Profi pumpe 250-7 Submersible Well Pumps
Specifications
- Product Name: Submersible Well Pumps (Clear Water)
- Versions Available : BRUNNEN-STAR 250-7 (BP01124), BRUNNEN-STAR 550-7 (BP01125), BRUNNEN-STAR 370-7 (BP01126), BRUNNEN-STAR 550-7 (BP01127)
- Application : Pumping clear water free of mud, sand, and aggressive chemical substances
- Water Filtration: Pre-filter water to 0.2 mm particle size
- Intended Use: Domestic water use, water circulation from containers, plain water pumping
Product Usage Instructions
-
Safety Instructions and Warnings
Please read the user manual before using the device. Ensure to pull the power plug before any maintenance or installation. Be cautious of electrical voltage. -
Introduction
Congratulations on purchasing our pump. Functional security and operational safety are our top priorities. -
Ranges of Application
The pumps are designed for pumping clear water without mud, sand, or aggressive chemicals. Water may need to be pre-filtered to 0.2 mm particle size. Suitable for domestic water use, water circulation from containers, and plain water pumping. -
Operation
Installation should be done by a qualified professional. Check electrical connections and cables for damage before each use. Ensure proper earthing of electrical connections according to regulations. Secure the pump with an RCD circuit breaker with a release current of 30 mA. Avoid cable extensions and ensure sufficient cooling during operation. -
Assembling
Assemble pump and motor modules as shown in Figure 1. Tighten screws crosswise and evenly. Mount the filter strainer as instructed. -
Installation Scheme
Follow the schematic illustration provided in the offer description for installation. Adhere to country-specific regulations if applicable. -
Security Tips
- Avoid cross-section narrowing
- Pay attention to the given particle size
- Clean the pump during long periods of disuse, wash with clear water, dry, and store at room temperature
- Test wells for sufficient flowing water to avoid dry run danger
- The pump must be secured with an RCD circuit breaker with a release current of 30 mA
- All electrical connections should be done by an authorized professional
- Children aged 8 years and above and persons with proper knowledge can use the pump
SAFETY INSTRUCTION AND WARNINGS
- Please read the user manual before using the device
- Pull power plug
- Warning sign
- Warning of electrical voltage
INTRODUCTION
We would like to congratulate you on the purchase of our pump. We appreciate your trust. That‘s why functional security and operational safety stands by us on first place.
To prevent damage to persons or property, you should read this user manual
carefully. Please observe all safety precautions and instructions for proper
use of the pump. Failure to follow the instructions and safety precautions can
result in injury or property damage. Please keep this manual with the
instructions and safety instructions carefully in order to at any time you can
restore them.
Please always download the latest version of the user manual of www.profi-
pumpe.de under „downloads“. This shall always
prevail.
IN GENERAL
The pumps are developed according to the newest stand of technology, manufactured with much care and go under strict intensive controls. These pumps were optimised by us in particular for the special demands in dirty water areras. Make sure after unpacking the pump that the data given on the type label match with the included operating instructions. In case of doubt the pump is not to be used. Transport damages are immediate to be reported to the package distributor and to us in written form.
RANGES OF APPLICATION
These pumps are made for pumping clear water (free of mud and sand and aggressive chemical substances (see technical data). The water may have to be pre-filtered to 0.2 mm particle size
The pumps are made for the following ranges of applications:
- domestic water use from wells with a diameter from 3-inch diameter
- circulation of large accumulations of water from containers
- Another plain water pumping
IMPORTANT!
- The pumps are designed for pumping clean water and chemically non-aggressive liquids. Any guarantee is void in case of improper use. They are not suitable for pumping flammable liquids or for use in places where there is a risk of explosion. The pumps are designed for home use in the house and garden.
- These pumps are designed for continuous use provided (max. 20 interruptions per hour). Never run more than 2-3 minutes against a closed valve pump. (Install dry running protection) pump adequately secured against dry running.
- The pump must not be used in swimming pools.
- Not suitable for use with solar photovoltaic panels.
OPERATION
The installation must be performed by a qualified professional.
Please, check each time before using, the electrical connections and the
cables are not damaged. Check before the installation whether the electrical
connections are earthed according to the statutory regulations and are
installed. The pump is to be secured through an RCD circuit breaker with a
release current of 30 mA. Also, it is NOT recommended to perform, for example,
a cable extension. It is not certain whether this modification is technically
correct, so this warranty is void. It must be ensured that the pump is
sufficiently cooled during prolonged operation.
ASSEMBLING
- Due to their size, pump and motor modules are delivered partly separately. The assembly is carried out as shown in Figure 1.
- Slide the motor shaft into the housing of the pump shaft. Screw the two modules together.
- Please make sure that the screws are tightened crosswise and evenly.
