MAXPEEDINGRODS MXR3500 Digital Inverter Generator User Manual
- June 14, 2024
- MAXPEEDINGRODS
Table of Contents
MXR3500 Digital Inverter Generator
User Manual
MXR3500 Digital Inverter Generator
DISCLAIMERS:
All information, illustrations and specifications in this manual are based on
the latest information available at the time of publishing. The illustrations
used in this manual are intended as representative reference views only.
Moreover, because of our continuous product improvement policy, we may modify
information, illustrations and/or specifications to explain and/or exemplify a
product, service or maintenance improvement. We reserve the right to make any
change at any time without notice. Some images may vary depending upon which
model is shown.
ALL RIGHTS RESERVED:
No part of this publication may be reproduced or used in any form by any means
graphic, electronic or mechanical, including photocopying, recording, taping
or information storage and retrieval systems – without the written permission
of Chongqing Guoyu Technology Co., Ltd
DANGER
This manual contains important instructions for operating this inverter
generator. For your safety and the safety of others, be sure to read this
manual thoroughly before operating the generator. Failure to properly follow
all instructions and precautions can cause you and others to be seriously hurt
or killed.
TECHNICAL SPECIFICATIONS
Model Number | MXR3500 |
---|---|
Running Watts | 13000 |
Peake Watts | 13300 |
Fuel Tank Size (1) | 4 |
Rated Speed (PM) | 4850 |
Ignition Type” | CDI |
Spark Plug | A5RTC |
Engine Disp(cc) | 145 |
StrokeX Bore | 64X45 |
Oil Capacity (L) | 0.45 |
oilType | 10W30 |
LIMITED WARRANTY
-
DURATION: Maxpeedingrods warrants all the inverter generators against defects in workmanship under normal use for a period of 2 years from the date of retail purchase by the original end-user purchaser (“Warranty Period”), and free lifetime technical support and customer service.If a product is used for business,commercial, or industrial applications, the warranty period will be limited to ninety (90) days from the date of purchase.
-
WHO GIVES THIS WARRANTY (WARRANTOR): Chongqing Guoyu Technology Co., Ltd
-
WHO RECEIVES THIS WARRANTY(PURCHASER): The original purchaser ( other than for purposes of resale) of the MAXPEEDINGRODS inverter.
-
WHAT PRODUCTS ARE COVERED BY THIS WARRANTY: Any portable generator supplied or manufactured by Warrantor.
-
WHAT IS COVERED UNDER THIS WARRANTY: Substantial defects on material and workmanship which occur within the duration of the warranty period.
-
WHAT IS NOT COVERED UNDER THIS WARRANTY:
A. Transportation changes for sending the product to Warrantor or its authorized service representative for warranty service, or for shipping repaired or replacement products back to the customer; these charges must be borne by the customer.
B. Damages caused by abuse, accident, shipping, misuse, overloading, modification, and the effects of corrosion, erosion and normal wear and tear.
C. Warranty is voided if the customer fails to install, maintain and operate the product in accordance with the instructions and recommendations set forth in the owner’s manual(s), or if the product is used as rental equipment.
D. Pre-delivery service, i.e. assembly, oil or lubricants, and adjustment.
E. Items or service that are normally required to maintain the product, i.e. lubricants and filters.
F. Warrantor will not pay for repairs or adjustments to the product, or for any costs or labour, performed without Warrantor’s prior authorization.
EXCLUSIONS AND LIMITATIONS: Warrantor makes no other warranty of any kind, express or implied. Implied warranties, including warranties of merchantability and of fitness for a particular purpose, are hereby disclaimed. This warranty service described above is the exclusive remedy under this warranty; liability for incidental and consequential damages is excluded to the extent permitted by law. -
RESPONSIBILITIES OF PURCHASER UNDER THIS WARRANTY:
A. The purchaser must provide dated proof of purchase and must notify Warrantor within the warranty period.
B. Deliver or ship the serviced generator or component to the nearest Warrantor’s authorized service representative. Freight costs, if any, must be borne by the purchaser.
SAFETY
SAFETY DEFINITIONS
The words DANGER, WARNING, CAUTION and
NOTICE are used throughout this manual to highlight important information. Be
certain that the meanings of these alerts are known to all who work on or near
the equipment. This safety alert symbol appears with most safety statements.
It means attention, become alert, your safety is involved! Please read and
abide by the message that follows the safety alerts symbol.
DANGER
Indicates a hazardous situation which, if not avoided, will result in death
or serious injury.
WARNING
Indicates a hazardous situation which, if not avoided, could result in death
or serious injury.
