HAGOR Mobile Lift Pro Light Installation Guide
- June 9, 2024
- HAGOR
Table of Contents
HAGOR Mobile Lift Pro Light Installation Guide
Caution!
Technical devices are of considerable value. You should therefore handle the components carefully during installation and protect them if necessary.
If necessary, the installation area should also be secured. Falling parts can cause injuries and material damage.
The materials included in the scope of delivery may not be suitable for the special conditions at the installation site. Please check this in advance and replace it with suitable materials if necessary.
If you are unsure about the installation of the product or have any questions, please contact us or other trained specialists.
Please note
DO THE INSTALLATION WITH 2 PERSONS.
Scope of delivery
-
K. M8x12 4x
-
L. M6x8 M: 10x, F: 10x, W: 12x
-
M. M8 4x
-
N. 6 1x
-
O. 1x
-
P. M6x12 4x
-
R. M6 M: 4x, W: 8x
-
S. M10 M: 4x
-
T. M6 M: 4x
-
U. 5 1x
Not included
Assembly Instruction
Screw on both sides
Make all the necessary plug connections but do not switch them on yet.
Switch on the system and move it to the top position using the push button control. Check the cabling and free any knotted or jammed cables.
Slide the lock back up and tighten all bolts.
Remote control
UP key: Press the button, the column rises, press the button again to
stop the column or stop at the upper limit;
DOWN key: Press the button, the column descends, press the button again
to stop or stop at the lower limit;
Upper limit setting: Simultaneously press and hold the UP key + STUDY
key. After the red indicator light starts to flash rapidly for 3 seconds (the
blinking interval is about 0.5s), the column starts to rise. The red indicator
flashes quickly (the blinking interval is about 0.25s). Release the button.
Stop the red indicator light to stop flashing, the position where the column
stops is set to the upper limit;
Lower limit setting: Simultaneously hold down the DOWN key +STUDY key,
the red indicator light starts to flash rapidly after 3 seconds 0.5s), the
column starts to fall and the red indicator flashes quickly (the blinking
interval is about 0.25s), release the button to stop the red indicator to stop
flashing, and the position where the column stops is set to the lower limit;
The upper and lower limit settings are cancelled: Press and hold the
STUDY button for 5 seconds. After the red indicator light flashes twice
quickly (the flashing interval is about 0.25s), the upper and lower limit set
manually will be cancelled. The upper and lower limit settings can be
remembered after power-off, that is, after setting, power-off and power-on
remain.
Reset function: If the red indicator light on the hand controller flashes
quickly (the flashing interval is about 0.5s, which is different from the slow
flashing every 3S during working protection), the system is in the reset state
and needs to complete the reset operation to move up and down. The specific
operation is as follows: press and hold the RESET button of the hand control,
the push rod descends, and runs to the bottom, then the push rod is raised
7mm, and the small light goes out, the reset action is completed. During the
entire reset process, the RESET key must be kept pressed. At the same time,
the LED light on the hand controller flashes quickly during the entire reset
process. When the LED light is off, it indicates that the reset is complete
Remarks:
- 1). When the system enters the reset state, that is, during the reset process, all buttons except the „RESET“ button on the hand controller will not work.
- 2). When the push rod enters the abnormal state, the red indicator light is always on. Press and hold the RESET key for 5s. The push rod enters the reset state (if the RESET key is pressed and held for less than 5s, it will not work).
- 3). During normal operation of the push rod, pressing the RESET key will stop the push rod; if the RESET key is pressed at the lower limit for more than 5s, the push rod will request an active reset.
Working system protection:
The column will continue to work for 3 minutes to protect the working system.
After protection, all keys will not work, and normal operation can only be
restored after a 16-minute rest. After the system enters the working system
protection, the indicator on the hand controller flashes slowly every 3
seconds to indicate the status.
Back-off function in case of resistance:
When the system is operating normally, the column will stop when it encounters a foreign object during the lifting process, and will perform the reverse movement opposite to the movement direction. This function is still effective during the upper and lower limit setting process. 5. Battery function no.
Overcurrent protection: The column overcurrent protection value is 10±1A.
Overheat protection: Overheat protection value: 75°C; recover when it is
lower than 45°C.
Safety notice
Thank you for purchasing our lift system. Please read carefully information
before assembling and usage. Assembly should be done by qualified personal
only.
The maximum load of the unit is 120 kg. So do not mount any additional
elements exceeding this weight limit.
SAFETY WARNING: OPERATED BY CERTIFIED STAFF. WHEN NOT IN USE DISCONNECT THE REMOTE CONTROL!
Electrical safety
Connect the unit to 110 – 230 V / 50 Hz grounded power outlet only. Use the
unit in dry rooms only and protect it from water and other liquids. To avoid
risk of electric shock do not open the control box or lift the unit. There are
no serviceable parts inside. In case of problems unplug the unit from the
power outlet and contact an authorized technical service.
Mechanical safety
Mount the monitor according to the Installation Instructions. Do not
improperly weight the unit. Do not hang on unit. Before moving the unit up or
down check that the unit is not blocked by a table, chair or other similar
object. Severe risk of injury exists when the unit is tilted or falls over due
to improper use. Move the unit on plane and stable floors only. Be careful
when moving over door thresholds or in case of uneven floor Lock the wheels
brakes when operating the unit.
Special hints for wall mounting
Use appropriate wall fixing material only. Use appropriate screws according to
the wall type and material. Using improper mounting material could cause the
monitor system to fall down and cause injuries or damage the objects. Wall
mounting must be done by experienced personnel only.
Disposal: Do not dispose to consumer waste.
Diminsions
Mobile Lift Pro Light (M)
Floorstand Lift Pro Light (F)
Wall Lift Pro Light II (W)
Optional accessories
HAGOR Products GmbH
Oberbecksener Straße 97
D-32547 Bad Oeynhausen
Telefon: +49(0)57 31-7 55 07-0
Mail: hagor@hagor.de
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>