WELD NUT

SECURE THE LONGEST SIDE OF THE BRACKET TO THE SHELL
ADJUST IN OR OUT TO REST ON THE LEDGE
STONE LEDGE

FRR018

24

wwww.sylvane.com 1 800-934-9194
q

Figure 23

920-198-00 3/8″ SLOPE DOWN

Figure 24

10-24 SCREW

DIMENSION “A”
CUT HERE

CUT TO FIT DIMENSION “A” AND BEND DOWN TO FORM A VERTICAL LEG.

10-24 FLAT WELD NUT STONE LEDGE

OUTSIDE WALL

DISCARD SHADED AREA

A
FRR019

MEASURE DISTANCE “B” TO INSIDE OF THE CHANNEL ON EACH SIDE.
CUT HERE AND DISCARD CENTER WASTE MATERIAL.
B

B

WINGBOARD

B B

SUBTRACT 1/8″ FROM DIMENSION “B” AND MEASURE FROM THE EDGE OF THE WINGBOARD (ITEM 8), MARK, SCORE AND CUT WITH APPROPRIATE CUTTING TOOL.
FRR020
25

wwww.sylvane.com 1 800-934-9194
q

920-198-00

STEP 10.

INSTALL THE WINDOW SEALING GASKETS ­ Measure and cut the vinyl window seal gasket (grey color, Item 12) to fit the width of the window, and install as shown in Figure 29. Pull the window sash down behind the gasket. Measure and cut the dark foam window seal gasket (Item 13) and install it between the upper glass panel and the top part of the lower window sash (Figure 29).

CAUTION
Excessive Weight Hazard Use two or more people when installing your air conditioner.
Failure to do so can result in back or other injury.

CAUTION
Cut/Sever Although great care has been taken to minimize sharp edges in the construction of your unit, use gloves or other hand protection when handling unit
Failure to do so can result in minor to moderate personal injury.

STEP 11.

Carefully team lift the chassis and set it into the cabinet. Slide the chassis stopping approximately 3″ from full insertion. Insert the chassis seal gasket (Item 14) one inch deep between the chassis and the cabinet (See Figure 29) as shown on page 28. A paint stir stick or ruler might be helpful here. Begin inserting the gasket at either bottom corner and go up the side, across the top, and down the opposite side. Then push the chassis all the way into the cabinet.

NOTE: If the chassis seal gasket is not installed or installed improperly, the operation of the unit will be negatively affected. Operational noise and outside noise will also be amplified.

STEP 12. Reattach the entry guard chassis entry guard retainer wire with the same screw retained in Step 1 (See Figure 14).

Figure 25
“J” TYPE SPEED NUT (ITEM #9) 2 REQUIRED

SPRING STEEL CLIP (ITEM 10) 2 REQUIRED

CUT WINGBOARD
PANEL

3″
CUT EDGE
3″

ROTATED 90°

CENTER THE HOLE IN THE SPEED NUT OVER THE SLOT IN THE WINGBOARD PANEL

SLIDE CLIP OVER CUT EDGE OF WINGBOARD PANEL

26
wwww.sylvane.com 1 800-934-9194
q

FRR021

920-198-00

Figure 26

TOP OF CABINET

PLACE WINGBOARD PANEL IN WINDOW JAM TO COMPRESS THE SPRINGS INSIDE THE RUNNERS, AND SWING THE WINGBOARD PANELS INTO PLACE AS INDICATED BY THE DASHED LINES.

WINDOW JAM

CLIP (ITEM 10)

Figure 27

INSERT VINYL WINDOW SEAL GASKET OVER TOP ANGLE TO WINGBOARD (ITEM 12)

INSERT FOAM WINDOW SEAL GASKET (ITEM 13)

B

SECTION A-A

B

LOWER WINDOW SASH

A A

VINYL WINDOW GASKET

TOP WINGBOARD ANGLE

SECURE THE SIDE WINGBOARD PANELS TO THE SIDE ANGLES WITH FOUR (4) #8 x 1/2″ LONG SCREWS (ITEM 11), TWO ON EACH SIDE.

FRR022

SECTION B-B

FRR023

27
wwww.sylvane.com 1 800-934-9194
q

920-198-00

OPTIONAL: The factory assembles the supply cord so that it exits the left side of the unit at the bottom. At the consumer’s discretion, the supply cord can be routed to exit the right side of the unit. To do this, route the supply cord to the right side. Pull the supply cord taunt through the loops (Refer to Cord Routing Change, Figure 37) and route the cord down.

STEP 13.

To attach and prevent damage to the front grille align the cord notch over the cord and center the fresh air lever, then align and tighten the four (4) captive screws as indicated by the arrows in Figure 28. Before closing the front panel, be sure the filter is in place. Make sure curtains do not block the side air intakes.

STEP 14. You are now ready to control the comfort level of the room.

Use Tool Provided
Please use the provided tool to attach the decorative front to the chassis. Figure 28
USE HAND TOOLS DO NOT OVER TIGHTEN
B
LOCATION OF GRILLE REMOVAL TOOL

Figure 29

FRR053

POWER CORD CLIP

CHASSIS SEAL GASKET (ITEM 14)

NOTE: WHEN INSTALLING THE CHASSIS SEAL GASKET; BEGIN AT EITHER BOTTOM CORNER AND GO UP THE SIDE & ACROSS THE TOP & DOWN THE OPPOSITE SIDE.
FRR024

28
www.sylvane.com 1 800-934-9194
q

920-198-00
THIS PAGE INTENTIONALLY LEFT BLANK
29
www.sylvane.com 1 800-934-9194
q

920-198-00

Cord Routing Change
Unplug unit.