CAUTION
Indicates a hazardous situation which, if not avoided, could result in minor
or moderate injury.
NOTICE
Indicates a situation which can cause damage to the generator, personal
property and/or the environment, or cause the equipment to operate improperly.
DANGER
Connection of the product to a building’s electrical system is not
applicable.
NOTE: Indicates a procedure, practice or condition that should be
followed in order for the generator to function in the manner intended.
SAFETY SYMBOL DEFINITIONS
Symbol | Description |
---|---|
Safety Alert Symbol | |
Asphyxiation Hazard | |
Burn Hazard | |
Burst/Pressure Hazard | |
Don’t leave tools in the area | |
Electrical Shock Hazard | |
Explosion Hazard | |
Fire Hazard | |
Lifting Hazard | |
Pinch-Point Hazard | |
Read Manufacturer’s Instructions | |
Read Safety Messages Before Proceeding | |
Wear Personal Protective Equipment (PPE) |
GENERAL SAFETY RULES
DANGER
Never use the inverter in a location that is wet or damp. Never expose the
inverter to rain, snow, water spray or standing water while in use. Protect
the inverter from all hazardous weather conditions. Moisture or ice con cause
a short circuit or other malfunction in the electrical circuit.
Never operate the inverter in an enclosed area. Engine exhaust contains carbon
monoxide. Only operate the inverter outside and away from windows, doors and
vents.
WARNING
Voltage produced by the inverter could result in death or serious injury.
- Never operate the inverter in rain or a flood plain unless proper precautions are token to avoid being subject to rain or a flood.
- Never use worn or damaged extension cords.
- Always have a licensed electrician connect the inverter to the utility circuit.
- Never touch an operating inverter if the inverter is wet or if you hove wet hands.
- Never operate the inverter in highly conductive areas such as around metal decking or steel works.
- Always use grounded extension cords. Always use three-wire or double-insulated power tools.
- Never touch live terminals or bare wires while the inverter is operating.
- Be sure the inverter is properly grounded before operating.
WARNING
Gasoline and gasoline vapors are extremely flammable and explosive under
certain conditions.
- Always refuel the generator outdoors, in a well-ventilated area.
- Never remove the fuel cap with the engine running.
- Never refuel the inverter while the engine is running. Always turn engine off and allow the generator to cool before refueling.
- Only fill fuel tonk with gasoline.
- Keep sparks, open flames or other form of ignition (such as match, cigarette, static electric source) away when refueling.
- Never overfill the fuel tank. Leave room for fuel to expand. Overfilling the fuel tank can result in a sudden overflow of gasoline and result in spilled gasoline coming in contact with HOT surfaces.
- Spilled fuel can ignite. If fuel is spilled on the inverter, wipe up any spills immediately. Dispose of rag properly. Allow area of spilled fuel to dry before operating the inverter.
- Wear eye protection while refueling.
- Never use gasoline as a cleaning agent.
- Store any containers containing gasoline in a well-ventilated area, away from any combustibles or source of ignition.
- Check for fuel leaks ofter refueling. Never operate the engine if a fuel leak is discovered.
WARNING
Never operate the inverter if powered items overheat, electrical output drops,
there is sparking, flames or smoke coming from the inverter, or if the
receptacles are damaged.
Never use the inverter to power medical support equipment.
Always remove any tools or other service equipment used during maintenance
from the inverter before operating.
NOTICE
Never modify the inverter. Never operate the inverter if it vibrates at
high levels, if engine speed changes greatly or if the engine misfires often.
Always disconnect tools or appliances from the Inverter before starting.
SAFETY LABELS AND DECALS MXR3500 Warning
Operation of this equipment may create sparks that can start fires around dry
vegetation.
Do not use the generator in a direction that the exhaust emission to the
occupied structures, the sparks in the exhaust emission may start fires.
Warning
A hot exhaust system can cause serious burns. Avoid contact if the engine
has been running.
A hot exhaust system can cause serious bums, avoid contact if the engine has
been running.
Warning
Read the operator’s instruction manual; The new engine inside has no engine
oil,before starting the generating set, be sure to fill the crankcase with
specified engine oil.
Check that there is not any fuel spilling or fuel leakage.Not to refuel
when operating.
Exhaust gas is poisonous; Do not operate in an unventilated area.
[Carbon monoxide (CO) danger].
**** Hot exhaust can burn you. Stay away if engine has been running.
EC 145cc EURO(V) SRA1/PV – 1356
UNPACKING
CAUTION
Aways have assistance when lifting the inverter. The inverter is heavy;
lifting it could cause bodily harm.
