BEGA 51213.1 LED Ceiling Luminaire Downlight Instruction Manual

June 13, 2024
BEGA

BEGA 51213.1 LED Ceiling Luminaire Downlight

Product Information

Safety:
The installation and operation of this luminaire are subject to national safety regulations. Installation and commissioning should only be carried out by a qualified electrician. The manufacturer does not accept liability for damage caused by improper use or installation. Any modifications made to the luminaire are the responsibility of the person making the modifications.

Overvoltage Protection:
The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547. For additional protection against transients, it is recommended to use separate overvoltage protection components available on the manufacturer’s website.

Product Specifications:

Lamp Module connected wattage| Luminaire connected wattage| Rated temperature| Ambient temperature
---|---|---|---
30.3 W| 35.3 W| ta| ta
Module designation| Colour temperature| Colour rendering index| Module luminous flux| Luminaire luminous flux| Luminaire luminous efficiency
LED-0785/927| 2700 K| CRI > 90| 4275 lm| 2927 lm| 82.9 lm / W
LED-0785/930| 3000 K| CRI > 90| 4450 lm| 3047 lm| 86.3 lm / W

Product Usage Instructions:

Installation:
LEDs are high-quality electronic components. Avoid touching the light output opening of the LED directly during installation or relamping.

To ensure a secure connection, follow these steps:

  1. Position the luminaire housing precisely in relation to the mounting plate.
  2. Make sure the vertical bar inside the luminaire housing aligns with the mounting hole on the long bar of the mounting plate.
  3. Press the luminaire housing firmly against the mounting plate and turn it clockwise until it stops.

To open the luminaire, unscrew the glass from the luminaire housing by turning it counter-clockwise. To prevent the luminaire from turning on the mounting plate, hold the luminaire housing in place with one hand.

Replacement of the LED module:
The designation of the LED module is noted on a label in the luminaire. The replacement modules have the same light color and light output as the original modules. Qualified persons can replace the module using standard tools. Follow these steps:

  1. Disconnect the system and open the luminaire.
  2. Follow the installation instructions for the LED module.
  3. Replace any defective glass.
  4. Close the luminaire.

Ceiling luminaire · downlight for indoor use

BEGA-51213.1-LED-Ceiling-Luminaire-Downlight-01

Instructions for use

  • Application
  • Ceiling luminaire downlight · indoor luminaire with symmetrical wide beam light distribution.
  • Product description
  • Aluminium alloy housing,
  • finish Colour velvet white
  • Crystal glass, partially satin matt, with screw neck
  • Light-diffusing silicone lens
  • Reflector made of pure anodised aluminium
  • 2 mounting holes ø 4.5 mm
  • Distance apart 153 mm
  • Connecting terminals 2.5@
  • Earth conductor connection
  • LED power supply unit
  • 220-240 V x 0/50-60 Hz
  • DC 176-276 V
  • During DC operation the LED power is reduced to 15 %
  • DALI-controllable
  • Number of DALI addresses: 1
  • Basic insulation is provided between the mains and control cables
  • BEGA Thermal Control®
  • Temporary thermal regulation to protect temperature-sensitive components without switching off the luminaire
  • Safety class I
  • Impact strength IK06
  • Protection against mechanical
  • impacts < 1 joule
  • c  – Conformity mark
  • Weight: 3.1 kg

This product contains light sources of energy efficiency class(es) E

Safety

  • The installation and operation of this luminaire are subject to national safety regulations.
  • Installation and commissioning may only be carried out by a qualified electrician.
  • The manufacturer accepts no liability for damage caused by improper use or installation.
  • If subsequent modifications are made to  the luminaire, the person responsible for these modifications shall be considered the manufacturer.

Overvoltage protection

  • The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547.
  • To achieve an additional protection against e. g. transients, etc. we recommend separate overvoltage protection components.
  • You can find them on our website at www.bega.com.

Lighting technology

Half beam angle 49°

Lamp

  • Module connected wattage 30.3 W
  • Luminaire connected wattage 35.3 W
  • Rated temperature ta = 25 °C
  • Ambient temperature ta max = 35 °C

51 213.1 K27

  • Module designation LED-0785/927
  • Colour temperature 2700 K
  • Colour rendering index CRI > 90
  • Module luminous flux 4275 lm
  • Luminaire luminous flux 2927 lm
  • Luminaire luminous efficiency 82,9 lm / W

51 213.1 K3

  • Module designation LED-0785/930
  • Colour temperature 3000 K
  • Colour rendering index CRI > 90
  • Module luminous flux 4450 lm
  • Luminaire luminous flux 3047 lm
  • Luminaire luminous efficiency 86,3 lm / W

Installation

  • LED are high-quality electronic components! Please avoid touching the light output opening of the LED directly during installation or relamping.
  • Remove mounting plate from the luminaire housing.
  • Unplug the earth conductor connection (plug contact).

Please note:

  • If the luminaire is to be mounted onto a metallic, electroconductive surface, it is mandatory to make sure that the mounting surface is connected conductive to the earth conductor of the luminaire!
  • Lead the power connecting cable through the mounting plate.
  • Fix the mounting plate with enclosed or any other suitable fixing material onto the mounting surface.
  • Establish the earth conductor connection on the earthing screw (1) of the mounting plate. Establish the earth conductor connection to the luminaire housing (plug contact).
  • Ensure the correct assignment of the connecting cable. Establish the mains connection on the brown (L) and blue (N) wires. The two connecting terminals marked DA, DA are provided for digital control purposes.
  • If these terminals are not assigned, the luminaire will work with full light output.BEGA-51213.1-LED-Ceiling-Luminaire-Downlight-02

IMPORTANT:

  • To ensure secure connection, the luminaire housing must be positioned precisely in relation to the mounting plate.
  • Make sure that the vertical bar inside the luminaire housing is positioned precisely in the area of the mounting hole on the long bar of the mounting plate.
  • Press the luminaire housing firmly against the mounting plate and turn it clockwise firmly against the stop.

Open luminaire:

  • Unscrew glass from luminaire housing by turning it counter-clockwise.
  • To prevent the luminaire from turning on the mounting plate, hold the luminaire housing in place with one hand.

Cleaning · Maintenance

Clean luminaire regularly with solvent-free cleansers from dirt.

Replacement of the LED module

  • The designation of the LED module is noted on a label in the luminaire.
  • The light colour and light output of BEGA replacement modules correspond to those of the modules originally fitted.
  • The module can be replaced by qualified persons using standard tools.
  • Disconnect the system and open the luminaire. Please follow the installation instructions for the LED module.
  • Defective glass must be replaced.
  • Close the luminaire.

Spares

  • Spare glass 11 003 451 10M RG
  • LED power supply unit DEV-0144/600i
  • LED module 2700 K LED-0785/927
  • LED module 3000 K LED-0785/930
  • Reflector 76 001 786 M

BEGA Gantenbrink-Leuchten KG · Postfach 31 60 · 58689 Menden · [email protected] · www.bega.com

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

BEGA User Manuals

Related Manuals