Instructions for use

Application

Wall luminaire with two-sided light output.
For illumination and design tasks in architecture.
The light directed downwards is intended to illuminate the wall and the horizontal surface in front of it.
The light directed upwards is intended to illuminate the wall and ceiling surfaces.

Product description

Luminaire made of aluminium alloy, aluminium and stainless steel
BEGA Unidure® coating technology
Colour graphite, silver or white
Matt safety glass
Reflector surface made of pure aluminium
Mounting plate with 2 fixing holes ø 4.4 mm · 62 x 95 mm spacing
2 cable entries for through-wiring of mains supply cable ø 7-12 mm
Connecting terminal 2.5◻ with plug connection
Earth conductor connection
LED power supply unit
220-240 V ≂ 0/50-60 Hz
BEGA Thermal Control®
Temporary thermal regulation to protect temperature-sensitive components without switching off the luminaire
Safety class I
Protection class IP 65
Dust-tight and protection against water jets
Impact strength IK05
Protection against mechanical impacts < 0.7 joule
– Safety mark
****– Conformity mark
Weight: 2.7 kg
This product contains light sources of energy efficiency class(es) C, D

Safety

The installation and operation of this luminaire are subject to national safety regulations.
Installation and commissioning may only be carried out by a qualified electrician.
The manufacturer accepts no liability for damage caused by improper use or installation.
If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.

Overvoltage protection

The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547.
To achieve an additional protection against e. g. transients, etc. we recommend separate overvoltage protection components.
You can find them on our website at www.bega.com.

Lamp

Module connected wattage 16.8 W
Luminaire connected wattage 19 W
Rated temperature ta = 25 °C
Ambient temperature ta max = 50 °C

24 617 K3

Module designation 2x LED-1145/830
Colour temperature 3000 K
Colour rendering index CRI > 80
Module luminous flux 2960 lm
Luminaire luminous flux 2090 lm
Luminaire luminous efficiency 110 lm / W

24 617 K4

Module designation 2x LED-1145/840
Colour temperature 4000 K
Colour rendering index CRI > 80
Module luminous flux 3110 lm
Luminaire luminous flux 2196 lm
Luminaire luminous efficiency 115,6 lm / W

Lighting technology
Wall luminaire with broad spread light distribution.
Half beam angle of the light distribution in both half spaces 72°.

Installation

LED are high-quality electronic components!
Please avoid touching the light output opening of the LED directly during installation or relamping.
Undo hexagon socket head screws (wrench size 3 mm) up to the stop and disassemble the mounting plate.
Pass the power connecting cable through the cable entry in the mounting plate.
Fix the mounting plate with enclosed or any other suitable fixing material onto the mounting surface.
Make earth conductor connection and electrical connection to the connecting terminal (plug connection).
Push plug into coupler as far as it will go.
Place luminaire housing onto the mounting plate and fix it.
Make sure that gasket is positioned correctly.

Please note:
Do not remove the desiccant bag from the luminaire housing.
It is needed to remove residual moisture.

Cleaning · Maintenance

Clean luminaire regularly with solvent-free cleansers from dirt and deposits.
Do not use high pressure cleaners.
Replacing the LED module
The designation of the LED module is noted on a label in the luminaire.
The light colour and light output of BEGA replacement modules correspond to those of the modules originally fitted.
The module can be replaced by qualified persons using standard tools.
Disconnect the system and open the luminaire.
Please follow the installation instructions for the LED module.
Inspect and, if necessary, replace the luminaire gaskets.
Defective glass must be replaced.
Close the luminaire.

Spares

LED power supply unit DEV-0475/500
LED module 3000 K LED-1145/830
LED module 4000 K LED-1145/840
Reflector 76 001 976
Gasket mounting box 83 002 074
Gasket housing 83 002 075

BEGA Gantenbrink-Leuchten KG
Postfach 31 60
58689 Menden
info@bega.com
www.bega.com

Documents / Resources

| BEGA 24617K3 Wall Luminaire [pdf] Instruction Manual
24617K3 Wall Luminaire, 24617K3, Wall Luminaire, Luminaire
---|---

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals