profi-pumpe 750 Clean-Star Submersible Pumps Instruction Manual
- June 13, 2024
- profi-Pumpe
Table of Contents
- Models
- SAFETY INSTRUCTION AND WARNINGS
- INTRODUCTION
- IN GENERAL
- RANGES OF APPLICATION
- OPERATION
- INSTALLATION
- SECURITY TIPS
- SERVICING
- GUARANTEE REGULATIONS
- RECOGNIZING AND REPAIRING OF MISTAKES
- NOTES ON PRODUCT LIABILITY
- NOTES ON DISPOSAL
- EU DECLARATION OF CONFORMITY
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
profi-pumpe 750 Clean-Star Submersible Pumps Instruction Manual
Models
-
DIRT-STAR-EXTRA-SS 400-2 (BWTP02130)
-
DIRT-STAR-EXTRA-SS 550-1
-
DIRT-STAR-EXTRA-SS 750-1 (TP02132)
-
DIRT-STAR-EXTRA-SS 550-2 (TP02131)
-
LONG-LIFE CLEAN-STAR 400 (TP01106)
-
LONG-LIFE CLEAN-STAR 750 (TP01107)
SAFETY INSTRUCTION AND WARNINGS
Please read the user manual before using the device
Pull power plug
Warning signv
Warning of electrical voltage
INTRODUCTION
We would like to congratulate you on the purchase of our pump. We appreciate your trust. That‘s why funtional security and operational safety stands by us on first place.
To prevent damage to persons or property, you should read this user manual
carefully. Please observe all safety precautions and instructions for proper
use of the pump. Failure to follow the instructions and safety precautions can
result in injury or property damage.
Please keep this manual with the instructions and safety instructions
carefully in order to at any time you can restore them. Please always download
the latest version of the user manual of www.profi-pumpe.de under „downloads“.
This shall always prevail.
IN GENERAL
The pumps are developed according to the newest stand of technology,
manufactured with much care and go under strict intensive controls.
These pumps were optimised by us in particular for the special demands in
dirty water areras.
Make sure after unpacking the pump that the data given on the type label match
with the included operating instructions. In case of doubt the pump is not to
be used.
Transport damages are immediately to be reported to the package distributor
and to us in written form.
RANGES OF APPLICATION
These pumps are made for pumping clean and dirty water. Free of abrasive components (sand, mud, aggressive chemical substances).
The pumps are made for the following ranges of application:
- Filling and emptying rain tanks and containers
- For water re-circulation
- For rainwater use in house and garden
- Pumping water from a brook a stream
- Use in a pond
- Others
IMPORTANT
The pumps are designed for pumping water and chemically non-aggressive
liquids. Any guarantee is void in case of improper use. They are not suitable
for pumping flammable liquids or for use in places where there is danger of an
explosion. The pumps are designed for home use in the house and garden.
In continuous operation mode, the lifetime will be shortened accordingly.
Never run more than 5 minutes against a closed valve pump. Save the pump
against dry running (install dry run protection).
Never start and stop the pump more than 20 times per hour. When the pump
clocks, any claim under warranty is void. Not suitable for use with solar
photovoltaic panels. Submersible pumps may not be used in swimming pools.
OPERATION
The installation must be performed by a qualified professional.
Please, check each time before using, the electrical connections and the
cables are not damaged. Check before the installation whether the electrical
connections are earthed according to the statutory regulations and are
installed. The pump is to be secured through a RCD circuit breaker with
release current of 30 mA. is technically correct, so this warranty is void. It
must be ensured that the pump is sufficiently cooled during prolonged
operation. It is not recommended to perform even cable extensions or other
technical modifications. The lines to the pump must be installed always
steadily rising. A transfer of mechanical loads or vibrations from the pump or
must be eliminated through appropriate measures (rubber buffers, braided
hoses, line fixation, etc.).If necessary, attach a sufficiently long and
strong rope to the attachment points provided before using the pump. The pump
is hung into the water tank with this retaining cable.
