BEGA 77961 In Ground Luminaire Instruction Manual
- June 12, 2024
- BEGA
Table of Contents
BEGA 77961 In Ground Luminaire
Product Information
The product is a luminaire with the following specifications:
Module Designation| Colour Temperature| Colour Rendering Index| Module
Luminous Flux| Luminaire Luminous Flux| Luminaire Luminous Efficiency
---|---|---|---|---|---
77 961 K2| 2700 K| CRI > 80| 1345 lm| 983 lm| 98.3 lm/W
77 961 R K2| 2700 K| CRI > 80| 1345 lm| 817 lm| 81.7 lm/W
77 961 K3| –| –| –| –| –
77 961 R K3| –| –| –| –| –
77 961 K4| –| –| –| –| –
77 961 R K4| 2700 K| CRI > 80| 1345 lm| 817 lm| 81.7 lm/W
The product is equipped with overvoltage protection for the electronic components installed in the luminaire. Additional overvoltage protection components are recommended for protection against transients and can be found on the manufacturer’s website at www.bega.com. Prior to installation, it is important to ensure a proper foundation capable of accepting a maximum pressure load of 3,000 kg (~30 kN) is provided by the customer. The luminaire housing must be firmly concreted in to achieve stability.
Product Usage Instructions
- Ensure the proper foundation capable of accepting the maximum pressure load is provided.
- Firmly concrete the luminaire housing in place.
- Connect the appropriate lamp module to the luminaire:
- For 77 961 K2: LED-0340/827, 2700 K, CRI > 80, 1345 lm, 983 lm, 98.3 lm/W
- For 77 961 R K2: LED-0340/827, 2700 K, CRI > 80, 1345 lm, 817 lm, 81.7 lm/W
- For 77 961 K4: LED-0340/827, 2700 K, CRI > 80, 1345 lm, 817 lm, 81.7 lm/W
Note: The remaining module designations (77 961 K3, 77 961 R K3, and 77 961 K4) do not have specified specifications available.
DIMENSION
Instructions for use
Application
Floodlight with symmetrical light distribution for flush-mounting installation
in compacted surfaces, paths and open areas. Drive-over luminaire for vehicles
with pneumatic tires.
Please note: Luminaire must not be used for installation in road lanes,
where the fixture is exposed to a horizontal strain due to braking,
acceleration, and change of direction. For walk-through public areas, we
recommend skid-blocking glass – see accessories.
Product Description
- Cover ring Luminaire housing made of stainless steel and cast stainless steel Steel grade number 1.4301
- Clear safety glass
- Reflector made of pure anodized aluminium
- 1,8 m water-resistant connecting cable
- 07RN8-F 5 G 1@ with implemented water
- stopper and 1.2 m PVC cable conduit
- BEGA Ultimate Driver®
- LED power supply unit
- 220-240 V x 0/50-60 Hz
- DC 176-264 V
- DALI controllable
- A basic isolation exists between power cable and control line
- BEGA Thermal Control®
- Temporary thermal regulation to protect
- temperature-sensitive components without
- switching off the luminaire
- Safety class I
- Protection class IP 68 10 m
- Dust-tight and water pressure tight
- Maximum submersion depth 10 m
- Not suitable for permanent operation under water
- Pressure load 3,000 kg (~30 kN)
- Impact strength IK10
- Protection against mechanical
- impacts < 20 joule
- Maximum surface temperature 25 °C
- (measured according to EN 60598 of ta 15 °C)
- c – Conformity mark
- r – Safety mark
- Weight: 4.8 kg
Safety
The installation and operation of this luminaire are subject to national
safety regulations. Installation and commissioning may only be carried out by
a qualified electrician We recommend fuse protection via a residual current
circuit breaker to be provided by the customer. The manufacturer accepts no
liability for damage caused by improper use or installation. If subsequent
modifications are made to the luminaire, the person responsible for these
modifications shall be considered the manufacturer.
Overvoltage protection
The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547. To achieve an additional protection against e. g. transients, etc. we recommend separate overvoltage protection components. You can find them on our website at www.bega.com.
Notice prior to installation:
- To accept the maximum pressure load of 3,000 kg (~30 kN) a proper foundation must be provided by the customer.
- The pressure load is transferred to the foundation by this luminaire housing provided at site.
- The foundation must be carried out on firm subgrade.
- In order to obtain a firm stableness, the luminaire housing must be firmly concreted in.
Installation
- Position luminaire housing on the foundation (as described above) and fix it with enclosed or any other suitable fixing material.
- The electrical connection must be carried out with matching protection class and safety class with suitable connection terminals (not included in the scope of delivery) at the luminaire power supply cable.
