CHORS Thiny Slim ON Surface Mounted Ceiling Light Instruction Manual
- June 12, 2024
- CHORS
Table of Contents
CHORS Thiny Slim ON Surface Mounted Ceiling Light
MOUNTING HOLES
Thiny Slim ON 30 22.1101.xxx.xxx
W | X | Y | Z |
---|---|---|---|
160 mm | 55 mm | 70 mm | 197 mm |
Thiny Slim ON 60 22.1102.xxx.xxx
W | X | Y | Z |
---|---|---|---|
100 mm | 55 mm | 250 mm | 497 mm |
Thiny Slim ON 90 22.1103.xxx.xxx
W | X | Y | Z |
---|---|---|---|
100 mm | 55 mm | 400 mm | 797 mm |
Thiny Slim ON 120 22.1104.xxx.xxx
W | X | Y | Z |
---|---|---|---|
100 mm | 55 mm | 550 mm | 1097mm |
Thiny Slim ON 150 22.1105.xxx.xxx
W | X | Y | Z |
---|---|---|---|
200 mm | 55 mm | 650 mm | 1397 mm |
ELECTRICAL WIRING DIAGRAMS
ON/OFF 22.11XX.JXX.XXX
DALI 22.11XX.TXX.XXX
ASSEMBLY INSTRUCTIONS
- Turn off the power.
- Attach the profile to the ceiling with screws (A) and dowels (mounting holes scheme on the other side of the page).
- Connect the 230V power to the driver. Remember to ground (electrical wiring diagrams on the other side of the page).
- Push the strip with the LED module into the housing. Make sure that the bar is placed parallel to the housing. Be careful not to crush the LEDs. In order to disassemble the reflector, lift the bar with a screwdriver at the milling point, leaning the tool against the protected edge of the housing.
- Install the diffuser in the luminaire:
- Half the length of the lamp press the end of the diffuser to profile, and then insert.
- Press the other end of the diffuser. To pull out, gently pry with a plastic object and push out.
- Turn on the power.
The enclosed tool kit is designed for solid materials (solid brick, wood, concrete, aerated concrete) and gypsum board surfaces. The dowel should be properly matched to the mounting surface. Proper use of the dowel affects the safety and strength of the structure.
TOOLS
CUSTOMER SUPPORT
SOŁTYSOWICKA 19C | 51-168 WROCŁAW | POLAND
T: +48 71 323 14 00-01 | W: CHORS.PL
References
Read User Manual Online (PDF format)
Loading......