STEP 15. Carefully pull out electrical control panel 1″, but not all the way. Figure 32

WARNING
Electrical Shock Hazard
Make sure your electrical receptacle has the same configuration as your air conditioner’s plug. If different, consult a Licensed Electrician.
Do not use plug adapters. Do not use an extension cord. Do not remove ground prong.
Always plug into a grounded 3 prong oulet. Failure to follow these instructions can result in death, fire, or electrical shock.

1 INCH

For convenience and optimum appearance the direction that the power cord exits the unit may be changed from left to right by following the procedure below. Select the exit location on the left or right based on proximity to the power outlet.
Figure 30
ELECTRICAL CONTROL PANEL

FRR056
STEP 16. Pull electrical cord strain relief downward until free and rotate 90 degrees to the right.
Figure 33

NOTE: DECORATIVE FRONT REMOVED USE TOOL PROVIDED. (SEE FIGURE 28 FOR LOCATION OF TOOL).
FRR054
Remove 3 screws as shown from the electrical control panel. Save to reinstall later.
Figure 31
ELECTRICAL CONTROL PANEL SCREWS (3)

90°

ELECTRICAL CORD STRAIN RELIEF

FRR057

STEP 17. Push electrical cord strain relief back upward into the electrical control panel.

Figure 34

FRR055

ENSURE THE ELECTRICAL CORD STRAIN RELIEF IS FLUSH WITH THE TOP OF ELECTRICAL CONTROL PANEL
FRR058

30

www.sylvane.com 1 800-934-9194
q

920-198-00

STEP 18. Carefully push electrical control panel back into chassis.
Figure 35
ELECTRICAL CONTROL PANEL

STEP 20. If running power cord to the right of the unit install the cord into the cord retainer clips along the bottom front of the unit.
Figure 37

FRR059
STEP 19. Reinstall the 3 screws removed earlier to secure electrical control panel.
Figure 36

CORD RETAINER CLIPS

FRONT GRILLE

POWER CORD

FRR061

ELECTRICAL CONTROL PANEL SCREWS (3) (RETAINED FROM STEP 1)

FRR060

31
www.sylvane.com 1 800-934-9194
q

920-198-00

Through-the-Wall Installation

The following instructions apply to wood, masonry, brick, concrete or cinder block wall construction.

STEP 1. Follow steps 1, 2, 3, and 4 of the “STANDARD WINDOW INSTALLATION” instructions beginning on page 20.

STEP 2.

CABINET PREPARATION ­ Remove the sill plate from the cabinet by removing two (4) nuts and screws (Figure 38). Note that the chassis retainer is secured by a right side nut and screw (Detail A, Figure 38). Bend the tabs of the sill plate down into its channel at both ends of the plate or cut them off (Detail B, Figure 38) Rotate the sill plate 180° (end-to-end, Detail B, Figure 38) and reinstall. Reverse the orientation of the nuts and screws, so that the head of the screws are on the underside of cabinet facing up and the nuts are on top (Detail C, Figure 38). Ensure that the chassis retainer is reinstalled as shown in the detail.

NOTICE

The outside cabinet condenser air intake louvers MUST NOT BE BLOCKED by extra thick walls.

A B

Table 4

FINISHED

SMALL

DIMENSION CHASSIS

MEDIUM CHASSIS

LARGE CHASSIS

A

16 3/16″

18 3/16″

20 3/8″

B

26 3/16″

26 3/16″

28 1/4″

Note: These dimensions are for finished opening size.

STEP 3.

WALL PREPARATION ­ The maximum wall thickness permissible without special construction is determined by the model size to be installed. Observe the maximum wall thickness shown in Figure 39. Walls exceeding the maximum thickness shown in the chart, should be altered as shown in Figure 39.

STEP 4.

CHECKING WIRING AND PLUMBING ­ Check for wiring and plumbing inside and outside of the wall to be sure none will be damaged when the cabinet framework is being constructed.

STEP 5.

OPENING CONSTRUCTION ­ Depending upon size of unit to be installed, lay out the hole dimensions per Table 4. Cut and frame-in the opening to finished dimensions. If the wall construction is typical frame or 2″ x 4″ studding with brick or stone veneers, locate the opening next to one of the studs. For masonry, concrete or cinder block walls, locate opening
for your convenience (See Figures 40, 41, and 42).

32
www.sylvane.com 1 800-934-9194
q

Figure 38 CABINET

920-198-00

BEFORE

CABINET

AFTER

SILL PLATE
TURN SILL PLATE END TO END

SCREW (4 REQUIRED)
NOTE: HOLES IN SILL PLATE MOVED TO BACK SIDE
DETAIL A
NUT (4 REQUIRED)

NUT (4 REQUIRED)
DETAIL C

Figure 39
A

DETAIL B
BEND TABS DOWN

SCREW (4 REQUIRED)

NOTE: SCREW AND NUT ORIENTATION NOW REVERSED.

FRR026

MAXIMUM WALL THICKNESS
CONDENSER AIR INTAKE LOUVERS

TOP VIEW

CONDITIONED ROOM SIDE AIR

MODEL
SMALL CHASSIS MEDIUM CHASSIS LARGE CHASSIS

A
7-3/8″ 7-3/8″ 15-1/8″

TOP VIEW SHOWING BEVELED SIDES FOR AIR INTAKE. WALL BELOW UNIT MUST BE BEVELED ALSO.
CONDENSER AIR OUTLET / REJECTED
HEATED AIR

2″ MINIMUM BOTH SIDES
CONDENSER AIR INTAKE LOUVERS

NOTE: CONDENSER AIR INLETS AND OUTLETS MUST BE UNOBSTRUCTED TO AVOID THE RECIRCULATION OF REJECTED HEATED AIR.

