iskydance PBL-60-12 Constant Voltage LED Driver Owner’s Manual
- June 15, 2024
- iskydance
Table of Contents
Constant Voltage LED Driver
Model No.: PBL-60-12, PBL-60-24
Features
- 100-240VAC Input
- 1 channel constant voltage output, Max. total output power 60W
- Ultra-thin design, light weight and high ef
- Over-load / Short circuit protection
- Suitable for indoor LED lighting application
- 5 Year, 50,000hr warranty
Applications
- Suitable for cabinet LED strip.
Technical Parameters
Model | PBL-60-12 | PBL-60-24 |
---|---|---|
Output | Output Voltage | 12VDC |
Output Current | Max. 5.0A | Max. 2.5A |
Output Power | Max. 60W | |
Startup time | 1S/230VAC,2S/115VAC | |
Dimming Range | 0~100% | |
Ripple & Noise | 600mVp-p | |
Input | Input Voltage Range | 100~240VAC |
Frequency Range | 50/60Hz | |
Efficiency | 88% | |
Alternating Current | 1.0A/100VAC, 0.5A/230VAC | |
Power Factor | 0.5 | |
No Load Power | 0.3W | |
Inrush Current | Cold start 38A | |
Anti Surge | L-N:1KV | |
Leakage Current | <0.75mA | |
Protection | Over Load | Shut down the output Voltage, when the |
load>=110%~14,0%, auto recovers.
Short Circuit| Shut down the output Voltage, auto recovers
Environment| Woking Temperature| -20℃~45℃
T-case Max| 75℃
Working Humidity| 20%~90%RH, non-condensing
Storage Temperature/Humidity| -40℃~80℃, 10%~95%RH
Temperature Coefficient| ±0.03%/℃ (0-50%)
Vibration Resistance| 10-500Hz, 2G, 6min/cycle, X,Y,Z axes/2min
IP Rating| IP20
Safety&EMC| Security Specifications| IEC/EN61347-1, IEC/EN61347-2-13,
GB19510.14
Withstand Voltage| I/P-O/P: 3750VAC
Insulation Resistance| I/P-O/P: 100MΩ/500VDC/25℃/70%RH
EMC Emission| EN61000-3-2 Class C, IEC61000-3-3
EMC Immunity| EN61000-4-2.3.4.5.6.8.11, EN61547
Certications| CE
Others| Net weight| 150g
Gross weight| 170g
Size| 164x55x18mm
NOTE| All parameters NOT specially mentioned are measured at 230VAC input,
rate current and 25 ℃ of ambient temperature.
Mechanical Structures and Installations
Wiring Diagram
- Without dimming
- With dimming
Output Load VS Temperature
Static characteristic
Installation precautions
Please do not stack the products.
The distance between two products should be ≥0.5m, so as not to affect heat
dissipation and lifespan of the products.
Packing List