BEGA 50713.2 LED Recessed Ceiling Luminaire Instruction Manual

June 12, 2024
BEGA

BEGA 50713.2 LED Recessed Ceiling Luminaire

DIMENSIONS

BEGA-50713-2-LED-Recessed-Ceiling-Luminaire-FIG-1

Instructions for use

Application

  • Pivoting recessed ceiling luminaire · indoor luminaire partially satin matt crystal glass inside and aluminium alloy housing.
  • Efficient luminaires for adjustable, brilliant light in the residential living space and for use in many other ranges of interior illumination.
  • For installation into ceilings with a shallow depth in interior areas.

Product Description

  • Recessed ceiling luminaire »ACCENTA VARIO«
  • Die-cast aluminium housing
  • Crystal glass, partially satin matt inside
  • Reflector made of pure, high-gloss anodized aluminium
  • Ceiling frame ring made of stainless steel
  • Recessed opening ø 95 mm
  • Required installation depth 60 mm
  • Fixing is achieved by using 2 adjustable claws
  • External LED power supply unit 220-240 V 0/50-60 Hz
  • Safety class II
  •  – Safety mark
  •  – Conformity mark
  • Weight: 0.6 kg
  • This product contains light sources of energy efficiency class(es) E

Safety

  • The installation and operation of this luminaire are subject to national safety regulations.
  • Installation and commissioning may only be carried out by a qualified electrician.
  • The manufacturer accepts no liability for damage caused by improper use or installation.
  • If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.

Overvoltage protection

  • The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547.
  • To achieve an additional protection against e. g. transients, etc. we recommend separate overvoltage protection components.
  • You can find them on our website at  www.bega.com.

Lamp

  • Module connected wattage 8.5 W
  • Luminaire connected wattage 10.4 W
  • Rated temperature ta = 25 °C
  • Ambient temperature ta max = 45 °C
  • When installed in heat-insulating material ta max = 25 °C

50 713.2 K27

  • Module designation LED-0923/927
  • Colour temperature 2700 K
  • Colour rendering index CRI > 90
  • Module luminous flux 1155 lm
  • Luminaire luminous flux 581 lm
  • Luminaire luminous efficiency 55,9 lm / W

50 713.2 K3

  • Module designation LED-0923/930
  • Colour temperature 3000 K
  • Colour rendering index CRI > 90
  • Module luminous flux 1200 lm
  • Luminaire luminous flux 604 lm
  • Luminaire luminous efficiency 58,1 lm / W

Installation

  • The recessed opening will be covered by the attachement of the installation ring.
  • Fixing of the luminaire is achieved by using 2 adjustable claws.
  • LEDs are high-quality electronic components!
  • Please avoid touching them directly during installation or relamping.

Installation into false ceilings

  • A recessed opening of Ø 95 mm is necessary to accept the luminaire housing. Free space depth min. 60 mm.
  • The claws catch the panel from the reverse side.
  • If minimum thickness of the panel is less than 3 mm it must be reinforced from the reverse side.
  • Maximum thickness of the panel must be no more than 20 mm.
  • The notch in the installation ring indicates the direction of maximum pivoting range (35°) of the luminaire housing.
  • Remove glass with reflector from luminaire housing by turning counter-clockwise.
  • The electrical connection must be made on site in the appropriate safety class on the LED power supply unit connecting cable. A distribution box must be used.
  • Ensure the correct assignment of the connecting cable. Establish the mains connection on the brown (L) and blue (N) wires.
  • Push external LED-power supply unit and luminaire housing into ceiling cut-out.
  • Hand-tight screws of claw fasteners evenly.
  • Insert glass with mounted reflector by turning it clockwise into luminaire housing.
  • Make sure that gasket is positioned correctly.
  • Mount ceiling frame ring (magnetic) onto installation ring of the housing.

Cleaning · Maintenance

  • Clean luminaire regularly with solvent-free cleansers from dirt.
  • Defective glass must be replaced.

Replacement of the LED module

  • The designation of the LED module is noted on a label in the luminaire.
  • The light colour and light output of BEGA replacement modules correspond to those of the modules originally fitted. The module can be replaced by qualified persons using standard tools.
  • Disconnect from main supply.
  • Remove glass with reflector from housing by turning it counter-clockwise.
  • Pull ceiling frame ring off the installation ring of the pivoting housing.
  • Please follow the installation instructions for the LED module.
  • Check gasket. Screw in glass with mounted reflector by turning it clockwise into luminaire housing.
  • Mount ceiling frame ring onto installation ring of the housing.
  • Defective glass must be replaced.

Spares

  • LED power supply unit DEV-0279/250
  • LED module 2700 K LED-0923/927
  • LED module 3000 K LED-0923/930
  • Trim ring 72 009 802 L
  • Reflector 76 001 209

BEGA Gantenbrink-Leuchten KG

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

BEGA User Manuals

Related Manuals