profi-pumpe 750-4 4 Inch Brunnen-Star Submersible Well Pumps Instruction Manual

June 12, 2024
profi-Pumpe

profi-pumpe 750-4 4 Inch Brunnen-Star Submersible Well Pumps Instruction

Manual

profi-pumpe 750-4 4 Inch Brunnen-Star Submersible Well
Pumps.JPG

Technical changes, misprints and mistakes reserved! Newest information about our products can be found online
http://www.profi-pumpe.de

SAFETY INSTRUCTION AND WARNINGS

FIG 1 SAFETY INSTRUCTION AND WARNINGS.JPG

1. INTRODUCTION

We would like to congratulate you on the purchase of our pump. We appreciate your trust.
That‘s why funtional security and operational safety stands by us on first place.
To prevent damage to persons or property, you should read this user manual carefully. Please observe all safety precautions and instructions for proper use of the pump. Failure to follow the instructions and safety precautions can result in injury or property damage.

Please keep this manual with the instructions and safety instructions carefully in order to at any time you can restore them. Please always download the latest version of the user manual of www.profi-pumpe.de under „downloads“. This shall always prevail.

2. IN GENERAL

The pumps are developed according to the newest stand of technology, manufactured with much care and go under strict intensive controls. These pumps were optimised by us in particular for the special demands in dirty water areras. Make sure after unpacking the pump that the data given on the type label match with the included operating instructions. In case of doubt the pump is not to be used.

Transport damages are immediately to be reported to the package distributor and to us in written form.

3. RANGES OF APPLICATION

These pumps are made for pumping clear water (free of mud and sand and aggressive chemical substances (see technical data). The water may have to be pre-filtered to 0.2 mm particle size

The pumps are made for the following ranges of application:
l domestic water use from wells with diameter from 4-inch diameter
l circulation of large accumulations of water from containers
l Other plain water pumping

**IMPORTANT!**
The pumps are designed for pumping clean water and chemically non-aggressive liquids. Any guarantee is void in case of improper use. They are not suitable for pumping flammable liquids or for use in places where there is a risk of explosion. The pumps are designed for home use in the house and garden.

These pumps are designed for continuous use provided (max. 20 interruptions per hour). Never run more than 2-3 minutes against a closed valve pump. (Install dry running protection) pump adequately secured against dry running.
The pump must not be used in swimming pools.
Not suitable for use with solar photovoltaic panels.

4. OPERATION

**** The installation must be performed by a qualified professional.
Please, check each time before using, the electrical connections and the cables are not damaged. Check before the installation whether the electrical connections are earthed according to the statutory regulations and are installed. The pump is to be secured through a RCD circuit breaker with release current of 30 mA.

Also, it is NOT recommended to perform, for example, a cable extension. It is not certain whether this modification is technically correct, so this warranty is void. It must be ensured that the pump is sufficiently cooled during prolonged operation.

5. ASSEMBLING

Due to their size, pump and motor modules are delivered partly separately. The assembly is carried out as shown in Figure 1.

Slide the motor shaft into the housing of the pump shaft. Screw the two modules together.
Please make sure that the screws are tightened crosswise and evenly.

Then mount the filter strainer as shown.

FIG 2 ASSEMBLING.JPG

6. INSTALLATION SCHEME

The installation must be carried out as shown in Fig. 2a. We recommend the installation of a pressure switch (Fig. 2b), which monitors the function of the pump and protects it from damage.

FIG 3 INSTALLATION SCHEME.JPG

7. SECURITY TIPS

  • Obey absolutely valid regulations on the electrical security
  • Never run pump dry
  • Pumping inflammable, as well as all other aggressive liquids is prohibited
  • Pay attention to the medium temperature max. 35°C
  • Never pull the pump on the electrical cable or pressure hose
  • Avoid cross section narrowing
  • Pay attention to the given particle size
  • During longer unused times, clean the pump, wash it out with clear water, dry and store it at room temperature
  • Test wells for enough flowing water (dry run danger)
  • The pump is to be secured through a RCD circuit breaker with a release current of 30 mA.
  • The electrical connections are always to be carried out by an authorised professional.
  • The pump may be used by children aged 8 years and above as well as persons with reduced physical, sensory or mental abilities or those who lack skills, experience and knowledge only if they are supervised. These aforementioned persons should only use the appliance while adhering to safe instructions and resulting dangers.
  • Cleaning and maintenance must not be carried out by children without supervision.
  • The pump must not be used or operated under any circumstances when there are people in the same water.
  • Under certain cirumstances, it is possible that contamination of water is caused by leakage.

