AK-CS-02

Reading the Instructions carefully before using

In order to prevent improper use causing accident, please be sure to follow the operation rules.

The signs and words indication herein aims at operating the equipment by user in a safe and correct way to avoid any accident or consequence caused by wrong use method. Please pay attention to the words “Danger” and “Notice”.

Warning Icon Warning

  • Cerebral hemorrhage patient is forbidden to use in unstable period. Sequelae patient uses it under doctor’s supervision.
  • Woman during menstrual period must be cautious to use.
  • Pregnant woman is forbidden to use.
  • Periost may be allergic to ultrasound wave.
  • People who implants cardiac pacemaker or has bleeding tendency is forbidden to use.
  • Ultrasound probe is prohibited to use on brain tissue directly.
  • Intracranial hypertension patient is forbidden to use.
  • Purulent patient is forbidden to use.
  • Cancer patient or severe cerebral edema is forbidden to use.

Warning Icon Warning

  1. Open frame is prohibited when the ultrasound equipment works.
  2. Do not use the equipment near inflammable gas.
  3. Do not disassemble the equipment arbitrarily.

Warning Icon Attention

  1. People implanted electronic instruments (such as cardiac pacemaker) must obey doctor’s advice.
  2. Do not use the ultrasound equipment in humid environment.
  3. No need to disinfect and sterilize the ultrasound equipment.
  4. Check the electric wire insulation regularly. Change the wire if not insulated.
  5. The user shall do a health check and make a therapy plan to prevent danger happened in using the ultrasound equipment.
  6. It is normal when the user feel a slight acid, swelling and hot.
  7. The user must stop treatment or reduce the output intensity of the ultrasound if he/she cannot endure the stimulation. The sensation handicapped is prohibited to use ultrasound treatment.
  8. Manufacturer is responsible to safety inspection and repair.
  9. It is better to put instructions together with the ultrasound equipment.
  10. The operation of the equipment must strictly follow the manual.
  11. Make sure the equipment electricity working environment safe and electrical grounding.
  12. Sterilize the ultrasound probe with alcohol.
  • People who is sensitive to ultrasound can adjust the intensity of ultrasound from lower to higher level to fit for the body gradually.
  • The ultrasound probe is forbidden to use on brain, heart, eyes, gonad (testicle, ovary) and so on.
  • Cover gel cream on ultrasound probe when it works. Water cannot be couple agent replacement.
  • There’s no repair tools and spare parts for customer. Do not disassemble by yourself or unprofessional people when failure happens. Contact the seller / manufacturer for after sale service.

Function

Ultrasound treatment on human body belongs to physiotherapy massage, which has 50 years history. It is known as one of the greatest technologies for the obvious effects. The ultrasound equipment is a high-tech product with three effects of ultrasound. It is a mature technology, non-toxic, nonradiative and without side effects.

Principles and Range of Uses

High Frequency mechanical effects

  • Ultrasonic vibration can cause cell movement, thus having the effects of massage and analgesia.
  • Promote metabolism, enhance blood and lymph circulation, improve tissue nutrition, change the rate of protein synthesis, increase the regeneration function, etc.
  • Making cytoplasm flow, cytoplasmic granules oscillation, rotation and friction.It can stimulate the process of cell semipermeable membrane diffusion , causing the rate of diffusion and membrane permeability changes.

Thermal Effects

  • Increase the number of open blood capillary, enhance blood circulation, strengthen the metabolism.
  • Improve muscle and connective tissue tension, relieve cramps pain.
  • Improve partial tissue nutrition, enhance enzyme activity.Promote the establishment of collateral circulation.
  • It is good for absorbing congestion.

Permeation Effects

  • Improving the membrane permeation, the medicine is more accessible to get in bacteria.
  • Make mast cell degranulation, intracellular calcium levels increase, increased vascular permeability, angiogenesis and collagen tension increases, etc.
  • Ultrasound can make oxidase and dehydrogenase enzyme inactivation, and promote the effect of invertase.
  • Ultrasound can affect blood flow, promote angiogenesis, collagen and scar maturation dissolution.

Benefit

Suitable for the person who gets stroke with moving disable and soft tissue contusion.

FIG 1 Benefit

Introduction of the operation face.

FIG 2 Introduction of the operation face

  1. Switch on the equipment by pressing the button on the back, the indication light will be on.
  2. Choose intensity and work time by pressing intensity and timer button.
  3. Cover gel cream on treatment part of the body and on the ultrasound probe.
  4. Switch off the button and clean the ultrasound probe after treatment finish.

FIG 3 Introduction of the operation face

Function description

The operating frequency is 1MHz and the surface temperature of ultrasonic transducer is 45℃ , the detailed functional description is as follows:

FIG 4 Function description

The timing setting of the ultrasonic equipment is as below:

FIG 5 Function description

The operation step is as follows:

  1. Connect the power adapter connector, the device is powered on, the screen default display low intensity, time 10 minutes, press the time button to set the countdown, the time value increases, the maximum setting time of 30 minutes, can be set to cycle. Set the timing time after the press start / pause button, the device is working, the time indicator flashes.
  2. After the end of the countdown,the digital tube shows the time value set before, the buzzer continuously “ding dong” for 5 times.Time and intensity restore to the last set time value.
  3. During the operation, if there is no ultrasonic probe connected with the main unit, the buzzer alarm will bell ringing.
  4. If the circuit in the working process is over flow, the device will automatically stop the output intensity, and the intensity display area of the 9 LED lights flash.
  5. When the temperature of ultrasonic transducer surface reaches the maximum temperature, the transducer will stop the output, and it will not work until the temperature reduce.

Common Failures and Trouble Shooting

FIG 6 Common Failures and Trouble Shooting

Ask and Answer

  1. How much gel cream should be use during treatment?
    What effect that gel cream have?
    Answer: Generally it is better to cover 2mm on probe. Using gel cream is for insulate air between probe and skin. Because ultrasound recession is very soon in the air. If not using gel cream or amount is not enough, it will damage the ultrasonic probe and reduced physical effects.

  2. How to use probe and in what method is better?
    Answer: using the ultrasonic probe with skin moving slowly, starting with low gear. Then adjust gear accordingly till adapt.

  3. What posture is good during use?
    Relax the treatment part of body and at a comfortable status.

  4. Does the probe need to press skin tightly? How to improve use effect? It is not good if press tightly. Only need touch the skin gently with probe and fill with gel cream. If you want to improve the treatment effect, you should consult it with doctor and making a set of schemes. Operate it according strictly.

  5. Why the feeling of back treatment is not obvious?
    Because the treatment area is too large, after each movement the gathering effect is not good. when the treatment part of body is more than 5cm, should be treated separately.

  6. Is it normal to feel a bit of acmesthesia, aching pain, numbness and disten sion when using ultrasound equipment? How to solve it?
    It is normal reaction of above feelings which expresses the effect of ultrasound waves. No need to do special treatment at the tolerable range. With the depth of treatment, the feeling will be weakened, which means your fitness enhanced. If you cannot endure it, please get the gear lower or stop using