FRR027

33
www.sylvane.com 1 800-934-9194
q

Figure 40 CAULK ALL SIDES INSIDE AND OUTSIDE
CABINET

920-198-00 Figure 41
CAULK ALL SIDES INSIDE AND OUTSIDE CABINET

SHIM TO FILL IN VOID AT THE TOP AND SIDES WITH WOOD AS REQUIRED.

ELECTRICAL RECEPTACLE (SEE FIG. 42 FOR LOCATION NOTE)

FRR028

Figure 42

CAULK ALL SIDES INSIDE AND OUTSIDE

CABINET MORTAR

SHIM TO FILL IN VOID AT THE TOP AND SIDES WITH WOOD AS REQUIRED.

ELECTRICAL RECEPTACLE (SEE FIG. 42 FOR LOCATION NOTE)

FRR029

POINT “Y”

POINT “X”

ELECTRICAL RECEPTACLE

From Point “X” Small/Medium

115V

69″

230V

45″

From Point “Y” Small/Medium

115V

45″

230V

21″

Large N/A 45″
Large N/A 20″

FRR030

34

www.sylvane.com 1 800-934-9194
q

920-198-00

STEP 6.

Slide the cabinet into the hole far enough to allow the guide-channel of the sill plate to contact the inside wall surface (Figure 20).

STEP 7.

Drill three (3) 5/32″ diameter pilot holes (use the sill-plate holes as a guide) into the frame and install three (3) #12 x 2″ long screws (Item 4) (Figure 20).

NOTE:

Alternate fasteners are required when securing the sill plate or support brackets to material other than wood (cinder block, brick, masonry or concrete). These items can be purchased at your local hardware store.

EXPANSION ANCHOR BOLT

NOTE: DO NOT LEVEL the cabinet from front to back. Make sure there is approximately 3/8″ to 1/2″ slope (1/8 to 1/4 bubble on the level) toward the outside of the house.

STEP 8.

Drill two (2) 5/32″ diameter pilot holes in each cabinet side at the locations shown (Figure 20) and install four (4) #12 x 2″ screws (Item 4). Provided that Step 5 (hole construction) provides a sturdy mount with solid vertical studs, support brackets may not be required. The installation must support the weight of the unit plus an additional weight of 400 pounds on the rear of the cabinet. If support brackets (Item 1) are available, they can be installed as shown in Figure 20.

STEP 9.

Complete the installation by following steps 12 through 15 of “STANDARD WINDOW INSTALLATION” instructions, page 20.

MOLLY OR TOGGLE BOLT Figure 43
TRIM MOULDING
3″ 4″
SCREW #12 x 2″ LONG (USE 3) (ITEM 4) SILL PLATE GUIDE CHANNEL
INSIDE WALL SURFACE

CAULK ALL SIDES WEATHER TIGHT INSIDE AND OUTSIDE
3/8″ SLOPE DOWN
NOTE: SUPPORT BRACKET MAY BE OMITTED FROM THROUGH-THE-WALL INSTALLATIONS IF THE CABINET IS SECURED AS FOLLOWS. DRILL TWO HOLES IN EACH SIDE AND INSTALL 4 FASTENERS (2 EACH SIDE). USE #12 x 2″ SCREWS, (ITEM 4). TOGGLE BOLTS OR EXPANSION BOLTS MAY BE REQUIRED.
CABINET
SUPPORT BRACKETS

SCREW #12 x 2″ LONG DRILL 5/32″ DIA. PILOT HOLES.

FRR031

35
www.sylvane.com 1 800-934-9194
q

920-198-00

Programmable Thermostat
Your unit features an advanced 7 day programmable thermostat feature that can be used to turn the unit on or off or even change modes and maintain temperatures throughout the day.
Factory settings are shown in addendum 1 (Schedule Table with Energy Saving Values). These values can be changed by following the procedures in the preceding paragraphs. Basic options are: Four (4) day groups.
1. Monday through Friday.
2. Saturday and Sunday only.
3. Monday through Sunday.
4. Individual days (Mon thru Sun).
Each of the day groups have four (4) time periods: WAKE (06:00), AWAY (08:00), RETURN (18:00), and NIGHT (22:00).
The start time for each of the time periods can be changed. In addition, each time period can have its own temperature and fan mode.
For example, let’s say you are in a cool climate region. You leave for work at 08:00 and return home around 18:30. You can set the temperature lower while you are away from your home. At 18:00, you set the temperature higher for the RETURN period so the room is nice and comfortable when you arrive.
Set Schedule Sequence ­ 1 Wake Period

SYSTEM

BACK

FAN MODE

AUTO

SET POINT<- COOL F

FAN SPEED

AUTO

SCHEDULE

DISPLAY ENTER

FRR032
Press and hold SCHEDULE for three (3) seconds to enter the schedule setting mode. If left inactive for five (5) minutes, the unit exits the schedule setting mode and returns to normal display without saving any settings that might have been changed. To exit and save the changes, press and hold SCHEDULE for three (3) seconds. All changed parameters will be saved. The BACK key allows the user to back up through the menus.

SYSTEM

BACK

FAN MODE
FAN SPEED
SCHEDULE

MTWT F S S WAKE

A M
DISPLAY ENTER

FRR033
When the schedule setting mode is entered, a confirmation sound plays and the schedule icon blinks. The display begins with all weekday (MTWTF) dots lit. Changes made will be global to all weekdays.

SYSTEM

BACK

FAN MODE
FAN SPEED
SCHEDULE

MTWT F S S WAKE

A M
DISPLAY ENTER

FRR034
The user can select a different day group by pressing . SCHEDULE If the user continues to press , SCHEDULE the system will cycle through all the day groups in the following order: MTWTFSS, Monday thru Sunday, M, T, W, Th, F, Sat, Sun. Note the last day group is each individual day. In other words, the user can adjust each of the four (4) time period start times per day. This is a real helpful feature if you have an adjustable work shift. Each day group begins showing the start time for the wake time period.

SYSTEM

BACK

FAN MODE
A M
FAN SPEED

SCHEDULE

MTWT F S S WAKE

DISPLAY ENTER

FRR035

To change the time, press (UP) or (DOWN) to increment/decrement

the time by 15 minute jumps.

Once the correct time is set, press

DISPLAY ENTER

to

advance to the next step.

Set Schedule Sequence ­ 2 Wake Period

SYSTEM

BACK

FAN

MODE

CONTINUOUS

F

FAN SPEED

SCHEDULE

MTWT F S S WAKE

DISPLAY ENTER

FRR036
Now you can adjust the settings for SYSTEM, FAN MODE, FAN SPEED and TEMPERATURE.

SYSTEM

BACK

FAN MODE

CONTINUOUS

SET POINT<- COOL F

FAN SPEED
SCHEDULE

MTWT F S S WAKE

DISPLAY ENTER

FRR037

FAN

FAN

Press , SYSTEM , or MODE SPEED to change the perspective option. Use the

(UP) or (DOWN) to adjust the cool setpoint.

36
www.sylvane.com 1 800-934-9194
q

920-198-00

SYSTEM

AUTO

BACK

FAN MODE

CONTINUOUS

HEAT ->SET POINT F

FAN SPEED
SCHEDULE

MTWT F S S WAKE

DISPLAY ENTER

FRR038

If the system mode is set to AUTO (Heat-Cool Unit only), a 2nd temperature labeled “Heat Set Point” displays. Use (UP) or (DOWN) arrows

to increment/decrement the heat temperature. The other parameters

(SYSTEM, FAN SPEED, FAN MODE) cannot be changed on this screen.

The temperature range for AUTO mode must remain a minimum of 3

degrees apart at all times. If the high or low temperature is adjusted too

close to its counterpart, that temperature not being directly changed will

increase/decrease as needed to maintain the 3 degree spread. The user

presses

DISPLAY ENTER

to advance to the next time period.

SYSTEM

BACK

FAN MODE

CONTINUOUS

FAN SPEED
SCHEDULE

AUTO MTWT F S S WAKE

DISPLAY ENTER

FRR039
If the user selects FAN-Only mode, the temperature display is replaced by the word FAN. Options for FAN-Only mode are: CONTINUOUS, adjust the FAN SPEED; AUTO, fan speed varies depending on system needs.

SYSTEM

BACK

FAN MODE

FAN SPEED
SCHEDULE

MTWT F S S WAKE

DISPLAY ENTER

FRR040
If the user wants the air conditioner to power down for a period of time, pressing SYSTEM a fifth time will set the unit options to OFF and put the unit into hibernation until the next scheduled period. This feature is available during schedule setup only. In on-the-fly use, the user just presses the power button.

Set Schedule ­ Away, Return, Night Periods

SYSTEM

BACK

FAN MODE
FAN SPEED
SCHEDULE

MTWT F S S

AWAY

A M
DISPLAY ENTER

FRR042
Each of the additional periods (Away, Return, Night) are programmed identical to the programming for the Wake period. The appropriate period identifier (Away, Return, Night) displays during each programming sequence.
Once the user has programmed all four (4) time periods, the program goes to the next day or day group. For example, if individual days are being programmed, the program will go from Mon to Tues leading the user through 4 periods for Tues until it reaches the end of the week.

NOTE:

Day group sequence is as follows: Monday through Friday (weekday), Saturday ­ Sunday (weekend), Monday through Sunday (7-day), and individual days Mon Tue Wed Thru Fri Sat Sun.

Note that the process follows a continuous loop until the user decides to exit.

When the user has completed setting start times and options (or at any point in the process) they can press SCHEDULE to toggle to the next day (or set of days), or they can press and hold SCHEDULE for 3 seconds to save their changes and exit the set schedule mode.

SYSTEM
FAN MODE
FAN SPEED

AUTO AUTO

SCHEDULE

ROOM TEMP

Schedule Mode Completed.

SET POINT<- COOL F

BACK

DISPLAY ENTER
FRR043

SYSTEM

BACK

FAN MODE

FAN SPEED
SCHEDULE

MTWT F S S WAKE

DISPLAY ENTER

FRR041

If the user should decide they don’t want to use all four time periods for the

day, they can set any period to be skipped by pressing . SYSTEM This will blank

out the options and display the word SKIP. This can be undone by either

pressing SYSTEM again or pressing the (UP) or (DOWN) arrows.

The display defaults to the setting immediately prior to the user advancing

to SKIP.

Press

, DISPLAY
ENTER

to continue on to the next time period.

37

www.sylvane.com 1 800-934-9194
q

920-198-00

Final Inspection & Start-up Checklist

Inspect and ensure that all components and accessories have been installed properly and that they have not been damaged during the installation progress.
Check the condensate water drain(s) to ensure that they are adequate for the removal of condensate water, and that they meet the approval of the end user.
Ensure that all installation instructions concerning clearances around the unit have been adhered to. Check to ensure that the unit air filter, indoor coil, and outdoor coil are free from any obstructions.
Ensure that the circuit breaker(s) or fuse(s) and supply circuit wire size have been sized correctly. If the unit was supplied with a power supply cord, insure that it is stored properly.
Ensure that the entire installation is in compliance with all applicable national and local codes and ordinances having jurisdiction.
Secure components and accessories, such as a decorative front cover.
Start the unit and check for proper operation of all components in each mode of operation.
Instruct the owner or operator of the units operation, and the manufacturer’s Routine Maintenance.
NOTE: A log for recording the dates of maintenance and/or service is recommended.
Present the owner or operator of the equipment with the Installation & Operation Manual, all accessory installation instructions, and the name, address and telephone number of the Authorized Friedrich Warranty Service Company in the area for future reference if necessary.
This is a warm weather appliance
Your air conditioner is designed to cool in warm weather when the outside temperature is above 60° F (15.6° C) and below 115° F (46.1° C), so it won’t cool a room if it is already cool outside. If you want to cool a room in the spring or fall, select the FAN ONLY mode and set the Fresh Air/Exhaust air control to Fresh Air. This will bring in a supply of cooler outside air.
Condensation is normal
Air conditioners actually pump the heat and humidity from your room to the outside. Humidity becomes water, and your air conditioner will use most of the water to keep the outside coil cool. If there is excessive humidity, there may be excess water that will drip outside. This is normal operation.
Frosting
This usually occurs because of insufficient airflow across the coils, a dirty filter, cool damp weather, or all of these. Set the SYSTEM mode to FAN ONLY and the frost will disappear. Setting the thermostat a little warmer will probably prevent the frosting from recurring.
Noises
All air conditioners make some noise. Friedrich units are designed to operate as quietly as possible. An air conditioner mounted in a wall is quieter than one mounted in a window. It is important to ensure that the chassis seal gasket (Item 14) is properly installed (refer to installation instructions).

Heat pumps operate differently
If your unit is a “Y”, or heat pump model, there are some things that you will want to be aware of. Some functions of a heat pump differ from your unit when it is used for heating:
1. It is normal for ice to form on the outdoor coil of the heat pump. Moisture in the outside air, passing over the coil when very cold, will form ice.
2. If the outdoor temperature drops below 37° F (3° C), your heat pump will automatically turn on the electric resistance heat. When the temperature rises to 40° F (4° C), the compressor will resume the heat pump operation. If your unit is a 115 volt model (YS10), it is designed for use in warmer climates and does not have an electrical heat feature, and will not provide adequate heat below 37° F (2.8° C).
Control Panel Battery Change Procedure
Remove the grille, by loosening four (4) captive screws (See Figure 44). In the upper left corner, remove one (1) screw on the battery retaining door (See Figure 45). Remove and replace the battery (CR2450). Reinstall the battery retaining door. Align the grille guide pins then tighten the four (4) captive screws. Before closing the grille panel door, check the filter. Clean or replace it as necessary.
Figure 44
USE HAND TOOLS DO NOT OVER TIGHTEN

  1. USE HAND TOOLS WHEN INSTALLING AND REMOVING FRONT PANEL. DO NOT OVERTIGHTEN SCREWS.
  2. DISCONNECT POWER AND FOLLOW ALL

LABELED WARNINGS WHEN FRONT PANEL

IS REMOVED.

FRR010

Figure 45

38
www.sylvane.com 1 800-934-9194
q

920-198-00

Routine Maintenance
To ensure proper unit operation, the air filters should be cleaned at least monthly, and more frequently if conditions warrant. The unit must be turned off before the filters are cleaned.
WARNING
Electrical Shock Hazard
Make sure your electrical receptacle has the same configuration as your air conditioner’s plug. If different, consult a Licensed Electrician.
Do not use plug adapters. Do not use an extension cord. Do not remove ground prong.
Always plug into a grounded 3 prong oulet. Failure to follow these instructions can result in death, fire, or electrical shock.

To Remove, Wash and Replace Filter
Lower front panel (See Figure 2). Use handle on filter to flex filter up and out of retainer. Remove filter from unit (See Figure 3). Clean filter monthly or more frequently if needed. Refer to accessories section for filter options.
Coils & Chassis

NOTE:

Do not use a caustic coil cleaning agent on coils or base pan. Use a biodegradable cleaning agent and degreaser. The use of harsh cleaning materials may lead to deterioration of the aluminum fins or the coil end plates.

The indoor coil and outdoor coils and base pan should be inspected periodically (annually or semi-annually) and cleaned of all debris (lint, dirt, leaves, paper, etc.) as necessary. Under extreme conditions, more frequent cleaning may be required. Clean the coils and base pan with a soft brush and compressed air or vacuum. A pressure washer may also be used, however, you must be careful not to bend the aluminum fin pack. Use a sweeping up and down motion in the direction of the vertical aluminum fin pack when pressure cleaning coils.

NOTE: It is extremely important to insure that none of the electrical and/or electronic parts of the unit get wet. Be sure to cover all electrical components to protect them from water or spray.
Decorative Front

Use a damp (not wet) cloth when cleaning the control area to prevent water from entering the unit, and possibly damaging the electronic control.
The decorative front and the cabinet can be cleaned with warm water and a mild liquid detergent. Do NOT use solvents or hydrocarbon based cleaners such as acetone, naphtha, gasoline, benzene, etc.
The indoor coil can be vacuumed with a dusting attachment if it appears to be dirty. DO NOT BEND FINS. The outdoor coil can be gently sprayed with a hose if you can get to it. If not, you might call your dealer for a more thorough cleaning when needed.
The air filter should be inspected weekly and cleaned if needed by vacuuming with a dust attachment or by cleaning in the sink using warm water and a mild dishwashing detergent. Dry the filter thoroughly before reinstalling. Use caution the coil surface can be sharp.

Fan Motor & Compressor

The fan motor & compressor are permanently lubricated, and require no additional lubrication.

Wall Sleeve
Inspect the inside of the wall sleeve and drain system periodically (annually or semi-annually) and clean as required. Under extreme conditions, more frequent cleaning may be necessary. Clean both of these areas with an antibacterial and antifungal cleaner. Rinse both items thoroughly with water and ensure that the drain outlets are operating correctly. Check the sealant around the sleeve and reseal areas as needed.
Service and Assistance
Before calling for service, please check the “Troubleshooting Tips” section on pages 40 and 41. This may help you to find the answer to your problem, avoid unnecessary service calls, and save you the cost of a service call if the problem is not due to the product itself. If you have checked the “Basic Troubleshooting” section and still need help, it is available as follows:
You can find the name of your local Authorized Service Provider by visiting our web site at www.friedrich.com.
If you require further assistance
You can call the Customer Support Call Center at 1-800-541-6645.
Before calling, please make sure that you have the complete model and serial number, and date of purchase of your equipment available. By providing us with this information, we will be better able to assist you.
Our specialists are able to assist you with:
Specifications and Features of our equipment. Referrals to dealers, and distributors. Use and Care Information. Recommended maintenance procedures. Installation information. Referrals to Authorized Service Providers and Parts depots.

Available Accessories

DC-2 Drain Kit ­ Part No. 01900235
In some installations, excess condensate water caused by extremely humid conditions, may result in an undesirable water drip such as on a patio or over an entryway. MODEL DC-2 DRAIN KIT (Part No. 01900-235) can be installed to drain excess condensation to an alternate location.
Carbon Filter Kits
The kits vary depending on the chassis size (small, medium, large). Each kit contains three (3) filters. WCFS ­ Carbon filter kit for small chassis models. WCFM ­ Carbon filter kit for medium chassis models. WCFL ­ Carbon filter kit for large chassis models.
Remote Wall Thermostats
RT4 ­ Digital wall thermostat hard wired with single speed fan. RT5 ­ Digital wall thermostat hard wired with two fan speed selection, battery backup and backlight display.
Window Installation Kits (Standard in Kühl Models without Heat)
KWIKS ­ For all ES and YS models. KWIKM ­ For all EM and YM models. KWIKL ­ For all EL and YL models.
See www.friedrich.com for additional accessories for your unit. 39

www.sylvane.com 1 800-934-9194
q

920-198-00

Troubleshooting Tips

COMPLAINT

CAUSE

SOLUTION

The unit is turned to the off position, Turn the unit to the on position and raise or

or the thermostat is satisfied.

lower temperature setting (as appropriate) to

call for operation.

The LCDI power cord is unplugged. Plug into a properly grounded 3 prong receptacle. See “Electrical Rating Tables” on pg. 6 for the proper receptacle type for your unit.

Unit does not operate.

The LCDI power cord has tripped (Reset button has popped out).

Press and release RESET (listen for click; Reset button latches and remains in) to resume
operation.

The circuit breaker has tripped or the supply circuit fuse has blown.

Reset the circuit breaker, or replace the fuse as applicable. If the problem continues, contact a
licensed electrician.

There has been a local power failure.

The unit will resume normal operFaitgiounreo4n4ce power has been restored.

Other appliances are being used on The unit requires a dedicated outlet circuit, not

the same circuit.

shared with other appliances.

Unit Trips Circuit Breaker or Blows Fuses.

An extension cord is being used.
The circuit breaker or time-delay fuse is not of the proper rating.

Do NOT use an extension cord with this or any other air conditioner.
Replace with a circuit breaker or time-delay fuse of the proper rating. See “Electrical Rating Tables” on pg. 6 for the proper circuit breaker/fuse rating for your unit. If the problem continues, contact a licensed electrician.

The LCDI power cord can trip

Press and release RESET (listen for click;

(Reset button pops out) due to

Reset button latches and remains in) to resume

disturbances on your power supply

normal operation.

line.

LCDI Power Cord Trips (Reset Button Pops Out).

Electrical overload, overheating, or cord pinching can trip (Reset button
pops out) the LCDI power cord.

Once the problem has been determined and corrected, press and release RESET (listen for click; Reset button latches and remains in) to resume normal operation.

NOTE: A damaged power supply cord must be replaced with a new power supply cord obtained from the product manufacturer and must not be repaired.

The return/discharge air grille is blocked.

Ensure that the return and/or discharge air paths are not blocked by curtains, blinds,
furniture, etc.

Windows or doors to the outside are Ensure that all windows and doors are closed. open.

The temperature is not set at a cool Adjust the Temperature control to a cooler or

enough/warm enough setting.

warmer setting as necessary.

Unit Does Not Cool/Heat Room Sufficiently, Or Cycles On And Off Too Frequently.

The filter is dirty or obstructed.
The indoor coil or outdoor coil is dirty or obstructed.

