Specifications :

  • Model: UNIVERSAL-STAR ACCU 260-4.2 – STAINLESS STEEL
  • Voltage: 24V
  • Power: 260W
  • Battery Capacity: 2000mAh (DPS01140-6)

Product Usage Instructions

  1. Introduction:
    Congratulations on purchasing our Diesel Accu Pump. Operational safety is our top priority, so please read the user manual carefully to prevent any damage to persons or property.

  2. General Information:
    These pumps are designed for pumping diesel or fuel oil ONLY. Do not use them with ignitable liquids like gasoline or kerosene.

  3. Ranges of Application:
    Ensure the pumped liquid is clean diesel/biodiesel or fuel oil without abrasive components to maintain pump life. Avoid using in places where the danger of an explosion exists.

Commissioning:

  1. Installation should be done by a qualified professional. Check battery charge and integrity before each start-up. Do not modifythe charging cable, charger, pump, or battery to avoid voiding the warranty.
  2. Operate the pump in well-ventilated areas with enough fresh air, ensuring sufficient cooling during prolonged use. Keep the pump away from weather influences and use on a flat surface with enough space from walls.
  3. Do not connect a hose longer than 5m on the pressure side. Use appropriate hose diameters and ensure the pump is switched off immediately after closing the pump nozzle to prevent damage.

Frequently Asked Questions (FAQ):

  • Q: What liquids can be pumped with this Diesel Accu Pump?
    A: This pump is designed for pumping clean diesel/biodiesel or fuel oil ONLY. Do not use it with ignitable liquids like gasoline or kerosene.

  • Q: Can I modify the pump, charging cable, or battery?
    A: It is NOT recommended to make any modifications as it may void the warranty. Always consult a professional for any changes.

  • Q: How should I store the pump when not in use?
    A: Store the pump in a dry place away from moisture and ensure it is protected from weather influences to maintain its longevity.

DIESEL ACCU PUMP
DIESEL AKKU PUMPE
Version 24.02

OPERATING INSTRUCTIONS

  • DIESEL-STAR ACCU 260-4.2 24V / 260W / 2000mAh mit 2Stk Tüllen (DPS01142-6)
  • UNIVERSAL-STAR ACCU 260-4.2 – STAINLESS STEEL 24V / 260W / 2000mAh (DPS01140-6)

Technical changes, misprints and mistakes reserved! Newest information about our products can be found online. http://www.profi-pumpe.de

SAFETY INSTRUCTION AND WARNINGS

profi-pumpe-Accu-Pump-Diesel-Akku-Pumpe-fig- \(3\)

INTRODUCTION

  • We would like to congratulate you on the purchase of our pump. We appreciate your trust. That‘s why functional security and operational safety stands on first place for us.
  • To prevent damage to persons or property, you should read this user manual carefully. Please observe all safety precautions and instructions for proper use of the pump. Failure to follow the instructions and safety precautions can result in injury or property damage.
  • Please keep this manual with the instructions and safety instructions carefully in order to at any time you can restore them.

IN GENERAL

  • The pumps in the categories Centrifugal Pumps are developed according to the newest stand of technology, manufactured with much care and go under strict intensive controls – each pump is checked individually – rests of the check-fluid could be still inside the pump or on the package. The pumps were optimized by us in particular for their special demands.
  • Make sure after unpacking the pump that the data given on the type label agree with the operating conditions. In the case of doubt the pump is not to be used. Transport damages are immediately to be reported to the package distributor and to us in written form. By transport with DHL please contact your local DHL office within 7 days.

RANGES OF APPLICATION

These pumps are made for pumping diesel or fuel oil ONLY!

IMPORTANT!

  • They are not suitable for pumping ignitable liquids like gasoline, kerosene, or for pumping at places where the danger of an explosion exists. When using flammable liquids with the pump, make sure there are no open flames, lighters, matches, cigarettes or similar things present around you.
  • These pumps are made for pumping clean diesel / biodiesel or fuel oil ONLY! The pumped liquid should not contain abrasive components. Abrasive components reduces pump life.