**** Avoid cutting on or near staples to prevent personal injury.
Tools required – box cutter or similar device.
- Carefully cut the packing tape on top of the carton
- Remove socket wrench, funnel and save for later.
- Carefully cut two sides of the carton to remove the inverter
WHAT Cosmas IN THE BOX Spark Plug Socket Wrench (1) Owner Manual (1) Paralleling Cord (1) Funnel (1) Cigarette Lighter Plug (1) Eu Plug (1) Generator Dust Cover (1) Screwdriver (1)
FEATURES
BASIC INVERTER FEATURES MXR350O
- Fuel Cap and vent: Open the vent to run the engine and close the vent when the engine is off.
- Control Panel: Contains the reset breaker, outlets and warning lights.
- Spark Plug Access Cover: Remove the cover to service the spark plug.
- Recoil Handle: Pull to start the engine
- Engine Control switch: Sets the choke, turns the fuel on and off
- Engine service Panel: Remove the panel to access the engine for maintenance
- Muffler and Spark Arrestor: Avoid contact until the engine is cooled down. The spark arrestor prevents sparks from exiting the muffler. It must be removed for servicing.
- Engine Cooling Vents: Helps move airflow in unit to regulate engine temperatures.
- Recoil Handle Protective Cover: Prevents pull cord wire from damaging inverter body.
CONTROL PANEL FEATURES MXR350O
- 230-volt, 6-amp EU Outlet: The outlet is capable of carrying a maximum of 16 0mps
- DC Cigarette lighter outlet: 12V DC 8.3A.
- AC#Reset: If the inverter is overloaded, the reset breaker will trip. The engine will continue to run, but there will be no output from the inverter. Unplug the devices and reduce the load. Push in the reset breaker to reset it
- DC Breaker; If the inverter is overloaded, the reset breaker will trip to block current.
- Efficiency Mode Switch: when turned to the ON position, the engine will sense the load needed and run at a slower RPM to save fuel
- Low Oil LED: Indicates low oil level.
- Overload LED: Indicates that the inverter is overloaded.
- Output Ready LED: Indicates the inverter is ready to be used.
- Engine Control switch: Turn position to CHOKE to start the engine, and turn to RUN position once the engine is running. Switch to OFF to stop inverter.
- Ground Terminal: The ground terminal is used to externally ground the inverter us8
- Duplex: 5v DC that come in l amp and 21 amps
- Parallel Connectors: increase AC power output, the connector sockets are used to connect the two same type generator with special paralleling cords. The connector sockets are only used to the communication between the inverters, hey cannot be used for AC power output. The special paralleling cords shall be purchase separately, and they shall be approved by certification body
EFORE STARTING THE INVERTER
BEFORE STARTING THE INVERTER, REVIEW SAFETY SECTION STARTING ON PAGE 5.
Location Selection – Before starting the inverter, avoid exhaust and location
hazards by verifying:
- You have selected a location to operate the inverter that is outdoors and well ventilated.
- You have selected a location with a level and solid surface on which to place the inverter.
- You have selected a location that is at least 6 feet (1.8 m) away from any building, other equipment or combustible material.
- If the inverter is located close to a building, make sure it is not located near any windows, doors and/ or vents.
DANGER
Using a generator indoors
CAN KILL YOU IN MINUTES.
Generator exhaust contains carbon monoxide This is a poison you cannot see or
smell. NEVER use inside a home or garage, EVEN IF doors and windows are open.
Only use OUTSIDE and far away from windows, doors, and vents.
Avoid other generator hazards. READ MANUAL BEFORE USE.
WARNING
Always operate the inverter on a level surface. Placing the inverter on non
level surfaces can cause the inverter to tip over, causing fuel and oil to
spill. Spilled fuel can ignite if it comes in contact with an ignition source
such as a very hot surface.
NOTICE
Only operate the inverter on a solid, level surface Operating the inverter
on a surface with loose material such as sand or grass clippings can cause
debris to be ingested by the inverter that could:
- Block cooling vents
- Block air intake system
Weather – Never operate your inverter outdoors during rain, snow or any
combination of weather conditions that could lead to moisture collecting on,
in or around the generator.
Dry Surface – Always operate the inverter on a dry surface free of any
moisture.
No Connected Loads – Make sure the inverter has no connected loads before
starting it. To ensure there are no connected loads, unplug any electrical
extension cords that are plugged into the control panel receptacles.
NOTICE
Starting the inverter with loads already applied to it could result in
damage to any appliance being powered off the inverter during the brief start-
up period.