Clean the filter, (See Routine Maintenance), or remove obstruction.
Clean the coils, (See Routine Maintenance), or remove obstruction.

There is excessive heat or moisture Be sure to use exhaust vent fans while cooking

(cooking, showers, etc.) in the room.

or bathing and, if possible, try not to use heat

producing appliances during the hottest part of

the day.

The temperature of the room you are trying to cool is extremely hot.

Allow additional time for the air conditioner to cool off a very hot room.

40

www.sylvane.com 1 800-934-9194
q

920-198-00

Troubleshooting Tips (continued)

COMPLAINT
Unit Does Not Cool/Heat Room Sufficiently, Or Cycles On And Off Too Frequently (continued).
Unit Runs Too Much.

CAUSE

SOLUTION

The outside temperature is below 60° F (16° C).

Do not try to operate your air conditioner in the cooling mode when the outside temperature is below 60° F (16° C). The unit will not cool properly, and the unit may be damaged.

The digital control is set to fan cycling mode.

Since the fan does not circulate the room air continuously at this setting, the room air does not mix as well and hot (or cold) spots may result. Using the continuous fan setting is recommended to obtain optimum comfort levels.

The air conditioner has insufficient cooling capacity to match the heat
gain of the room.

Check the cooling capacity of your unit to ensure it is properly sized for the room in which it is installed. Room air conditioners are not designed to cool multiple rooms.

The air conditioner has insufficient heating capacity to match the heat
loss of the room.

Check the heating capacity of your unit. Air conditioners are sized to meet the cooling load, and heater size is then selected to meet the heating load. In extreme northern climates, room air conditioners may not be able to be used as a primary source of heat.

This may be due to an excessive heat load in the room.

If there are heat producing appliances in use in the room, or if the room is heavily occupied, the unit will need to run longer to remove the additional heat.

It may also be due to an improperly Be sure to use exhaust vent fans while cooking

sized unit.

or bathing and, if possible, try not to use heat

producing appliances during the hottest part of

the day.

This may be normal for higher efficiency (EER) air conditioners.

The use of higher efficiency components in your new air conditioner may result in the unit running longer than you feel it should. This may be more apparent, if it replaced an older, less efficient, model. The actual energy usage, however, will be significantly less when compared to older models.

You may notice that the discharge The energy efficiency ratio (EER) and cooling

air temperature of your new air

capacity rating (Btu/h) listed on the unit’s rating

conditioner may not seem as cold

plate are both agency certified.

as you may be accustomed to from

older units. This does not, however,

indicate a reduction in the cooling

capacity of the unit.

41
www.sylvane.com 1 800-934-9194
q

920-198-00

Addendum 1
Schedule Table with Energy Saving Values
Cool, Heat, Auto, Fan Only, Skip, OFF

Day of We e k Monday Monday Monday Monday

Sche dule Pe riod Wake RAewtuaryn RAewtuaryn Night

De fault Front Pane l
ON ON ON ON

De fault Walls tat
Of f Of f Of f Of f

De fault Mode Cool Cool Cool Cool

Fan M ode A uto A uto A uto A uto

Fan Spe e d
Low Low Low Low

Se t Point Coo l) (SSPC)
78 85 78 82

Auto Auto

Se t

Se t

Se t

Point Point He at Cool

Poin t He at

Tim e 6:00A M 8:00 AM 6:00PM 10:00PM

Day of We e k Tuesday Tuesday Tuesday Tuesday

Sche dule Pe riod Wake RAewtuaryn RAewtuaryn Night

De fault Front Pane l
ON ON ON ON

De fault Walls tat
Of f Of f Of f Of f

De fault Mode Cool Cool Cool Cool

Fan M ode A uto A uto A uto A uto

Fan Spe e d
Low Low Low Low

Se t Point Coo l) (SSPC)
78 85 78 82

Tim e 6:00A M 8:00 AM 6:00PM 10:00PM

Day of We e k Wednesday Wednesday Wednesday Wednesday

Sche dule Pe riod Wake RAewtuaryn RAewtuaryn Night

De fault Front Pane l
ON ON ON ON

De fault Walls tat
Of f Of f Of f Of f

De fault Mode Cool Cool Cool Cool

Fan M ode A uto A uto A uto A uto

Fan Spe e d
Low Low Low Low

Se t Point Coo l) (SSPC)
78 85 78 82

Tim e 6:00A M 8:00 AM 6:00PM 10:00PM

Day of We e k Thurs day Thurs day Thurs day Thurs day

Sche dule Pe riod Wake RAewtuaryn RAewtuaryn Night

De fault Front Pane l
ON ON ON ON

De fault Walls tat
Of f Of f Of f Of f

De fault Mode Cool Cool Cool Cool

Fan M ode A uto A uto A uto A uto

Fan Spe e d
Low Low Low Low

Se t Point Coo l) (SSPC)
78 85 78 82

Tim e 6:00A M 8:00 AM 6:00PM 10:00PM

Day of We e k Fr iday Fr iday Fr iday Fr iday

Sche dule Pe riod Wake RAewtuaryn RAewtuaryn Night

De fault Front Pane l
ON ON ON ON

De fault Walls tat
Of f Of f Of f Of f

De fault Mode Cool Cool Cool Cool

Fan M ode A uto A uto A uto A uto

Fan Spe e d
Low Low Low Low

Se t Point Coo l) (SSPC)
78 85 78 82

Auto Auto

Se t

Se t

Se t

Point Point Poin t

He at Cool He at

(SSPH) (SASPC) (SASPH)

