profi-pumpe HW01115 Inverter-Automatic Water Booster Pump Instruction Manual
- June 12, 2024
- profi-Pumpe
Table of Contents
- Profi-pumpe HW01115 Inverter-Automatic Water Booster Pump
- SAFETY INSTRUCTION AND WARNINGS
- INTRODUCTION
- IN GENERAL
- INSTALLATION
- OPERATION
- DESCRIPTION
- SERVICING
- GUARANTEE REGULATIONS / STATUTORY WARRANTY
- RECOGNISING AND REPAIRING MISTAKES
- TECHNICAL DATA
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Profi-pumpe HW01115 Inverter-Automatic Water Booster Pump
Product Information
The Inverter-Automatic Water Booster Pump is a high-quality pump designed for
pumping clear water. It is suitable for both private and public swimming
pools, as well as other applications that require circulating large volumes of
water. The pump is energy-efficient and features innovative technology to help
you save on costs.
Specifications
- Product Name: Inverter-Automatic Water Booster Pump
- Model: HW01115
- Version: 23.02
- Manufacturer: Original Hauswasserwerk-Inverter
- Website: www.profi-pumpe.de
Safety Instructions and Warnings
- Please read the user manual before using the device.
- Always pull the power plug before performing any maintenance or repairs.
- Be cautious of electrical voltage and follow proper safety precautions.
Installation
The installation of the pump should be performed by a qualified professional.
Before installation, check the electrical connections and cables for any
damages. Ensure that the electrical connections are properly grounded
according to statutory regulations. The pump should be secured through an RCD
circuit breaker with a release current of 30 mA. It is important to provide
sufficient cooling for the pump during prolonged operation.
Before starting the pump, check for any leaks in the pump and water lines by
performing a pressure test for at least 24 hours. If dirt is expected in the
pump, install an effective pre-filter before the pump inlet. Fill the pump and
suction pipe/hose with water. Connect the pump to the power supply and start
it. If necessary, refill the pump and suction line until normal continuous
operation is established.
Note : Ensure that the specified terminal sizes are strictly adhered to
in order to avoid any defects in the pump. In case of strong restriction of
flow on the pressure side of the pump, water may come out of the housing.
Operation
- Open the cap of the filler neck and fill in enough water for it to escape from the neck. Turn the cap clockwise to close it.
- Connect the power supply. The display will show “3.0” or “0.0 bar”.
- Set the pressure display range to show the desired pressure value. The power indicator will light up.
- Open the discharge valve and press the “RUN” button to start the pump.
- Under all operating conditions, pressing the “STOP” button will stop the pump.
To adjust the working pressure, use the “+/-” keys. A short press of the “+” key increases the pressure by 0.1 bar each time, while a short press of the “-” key reduces the pressure by 0.1 bar each time. Holding down these buttons will cause the pressure to rise or fall quickly. After setting the pressure, open a water tap. The control system will regulate the pump according to the water demand. Check that the pump is running normally and that the pressure shown on the display is constant. If you notice any irregularities, refer to the “Recognizing and Repairing of Mistakes” section in the user manual.
SAFETY INSTRUCTION AND WARNINGS
INTRODUCTION
We would like to congratulate you on the purchase of our pump. We appreciate your trust. That‘s why functional security and operational safety stand by us in the first place. To prevent damage to persons or property, you should read this user manual carefully. Please observe all safety precautions and instructions for proper use of the pump. Failure to follow the instructions and safety precautions can result in injury or property damage. Please keep this manual with the instructions and safety instructions carefully in order to at any time you can restore them. Please always download the latest version of the user manual of www.profi-pumpe.de under „downloads“. This shall always prevail.
IN GENERAL
The pumps in the category Centrifugal Pumps are developed according to the newest standard of technology, manufactured with much care, and under strict intensive controls. The pumps have been optimized by us, especially for the special requirements for circulating and filtering large volumes of water. Make sure after unpacking the pump that the data given on the type label agrees with the included operating instructions. In the case of doubt, the pump is not to be used. Transport damages are immediately to be reported to the package distributor and to us in written form.
RANGES OF APPLICATION
These pumps are made for pumping clear water (free of mud and sand, see
technical data)
The pumps are made for the following ranges of applications:
- In private and in public swimming pools
- Circulating large volumes of water
- Other Clearwater pumping
IMPORTANT!
The pumps are designed for pumping clean water and chemically non-aggressive
liquids. Any guarantee is void in case of improper use. They are not suitable
for pumping flammable liquids or for use in places where there is a danger of
an explosion. These pumps are intended for private and industrial use. These
pumps are designed for continuous use (without interruptions). In continuous
operation mode, the lifetime can be shortened accordingly. Never run more than
5 minutes against a closed valve pump. The pump has integrated dry run
protection. Never start and stop the pump more than 20 times per hour. When
the pump clocks, any claim under warranty is void. Not suitable for use with
solar photovoltaic panels.