- We recommend that you use distribution box 70 730 or 71 053 for this purpose.
- Ensure that the connection cable is correctly connected.
- Make the mains connection to the brown (L), blue (N) and green-yellow wires (1).
- The control cables are connected via the two wires marked DALI.
- If these wires are not assigned, the luminaire will work with full light output.
- After finishing the ground works remove protection foil from the luminaire cover.
Cleaning · Maintenance
- After installation, the luminaire should first be cleaned. Building dust, residues from contact adhesives, paint splashes and rust film must be completely removed. Never use high pressure cleaners and cleaning implements made of normal steel, steel brushes or steel wool because they cause extraneous rust to form.
- When using stainless steel cleaners, please read the directions carefully.
- Cleaning agents containing hydrochloric acid and chlorides should never be used.
- We recommend cleaning the luminaires regularly.
Lamp
- Module connected wattage 8 W
- Luminaire connected wattage 10 W
- Rated temperature ta = 25 °C
- Ambient temperature ta max = 45 °C
- When installed in heat-insulating
- material ta max = 25 °C
77 961 K2
- Module designation LED-0340/827
- Colour temperature 2700 K
- Colour rendering index CRI > 80
- Module luminous flux 1345 lm
- Luminaire luminous flux 983 lm
- Luminaire luminous efficiency 98,3 lm / W
77 961 R K2
- Module designation LED-0340/827
- Colour temperature 2700 K
- Colour rendering index CRI > 80
- Module luminous flux 1345 lm
- Luminaire luminous flux 817 lm
- Luminaire luminous efficiency 81,7 lm / W
77 961 K3
- Module designation LED-0340/830
- Colour temperature 3000 K
- Colour rendering index CRI > 80
- Module luminous flux 1395 lm
- Luminaire luminous flux 1020 lm
- Luminaire luminous efficiency 102 lm / W
77 961 R K3
- Module designation LED-0340/830
- Colour temperature 3000 K
- Colour rendering index CRI > 80
- Module luminous flux 1395 lm
- Luminaire luminous flux 849 lm
- Luminaire luminous efficiency 84,9 lm / W
77 961 K4
- Module designation LED-0340/840
- Colour temperature 4000 K
- Colour rendering index CRI > 80
- Module luminous flux 1415 lm
- Luminaire luminous flux 1035 lm
- Luminaire luminous efficiency 103,5 lm / W
77 961 R K4
- Module designation LED-0340/840
- Colour temperature 4000 K
- Colour rendering index CRI > 80
- Module luminous flux 1415 lm
- Luminaire luminous flux 861 lm
- Luminaire luminous efficiency 86,1 lm / W
Please note: Do not remove the desiccant bag from the luminaire housing. It is needed to remove residual moisture.
Replacing the LED module
- The designation of the LED module is noted on a label in the luminaire.
- The light colour and light output of BEGA replacement modules correspond to those of the modules originally fitted. The modulecan be replaced by qualified persons using standard tools.
- Disconnect the electrical installation.
- The LED module of this luminaire may only be exchanged by the manufacturer or by one of his assigned service technicians or a comparable qualified person.
- Clean dirt and deposits from key openings of screw head.
- Do not use a high pressure cleaner.
- Open the luminaire and clean.
- Use only solvent-free cleaners.
- The luminaire housing must be completely clean and absolutely dry.
- Replace LED module.
- Please follow the installation instructions for the
- LED module.
- Check all screws and threads thoroughly and grease them.
- Check the gasket and replace, if necessary.
- A broken glass must be replaced. Insert glass with gasket with stepped side turned upward into the luminaire housing.
- Make sure that the glass is correctly positioned in the gasket bed.
- Place trim ring onto glass step and tighten screws crosswise.
- Torque = 4 Nm.
Accessories
14000645R Skid-blocking glass BEGA skid-blocking glass with the highest rating R 13 according to DIN 51130 can be used without restriction for all public areas.Abrasion resistance according to EN ISO 10545-7 Class 3
Distribution box for installation in soil
- 70 730 Distribution box with 7 cable entries Connection terminals 5 x 4@
- 71 053 Distribution box with 10 cable entries Connection terminals 6 x 16@
A separate instructions for use can be provided upon request.
Spares
- Spare glass 14 000 645
- Spare glass skid blocking 14 000 645 R
- LED power supply unit DEV-0340/700
- LED module 2700 K LED-0340/827
- LED module 3000 K LED-0340/830
- LED module 4000 K LED-0340/840
- Reflector 76 001 214
- Gasket 83 001 737
CONTACT
- BEGA Gantenbrink-Leuchten KG
- Postfach 31 60
- 58689 Menden
- info@bega.com.