Tim e 6:00A M 8:00 AM 6:00PM 10:00PM

Day of We e k Satur day Satur day Satur day Satur day

Sche dule Pe riod Wake RAewtuaryn RAewtuaryn Night

De fault Front Pane l
ON ON ON ON

De fault Walls tat
Of f Of f Of f Of f

De fault Mode Cool Cool Cool Cool

Fan M ode A uto A uto A uto A uto

Fan Spe e d
Low Low Low Low

Se t Point Coo l) (SSPC)
78 85 78 82

Auto Auto

Se t

Se t

Se t

Point Point Poin t

He at Cool He at

(SSPH) (SASPC) (SASPH)

Tim e 6:00A M 8:00 AM 6:00PM 10:00PM

Day of We e k Sunday Sunday Sunday Sunday

Sche dule Pe riod Wake RAewtuaryn RAewtuaryn Night

De fault Front Pane l
ON ON ON ON

De fault Walls tat
Of f Of f Of f Of f

De fault Mode Cool Cool Cool Cool

Fan M ode A uto A uto A uto A uto

Fan Spe e d
Low Low Low Low

Se t Point Coo l) (SSPC)
78 85 78 82

Auto Auto

Se t

Se t

Se t

Point Point Poin t

He at Cool He at

(SSPH) (SASPC) (SASPH)

Tim e 6:00A M 8:00 AM 6:00PM 10:00PM

42

www.sylvane.com 1 800-934-9194
q

920-198-00
Friedrich Air Conditioning Company P.O. Box 1540
San Antonio, TX 78295 210.357.4400
www.friedrich.com
ROOM AIR CONDITIONERS LIMITED WARRANTY
FIRST YEAR
ANY PART: If any part supplied by FRIEDRICH fails because of a defect in workmanship or material within twelve months from date of original purchase, FRIEDRICH will repair the product at no charge, provided room air conditioner is reasonably accessible for service. Any additional labor cost for removing inaccessible units and/or charges for mileage related to travel by a Service Agency that exceeds 25 miles one way will be the responsibility of the owner. This remedy is expressly agreed to be the exclusive remedy within twelve months from the date of the original purchase.
SECOND THROUGH FIFTH YEAR
SEALED REFRIGERANT SYSTEM: If the Sealed Refrigeration System (defined for this purpose as the compressor, condenser coil, evaporator coil, reversing valve, check valve, capillary, filter drier, and all interconnecting tubing) supplied by FRIEDRICH in your Room Air Conditioner fails because of a defect in workmanship or material within sixty months from date of purchase, FRIEDRICH will pay a labor allowance and parts necessary to repair the Sealed Refrigeration System; PROVIDED FRIEDRICH will not pay the cost of diagnosis of the problem, removal, freight charges, and transportation of the air conditioner to and from the Service Agency, and the reinstallation charges associated with repair of the Sealed Refrigeration System. All such cost will be the sole responsibility of the owner. This remedy is expressly agreed to be the exclusive remedy within sixty months from the date of the original purchase.
APPLICABILITY AND LIMITATIONS: This warranty is applicable only to units retained within the Fifty States of the U.S.A., District of Columbia, and Canada. This warranty is not applicable to:
1. Air filters or fuses. 2. Products on which the model and serial numbers have been removed. 3. Products which have defects or damage which results from improper installation, wiring, electrical current characteristics, or
maintenance; or caused by accident, misuse or abuse, fire, flood, alterations and/or misapplication of the product and/or units installed in a corrosive atmosphere, default or delay in performance caused by war, government restrictions or restraints, strikes, material shortages beyond the control of FRIEDRICH, or acts of God.
OBTAINING WARRANTY PERFORMANCE: Service will be provided by the FRIEDRICH Authorized Dealer or Service Organization in your area. They are listed in the Yellow Pages. If assistance is required in obtaining warranty performance, write to: Room Air Conditioner Service Manager, Friedrich Air Conditioning Co., P.O. Box 1540, San Antonio, TX 78295-1540.
LIMITATIONS: THIS WARRANTY IS GIVEN IN LIEU OF ALL OTHER WARRANTIES. Anything in the warranty notwithstanding, ANY IMPLIED WARRANTIES OF FITNESS FOR PARTICULAR PURPOSE AND/OR MERCHANTABILITY SHALL BE LIMITED TO THE DURATION OF THIS EXPRESS WARRANTY. MANUFACTURER EXPRESSLY DISCLAIMS AND EXCLUDES ANY LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGE FOR BREACH OF ANY EXPRESSED OR IMPLIED WARRANTY.
Performance of Friedrich’s Warranty obligation is limited to one of the following methods:
1. Repair of the unit 2. A refund to the customer for the prorated value of the unit based upon the remaining warranty period of the unit. 3. Providing a replacement unit of equal value
The method of fulfillment of the warranty obligation is at the sole discretion of Friedrich Air Conditioning.
NOTE: Some states do not allow limitations on how long an implied warranty lasts, or do not allow the limitation or exclusion of consequential or incidental damages, so the foregoing exclusions and limitations may not apply to you.
OTHER: This warranty gives you specific legal rights, and you may also have other rights which vary from state to state.
PROOF OF PURCHASE: Owner must provide proof of purchase in order to receive any warranty related services. All service calls for explaining the operation of this product will be the sole responsibility of the consumer. All warranty service must be provided by an Authorized FRIEDRICH Service Agency, unless authorized by FRIEDRICH prior to repairs being made.
(10-08) 43
www.sylvane.com 1 800-934-9194