BEGA 50713.2 LED Recessed Ceiling Luminaire
DIMENSIONS
Instructions for use
Application
- Pivoting recessed ceiling luminaire · indoor luminaire partially satin matt crystal glass inside and aluminium alloy housing.
- Efficient luminaires for adjustable, brilliant light in the residential living space and for use in many other ranges of interior illumination.
- For installation into ceilings with a shallow depth in interior areas.
Product Description
- Recessed ceiling luminaire »ACCENTA VARIO«
- Die-cast aluminium housing
- Crystal glass, partially satin matt inside
- Reflector made of pure, high-gloss anodized aluminium
- Ceiling frame ring made of stainless steel
- Recessed opening ø 95 mm
- Required installation depth 60 mm
- Fixing is achieved by using 2 adjustable claws
- External LED power supply unit 220-240 V 0/50-60 Hz
- Safety class II
- – Safety mark
- – Conformity mark
- Weight: 0.6 kg
- This product contains light sources of energy efficiency class(es) E
Safety
- The installation and operation of this luminaire are subject to national safety regulations.
- Installation and commissioning may only be carried out by a qualified electrician.
- The manufacturer accepts no liability for damage caused by improper use or installation.
- If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.
Overvoltage protection
- The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547.
- To achieve an additional protection against e. g. transients, etc. we recommend separate overvoltage protection components.
- You can find them on our website at www.bega.com.
Lamp
- Module connected wattage 8.5 W
- Luminaire connected wattage 10.4 W
- Rated temperature ta = 25 °C
- Ambient temperature ta max = 45 °C
- When installed in heat-insulating material ta max = 25 °C
50 713.2 K27
- Module designation LED-0923/927
- Colour temperature 2700 K
- Colour rendering index CRI > 90
- Module luminous flux 1155 lm
- Luminaire luminous flux 581 lm
- Luminaire luminous efficiency 55,9 lm / W
50 713.2 K3
- Module designation LED-0923/930
- Colour temperature 3000 K
- Colour rendering index CRI > 90
- Module luminous flux 1200 lm
- Luminaire luminous flux 604 lm
- Luminaire luminous efficiency 58,1 lm / W
Installation
- The recessed opening will be covered by the attachement of the installation ring.
- Fixing of the luminaire is achieved by using 2 adjustable claws.
- LEDs are high-quality electronic components!
- Please avoid touching them directly during installation or relamping.
Installation into false ceilings
- A recessed opening of Ø 95 mm is necessary to accept the luminaire housing. Free space depth min. 60 mm.
- The claws catch the panel from the reverse side.
- If minimum thickness of the panel is less than 3 mm it must be reinforced from the reverse side.
- Maximum thickness of the panel must be no more than 20 mm.
- The notch in the installation ring indicates the direction of maximum pivoting range (35°) of the luminaire housing.
- Remove glass with reflector from luminaire housing by turning counter-clockwise.
- The electrical connection must be made on site in the appropriate safety class on the LED power supply unit connecting cable. A distribution box must be used.
- Ensure the correct assignment of the connecting cable. Establish the mains connection on the brown (L) and blue (N) wires.
- Push external LED-power supply unit and luminaire housing into ceiling cut-out.
- Hand-tight screws of claw fasteners evenly.
- Insert glass with mounted reflector by turning it clockwise into luminaire housing.
- Make sure that gasket is positioned correctly.
- Mount ceiling frame ring (magnetic) onto installation ring of the housing.
Cleaning · Maintenance
- Clean luminaire regularly with solvent-free cleansers from dirt.
- Defective glass must be replaced.
Replacement of the LED module
- The designation of the LED module is noted on a label in the luminaire.
- The light colour and light output of BEGA replacement modules correspond to those of the modules originally fitted. The module can be replaced by qualified persons using standard tools.
- Disconnect from main supply.
- Remove glass with reflector from housing by turning it counter-clockwise.
- Pull ceiling frame ring off the installation ring of the pivoting housing.
- Please follow the installation instructions for the LED module.
- Check gasket. Screw in glass with mounted reflector by turning it clockwise into luminaire housing.
- Mount ceiling frame ring onto installation ring of the housing.
- Defective glass must be replaced.
Spares
- LED power supply unit DEV-0279/250
- LED module 2700 K LED-0923/927
- LED module 3000 K LED-0923/930
- Trim ring 72 009 802 L
- Reflector 76 001 209
BEGA Gantenbrink-Leuchten KG
- Postfach 31 60 · 58689 Menden
- info@bega.com