PROMED 2020 Electric Nail File User Manual
- June 3, 2024
- promed
Table of Contents
- PROMED 2020 Electric Nail File
- Overview
- DESCRIPTION OF THE UNIT
- SAFETY INSTRUCTIONS
- INFORMATION ON THE UNIT/SCOPE OF DELIVERY/ACCESSORIES
- OPERATING THE UNIT
- SPECIAL QUALITY FEATURES
- MAINTENANCE TIPS
- WARRANTY
- CE-DIRECTIVES
- TECHNICAL SPECIFICATIONS
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
PROMED 2020 Electric Nail File
Overview
- A. Power adapter
- B. Power adapter plug
- C. Power adapter socket
- D. Rotational speed regulator/rotational direction regulator
- E. Rotational speed indicator
- F. Foot pedal LED
- G. Handpiece holder
- H. Foot pedal connection
- I. Handpiece connection
- J. Handpiece
- K. Collet chuck
- L. Clamping device
- M. Unlocking device
- N. Power plug
- O. Foot pedal on/off function (optional accessory)
DESCRIPTION OF THE UNIT
Please read the user manual thoroughly before using the appliance for the first time. Many thanks for purchasing the Promed 2020 manicure device. This device was specially designed and manufactured to ensure the quality of treatment and may be used by both qualified personnel and private individuals after reading these instructions. This device is only suitable for manicure use (e.g. cuticle care, nail care, etc.). The device is also suitable for working in the field of nail technique and nail design as well as handling all materials used in this field such as gel and acrylic. We, as the manufacturer, cannot be made liable in any way for injury or damages to people or objects that arise from failure to comply with this warning.
We wish you a lot of enjoyment with your new Promed 2020 unit. We would like to familiarize you with the unit in the following sections. Please read the user manual thoroughly before using the unit for the first time.
Note:
Please maintain a distance of 2 – 3 mm between the tip of the handpiece and
the abrasive wheel.
The rotational speed must be reduced to zero before changing the abrasive wheel. The device switches itself off in the event of non-compliance (SAFETY STOP).
Changing the abrasive wheel
- Turn the clamping device (L) to the left. It must audibly click/snap into place two (2) times. The collet opens.
- The abrasive wheel can be changed.
- Afterward, turn the clamping device (L) to the right. It must audibly click/snap into place two (2) times. The collet closes and thereby secures the abrasive wheel. Start the device again for operation.
SAFETY INSTRUCTIONS
Please pay attention to the following before first time operation:
Never place the unit in direct contact with fire, gas, oxygen or hot objects
such as hot plates.
Please observe the following during the operation:
- The handpiece may only be connected to the unit included in the delivery contents.
- Grinding heads to be used:
- Standardized dental size: 2.332 – 2.350 mm / 0.091 – 0.093 inches.
- Only use centered grinding heads with a rounded shaft end.
- The use of rusted or bent grinding heads is not permitted.
- Use the speed controller carefully.
- Mains adapter power supply: 100 VAC to 240 VAC.
- Switch the unit off before you change the grinding head.
- Take every precaution possible to ensure that the unit does not fall down or get damaged in any other way.
- If problems do arise with the handpiece, take it immediately to get it repaired.
- Do not lubricate or wash the handpiece.
- Do not switch the unit on while the chuck is opened.
- Place the test grinding head in the chuck when storing the handpiece.
- For indoor use only.
- Scrupulous supervision is required when the device is being used in the vicinity of children.
- Never extend the handpiece or foot pedal cable.
- The device may only be used with the power adapter supplied.
DANGER!
- Do not place the unit in direct contact with water or other fluids.
- Never place or use the unit in a wet or moist environment.
- Do not touch the unit with wet hands.
- Only operate the unit with the specified line voltage.
- It is not permitted to use the unit outdoors.
WARNING!
- Children must not play with the device.
- Never leave the unit unattended when children or inexperienced persons are in its vicinity.
- Only use the unit for the applications described in this manual.
- Only use attachments and accessories from the manufacturer.
- Never use the unit after the electrical lead has been damaged, when the unit has fallen down or when it has come in contact with water.
- This device can be used by children from the age of 8 years and by persons with reduced physical, sensory or mental abilities or lack of experience and knowledge if they are supervised by persons responsible for their safety or if they were instructed in detail on how to use this device so that they understand the risks associated with the device.