Note: The condition of the holding rope should be checked regularly, as it can age over time and may tear if necessary.
-
Connect the pressure line:
For occasional use a suitable water hose can be used.
For permanent installation, it is recommended to connect a reinforced hose. -
Mount the pressure line on the pressure connection. All threaded connections must be sealed with a suitable sealing tape (e. g. Teflon® tape).
-
When using a hose, screw a suitable hose adapter onto the pressure connection, slide the hose firmly onto the hose adapter and secure it with a hose clamp.
-
For the maximum immersion depth, please refer to the technical data (page 8).
-
Make sure that the intake openings are not blocked by foreign bodies. If necessary, place the unit on a firm, level surface.
-
Make sure that the device is securely attached.
INSTALLATION
If necessary, attach a sufficiently long and strong rope to the handle before using it for the first time. The pump is hooked into the water tank with this holding rope.
Note:
In the case of continuous use of the pump with a rope, the condition of the
rope must be checked regularly as it can decay and break over time.
-
Connect pressure pipe.
For occasional use, use a suitable water hose. The use of rigid pipes is recommended for use at a fixed location. This prevents return flow of the liquid when switching off. -
Screw pressure line onto the pressure connection. All threaded connections must be sealed with thread sealing tape (e. g. Teflon® tape).
-
When using a hose, screw a suitable hose adapter onto the pressure connection. – Push the hose firmly onto the hose adapter and secure with a hose clamp.
-
The pump can be lowered up to a water depth.
-
Install the appliance so that the suction openings cannot be blocked by foreign bodies (place the appliance on a firm, even base if necessary).
-
Ensure that the appliance is stable.
Schematic illustration as application example. Please refer to the quotation
description for the scope of delivery.
*) If necessary, further/different country-specific regulations must be observed.
SECURITY TIPS
- Obey absolutely valid regulations on the electrical security
- Never run pump dry
- Pumping inflammable, as well as all other aggressive liquids is prohibited
- Pay attention to the medium temperature max. 35°C
- Never pull the pump on the electrical cable or pressure hose
- Avoid cross section narrowing
- Pay attention to the given particle size
- The grain size mentioned does not refer to sand or stones but rather to soft, flexible particles such as fluff and similar which the rotor cannot wedge inside the pump.
- During longer unused times, clean the pump, wash it out with clear water, dry and store it at room temperature
- Test wells for enough flowing water (dry run danger)
- The pump is to be secured through a RCD circuit breaker with a release current of 30 mA.
- The electrical connections are always to be carried out by an authorised professional.
- The pump may be used by children aged 8 years and above as well as persons with reduced physical, sensory or mental abilities or those who lack skills, experience and knowledge only if they are supervised. These aforementioned persons should only use the appliance while adhering to safe instructions and resulting dangers.
- Cleaning and maintenance must not be carried out by children without supervision.
- The pump must not be used or operated under any circumstances when there are people in the same water.
- Under certain cirumstances, it is possible that that contamination of water is caused by leakage.
THE MANUFACTURER EXPLAINS:
- To take over no responsibility in the case of accidents or damages on the basis of carelessness or disregard to the instructions in this book.
- To reject every responsibility for the damages which originate from the improper use of the pump.
SERVICING
Under normal pumping conditions the pump requires no servicing. From an
operating period (with clear water) of approx. 2000 hours the mechanical
components should be checked: impeller wheels, chambers, sealing rings etc. on
wear and if necessary be changed.
With abrasive materials like sand the servicing duration can become
shorter.
The following controls should be carried out regularly:
- Intactness of the electric cable
- That the connection hoses are not bent or broken
- Cleanness of the pump medium
Moreover, the pump should be emptied with risk of frost, be washed out with clear water and stored dry.