Grounding the Inverters
Consult with your local municipalities for your grounding codes.
WARNING
Be sure the inverter is properly connected to earth ground before
operating.
OPERATION
POWERCORD
Using Extension Cords
MAXPEEDINGRODS Portable Power assumes no responsibility for the content within
this table. The use of this table is the responsibility of the user only. This
table is intended for reference only. The results produced by using this table
are not guaranteed to be correct or applicable in all situations as the type
and construction of cords are highly variable. Always check with local
regulations and a licensed electrician prior to installing or connecting an
electrical appliance.
Extension Cord Wire Gauge Size INVERTER
PARALLELING OPERATION
DANGER
Never connect the paralleling cord to the inverters with the inverters
running. The inverters must not be running and both the paralleling cord
switches must be off when connecting the cords.
WARNING
Do not attempt to parallel the AXPEEDINGRODS inverter with any other
manufacturers’ inverters. Do not use the paralleling cord for any application
other than inverter paralleling. Do not use this cord on other manufacturers’
inverters.
INVERTER PARALLELING OPERATION
- Using only the MAXPEEDINGRODS paralleling cord with both cord switches set to OFF (0), connect one male plug to one inverter and connect the remaining plug into the other inverter. Either of the receptacles on the inverters can be used.
- Start one of the inverters and wait until the output ready light is on.
- Turn both cord switches to ON (1).
- Start the remaining inverter; wait until the output ready light is on before connecting the load.
- When power is present, a light will illuminate in the three-prong plug that is plugged into the inverter.
- To stop the inverters, unplug all connected loads, turn both cord switches to OFF (0) and unplug the cord on each inverter.
- If during operation the inverters’ output is stopped due to overloading, reduce the connected load by unplugging appliances, and then push the reset button and restart the inverter When the ready light is on, the load can be reconnected.
INITIAL OIL FILL
BEFORE ADDING ENGINE OIL, REVIEW SAFETY SECTION STARTING ON PAGE 5.
NOTICE
Engine oil must be added when the inverter is on a flat, level surface, or an
inaccurate reading may result. Do not overfill. f the engine is overfilled
with oil, it can cause serious engine damage
- Loosen the screw and remove the engine oil fill/ drain plug service panel to access the oil fill/ drain plug (see Figure l)
- Clean the area around the oil fii/drain plug and remove plug (See Figure 2)
- Using the funnel and oil, pour the entire bottle of oil into the engine (see Figure 3).
- Do not overfill, if oil level is too high, oil will drain out through the fill plug. See correct oil level in Figure 4.
ADDING/CHECKING ENGINE FLUIDS AND FUEL
BEFORE ADDING/CHECKING ENGINE FLUIDS AND FUEL, REVIEW SAFETY SECTION STARTING
ON PAGE 5.
DANGER
Filling the fuel tank with gasoline while the inverter is running can cause
gasoline to leak and come in contact with hot surfaces that can ignite the
gasoline.
Before starting the inverter, always check the level of:
- Engine oil
- Gasoline in the fuel tonk
Once the inverter is started and the engine gets warm, it is not safe to add
gasoline to the fuel tank or engine oil to the engine while the engine is
running or the engine and muffler are hot.
CHECKING AND/ OR ADDING ENGINE OIL
WARNING
Internal pressure con build in the engine crankcase while the engine is
running. Removing the oil fill plug/ dipstick while the engine is hot can
cause extremely hot oil to spray out of the crankcase and can severely burn
skin. Allow engine oil to cool for several minutes before removing the oil
fill plug/dipstick.
The unit as shipped does not contain oil in the engine. You must add engine
oil before starting the inverter for the first time. See Initial Oil Fill on
page 12 for instructions on checking engine oil level and the procedure for
adding engine oil.
NOTICE
The engine does not contain engine oil as shipped. Attempting to start the
engine without adding engine oil will permanently damage internal engine
components.
The engine is equipped with a low oil shutdown switch. If the oil level
becomes low, the engine may shut down and not start until the oil is filled to
the proper level.
The engine is equipped with a low oil shutdown switch. If the oil level
becomes low, the engine may shut down and not start until the oil is filled to
the proper level.
ADDING GASOLINE TO THE FUEL TANK
WARNING
Never refuel the inverter while the engine is running.
Always turn the engine off and allow the inverter to cool before refueling.
CAUTION
Avoid prolonged skin contact with gasoline. Avoid prolonged breathing of
gasoline vapors.