- Never let children play with the packaging material; there is a risk of suffocation.
- An electrical appliance is not a toy. Children do not recognize the risks that could develop when using electrical appliances. Therefore, operate and store the unit out of the reach of children.
- Do not place or use the unit on hot surfaces or near naked gas flames to ensure that the casing does not melt.
- Never let the unit come into contact with water. Use a moist cloth to clean the unit. Do not use solvents.
- Never carry or pull the unit by the power cord. Use the plug to pull the power cord out of the wall socket. Do not pull on the power cord itself.
- Do not pull the power cord over sharp edges, wedge it in between objects, hang it down or position or hang it over hot objects (e.g., hot plates) or naked flames. Protect the power cord from heat or oil.
- Only use extension cords when you have satisfied yourself beforehand so that they are not defective or damaged.
- If the power adapter or its cable is damaged, immediately have it replaced by an expert.
- Do not store the unit near a wash basin or bathtub as there is a danger that the unit may fall or be pulled into the wash basin or the bathtub.
- Children must not clean or maintain the device without supervision.
- To avoid all risks of injury, blockage, or damage to the unit, make sure that the unit does not come into contact with clothing, cords, shoelaces, bristles, wires, threads, hairs, etc. when in operation.
Note:
The AC adapter may become slightly warm. This does not indicate a malfunction.
The device can be used easily.
INFORMATION ON THE UNIT/SCOPE OF DELIVERY/ACCESSORIES
Before operating the unit for the first time, please check that all contents
have been delivered and that the line voltage is correct. The supplied power
adapter (A) is an electronic power supply unit intended for an operating
voltage of 100 VAC to 240 VAC. Should you require a different plug type for
the operation of the device, you can purchase it from Promed. To change the
plug type, press the release (M) and pull the power plug (N) from the power
supply unit (A). Take the required power plug (N) and push it back into the
power supply unit (A).
- The Promed 2020 device is outstandingly suitable for manicures with the abrasive wheels provided for this purpose, but especially for use in nail technique (nail design).
- The Promed 2020 unit uses a high-performance motor. The electronic speed control is used to smoothly set the speed of the grinding head. The unit can rotate clockwise or counterclockwise (reversible).
- The grinding head holder is able to fixate all commercial grinding heads with standardized dental size shafts of (ø 2.332 to 2.350 mm / 0.091 – 0.093 inches). Please use only high-quality grinding heads with a rounded shaft end and a maximal shaft length of 36 mm (1.26 inches) to guarantee the longest life possible for the grinding head holder!
- If you want to remove the hand piece (J), just insert it in the hand piece holder (G) provided for this purpose.
- Always make sure that the grinding head does not come in contact with other objects when you lay the handpiece down. There is a risk of the shaft becoming compressed and asymmetrical. Asymmetry in the grinding head causes damage to the handpiece!
- Grinding head bits are available at your local specialist retailer or Promed (www.promed.de).
- To ensure hygienic operation, the grinding heads must be disinfected after use.
- The handpiece may only be disinfected using disinfectant wipes.
INFORMATION ON THE UNIT/SCOPE OF DELIVERY/ACCESSORIES
- Information about suitable disinfectants and products can be obtained from Promed. For disinfection of instruments and grinding heads:
- Promed Pure ID (Product No. 330810)
- For disinfection of surfaces and devices:
- Promed Pure FD (Product No. 330815)
- For disinfection and cleaning of instruments and grinding heads:
- Promed UC-50 (Product No. 330210)
- If needed, the power adapter (Product No. 290426) and the handpiece (Product No. 201004) can be purchased from Promed separately.
Scope of delivery
- 1x Device 2020 (item 202002)
- 1x Handpiece MR20 (item 202003)
- 1x Power adapter (item 290426)
- 1x Instructions
Optional accessories
A foot pedal (Product No. 290004) with an ON/OFF function is available as an accessory.
OPERATING THE UNIT
Before you switch the unit on, you must set the rotating speed (rotary knob (D)) to zero. to
-
Insert the power adapter (A) into the power socket and the power adapter plug (B), on the back of the device, into the provided power adapter socket (C).
-
Insert the plug of the handpiece into the socket (I) on the right side of the device.
-
Select a suitable grinding head. Insert the abrasive wheel in the front of the hand piece into the abrasive wheel mount (K) and lock the collet. Never use force to remove or insert a grinding head! Grinding heads with a shaft diameter of 2.332 mm to 2.350 mm (0.091 to 0.093 inches) fit exactly into the grinding head holder without you having to use excessive force. To remove a grinding head, switch off the device with the rotation switch (D) (middle position), making sure that the rotation switch (D) clearly locks into place. Now remove the abrasive wheel after opening the collet.
-
Control of the rotation direction and speed:
-
Selection of the rotation direction:
You make this selection by turning the rotation switch (D) to the left or right. Counterclockwise: The abrasive wheel turns to the left.
Clockwise: The abrasive wheel turns to the right. -
Choice of rotational speed:
The speed is regulated by turning the rotation switch (D) to the left or to the right. The more you turn, the higher the rotation speed. -
Rotational speed indicator:
The rotational speed indicator (E) is on the left next to the rotational speed regulator/rotational direction regulator (D). This indicates the selected rotational speed by means of 5 LEDs. The device functions with maximum rotational speed when all LEDs light up.
-
-
Before the first use, make sure that you let the handpiece run for about 30 minutes at approx. 16.000 rpm (2 LED lights of the speed indicator (E) should flash). This is necessary to bed in the carbon brushes of the motor.
-
Use of foot pedal (optional accessory):
Set the rotational speed regulator (D) on “zero” (middle position). Connect the foot pedal (O) to the socket (H). The foot pedal LED (F) lights up yellow if the foot pedal is correctly connected. The running direction and rotational speed are set by turning the rotational speed regulator/rotational direction regulator (D). The device is now in standby mode. Turn the device on by pressing the foot pedal. The abrasive wheel starts to rotate in the direction and rotational speed you selected. You switch into the standby mode by pressing the foot pedal again.
Attention:
Never connect the foot pedal (O) to the station or remove this from the
station while an abrasive wheel is turning in the hand piece. The device
switches itself off in the event of non-compliance (SAFETY STOP). The
rotational speed regulator (D) must absolutely be set at “zero” (middle
position) to plug in or remove the foot pedal.
Note:
Only Promed foot pedals can be used.
Note:
A different running noise between clockwise and counter-clockwise rotation is
normal and caused by bedding in of the carbon brushes or by running in of
bearings.
In case of malfunction:
- Check that the power supply is correct.
- Check whether the handpiece is connected correctly to the unit.
- Check whether the safety stop device has reacted by setting the device at zero (middle position) with the rotational speed regulator/rotational direction regulator (D) in order to start the device again.
- Check whether the foot pedal is properly connected to the device (foot pedal LED (F) lights up yellow).
- Please contact your service point if the problems are not yet solved.
SPECIAL QUALITY FEATURES
ASC (Automatic Speed Control) = digital load compensation control:
The electronic system registers the pressure on the abrasive wheel when
grinding and compensates the loss of rotational speed. Maximum power is always
available to you.
All-in-One control knob:
Select running direction and rotational speed with one regulator at the same
time through the simplest operation.
Safety Stop:
If the device develops excessive speed and pressure during grinding, the
electronics will respond by switching off the device. In this case, you must
set the rotation switch (D) of the device to zero (middle position) and start
the device again.
MAINTENANCE TIPS
To ensure that the safety, reliability, and performance of the unit are not adversely affected, enhancements, readjustments, alterations, or repairs are not permitted aside from those performed by Promed authorized persons.
- Keep the inner parts of the handpiece as free as possible from dust and grinding residue.
- Remove dirt from the outer surface of the handpiece with a cloth moistened with alcohol. Prevent moisture from entering the unit.
- Only use grinding heads with a dental standard size of 2.332 – 2.350 mm (0.091 – 0.093 inches) and avoid using rusted or damaged grinding heads. Their false usage may lead to excessive wear and tear in the ball bearings. Adhere to the safe speed and the safety measures stipulated by the manufacturer.
- Do not expose the handpiece to strong knocks as this may damage the ball bearings. If the handpiece should fall down, check whether the grinding head is bent. Pay closer attention to noise and/or heat generation. Send the handpiece immediately in for repair should it be damaged.