COMMISSIONING

  • The installation must be performed by a qualified professional.
  • Please check the battery for charge and integrity before each start-up. Furthermore, it is NOT recommended to make any changes to the charging cable, charger, pump or battery by yourself. It is not certain whether this modification is technically correct, so this warranty is void. It must be ensured that the pump is sufficiently cooled down during prolonged operation.
  • Diesel pumps are electrical products, which have to be protected against outer influences, f.e. caused by weather. Only use the pump in well-ventilated rooms and areas with enough fresh air. The floor, on which the pump may be used, should be flat. Please keep enough space from walls. Place the diesel-tank as near to the pump as possible.
  • The specified suction lift is the maximum suction at optimal conditions. The suction line to the pump has to be steadily increasing. The pump and the suction pipe must be filled with diesel/fuel oil before turning „on“ the pump. Do not reduce the cross area of suction and discharge lines. Connect suction and discharge lines to the pump by means of reinforced metal hose. Connect the check valve with filter basket (not included in the standard scope of delivery of the pump) tightly to the end of the suction line. For stationary use please place the pump on rubber pads to reduce vibration transmission to and from the pump and thereby prevent damage caused. The suction and discharge line should be connected to to the pump in such way, that no mechanical stress on the connections occurs. For example, Fix lines by pipe clamps with rubber insert on the wall.
  • CAUTION: Do not connect a hose more than 5m 1 inch on the pressure side. For smaller hose diameters, use
    corresponding short hoses. When using a pump nozzle, it is absolutely necessary to ensure that the pump is switched off immediately after the nozzle is closed. These measures must be adhered to in order to avoid damage of pumps.

INSTALLATION

  • Connect all parts as shown in point 13.
    (Note: The suction line must be filled with the medium used before switching on the pump).

  • Fully charge the battery before use. Connect the battery to the device and start the pump with the on/off switch.

  • Refuel as usual.

  • When fueling is complete, return the nozzle to its storage position and turn off the pump immediately.

Schematic drawings can be found on page 13
Please install the pump on solid walls or grounds. DO NOT attach the pump to cavity or gypsum walls, as these can amplify vibration, damaging the pump and significantly increasing the pump‘s operating noise. Always use vibration dampers for installation to avoid damage to the pump.profi-pumpe-Accu-Pump-
Diesel-Akku-Pumpe-fig- \(5\)

SECURITY TIPS

  • Obey absolutely valid regulations on the electrical security
  • It is recommended not to let the pump operate for more than 30-40 min. at a time (risk of overheating)
  • Never run pump dry. The idle time should not exceed 30 seconds
  • Never run pump against pressure
  • Pumping inflammable, as well as all other aggressive liquids, except of diesel or fuel oil, is prohibited
  • Never pump liquid food products
  • Before usage, check on the tightness of the hose clamps
  • Pay attention to the max. liquid temperature of 35°C
  • Switch off pump immediately after usage.
  • The pump must not operate against closed tap valve for more than 1-2 minutes
  • Don’t move the pump in any way, while it’s running. It is recommended to work for 30-40 minutes at a time
  • During longer unused times, clean the pump, wash it out with diesel or fuel oil, dry and store it at room temperature
  • ALWAYS supervise and watch the pump, while using
  • Operation can not be performed by children and young people under 16 and people with intellectual disabilities
  • The pump must be protected from rain and moisture. The pump may only be operated in dry rooms.
  • The ingress of water into the energized components of the pump increases the risk of electric shock or short circuit of the battery.

THE MANUFACTURER EXPLAINS:

  • To take over no responsibility in the case of accidents or damages on the basis of carelessness or disregard to the instructions in this user manual.
  • To reject every responsibility for the damages which originate from the improper use of the pump

BATTERY INFORMATION

  • After 12 to 18 months, you should replace the battery. For this purpose open the battery cover and replace the battery with a new. Please find the item number of the replacement battery in section 15. Technical data and order at www.profi-pumpe.de
  • Please note the limited implied warranty of 6 months.

Important! It must be ensured that the battery cover is properly tightened and watertight.