Required Gasoline – Only use gasoline that meets the following requirements:
- Unleaded gasoline only
- Gasoline with maximum 10% ethanol added
- Gasoline with an 87 octane rating or higher
Filling the Fuel Tank – Follow the steps below to fill the fuel tank:
-
Shut off the inverter.
-
Allow the inverter to cool down so all surface areas of the muffler and engine are cool to the touch.
-
Move the inverter to a flat surface.
-
Clean area around the fuel cap.
-
Remove the fuel cap by rotating counterclockwise.
NOTICE
Do not overfill the fuel tank. Spilled fuel will damage some plastic parts. -
Slowly add gasoline into the fuel tank. Be very careful not to overfill the tank. The gasoline level should NOT be higher than the red ring (see figure 5).
-
Install the fuel cap by rotating clockwise.
STARTING THE INVERTER
BEFORE STARTING THE INVERTER, REVIEW SAFETY SECTION STARTING ON PAGE 5.
For proper starting and operation of the inverter, make sure you review the
inverter features and their descriptions starting on page 8.
Before attempting to start the inverter, verify the following:
- The engine is filled with engine oil (see Figure 4: Engine Oil Correct Level on page 12).
- The inverter is situated in a proper location (see Location Selection on page 10).
- The inverter is on a dry surface (see Weather and Dry Surface on page 10).
- All loads are disconnected from the inverter (see No Connected Loads on page 10).
- The inverter is properly grounded (see Grounding the Inverter on page 10)
DANGER
Never use the inverter in a location that is wet or damp. Never expose the
inverter to rain, snow, water spray or standing water while in use. Protect
the inverter from all hazardous weather conditions.
Moisture or ice can cause a short circuit or other malfunction in the
electrical circuit.
Never operate the inverter in an enclosed area. Engine exhaust contains carbon
monoxide. Only operate the inverter outside and away from windows, doors and
vents.
Starting MXR3500
- Check oil levels. If it is the first time starting make sure to add oil (see Initial Oil Fill on page 12).
- Turn the fuel tank vent to the ON position
- Turn the engine/fuel control switch to the CHOKE position (see Figure 6).
- Firmly grasp and pull the recoil handle slowly until you feel increased resistance. At this point, apply a rapid pull while pulling out from the inverter (see Figure 7).
- As the engine starts and stabilizes, turn the choke switch back in to the RUN position (see Figure 8).
NOTICE To start the generator in hot state, Please just turn the
engine/fuel switch to the RUN position.
STOPPING THE INVERTER Normal Operation
During normal operation, use the following steps to stop your inverter:
- Remove any connected loads from the control panel receptacles.
- Allow the inverter to run at ‘no load to reduce and stabilize engine and alternator temperatures.
- Move the engine control switch to the OFF position (see Figure 9)
During an Emergency
f there is an emergency and the inverter must be stopped quickly, move the
engine control switch to the OFF position immediately (see Figure 9).
USING EFFICIENCY MODE
The inverter is equipped with an efficiency mode switch to minimize fuel
consumption. In efficiency mode, the inverter will sense the load and adjust
the engine PM to the current load requirements. Efficiency mode should be used
only after the inverter has been wormed up to operating temperature
- To turn on the efficiency mode, press the switch to the ON position)
- If no load is present, the inverter RPM will drop down to an idle speed
- As a load is applied, the inverter will sense the load and engine RPM will increase according to the load applied.
- To run the inverter at maximum power and RPM, press the efficiency mode switch to the OFF position
RESETTING THE RESET BREAKER
The inverter will trip the breaker and automatically disconnect from the load
when the controls sense predetermined overload condition. The inverter engine
will continue to run, but there will not be any electrical output.
- Turn off all devices and unplug them from the inverter;
- Determine the wattage required from the devices being powered by the inverter Make sure the wattage required does not exceed the maximumn output of the inverter,
- Press in the reset breaker to reset it (see Figure I0)
- Plug the devices in to the inverter
- Turn on the devices as needed.
MAINTENANCE
BEFORE PERFORMING MAINTENANCE ON THE INVERTER, REVIEW THE SAFETY SECTION
STARTING ON PAGE 5, AS WELL AS THE FOLLOWING SAFETY MESSAGES.
WARNING
Avoid accidentally starting the inverter during maintenance by removing the
spark plug boot from the spark plug. For electric start inverters, also
disconnect the battery cables from the battery (disconnect the black negative
(-) cable first) and place the cables away from the battery posts to avoid
arcing.