GUARANTEE REGULATIONS
For all manufacturing and material defects, the statutory warranty applies. In these cases we take the replacement or repair of the pump. Shipping costs shall be borne by our company, except as required by law. Please report the warranty on our service platform http://www.profipumpe.de/service.php. We will inform you how to proceed with case-related. Returns please sufficient postage. Unfortunately not prepaid returns can not be accepted because they are filtered out before delivery. Our service we provide in Germany.
The warranty does not cover:
- Improper installation (self-installation, unauthorized persons)
- Material wear (sealing rings, impeller wheels, impeller chambers)
- Unjustified interventions or changes in the pump
- Damages by selffault
- Improper servicing and improper use
- DRY RUNNIG (Also partially!) of the pump
Moreover, we give no damage compensation for secondary damages!
RECOGNIZING AND REPAIRING OF MISTAKES
Problem | Possible cause | Solution |
---|---|---|
Pump runs, no water is being pumped | Air in the suction line | Check suction |
line and connections for vacuum tightness
Air in the system (cannot escape)| Air in the system must be let out
Impeller wheel is blocked| Impeller wheel must be cleaned
Pump does not start or switches itself off| Engine guard has switched the pump
off| Pump needs to be cooled
No electricity| Check electrical connections
Pump runs, Pump capacity slows down or stops| Pump is inserted to deep| Insert
pump not so deep
Hose connections systems have a leak| Check hose connection systems
Impeller wheel is worn down| Change impeller wheel
Filter has become dirty| Clean filter
When you turn on the pump, RCD circuit breaker is triggered| Pump could have a
leak| Check pump for moisture damage
Condensation in the electrical connection / junction box| Unplug the pump /
contact the distributor
NOTES ON PRODUCT LIABILITY
We point out, that we are only liable for damages under the Product Liability Act, which are caused by our units if no changes were made to the equipment. If repairs are carried out by our authorized service, we are only liable if original spare parts and accessories were used.
NOTES ON DISPOSAL
Electro devices of our company, labeled with the symbol of the crossed trash
bin, are not permitted to be disposed in your household garbage. We are
registered at the German registration department EAR under the WEEE-No.
DE79535656.
This symbol means, that you’re not allowed to treat this product as a regular
household waste item – it has to be disposed at a recycling collection point
of electrical devices. This is the best way to save and protect our earth.
THANK YOU FOR YOUR SUPPORT!
EU DECLARATION OF CONFORMITY
The undersigned, Amur S.à r.l., 36, Rue de la Gare, L-5540 Remich, certifies that the products named overleaf, namely DIRT-STAR-EXTRA-SS 400-2, DIRT-STAR- EXTRA-SS 550-1, DIRT-STAR-EXTRA-SS 750-1, DIRT-STAR-EXTRA-SS 550-2, LONG-LIFE CLEAN-STAR 400, LONG-LIFE CLEAN-STAR 750 as placed on the market, comply with the relevant provisions listed below, the relevant EU harmonised directives and the EU standard for safety. This declaration of conformity applies insofar as no modifications are made to the product. The sole responsibility for issuing this declaration of conformity lies with the manufacturer.
The sole authorised person to keep the technical documents:
Amur S.à r.l. – 36, Rue de la Gare – L-5540 Remich
Low Voltage Directive (2014/35/EU)
EC Electromagnetic compatibility directive (2004/108/EC)
The following harmonized standards:
EN IEC 55014-1:2021
EN IEC 55014-2:2021
EN 61000-3-3:2013+A1+A2
EN IEC 61000-3-2:2019+A1
EN 60335-1: 2012+A11+A13+A1+A14+A2
EN 60335-2-41: 2003+A1+A2
EN 62233: 2008
EN ISO 12100:2010
EK1 566-13, EK1 527-12 Rev.2
ROHS: 2011/65/EU
Signed for and on behalf of:
Amur S.à r.l.
Remich, 16.12.2022
i.V. Dipl. Phys. Peter Neumüller
Technical Manager
Amur S.à r.l.
www.amur.lu
Email: info@amur.lu
Tel.: (+49) 0611-9 45 87 77-0
Fax: (+49) 0611-9 45 87 77-11
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>