BEGA 99327 In Ground Luminaire Instruction Manual
- June 12, 2024
- BEGA
Table of Contents
BEGA 99 327 In Ground Luminaire Instruction Manual
Technical amendments reserved
99 327
In-ground luminaire
Instructions for use
Application
Location luminaire for recessed installation in compacted surfaces with ø 30
mm provided by the customer.
Drive-over luminaire from vehicles with pneumatic tyres.
Please note:
Luminaire must not be used for installation in road lanes, where the fixture is exposed to a horizontal strain due to braking, acceleration and change of direction.
Lamp
Module connected wattage: 0.14 W
Luminaire connected wattage: 0.35 W
Rated temperature: ta = 25 °C
Ambient temperature: ta max = 65 °C
99 327 K4
Colour temperature: 4000 K
Colour rendering index: CRI > 80
Module luminous flux: 25 lm
Luminaire luminous flux: 5 lm
Luminaire luminous efficiency: 14,3 lm / W
99 327 K3
Colour temperature: 3000 K
Colour rendering index: CRI > 80
Module luminous flux: 25 lm
Luminaire luminous flux: 5 lm
Luminaire luminous efficiency: 14,3 lm / W
Product description
In-ground LED luminaire without power supply unit
Luminaire made of stainless steel
Steel grade no 1.4301
Installation bush made of polyamide
Matt safety glass
3 m water-resistant connecting cable
05RN8-F 2 × 1 with implemented water stopper
Safety class III
Protection class IP 68 20 m
Dust-tight and water pressure tight
Maximum submersion depth 20 m
Not suitable for permanent operation under water
Impact strength IK10
Protection against mechanical impacts < 20 joule
– Safety mark
– Conformity mark
Weight: 0.35 kg
Safety
The installation and operation of this luminaire are subject to national
safety regulations.
Installation and commissioning may only be carried out by a qualified
electrician.
The manufacturer accepts no liability for damage caused by improper use or
installation.
If subsequent modifications are made to the luminaire, the person responsible
for these modifications shall be considered the manufacturer.
Please note:
The luminaire can only be operated with an operating device that fulfills the
requirements according to EN 61347-2-13.
The maximum idle voltage of 60 V DC must conform to SELV or SELV equivalent.
Installation
A separate power supply unit is required to operate the luminaire – see accessories.
For installation in drilled holes, a recessed opening of ø 30 mm with a
minimum depth of 100 mm is required to hold the installation sleeve.
Press the installation sleeve firmly into the recessed opening.
For installation in paved surfaces, the appropriate installation housing is
70 778 available.
In this case, the polyamide installation sleeve is not used.
The cable connection must be established on site with the correct protection
class and safety class for the luminaire.
We recommend that you use distribution box 70 730 or 71 053 for this
purpose.
To protect the luminaire power supply cable against damage we recommend you to
use a PVC conduit on-site.
A 24 V safety direct voltage source with a smoothed residual ripple of max. 10
% is required for the electrical connection of the luminaire – see
accessories.
If other safety direct voltage sources are used, an upstream fuse (max. 6 A)
must be provided by the customer.
The black wire is to be connected to the negative terminal, the red wire to
the positive terminal on the power supply unit.
Press the luminaire into the installation sleeve.
Cleaning · Maintenance
After installation, the luminaire should first be cleaned. Building dust,
residues from contact adhesives, paint splashes and rust film must be
completely removed. Never use high pressure cleaners and cleaning implements
made of normal steel, steel brushes or steel wool because they cause
extraneous rust to form.
When using stainless steel cleaners, please read the directions carefully.
Cleaning agents containing hydrochloric acid and chlorides should never be
used.
We recommend cleaning the luminaires regularly.
Accessories
Power supply unit for LED luminaires 24 V DC
Safety transformer according to EN 61558/VDE 0570 part 2-6
70 564 Power supply unit for 5-15 W
70 465 Power supply unit for 10-25 W
70 565 Power supply unit for 20-35 W
70 566 Power supply unit for 30-50 W
70 567 Power supply unit for 40-75 W
70 169 Power supply unit for 70-150 W
230 V ∼ 50-60 Hz
70 114 Power supply unit for 0-70 W
AC range: AC: 198-264 V ∼ 50-60 Hz
DC range: DC: 176-275 V
The power supply units are also suitable for the operation of several LED luminaires. In this case, the maximum wattage of the power supply unit must not be exceeded.
70 778 Installation housing made of stainless steel
Distribution box for installation in soil
70 730 Distribution box with 7 cable entries Connection terminals 5 x 4
71 053 Distribution box with 10 cable entries Connection terminals 6 x 16
For the accessories a separate instructions for use can be provided upon request.
Spares