Allow hot components to cool to he touch prior to performing any maintenance
procedure
Internal pressure can build in the engine crankcase while the engine is
running. Removing the oil fill plug dipstick while the engine is hot can cause
extremely hot oil to spray out of the crankcase and can severely burn skin.
Allow engine oil to cool for several minutes before removing the oil fill
plug/dipstick.
Always perform maintenance in a well- ventilated area. Gasoline fuel and fuel
vapors are extremely flammable and can ignite under certain conditions.
CAUTION
Avoid skin contact with engine oil or gasoline. Prolonged skin contact with
engine oil or gasoline can be harmful. Frequent and prolonged contact with
engine oil may cause skin cancer, lake protective measures and wear protective
clothing and equipment. Wash all exposed skin with soap and water
WARNING
Failure to perform periodic maintenance or not following maintenance
procedures can cause the inverter to malfunction and could result in death or
serious injury.
NOTICE
Periodic maintenance intervals vary depending on inverter operating
conditions. Operating the inverter under severe conditions, such as sustained
high-load, high-temperature, or unusually wet or dusty environments, will
require more frequent periodic maintenance The intervals listed in the
maintenance schedule should be treated only as a general guideline.
Following the maintenance schedule is important to keep the inverter in good
operating condition. The following is a summary of maintenance items by
periodic maintenance intervals
TABLE I: MAINTENANCE SCHEDULE – OWNER PERFORMED
Maintenance Item| Before Every Use| After First 20 Hours or First Month of
Use| After 50 Hours of Use or Every 6 Months| After 100 Hour of Use or Every 6
Months| After 300 Hours of Use
or Every Year
---|---|---|---|---|---
Engine Oil| Check Level| Change| Change| –| –
Cooling Features| Check/Clean| | | |
Air Filter| Check| | Clean*| | Replace
Spark Plug| | | | Check/Clean| Replace
Spark Arrestor| | | | Check/Clean|
Service more frequently if operating in dry and dusty conditions
ENGINE OIL MAINTENANCE
Engine Oil Specification
- Only use the engine oil specified in Figure ll
- Only use 4-stroke/cycle engine oil. NEVER USE
- TROKE/CYCLE OIL Synthetic oil is an acceptable substitute for conventional oil
CHECKING ENGINE OIL
NOTICE
Always maintain proper engine oil level. Failure to maintain proper engine oil
level could result in severe damage to the engine and/or shorten the life of
the engine.
Always use the specified engine oil. Failure to use the specified engine oil
can cause accelerated wear and/ or shorten the life of the engine.
Engine oil level should be checked before every use
- Always operate or maintain the inverter on a flat surface
- Stop engine if running
- Let engine sit and cool for several minutes (allow crankcase pressure to equalize)
- Remove the engine service panel to access the oil fill/drain plug
- With a damp rag clean around the oil fill/drain plug.
- Remove the oil fill/drain plug.
- Check oil level: When checking the engine oil, remove the oil fill/ drain plug
• The oil level is acceptable if oil is visible at the bottom of the threads of the oil fill plug + foil level is low, aid to the correct level using the supplied oil fill bottle. Do not overfill the oil crankcase
NOTICE
Engine oil must always be checked and added when the inverter is on a flat,
level surface, or an accurate reading may result, causing serious engine
damage.
ADDING ENGINE OIL
- Always operate or maintain the inverter on a flat surface.
- Stop engine if running
- .Let engine sit and cool for several minutes (allow crankcase pressure to equalize).
- Remove the engine service panel to gain access to the oil fill/drain plug
- Thoroughly clean around the oil fill/drain plug
- Remove the oil fill/drain plug.
- Select the proper engine oil as specified in Figure Il
- Using the supplied oil funnel, slowly add engine oil to the engine. Stop frequently to check the oil level and avoid overfilling.
- Continue to add oil until the oil is at the correct level
CHANGING ENGINE OIL
Engine Oil Specification
- Stop the engine.
- Let engine sit and cool for several minutes (allow crankcase pressure to equalize).
- Remove the engine service panel to gain access to the oil fill/drain plug
- Place oil pan (or suitable container) under the oil fill/ drain plug (see Figure 12).
- With a damp rag, thoroughly clean around the oil fill/drain plug.
- Tilt the inverter so the oil drains down the through into the container.
- Allow oil to completely drain.
- Fill crankcase with oil following the steps outlined in Adding Engine Oil on page 17.
- Dispose of used engine oil properly.
NOTICE
Never dispose of used engine oil by dumping the oil into a sewer, on the
ground, or into groundwater or waterways. Always be environmentally
responsible Follow the guidelines or other governmental agencies for proper
disposal of hazardous materials. Consult local authorities or reclamation
facility.
