BEGA 51250.1 LED Recessed Ceiling Downlight Instruction Manual
- June 13, 2024
- BEGA
Table of Contents
51 250.1
Recessed ceiling downlight for indoor use
Instructions for use
51250.1 LED Recessed Ceiling Downlight
Application
Recessed ceiling luminaire · indoor luminaire with adjustable wide beam light
distribution.
With external DALI controllable power supply unit for installation into
concrete ceilings or suspended ceilings.
Product description
Recessed ceiling downlights with external PSU
Luminaire made of aluminium alloy, aluminium and stainless steel
Ceiling trim ring made of metal, Colour velvet white
Clear safety glass
Reflector surface made of pure aluminium
Optical silicone lens · BEGA Constant Optics®
Luminaire housing with 2 fixing claws and guide screws
Recessed opening ø 97 mm
Required installation depth 85 mm
1 connecting cable with strain relief and plug connector system for BEGA DALI-
power supply unit
External LED power supply unit 350 mA 220-240 V 0/50-60 Hz DC 176-280 V
DALI controllable
A basic isolation exists between power cable and control line
Safety class II
– Conformity mark
Weight: 0.6 kg
This product contains light sources of energy efficiency class(es) E
Safety
The installation and operation of this luminaire are subject to national
safety regulations.
Installation and commissioning may only be carried out by a qualified
electrician.
The manufacturer accepts no liability for damage caused by improper use or
installation. If subsequent modifications are made to the luminaire, the
person responsible for these modifications shall be considered the
manufacturer.
Overvoltage protection
The electronic components installed in the luminaire are protected against
overvoltage in accordance with DIN EN 61547.
To achieve an additional protection against e. g. transients, etc. we
recommend separate overvoltage protection components.
You can find them on our website at www.bega.com.
Installation
LED are high-quality electronic components!
Please avoid touching the light output opening of the LED directly during
installation or revamping.
The recessed opening is covered by the frame of the luminaire housing.
Fixing of the luminaire in the structure is achieved by using two adjustable
claws.
Installation in concrete ceilings:
To accommodate the luminaire and the external power supply unit we recommend
using the installation housing 10 440.
Installation in suspended ceilings:
A recessed opening of ø 97 mm with a minimum installation depth of 85 mm is
required.
The external power supply unit requires a minimum of 70 mm clearance above the
ceiling.
The claws grip behind the ceiling cladding.
The minimum thickness of the ceiling cladding is 12 mm.
If the thickness is less, and if installation is to be effected in
plasterboard ceilings, the back of the ceiling cladding must be reinforced in
the region of the claws.
The electrical connection must be made on site in the appropriate safety class
on the LED power supply unit connecting cable. A distribution box must be
used.
Ensure the correct assignment of the connecting cable. Establish the mains
connection on the brown (L) and blue (N) wires.
The two connecting terminals marked DA, DA are provided for digital control
purposes.
If these terminals are not assigned, the luminaire will work with full light
output.
Pull cover ring (magnetic) off the installation ring of the pivoting housing.
Connect plug part of the luminaire with power supply unit.
Push external LED power supply unit and luminaire housing into the ceiling
cut-out.
Tighten guide screws.
When tightening the screws, the fixing claws must swivel onto the inside of
the suspended ceiling. The luminaire is fixed.
When undoing the guide screws, the fixing claws swivel back and the luminaire
can be removed.
Adjustment of the direction of radiation:
Undo both hexagon socket head screws and remove transportation lock. Adjust
tilt angle and beam direction of the LED. Tighten latching screw.
Mount the cover ring onto installation ring of the housing (magnetic).
Lamp
Module connected wattage | 3.8 W |
---|---|
Luminaire connected wattage | 5.8 W |
Rated temperature | ta = 25 °C |
Ambient temperature | ta max = 40 °C |
When installed in heat-insulating material | ta max = 25 °C |
51 250.1 K3
Module designation| LED-1164/930
Colour temperature| 3000 K
Colour rendering index| CRI > 90
Module luminous flux| 515 lm
Luminaire luminous flux| 379 lm
Luminaire luminous efficiency| 65,3 lm / W
Light technique
Recessed luminaire with adjustable optical system, 0-30° swivel-mounted and
±180° infinitely rotatable.
Wide beam light distribution.
Half beam angle 16°
The symmetrical light cone can be modified to resemble flat beam light
distribution for special lighting applications by replacing the cover glass.
Cleaning · Maintenance
Clean luminaire regularly with solvent-free cleansers from dirt.
Replacing the LED module
The designation of the LED module is noted on a label in the luminaire.
The light colour and light output of BEGA replacement modules correspond to
those of the modules originally fitted.
The module can be replaced by qualified persons using standard tools.
Disconnect the system and open the luminaire.
Please follow the installation instructions for the LED module.
Inspect and, if necessary, replace the luminaire gaskets.
Defective glass must be replaced.
Close the luminaire.
Accessories
10 440 Installation housing
10 013 Exchangeable lens flat beam
For the accessories a separate instructions for use can be provided upon
request.
Spares
Spare glass| 14 001 565
LED power supply unit| DEV-0434/350
LED module 3000 K| LED-1164/930
Reflector| 76 002 007
BEGA Gantenbrink-Leuchten KG
Technical amendments reserved
Postfach 31 60
58689 Menden
info@bega.com
www.bega.com