Recessed ceiling and wall luminaire for indoor useInstructions for use
Application
Recessed ceiling and wall luminaire · indoor luminaire with hand-blown opal
glass, satin matt and metal housing for connection to external LED power
supply unit.
They are ideal for places where a soft and uniform lighting distribution is
required. For installation into ceilings or walls with a shallow depth in
interior areas.
Product description
Luminaire housing made of metal Opal glass, satin matt, with screw neck
Silicone gasket
Fixing is achieved by using two adjustable wedge-shaped claws 2 connecting
cables with strain relief and plug connector system for BEGA power supply
unit, on/off or DALI
Safety class III Conformity mark
Weight: 1.6 kg
This product contains light sources of energy efficiency class(es) D
Safety
The installation and operation of this luminaire are subject to national
safety regulations.
Installation and commissioning may only be carried out by a qualified
electrician.
The manufacturer accepts no liability for damage caused by improper use or
installation. If subsequent modifications are made to the luminaire, the
person responsible for these modifications shall be considered the
manufacturer.
Overvoltage protection
The electronic components installed in the luminaire are protected against
overvoltage in accordance with DIN EN 61547.
To achieve an additional protection against e. g. transients, etc. we
recommend separate overvoltage protection components.
You can find them on our website at www.bega.com.
Lamp
Module connected wattage | 9.5 W |
---|---|
Luminaire connected wattage | 12 W |
Rated temperature | ta = 25 °C |
Ambient temperature | ta max = 45 °C |
When installed in heat-insulating material | ta max = 25 °C |
50 635 K3
Module designation | LED-0328/930 |
---|---|
Colour temperature | 3000 K |
Colour rendering index | CRI > 90 |
Module luminous flux | 1600 lm |
Luminaire luminous flux | 1268 lm |
Luminaire luminous efficiency | 105,7 lm / W |
Installation
LED are high-quality electronic components! Please avoid touching the light output opening of the LED directly during installation or relamping.
A separate power supply unit is required to operate the luminaire.
For connection to external LED power supply unit – accessory 13 176 or 13 203–
the luminaire is equipped with two 2-pin connectors.
Observe the instructions for use for LED power supply units.
Please note:
The black marked connector is not used to connect to the power supply unit 13
176 on/of The recessed opening is covered by the frame of the luminaire
housing.
Fixing of the luminaire in the structure is achieved by using two adjustable
wedgeshaped claws.
Installation in solid walls or ceilings
To accommodate the luminaire and the external power supply unit we recommend
using the installation housing – accessory 13 025 -.
Installation in suspended ceilings
A recessed opening of ø 142 mm with a minimum installation depth of 45 mm is
required.
The lateral clearance from the luminaire housing to parts of the building must
be at least 50 mm.
The claws grip behind the panel.
The minimum thickness of the panel must be 3 mm and the maximum thickness 25
mm.
A panel with less than 5 mm thickness must be reinforced on the reverse side.
Open luminaire: Remove glass from luminaire housing by turning it counter-
clockwise.
Connect plug part of the luminaire with power supply unit.
Connect to the LED power supply unit.
Guide the LED power supply unit through the opening in the ceiling and
position it on the suspended ceiling.
Push luminaire housing into the ceiling cut-out.
Tighten evenly screws of claw fasteners.
Screw glass with gasket into luminaire housing.
Make sure that gasket is positioned correctly.
Cleaning · Maintenance
Clean luminaire regularly with solvent-free cleansers from dirt.
Replacing the LED module
The designation of the LED module is noted on a label in the luminaire.
The light colour and light output of BEGA replacement modules correspond to
those of the modules originally fitted.
The module can be replaced by qualified persons using standard tools.
Disconnect the system and open the luminaire.
Please follow the installation instructions for the LED module.
Inspect and, if necessary, replace the luminaire gaskets.
Defective glass must be replaced.
Close the luminaire.
Accessories
Power supply units for LED luminaires 220-240 V · 0/50-60 Hz with strain
relief and plug connector system.
13 176 Power supply unit on/off
13 203 Power supply unit DALI
The power supply units are only suitable for the operation of one LED
luminaire.
13 025 Installation housing
For the accessories a separate instructions for use can be provided upon
request.
Spares
Spare glass | 11 003 469 .0B 1RG |
---|---|
LED module 3000 K | LED-0328/930 |
LED cover | 75 003 495 |
BEGA Gantenbrink-Leuchten KG ·
Postfach 31 60 ·
58689 Menden ·
info@bega.com ·
www.bega.com
Documents / Resources
| BEGA
50635 LED Recessed Ceiling and Wall
Luminaire
[pdf] Instruction Manual
50635, 50635K3, 50635 LED Recessed Ceiling and Wall Luminaire, LED Recessed
Ceiling and Wall Luminaire, Recessed Ceiling and Wall Luminaire, Ceiling and
Wall Luminaire, Wall Luminaire, Luminaire
---|---
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>