AIR FILTER MAINTENANCE
WARNING
Never use gasoline or other flammable solvents to clean the air filter. Use
only household detergent soap to clean the air filter,
Cleaning the Air Filter
The air filter must be cleaned after every 50 hours of use or 3 months
(frequency should be increased if inverter is operated in a dusty environment)
-
Turn off the inverter and let it cool for several minutes if running.
-
Remove the engine service panel to gain access to the air filter.
-
Unscrew the air cleaner cover and tip the cover down (see Figure 14)
-
Remove the foam element fron the air cleaner housing.
-
Wash the foam air filter element by submerging the element in a solution of household detergent soap and warm water. Slowly squeeze the foam to thoroughly clean.
NOTICE
NEVER twist or tear the foam air filter element during cleaning or drying. Only apply slow but firm squeezing action -
Rinse in clean water by submerging the air filter element in fresh water and applying a slow squeezing action (see Figure 15). NOTICE
Never dispose of soap cleaning solution used to clean the air filter by dumping the solution into a sewer, on the ground, or into ground water or waterways. Always be environmentally responsible. Follow the guidelines or other governmental agencies for proper disposal of hazardous materials. Consult local authorities or reclamation facility. -
Dispose of used soap cleaning solution properly.
-
Dry the air filter element by again applying a slow firm squeezing action
-
Return the air filter element to its position in the air cleaner housing
-
Install the air cleaner cover, making sure the tabs lock into place.
-
Install the engine service panel
DRAINING THE FLOAT BOWL
-
Remove the engine service panel to access the carburetor.
-
Locate the clear plastic hose from the float that is exiting out the bottom of the inverter, and place a suitable container under it to catch the drained fuel (see Figure 16)
-
Loosen the float bowl drain screw (see Figure 17) until fuel is seen draining from the float bowl
-
Allow fuel to drain into the container, and then tighten the float bowl drain screw
NOTICE
Never dispose of fuel by dumping fuel into a sewer, on the ground, or into groundwater or waterways. Always be environmentally responsible. Follow the guidelines or other governmental agencies for proper disposal of hazardous materials. Consult local authorities or reclamation facility. -
Install the engine service panel
SPARK PLUG MAINTENANCE
The spark plug must be checked and cleaned after every 100 hours of use or 6
months and must be replaced after 300 hours of use or every year.
-
Stop the inverter and let it cool for several minutes if running.
-
Move the inverter to a flat, level surface.
-
Slide the spark plug access cover off the housing (see Figure 18).
-
Remove the spark plug boot by firmly pulling the plastic spark plug boot handle directly away from the engine.
NOTICE
Never apply any side load or move the spark plug laterally when removing the spark plug. Applying a side load or moving the spark plug laterally may crack and damage the spark plug boot. -
Clean area around the spark plug.
-
Using the spark plug socket wrench provided, remove the spark plug from the cylinder head (see Figure 19).
-
Place a clean rag over the opening created by the removal of the spark plug to make sure no dirt can get into the combustion chamber.
-
Inspect the spark plug for:
• Cracked or chipped insulator
• Excessive wear
• Spark plug gap of 0.032 in. ( 0.80 mm).
If the spar plug tails any one of a conditions listed above, replace the plug. NOTICE
Only use the recommended spark plug. See chart below. Using a non- recommended spark plug could result in damage to the engine. -
Install the spark plug by carefully following the steps outlined below:
a. Carefully insert the spark plug back into the cylinder head. Hand-thread the spark plug until it bottoms out.
b. Using the spark plug socket wrench provided, turn the spark plug to ensure it is fully seated.
c. Replace the spark plug boot, making sure the boot fully engages the spark plug’s tip.
d. Install the spark plug access coven
BRAND | TYPE |
---|---|
TORCH | A5RTC |
NGK | CR7HS |
CLEANING THE SPARK ARRESTOR
Check and clean the spark arrestor after every 100 hours of use or 6 months.
-
Stop the inverter and let it cool for several minutes if running.
-
Move the inverter to a flat, level surface
-
Remove the screws holding the muffler cover in place (see Figure 20).
-
Loosen the clamp holding the spark arrestor onto the muffler.
-
Slide the spark arrestor band clamp off the spark arrestor screen.
-
Pull the spark arrestor screen off the muffler exhaust pipe.
-
Using a wire brush, remove any dirt and debris that may have collected on the spark arrestor screen.
-
If the spark arrestor screen shows signs of wear rips, tears or large openings in the screen) replace the spark arrestor screen.