  • With repeated charge and discharge cycles Lead-Acid and NiMh battery packs are less efficient (memory effect).
  • This effect is much less pronounced, but still present in small mass in the Li-ion batteries used.
  • Through very short and frequent loading operations and many other operational influences batteries can age pre-maturely strong. The batteries are therefore subject to a consumable and wearing part of a shortened warranty of 6 months.
  • If you find that the battery will be less efficient, the battery needs to be fully charged. These allow the unit for 2 to 3 days (pump should not be connected) standing in the sun in order to allow a maximum charge the battery or use a suitable external charger. We recommend to occasionally repeat this procedure to extend the battery life.
  • If after this recharging the battery still does not meet expectations, you should replace the batteries.
  • NOTE: The battery is supplied charged. If the state of charge, contrary to expectations, not be sufficient to charge the batteries for at least 8 hours to allow sufficient charging of the battery (so damage the battery to avoid overcharging, the pump must be connected).

WARNINGS ON BATTERY
Lithium Ion cells and battery may get hot, explode or ignite and cause serious injury if they are exposed to abusive conditions, Be sure to follow the safety warnings listed below:

  • Do not install the battery backwards, so the polarity is reversed
  • Do not connect the positive or/and negative terminal or/and the battery to each other with any meta object, such as wire
  • Do not disassemble or modify the battery. The battery contains safety and protection devices which may cause the battery to generate heat, explode or ignite if damaged
  • Do not place the battery in or near fire, on stoves or other high temperature locations. Do not place the battery in direct sunlight or use/store the battery inside cars during hot weather. Doing so may cause the battery to generate heat, explode or ignite
  • It is not advised for children to handle the battery
  • When the battery is worn out, wrap the terminals with adhesive tape or similar materials before disposal
  • Immediately discontinue use of the battery, if there is an unusual smell, a change of color or shape, or if it appears abnormal in any other way
  • Do not place the battery in microwave ovens, high pressure containers or on cookware facilities
  • In the event of the battery is leaking and fluid gets into your eye, do not rub the eye, rinse well with water and immediately seek medical advice. If left untreated, the battery fluid could cause serious injury to the eye

SERVICING

Under normal pumping conditions the pump requires no servicing. But it is important to keep the suctions and delivery sections perfectly clean and free from all clogging. At a very often usage or through incorrect electrical loading, it could lead to an incorrect function of the battery. In this case, the battery should be exchanged as soon as possible. Please check before charging the integrity of the cable to the battery charger and power plug. In case of doubt, the operation is not permitted.

The following controls should be carried out regularly:

  • Intactness of the electric cable
  • That the connection hoses are not bent or broken
  • Cleanness of the pump medium

Moreover, the pump should be emptied at risk of frost, be washed out with diesel/fuel oil and stored dry.

GUARANTEE REGULATIONS / STATUTORY WARRANTY

  • For all manufacturing and material defects, the statutory warranty applies. In these cases we take the replacement or repair of the pump. Shipping costs shall not be borne by our company, except as required by law. Please report the warranty on our service platform http://www.profi-pumpe.de/service.php . We will inform you how to proceed with case-related. Please mark returns sufficient postage. Unfortunately not prepaid returns can not be accepted because they are filtered out before destination. We provide our service in Germany.

  • The warranty does not cover:

    • Material wear (sealing rings, impeller wheels, impeller chambers, battery)
    • Unjustified interventions or changes in the pump
    • Damages by self fault
    • Improper servicing and improper use
    • DRY RUNNING (Also partially!) of the pump
  • Moreover, we give no damage compensation for secondary damages!

RECOGNISING AND REPAIRING OF MISTAKES

Problem Possible causes Solutions
The pump won’t start Battery not fully loaded or defect Charge the battery

again or exchange it
Impeller jammed| Check for signs of damage and clogging. Reassemble.
Motor malfunction| Contact your dealer.
The suction of the pump is not working| Leak in suction lines or connections| Check the suction pipe and all connections for tightness. Fill the suction hose and the pump. Suction hose must be laid in a

constantly rising, so that air bubbles can escape towards the pump

Motor carbon brush used up| Contact your dealer.
Reduced flow| Tank liquid level too low.| Fill up the tank.
By-pass valve jammed| Clean and re-assemble
Air in the suction tube| Make sure that the suction tube is not damaged
Filter clogged| Clean the filter.
Leakage of Diesel oil.| Check the connectors and gaskets.
The suction tube is resting on the bottom of the tank.| Raise the tube in the tank.
Excessive suction height.| Lower the level of the pump.

NOTES ON PRODUCT LIABILITY
We point out, that we are only liable for damages under the Product Liability Act, which are caused by our units if no changes were made to the equipment. If repairs are carried out by our authorized service, we are only liable if original spare parts and accessories were used.

NOTES ON DISPOSAL

  • Electro devices of our company, labeled with the symbol of the crossed trash bin, are not permitted to be disposed in your household garbage. We are registered at the German registration department EAR under the WEEE-No. DE79535656. This symbol means, that you’re not allowed to treat this product as a regular household waste item – it has to be disposed at a recycling collection point of electrical devices. This is the best way to save and protect our earth.
  • THANK YOU FOR YOUR SUPPORT!
  • In connection with the sale of batteries or with the delivery of equipment containing rechargeable battery packs, the seller is obliged to draw your attention to the following:
  • You are obliged to return used batteries as an end-user. You can return batteries after use to the seller or to the designated collection facilities, which are free of charge (eg: municipal collection points or in stores). You can return the batteries for disposal at no charge to the seller.

EU DECLARATION OF CONFORMITY

  • The undersigned, Amur S.à r.l., 36, Rue de la Gare, L-5540 Remich, certifies that the products named overleaf, namely DIESEL-STAR ACCU 260-4.2 as placed on the market, comply with the relevant provisions listed below, the relevant EU harmonised directives and the EU standard for safety. This declaration of conformity applies insofar as no modifications are made to the product. The sole responsibility for issuing this declaration of conformity lies with the manufacturer.
  • The sole authorised person to keep the technical documents: Amur S.à r.l. – 36, Rue de la Gare – L-5540 Remich
  • EU Machinery Directive (2006/42/EC)
  • Low Voltage Directive (2014/35/EU)
  • EC Electromagnetic compatibility directive (2014/30/EU)
  • The following harmonized standards:
  • EN IEC 61326-1:2021, EN 55011:2016+A2:2021, EN IEC 61000-3-2:2019+A1:2021, EN 61000-3-3:2013+A2:2021
  • Signed for and on behalf of Amur S.à r.l.:

SCHEMATIC DRAWINGS

profi-pumpe-Accu-Pump-Diesel-Akku-Pumpe-fig- \(10\)Example application with diesel or oil

TECHNICAL DATA

| UNIVERSAL-STAR ACCU 260-4.2 **STAINLESS STEEL*** (DPS01140-6)|
---|---|---
Suitable for| Diesel, fuel oil| water, food oil, juice, wine, diesel, biodiesel, fuel oil, machine oil and petroleum
Power| 260 Watt| 260 Watt
Max. pump rate Qmax| 45 l/min| 45 l/min
Max. head Hmax| 10m| 10m
Max. suction height| 8m| 8m
Rated voltage| 24V| 24V
Lithium battery capacity| 2000 mAh Li-Ion| 2000 mAh Li-Ion
Connection| 3/4” IG / 25mm| 25mm
Protection grade| IPX4| IPX4
Pump body|  plastic| plastic
Pump head| Grey cast iron| stainless steel
Dimensions (l/w/h)| 26.5x18x20.5cm| 26.5x18x20.5cm
Weight (in kg)| 4,2kg| 4kg

  • *For more detailed information, please visit www.profi-pumpe.de All products listed in this manual are Made in PRC.
  • Please note our disposal advice at section 11.

SPARE PARTS

The spare parts will be available for purchase from AMUR S.à.r.l. at www .profi-pumpe.de .

profi-pumpe-Accu-Pump-Diesel-Akku-Pumpe-fig- \(11\) profi-pumpe-Accu-Pump-Diesel-Akku-Pumpe-fig-
\(12\) Imprint

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

profi-Pumpe User Manuals

Related Manuals