THE MANUFACTURER EXPLAINS:

  • To take over no responsibility in the case of accidents or damages on the basis of carelessness or disregard to the instructions in this book.
  • To reject every responsibility for the damages which originate from the improper use of the pump.

8. SERVICING

Under normal pumping conditions the pump requires no servicing. From an operating period (with clear water) of approx. 2000 hours the mechanical components should be checked: impeller wheels, chambers, sealing rings etc. on wear and if necessary be changed. After 3000 pumping hours the oil in the chamber should also be changed, if necessary (only with oil-dipped engine types!). Please, only fill it up to 80% and check the sealing rings always for density.

With abrasive materials like sand the servicing duration can become shorter.

The following controls should be carried out regularly:

  • Intactness of the electric cable
  • That the connection hoses are not bent or broken
  • Cleanness of the pump medium

Moreover, the pump should be emptied with risk of frost, be washed out with clear water and stored dry.

9. GUARANTEE REGULATIONS

For all manufacturing and material defects, the statutory warranty applies. In these cases we take the replacement or repair of the pump. Shipping costs shall be borne by our company, except as required by law. Please report the warranty on our service platform http://www.profipumpe.de/service.php. We will inform you how to proceed with case-related. Returns please sufficient postage. Unfortunately not prepaid returns can not be accepted because they are filtered out before delivery. Our service we provide in Germany.

The warranty does not cover:

  • Improper installation (self-installation, unauthorized persons)
  • Material wear (sealing rings, impeller wheels, impeller chambers)
  • Unjustified interventions or changes in the pump
  • Damages by selffault
  • Improper servicing and improper use
  • DRY RUNNIG (Also partially!) of the pump

Moreover, we give no damage compensation for secondary damages!

10. RECOGNISING AND REPAIRING OF MISTAKES

FIG 4 RECOGNISING AND REPAIRING OF MISTAKES.JPG

11. NOTES ON PRODUCT LIABILITY

We point out, that we are only liable for damages under the Product Liability Act, which are caused by our units if no changes were made to the equipment. If repairs are carried out by our authorized service, we are only liable if original spare parts and accessories were used.

12. NOTES ON DISPOSAL

Electro devices of our company, labeled with the symbol of the crossed trash bin, are not permitted to be disposed in your household garbage. We are registered at the German registration department EAR under the WEEE-No. DE79535656.
This symbol means, that you’re not allowed to treat this product as a regular household waste item – it has to be disposed at a recycling collection point of electrical devices. This is the best way to save and protect our earth.
THANK YOU FOR YOUR SUPPORT!

13. EU DECLARATION OF CONFORMITY

The undersigned, Amur S.à r.l., 36, Rue de la Gare, L-5540 Remich, certifies that the products named overleaf, namely 4” BRUNNEN-STAR 750-4, 4” BRUNNEN- STAR 1500-4, 4” BRUNNENSTAR 1500-5 as placed on the market, comply with the relevant provisions listed below, the relevant EU harmonised directives and the EU standard for safety. This declaration of conformity applies insofar as no modifications are made to the product. The sole responsibility for issuing this declaration of conformity lies with the manufacturer.

The sole authorised person to keep the technical documents:
Amur S.à r.l. – 36, Rue de la Gare – L-5540 Remich

Low Voltage Directive (2014/35/EU)

EC Electromagnetic compatibility directive (2014/30/EU)
EN ISO 12100:2010; EN 809:1998+A1:2009+AC:2010; EN 60204-1:2018;
EN 60335-1:2012+A 11:2014+A13:2017+A1:2019+A14:2019+A2:2019; EN
60335-2-41:2003+A1:2004+A2:2010; EN 62233:2008+AC:2008; EN 55014-
1:2017+A11:2020; EN 55014-2:2015; EN IEC 61000-3-2:2019; EN 61000-3-
3:2013+A1:2019

ROHS: 2011/65/EU
Signed for and on behalf of:
Amur S.à r.l.
Remich, 22.12.2022
i.V. Dipl. Phys. Peter Neumüller

Technical Manager

Imprint

Amur S.à r.l.
www.amur.lu
Email: [email protected]
Tel.: +49 611 9458777-0
Fax: +49 611 9458777-11

Read More About This Manual & Download PDF:

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

profi-Pumpe User Manuals

Related Manuals