-
Install the spark arrestor components in the following order.
a. Place spark arrestor screen over the muffler exhaust pipe. Push on the screen until it fully bottoms out.
b. Place the spark arrestor band clamp over the screen and tighten with a flathead screwdriver -
Replace the discharge gate.
CLEANING THE INVERTER
It is important to inspect and clean the inverter before every use.
Clean All Engine Air Inlet and Outlet Ports – Make sure all engine air inlet
and outlet ports are clean of any dirt and debris to ensure the engine does5
not run hot.
STORAGE
WARNING
Never store an inverter with fuel in the tank indoors or in a poorly
ventilated area where the fumes can come in contact with an ignition source
such as a: 1) pilot light of a stove, water heater, clothes dryer or any other
gas appliance; or 2) spark from an electric appliance.
NOTICE
Gasoline stored for as little as 60 days can go bad, causing gum, varnish
and corrosive buildup in fuel lines, fuel passages and the engine. This
corrosive buildup restricts the flow of fuel, preventing an engine from
starting after a prolonged storage period.
Proper care should be taken to prepare the inverter for any storage
- Clean the inverter as outlined in Cleaning the Inverter.
- Siphon all gasoline from the fuel tank as best as possible.
- Start the engine and allow the inverter to run until all the remaining gasoline in the fuel lines and carburetor is consumed and the engine shuts off.
- Drain any remaining fuel from the float bowl. See Draining the Float Bowl on page 19.
- Change the oil (see Changing Engine Oil on page 18).
- Remove the spark plug (see Spark Plug aintenance on page 20) and place about 1 tablespoon of oil in the spark plug opening. While placing a clean rag over the spark plug opening, slowly pull the recoil handle to allow the engine to turn over several times. This will distribute the oil and protect the cylinder wall from corroding during storage.
- Replace the spark plug (see Spark Plug Maintenance on page 20).
- Move the inverter to a clean, dry place for storage.
TROUBLESHOOTING
WARNING
Before attempting to service or troubleshoot the generator, the owner or
service technician must first read the owner’s manual and understand and
follow all safety instructions. Failure to follow all instructions may result
in conditions that can lead to voiding certification or product warranty,
serious personal injury, property damage or even death
PROBLEM | POTENTIAL CAUSE | SOLUTION |
---|---|---|
Engine is running, but no electrical output. | 1. Reset breaker is tripped. |
1. Reset the reset breaker (see page 15).
2. The power cord’s plug connector is not fully engaged in the inverter’s
outlet.| 2.Verily plug connector is firmly engaged in the inverter’s outlet.
3.Faulty or defective power cord.| 3. Replace power cord.
4. Faulty or defective electrical appliance.| 4. Try connecting a known good
appliance to verify the inverter is producing electrical power.
Engine will not start or remain running while trying to start.| 1. Inverter
is out of gasoline.| 1. Add gasoline to the inverter (see page 13).
2. Fuel flow is obstructed.| 2 Inspect and clean fuel delivery passages.
3. Dirty air filter.| 3. Check and clean the air filter (see page 18).
4. Low oil level shutdown switch is preventing the unit from starting.|
4.Check oil level and add oil if necessary (see page 17).
5.Spark plug boot is not fully engaged with the spark plug tip.| 5. Firmly
push down on the spark plug boot to ensure the boot is fully engaged.
6. Spark plug is faulty.| 6. Remove and check the spark plug. Replace if
faulty (see pages 20).
7. Dirty/plugged spark arrestor.| 7. Check and clean the spark arrestor (see
page 21).
8. Stale fuel.| 8. Drain fuel and replace with fresh fuel.
Inverter suddenly stops running.| 1. Inverter is out of fuel.| 1. Check fuel
level (see page 13). Add fuel if necessary.
2. The low oil shut down switch has stopped the engine.| 2.Check oil level
and add oil if necessary (see page 17).
3.Too much load.| 3. Restart the inverter and reduce the load.
Engine runs erratic; does not hold a steady RPM.| 1.Choke was left in the
CHOKE position.| 1. Move choke to the RUN position.
2.Dirty air filter.| 2 Clean the air filter (see page 18).
3.Applied loads maybe cycling on and off.| 3. As applied loads cycle, changes
in engine speed may occur; this is a normal condition.
MXR3500 SCHEMATICS MAINTENANCE NOTES
APEX ES SPECIALISTS, S.L.
Calle Puerto de la Morcuera, 13, PL. 1 OF. 18-8 28919 Legan~s Madrid
hongqing Guoyu Technology Co., Ltd