INSTALLATION
The installation must be performed by a qualified professional. Please, check
each time before using, the electrical connections and the cables are not
damaged. Check before the installation whether the electrical connections are
earthed according to the statutory regulations and are installed. The pump is
to be secured through an RCD circuit breaker with a release current of 30 mA.
this is technically correct,
so this warranty is void. It must be ensured that the pump is sufficiently
cooled during prolonged operation.
It is NOT recommended to perform even cable extensions or any other technical
modifications. The lines to the pump must be installed always steadily rising.
A transfer of mechanical loads or vibrations from the pump or to the pump must
be eliminated through appropriate actions (use of rubber buffers, braided
hoses, line fixation, etc.). If the suction height is greater than 4m or the
suction length is greater than 9m, please make the suction line 1 1/4“
(approx. 32mm) or 1 1/2“ (approx. 38mm) instead of 25mm. Do not reduce the
suction line. All pipe/hose connections to and from the pump must be sealed
(e.g. Teflon tape or sealing cord – no hemp!). Do not reduce the suction line.
All pipe/hose connections to and from the pump must be sealed. We recommend
that you implement the suction line „as one piece“ without any interruption in
order to prevent and avoid leaks. Check pump and water lines for leaks by
pressure testing min. 24 hours. It is dirt expected in the pump, an effective
pre-filter should be
installed before the pump inlet.
Fill the pump and suction pipe/hose with water. Please connect the electrical
pump to the power supply. Start the pump. If necessary, the pump and the
suction line must be refilled until a normal continuous operation has been
established.
NOTE: Please note that a tapering of the pump connections may cause a
defect in the pump. Here, the terminal sizes specified should be strictly
adhered to. With the strong restriction of flowthrough on the
the pressure side of the pump (for example, due to a clogged sand filter)
water can come out of the housing.
OPERATION
Please open the cap of the filler neck, fill in as much water as is needed to allow it to escape from the neck, and turn the cap back in clockwise after filling the water.
- Connect the power supply, the display shows a „3,0„ or „0.0“ bar.
- Set the pressure display range to display the set pressure value and the power indicator lights up.
- Open the discharge valve, press the „RUN“ button, and start the pump.
- Under all operating conditions, pressing the „STOP“ button stops the pump.
- By pressing the “ “ or “ “ key, the setpoint value of the working pressure can be set; a short press of the “ “ key increases the pressure by 0.1 bar each time. A short press of the “ “ button reduces the pressure by 0.1 bar each, holding the buttons causes the pressure to rise or fall quickly.
- Open the water tap after setting the pressure, the control system regulates the pump according to the water demand. Check that the pump is running normally and that the pressure shown on the display is constant. If this is the case, the installation is complete. If you notice any irregularities, please read the point 10.
RECOGNISING AND REPAIRING OF MISTAKES.BUTTONS AND FUNCTIONAL
DESCRIPTION
Key function and display description | |
---|---|
NO. | NAME |
1 | STOP-button |
the of water state.
2| RUN-button| The „RUN“ button activates the operation of the pump.
3| working state| Indicates that the motor is in working state.
4| Actual pressure| Display the actual pressure value of the current pipe
network.
5| input power| Displays the current actual input power value.
6| Motor speed| Displays the current actual motor speed value.
7
| ****
Set pressure
| Displays the current set of pressure values, unit :bar. Indicates that the motor is in shutdown state.
The factory default setting value is 3 bar.
8| shutdown state| Indicates that the motor is in shutdown state.
9| Increase button| Press the button one time can increase 0.1 bar, .long time
press can increase rapidly
10| Decrease button| Press the button one time can reduce 0.1 bar, long time
press can reduced rapidly.
Fault code description | |
---|---|
NO. | Code |
1 | lU |
2 | OU |
3 | OlP |
4 | OLD |
5 | EH |
6 | EP |
7 | lP |
8 | OS |
9 | OC |
10 | OCP |
11 | EAA |
plate.
12| LL| The code displayed when the system continues to operate for more 4
hours (or more than set working hours).
SECURITY TIPS
- Obey absolutely valid regulations on electrical security
- Never run the pump dry
- Pumping inflammable, as well as all other aggressive liquids is prohibited
- Pay attention to the medium temperature max. 35°C
- Never pull the pump on the electrical cable or pressure hose
- Avoid cross-section narrowing
- Pay attention to the given particle size
- During longer unused times, clean the pump, wash it out with clear water, dry and store it at room temperature
- Test wells for enough flowing water (dry run danger)
- The pump is to be secured through an RCD circuit breaker with a release current of 30 mA.
- The electrical connections are always to be carried out by an authorized professional
- The pump may be used by children aged 8 years and above as well as persons with reduced physical, sensory, or mental abilities or those who lack skills, experience, and knowledge only if they are supervised.
- These aforementioned persons should only use the appliance while adhering to safe instructions and resulting dangers.
- Cleaning and maintenance must not be carried out by children without supervision.
- Under certain circumstances, it is possible that the contamination of water is caused by leakage.
THE MANUFACTURER EXPLAINS
- To take over no responsibility in the case of accidents or damages on the basis of carelessness or disregard for the instructions in this book.
- To reject every responsibility for the damages which originate from the improper use of the pump.