- Before cleaning the unit, make sure that it is turned off and disconnected from the electricity.
- Do not use any aggressive substances such as scouring agents or other detergents as they may corrode the surface.
- Never immerse the device in a liquid and keep it away from liquids containing solvent or acetone.
SERVICE
Your customers will definitely be expecting you to deliver a professional
result. This is only possible with an appliance that is neither defective nor
damaged. Therefore, take advantage of our service and have your appliance
regularly examined by our specialists. Send in your appliance to Customer
Service every 12 months at the latest. We can give you an estimate of the cost
(total cost: 19.00 € net) that will be accounted for during the service of the
device (total cost: 29.00 € net + material costs).
DISPOSAL
Power tools, accessories, and packaging should be recycled in an
environmentally suitable manner.
Only for EU countries:
Do not dispose of power tools with domestic waste! In accordance with the
European Directive 2012/19/EU on waste electrical and electronic equipment and
its implementation into national law, nonfunctioning power tools must be
collected separately and recycled in an environmentally suitable manner.
This symbol indicates that disposal of this product in domestic waste is not permitted within the EU. Waste devices contain valuable recyclable material that should be recycled. Recycling also prevents uncontrolled waste disposal from damaging the environment and human health. Therefore, please dispose of all waste devices in the appropriate collection systems or send the device to the place where you bought the device for disposal. They will then recycle the device.
WARRANTY
This product was produced with the utmost care and was thoroughly tested before it left the factory. Therefore, we provide a warranty period of 24 months from the date of purchase for this product. Promed products conform to their description and the relevant specifications; it is your responsibility to ensure that the product which you have purchased is designed for your intended use.
- In the event of material defects and/or manufacturing errors that appear during proper use and are detected during the warranty period, we will replace all defective parts of the product free of charge within the warranty period, including the labor costs for warranty repairs.
- The warranty does not cover:
- Normal wear on the product
- Defects that were caused during the transportation or storage of the product
- Defects or damage which were caused through improper use or inadequate maintenance
- Damage resulting from disregarding the notes in the operating manual
- Damage resulting from modifications to the product which were not carried out by Promed.
- Damage caused by sharp objects or as a result of torsion, compression, being dropped, an abnormal impact, or other actions which are beyond Promed’s reasonable control.
- Parts that are subject to wear (e.g. moving parts such as ball bearings, etc., fasteners, etc.) are generally excluded from the warranty.
- A claim under the warranty is not enforceable if:
- the product is not sent back in its original packaging or in adequately secure packaging;
- it has been modified or repaired by a person or company other than Promed or one of Promed’s authorised dealers;
- the product has been repaired using parts that are not approved by Promed;
- the serial number / LOT number of the product has been removed, deleted, changed, or made illegible.
- For reasons of hygiene, any products which have been exposed to direct contact with a body or with bodily fluids (e.g. blood) must be packaged in an additional plastic bag before they are sent back. In this case, a specific note of this situation must be made in the package or in the accompanying documents.
- For components or products which are replaced during the warranty period, a warranty is only provided for the remainder of the original warranty period; provided that the product or part replacement was carried out by Promed or one of Promed’s authorised dealers.
- The warranty period begins on the day of purchase. Claims under the warranty must be established within the warranty period. Complaints arising after the expiry of the warranty period cannot be considered.
- Under these warranty conditions, the warranty shall only apply if the date of purchase can be proven by means of a sales receipt or similar.
- We reserve the right to make technical and visual changes as well as changes to the features.
- This warranty is only valid and enforceable in the country in which it was purchased by the original buyer, provided that it was Promed’s intention that the product should be offered for sale in this country. This warranty is also enforceable in any country within the European Economic Area in which Promed has an authorized importer or sales partner. Depending on each country, specific and differing warranties and guarantees may be applicable owing to the particularly applicable legislation. These legal provisions are neither excluded nor limited by these warranty conditions. To the extent permissible under national law, the warranty period shall not be extended, renewed, or otherwise affected by any subsequent resale, repair, or replacement of the product.
- The provisions of the UN Convention on Contracts for the International Sale of Goods shall not apply.
- Our warranty conditions do not affect the seller’s legal warranty obligation.
