Pelgrim IKA7072 Induction Hob Instruction Manual
- June 12, 2024
- Pelgrim
Table of Contents
IKA7072 Induction Hob
Installation instructions
Induction hobs
The fitting of the appliance should only be carried out by a registered and qualified installer. Please read the safety regulations.
Preparations for installation
Pictograms used
Important information
Electrical connection
This appliance must be earthed
The equipment should not be connected to the network via a multi-plug socket
or extension
lead, as the safe use of the equipment can then not be guaranteed.
Free space around appliance
A (mm)
|
C (mm)
|
D (mm)
---|---|---
min. 650
|
min. 450
|
min. 40
Connected load
|
A (mm)
|
B (mm)
|
C (mm)
|
D (mm)
---|---|---|---|---
IKA7072
|
700
|
520
|
49
|
53
IKA7084ANT
|
800
|
522
|
49
|
53
IKA7085
|
800
|
520
|
49
|
53
IKA7093
|
900
|
520
|
49
|
53
IKA7094
|
900
|
520
|
49
|
53
|
L1 (W)
|
L2 (W)
|
L3 (W)
|
Total load (W)
---|---|---|---|---
IKA7072
|
3700
|
3700
|
–
|
7400
IKA7084ANT
|
3700
|
3000
|
–
|
7400
IKA7085
|
3700
|
3000
|
–
|
7400
IKA7093
|
3700
|
3000
|
3700
|
10400
IKA7094
|
3700
|
3000
|
–
|
7400
|
A (mm)
|
B (mm)
|
C (mm)
|
D (mm)
|
E (mm)
---|---|---|---|---|---
IKA7072
|
560
|
600
|
490
|
50
|
56
IKA7084ANT
|
750
|
600
|
490
|
50
|
56
IKA7085
|
750
|
600
|
490
|
50
|
56
IKA7093
|
810
|
600
|
490
|
50
|
56
IKA7094
|
810
|
600
|
490
|
50
|
56
Placing sealing tape
Electrical connection
This connection is for IKA7072, IKA7084ANT, IKA7085 and IKA7094.
Only for IKA7093!
Consult the wiring diagrams on the back of the appliance/Make the required connections on the connecting block.
You can find the most recent version of the installation instructions on our website.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>