- Then mount the filter strainer as shown.
INSTALLATION SCHEME
SECURITY TIPS
- Obey absolutely valid regulations on the electrical security
- Never run pump dry
- Pumping inflammable, as well as all other aggressive liquids is prohibited
- Pay attention to the medium temperature max. 35°C
- Never pull the pump on the electrical cable or pressure hose
- Avoid cross-section narrowing
- Pay attention to the given particle size
- During longer unused times, clean the pump, wash it out with clear water, dry and store it at room temperature
- Test wells for enough flowing water (dry run danger)
- The pump is to be secured through a RCD circuit breaker with a release current of 30 mA.
- The electrical connections are always to be carried out by an authorised professional.
- The pump may be used by children aged 8 years and above as well as persons with reduced physical, sensory or mental abilities or those who lack skills, experience and knowledge only if they are supervised. These aforementioned persons should only use the appliance while adhering to safe instructions and resulting dangers.
- Cleaning and maintenance must not be carried out by children without supervision.
- The pump must not be used or operated under any circumstances when there are people in the same water.
- Under certain cirumstances, it is possible that the contamination of water is caused by leakage.
THE MANUFACTURER EXPLAINS:
- To take over no responsibility in the case of accidents or damages on the basis of carelessness or disregard to the instructions in this book.
- To reject every responsibility for the damages which originate from the improper use of the pump.
SERVICING
Under normal pumping conditions the pump requires no servicing. From an
operating period (with clear water) of approx. 2000 hours the mechanical
components should be checked: impeller wheels, chambers, sealing rings etc. on
wear and if necessary be changed. After 3000 pumping hours the oil in the
chamber should also be changed, if necessary (only with oil-dipped engine
types!). Please, only fill it up to 80% and check the sealing rings always for
density.
With abrasive materials like sand the servicing duration can become shorter.
The following controls should be carried out regularly:
- Intactness of the electric cable
- That the connection hoses are not bent or broken
- Cleanness of the pump medium
Moreover, the pump should be emptied with risk of frost, be washed out with clear water and stored dry.
GUARANTEE REGULATIONS
For all manufacturing and material defects, the statutory warranty applies. In these cases we take the replacement or repair of the pump. Shipping costs shall be borne by our company, except as required by law. Please report the warranty on our service platform http://www.profi-pumpe.de/service.php. We will inform you how to proceed with case-related. Returns please sufficient postage. Unfortunately not prepaid returns can not be accepted because they are filtered out before delivery. Our service we provide in Germany.
The warranty does not cover:
- Improper installation (self-installation, unauthorized persons)
- Material wear (sealing rings, impeller wheels, impeller chambers)
- Unjustified interventions or changes in the pump
- Damages by selffault
- Improper servicing and improper use
- DRY RUNNING (Also partially!) of the pump
Moreover, we give no damage compensation for secondary damages!
RECOGNISING AND REPAIRING MISTAKES
Problem | Possible cause | Solution |
---|
Pump runs, no water is being pumped
| Air in the system (cannot es-
cape)
| Air in the system must be let out
Impeller wheel is blocked| Impeller wheel must be cleaned
Pump does not start or swit- ches itself off
| Engine guard has switched the pump off| Pump needs to be cooled
No electricity| Check electrical connections
Pump runs, Pump capacity
slows down or stops
| Pump is inserted to deep| Insert pump not so deep
Hose connections systems
have a leak
| Check hose connection systems
Impeller wheel is worn down| Change impeller wheel
Filter has become dirty| Clean filter
NOTES ON PRODUCT LIABILITY
We point out, that we are only liable for damages under the Product Liability
Act, which are caused by our units if no changes were made to the equipment.
If repairs are carried out by our authorized service, we are only liable if
original spare parts and accessories were used.
NOTES ON DISPOSAL
Electro devices of our company, labeled with the symbol of the crossed
trash bin, are not permitted to be disposed in your household garbage. We are
registered at the German registration department EAR under the WEEE-No.
DE79535656. This symbol means, that you’re not allowed to treat this product
as a regular household waste item – it has to be disposed at a recycling
collection point of electri-cal devices. This is the best way to save and
protect our earth.
THANK YOU FOR YOUR SUPPORT!
EU DECLARATION OF CONFORMITY
The undersigned, Amur S.à r.l., 36, Rue de la Gare, L-5540 Remich, certifies
that the product named overleaf, namely 3“/4“ Tiefbrunnenpumpe BRUNNEN-STAR
250-7, BRUNNEN-STAR 550-7, BRUNNEN-STAR 370-7, BRUNNEN-STAR 550-7 as placed on
the market, complies with the relevant provisions listed below, the relevant
EU harmonised directives and the EU standard for safety. This declaration of
conformity applies insofar as no modifications are made to the product. The
sole responsibility for issuing this declaration of conformity lies with the
manufacturer.
The sole authorised person to keep the technical documents:
- Amur S.à r.l. – 36, Rue de la Gare – L-5540 Remich
- Low Voltage Directive (2014/35/EU)
- Machinery Directive (2006/42/EC)
EC Electromagnetic compatibility directive (2014/30/EU)
The following harmonized standards:
- EN ISO 12100:2010, EN 809:1998+A1:2009+AC:2010, EN 60204-1:2006+A1:2009+AC:2010, EN 60335-1:2012+A11:2014+AC:2014, EN 62233:2008+AC:2008,
- EN 60335-2-41:2003+A1:2004+A2:2010, EN 60034-1:2010+AC:2010,
- EN 55014-1:2006+A1:2009+A2:2011, EN 5514-2:2015, EN 61000-3-2:2014,EN 61000-3-3:2013
TECHNICAL DATA / TECHNISCHE DATEN
English| Deutsch| BP01124| BP01125| BP01126|
BP01127
---|---|---|---|---|---
Power Achievement| Leistung| 250 Watt| 550 Watt| 370 Watt| 550 Watt
Max. pump capacity| Max. Fördemenge| 2,8 m³/h| 3,3 m³/h| 4,2 m³/h| 4,2 m³/h
Max. pressure| Max. Druck| 3,2 bar| 5,3 bar| 3,2 bar| 5,4 bar
Max. pump height| Max. Förderhöhe| 32 m| 53 m| 32 m| 54 m
Max. water temperature| Max. Wassertemperatur| 35°C| 35°C| 35°C| 35°C
Max. particle size| Max. Partikelgröße| 0,2 mm| 0,2 mm| 0,2 mm| 0,2 mm
Max. sand content| Max. Sandgehalt| 0,2 %| 0,2 %| 0,2 %| 0,2 %
Protection grade| Schutzklasse| IP58| IP58| IP58| IP58
Electrical tension| Spannung| 230V/50 Hz| 230V/50 Hz| 230V/50 Hz| 230V/50 Hz
Connection pressure side (IT)| Anschluss Druckseite (IG)| 1 1,4” IG| 1 1,4”
IG| 1 1,4” IG| 1 1,4” IG
Diameter with cable protection| Durchmesser mit Kabelschutz| 80 mm| 80 mm| 100
mm| 100 mm
Height| Höhe| 81 cm| 105 cm| 68 cm| 75 cm
Weight| Gewicht| 14,5 kg| 15 kg| 15,5 kg| 16 kg
Cable length| Kabellänge| 15 m| 15 m| 15 m| 15 m
- The adjacent figure shows an example of the terminal assignment if the mains cable is connected with the correct phase assignment and the co-lours on the pump are also correctly assigned to the corresponding phases.
- The electrical wiring diagram must be observed. This switch box is delivered completely assembled and must not be opened.
- In the event of malfunctions, the switch box may only be opened by a qualified specialist.
AS A PERFECT COMPLEMENT WE RECOMMEND THE INVERTER PUMP CONTROLLERS FROM PROFI-PUMPE.DE
- Automatic demand-oriented switching on and off of pumps
- ENERGY-SAVING pump operation: Up to 85% energy and cost reduction for pump operation with alternating load
- Ensures constant water pressure in the pipes
- Intelligent technology for optimum climate and environmental protection
- Pressure reducer function: reduces the maximum pump pressure to the set pressure in the piping system
- Minimizes average noise, quiet pump operation
- Avoids dangerous pressure surges in the water pipes
- Significantly increases the service life of the pump and water pipes
- Reduces the risk of flooding due to leaking water pipes
- Reliable integrated dry run protection with adjustable auto-start
- built-in check valve
- intelligent self-monitoring functions
- easy commissioning and operation due to preset default values
With an INVERTER pump control from profi-pumpe.de you save over 80% on energy, actively protect the environment and climate and save on electricity costs! In many cases, the purchase is amortized by cost savings in a very short time.
Imprint
- www.amur.lu
- Email : info@amur.lu
- Tel.: +49 611 9458777-0
- Fax : +49 611 9458777-11
FAQ
Q: Can the pump be used for pumping water with mud or sand?
A: No, the pump is designed for clear water without mud or sand.
Q: Is it necessary to pre-filter the water before using the pump?
A: Yes, it is recommended to pre-filter the water to 0.2 mm particle size.
References
- Profi-Pumpe.de Ihr Online-Shop für Pumpen und Pumpenzubehör
- Amur
- Profi-Pumpe.de Ihr Online-Shop für Pumpen und Pumpenzubehör
Read User Manual Online (PDF format)