- To the fullest extent possible under the applicable mandatory legislation, these warranty conditions constitute your sole and exclusive legal remedy and shall apply in place of any other express or implied warranty conditions. Promed is not liable for any unusual, incidental, punitive, or consequential damages including, but not limited to loss of profits, loss of use, loss of revenue, costs of replacement equipment or facilities, third-party insurance claims, and damage to property which are the result of the purchase or use of the product or occur owing to a breach of warranty, a breach of contract, negligence, product defects or any other legal or statutory circumstances, even though Promed was aware of the possibility of such damages. Promed is not liable for any delay in warranty claims.
- Promed cannot be held liable for any possible translation errors.
- The following information is vital for problem-free processing:
- Original sales slip/receipt or dealer´s stamp with the date of purchase
- Defect detected
- Unit name/type
EXPLANATION FOR THE SYMBOLS
- Symbol for protection class II appliances
- Symbol for Class III appliances
- Symbol for WARNING! Indicates sections of the user manual that are relevant for safety!
- Pay attention to the symbol for the user manual!
CE-DIRECTIVES
It is designed for operation with a line voltage of 100 – 240 VAC, 50/60 Hz.
CE according to EC Directive 2006/42/EC in accordance with the EC Directive
- 2014/35/EU,
- 87/308/EEC,
- 2014/30/EU,
- 2011/65/EU,
- 1907/2006/EC,
- 2009/125/EC,
- 2005/69/EC,
- 2001/95/EC
- and 93/68/EEC.
Furthermore, the device fulfills the requirements of the standards:
- EN 60335-1:2012
- EN 60335-2-23:2003
- +A1:2008 +A11:2010
- +AC:2012
- IEC 60335-1:2010
- IEC I60335-2-23:2003
- +Cor. 1:2004 +Cor. 2:2008
- +A1:2008 +Cor. 3:2007
- +A2:2012
- EN 55014-1:2006
- +A1:2009 +A2:2011
- EN 55014-2:1997
- +A1:2001 +A2:2008
- EN 61000-3-2:2005
- +A1:2009 +A2:2009
- EN 61000-3-3:2008
- DIN EN ISO 12100:2010
- DIN EN 60745-1:2010
- EN 62233:2008
Adapter:
- EN 60950-1:2001
- IEC 60950-1:2001+A11:2004
- with CB-report
- UL 60950-1:2003
- CAN/CSA-C22.2
- Nr.60950-1:2003
- AS/NZS 60950-1:2003
TECHNICAL SPECIFICATIONS
-
Appliance type:
Care devise for a manicure -
Speed:
Continually adjustable up to 30 000 rpm -
Direction of rotation:
Clockwise and counterclockwise -
Torque:
34 mNm -
Power supply:
100 – 240 VAC, 50 / 60 Hz, 800 mA sec. 24 VDC, 1 A -
Energy consumption with zero loading:
0.27 W -
Average efficiency when operating:
83,59 % Level VI -
Handpiece:
Strong, vibration-free stainless steel hand piece, weight 160 g Plugs are available for the UK, Australia, USA, and other countries
TRANSPORT/STORAGE/OPERATING CONDITIONS
Only transport in the original packaging.
Transport and storage temperature:
+5° C – +50° C (+41° F to +122° F)
Operating temperature:
+10° C – +40° C (+50° F to +104° F)
Relative humidity:
30 % to 75 % non-condensing
Atmospheric pressure:
700 to 1 060 hPa
An abrupt change in temperature is to be avoided as condensation may arise in the unit. Only operate the unit after the temperature has been equalized.
Promed GmbH · Lindenweg 11· D-82490 Farchant · Tel: +49 (0)8821/9621-0 Fax: +49 (0)8821/9621-21· info@promed.de · www.promed.de.
Promed GmbH
- Lindenweg 11 D-82490 Farchant
- Tel: +49 (0)8821/9621-0
- Fax: +49 (0)8821/9621-21
- info@promed.de.
- www.promed.de.
WARRANTY CARD
- Device classification
- Care device for manicures
- Serial Number
- Name/address of the customer
- Purchase date
- Dealers stamp/signature
Important:
In a warranty case, please return the fully completed warranty card, and if
required enclose the proof of purchase (receipt) to the device.
Kaitstud/Secured by https://mereneid.eu/.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>