HORMANN RC2 Security Door 65 Mm Thick Instructions
- June 16, 2024
- HORMANN
Table of Contents
HORMANN RC2 Security Door 65 Mm Thick
Product Information
Specifications
- Product Name: Einbruchhemmender Beschlag Klasse RC2
- Application Class: RC2
- Standard: DIN / TS 18194
Product Usage Instructions
About these instructions
These instructions are original operating instructions as outlined in EC
Directive 2006/42/EC and are divided into a text and illustrated section. They
contain important information on the product, and especially safety
instructions and warnings. Read through the instructions carefully and keep
them in a safe place.
Warnings used
- WARNING: Indicates a danger that can lead to death or serious injury.
- ATTENTION: Indicates a danger that can lead to damage or destruction of the product.
Warning symbols used
- See instructions: Check
- Remove and recycle the component/packaging: Tighten the screws firmly
- Tighten the screws by hand:
Safety instructions
Intended use
This garage door is designed and intended for private use only. Continuous
operation is not permitted.
General safety instructions
On-site changes may void the CE compliance.
Environment conditions
ATTENTION:
Damage caused by temperature differences. Differences in the outside and
inside temperatures may result in deflection of the door elements and foam
break (bi-metal effect). There is the risk of damage during door operation.
Operating conditions observed. The door is intended for the following ambient
temperatures:
FAQ
-
Q: What is the application class of this product?
A: The application class of this product is RC2. -
Q: What are the safety instructions for this product?
A: The safety instructions include using the garage door for private use only and avoiding continuous operation. On-site changes may void the CE compliance.
We are delighted that you have chosen a product from our company.
About these instructions
These instructions are original operating instructions as outlined in EC Directive 2006/42/EC and are divided into a text and illustrated section. They contain important information on the product, and especially safety instructions and warnings.
Read through the instructions carefully and keep them in a safe place.
Warnings used
-
WARNING
Indicates a danger that can lead to death or serious injuries. -
ATTENTION
Indicates a danger that can lead to damage or destruction of the product.
Warning symbols used
Safety instructions
Intended use
This garage door is designed and intended for private use only. Continuous
operation is not permitted.
General safety instructions
- Only specialists in accordance with EN 12635 may fit, service, repair and disassemble the product. Adhere to the national regulations.
- In the event of a door failure, sluggish operation or other malfunctions, immediately commission a specialist for the inspection or repair work.
- Check that the door is in perfect mechanical working order before initial start-up. The door must be easy to operate manually (EN 12604).
- EN 13241 specifies the application of the sectional door BR 40.
- Pay attention to possible dangers in accordance with EN 12604 and EN 12453 when fitting the door.
- Safety in accordance with DIN / TS 18194 based on DIN EN 1627:2011-09
On-site changes may void the CE compliance.
RC2 reached:
• Door leaf LPU 42, LPU 67 | • Door with operator |
---|---|
• Door leaf RenoMatic | • Wicket door possible |
• Door with house number, logo and styles without glazing |
RC2 not reached:
Glazing, door handle set, recess, folding roller bracket, set Reno RZ,
adjustable bottom profile, flush-fitting panel, fixed element
Environment conditions
ATTENTION
Damage caused by temperature differences
Differences in the outside and inside temperatures may result in deflection of
the door elements and foam break (bi-metal effect). There is the risk of
damage during door operation.
- Operating conditions observed.
The door is intended for the following ambient temperatures:
Temperature: | Exterior side | -40 °C to +60 °C |
---|---|---|
Interior side | -20 °C to +60 °C | |
Relative air humidity | 20% to 90% |
Requirements of the door
Break-in-resistant component
Break-in-resistant component RC2 acc. to DIN EN 1627:2011
Requirements on the building structure
Resistance class RC2 N, RC2 (Suitable wall construction)
- A timber post with a cross-section ≥120 mm × 120 mm is suitable for connection with resistance classes RC, e.g. in the area of the door opening.
- During inspection, consider other wall fitting methods or fitting types, e.g. fitting in double-shell brickwork. For inspection, install the specimen in original wall sections or fitting situations.
- The fitting certificate confirms expert fitting in accordance with the fitting instructions of the manufacturer.
Fitting
WARNING
The danger of injury due to structural modifications
Changing or removing functional parts may impair the function of important
safety components and lead to uncontrolled door travel, resulting in the door
trapping persons or objects.
- Do not attach any additional components.
- Door with operator: Observe the instructions of the operator manufacturer.
The door opening and building floor must be completed before the door is fitted.
Observe the following during the fitting:
- Make sure that the connection to the building structure is sound.
- Check that the supplied fixing materials are suitable for the situation on-site.
- Always obtain the permission of the structural engineer before fastening the door system to support structural elements.
- To prevent corrosion, make sure that there is sufficient water run-off to the outside in the area of the bottom seal and the frame parts (see fitting data).
- To prevent corrosion, ensure sufficient drying or ventilation of the building.
- Protect the door during painting and plastering work. Splashes of mortar, cement, plaster, paint, etc. may damage the surface.
- Protect the door from caustic, aggressive substances, e.g. nitrous reactions from stones or mortar, acids, alkali solutions, de-icing salt, aggressive paints or sealants.
Please carefully follow the work steps listed in the illustrated section.
Dismantling
Dismantle the door in accordance with these fitting instructions in the
logically correct reverse order.
Hardware
Parts List
Installation Instruction
Fitting certificate according to DIN EN 1627 and DIN/TS 18194
Fitting company
- Name, address ——————-
Certifies fitting of the listed break-in-resistant components in accordance with the specifications of the fitting instructions.
- Project ————————————–
- Address ————————————–
- Company stamp ————————————–
- Date and signature ————————————–