SERVICING
They must be regularly checked the pump filter and cleaned if necessary. The service intervals are based on the respective usage. We recommend a weekly control in much dirt accumulation and, if necessary daily inspection. Under normal pumping conditions, the pump requires no servicing. With abrasive materials like sand, the servicing duration can become shorter.
The following controls should be carried out regularly:
- Intactness of the electric cable
- Pre-pressure in the pressure tank (approx. 1.6 – 2.0 bar)
- That the connection hoses are not bent or broken
- Cleanness of the pump medium
- Moreover, the pump should be emptied with risk of frost, be washed out with clear water and stored dry
GUARANTEE REGULATIONS / STATUTORY WARRANTY
For all manufacturing and material defects, the statutory warranty applies. In these cases, we take the replacement or repair of the pump. Shipping costs shall be borne by our company, except as required by law. Please report the warranty on our service platform www.profi- pumpe.de/information.php. We will inform you how to proceed with case-related. Returns please sufficient postage. Unfortunately not prepaid returns can not be accepted because they are filtered out before delivery. Our service we provide in Germany. The warranty does not cover:
- Material wear (sealing rings, impeller wheels, impeller chambers)
- Unjustified interventions or changes in the pump
- Damages by segfault
- Improper servicing and improper use
- DRY RUNNING (Also partially!) of the pump Moreover, we give no damage compensation for secondary damages!
RECOGNISING AND REPAIRING MISTAKES
Problem | Possible cause | Solution |
---|
Pump runs, no wa- ter is being pumped
/ Highly fluctuating
pressure
| Air in the suction line| Check suction line and connec- tions for vacuum tightness
Air in the system (cannot escape)
| Air in the system must be let out / Press RUN key several times for a few
minutes
Impeller wheel is blocked| Impeller wheel must be cleaned
Pump does not start
or switches itself off
| Engine guard has switched the
pump off
| Pump needs to be cooled
No electricity
| ****
Check electrical connections
Pump runs, Pump capacity slows down or stops
| Pump does not suck in water| Install pump lower
Hose connections systems have a leak| Check hose connection systems
Impeller wheel is worn down| Change impeller wheel
Filter has become dirty| Clean filter
NOTES ON PRODUCT LIABILITY
We point out, that we are only liable for damages under the Product Liability
Act, which are caused by our units if no changes were made to the equipment.
If repairs are carried out by our authorized service, we are only liable if
original spare parts and accessories were used.
NOTES ON DISPOSAL
Electro devices of our company, labeled with the symbol of the crossed trash
bin, are not permitted to be disposed of in your household garbage. We are
registered at the German registration department EAR under the WEEE-No.
DE79535656. This symbol means, that you’re not allowed to treat this product
as a regular household waste item – it has to be disposed of at a recycling
collection point of electrical devices. This is the best way to save and
protect our earth.
THANK YOU FOR YOUR SUPPORT!
EU DECLARATION OF CONFORMITY
The undersigned, Amur S.à r.l., 36, Rue de la Gare, L-5540 Remich, certifies
that the product named overleaf, namely, INVERT-TECH 2 as placed on the
market, complies with the relevant provisions listed below, the relevant EU
harmonized directives, and the EU standard for safety. This declaration of
conformity applies insofar as no modifications are made to the product. The
sole responsibility for issuing this declaration of conformity lies with the
manufacturer. The sole authorized person to keep the technical documents:
Machinery Directive (2006/42/EC) Low Voltage Directive (2014/35/EU) EC
Electromagnetic Compatibility Directive (2014/30/EU)
The following harmonized standards
- EN ISO 12100:2010; EN 809:1998+A1:2009+AC:2010;
- EN 60204-1:2018; EN 60335-1:2012+A13:2017;
- EN 60335-2-41:2003+A1:2004+A2:2010;
- EN 62233:2008+AC:2008; EN 60034-1:2010+AC:2010;
- EN 55014-1:2017; EN 55014-2:2015; EN 61000-3-2:2014;
- EN 61000-3-3:2013
- RoHS: 2011/65/EU
- Signed for and on behalf of:
- Amur S.à r.l.
- Remich, 21.02.2023
- i.V. Dipl. Phys. Peter Neumüller
- Technical Manager
TECHNICAL DATA
English | Deutsch | HW01115 |
---|---|---|
Power (P1) | Leistung (P1) | 1000 W |
Max. pump capacity | Max. Fördermenge | 4,3 m³/h |
Max. pressure | Max. Druck | 4 bar |
Max. pump height | Max. Förderhöhe | 40 m |
Max. water temperature | Max. Wassertemperatur | 60°C |
Protective class | Schutzklasse | IPX5 |
Voltage | Spannung | ~230V/50 Hz |
Measures in mm | Maße in mm | 404x183x240 |
Connection in/out | Anschlüsse | 1” |
Cable length | Kabellänge | 1,5 m |
Installation scheme
Imprint
Email: info@amur.lu
Tel.: +49 611 9458777-0
Fax: +49 611 9458777-11
References
Read User Manual Online (PDF format)