BEGA 23256.3K3 Wall Luminaire Instruction Manual
- June 13, 2024
- BEGA
Table of Contents
BEGA 23256.3K3 Wall Luminaire
Product Information
This product is a luminaire with the following features:
- Insulating housing with cable entry for earth conductor connection
- LED power supply unit: 220-240 V x 0/50-60 Hz DC 176-280 V
- Safety class I
- Protection class IP 44 (protected against granular foreign bodies up to 1 mm and splash water)
- Impact strength IK02
- Weight: 2.1 kg
- Contains light sources of energy efficiency class(es) D
Product Usage Instructions
Safety Precautions:
- The installation and operation of this luminaire must comply with national safety regulations.
- Installation and commissioning should only be done by a qualified electrician.
- The manufacturer is not liable for damage caused by improper use or installation.
- If modifications are made to the luminaire, the person responsible for these modifications will be considered the manufacturer.
Overvoltage Protection:
The electronic components installed in the luminaire are protected against overvoltage according to DIN EN 61547. For additional protection against transients, it is recommended to use separate overvoltage protection components available on the manufacturer’s website at www.bega.com.
Lamp Specifications:
- Lamp Module connected wattage: 13.4 W
- Luminaire connected wattage: 15.5 W
- Rated temperature: 23 256.3 K3
- Module designation: 2x LED-0425/930
- Colour temperature: 3000 K
- Colour rendering index (CRI): > 90
- Module luminous flux: 2210 lm
- Luminaire luminous flux: 1643 lm
- Luminaire luminous efficiency: 106 lm/W
Installation Instructions:
When mounting and dismantling, maintain a minimum distance of 350 mm between
the removable cap and the wall.
To open the luminaire, loosen the knob, remove the cap and glass.
Drill mounting holes into the mounting surface with a spacing of 460 mm. For
the mains supply connection, open the insulation housing by pulling it open
and strip the mains supply cable by a maximum of 15 mm. Then lead the cable
into the insulation housing as shown in the provided sketch.
Instructions for use
Application
Wall luminaire · indoor luminaire made of hand-blown opal glass and metal
housing, for all lighting tasks in interior applications.
They are ideal for places where a soft and uniform lighting distribution is
required. Luminaire with a high protection class.
DIMENSION
Product Description
- Luminaire made of Aluminium, finish Chrome
- Hand-blown opal glass
- 2 elongated fixing holes
- Width 6 mm · 460 mm spacing
- Insulating housing with cable entry for mains supply cable up to ø 10,5 mm, max. 3 x 1,5@
- Connection terminal 2.5@
- Earth conductor connection
- LED power supply unit
- 220-240 V x 0/50-60 Hz
- DC 176-280 V
- BEGA Thermal Switch®
- Temporary thermal shutdown to protect temperature-sensitive components
- Safety class I
- Protection class IP 44
- Protected against granular foreign bodies
- ≥ 1 mm and splash water
- Impact strength IK02
- Protection against mechanical impacts < 0.2 joule
- Safety mark
- Conformity mark
- Weight: 2.1 kg
- This product contains light sources of energy efficiency class(es) D
Safety
The installation and operation of this luminaire are subject to national
safety regulations. Installation and commissioning may only be carried out by
a qualified electrician.
The manufacturer accepts no liability for damage caused by improper use or
installation. If subsequent modifications are made to the luminaire, the
person responsible for these modifications shall be considered the
manufacturer.
Overvoltage protection
- The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547.
- To achieve an additional protection against e. g. transients, etc. we recommend separate overvoltage protection components.
- You can find them on our website at www.bega.com.
FEATURES
Lamp
- Module connected wattage 13.4 W
- Luminaire connected wattage 15.5 W
- Rated temperature ta = 25 °C
- Ambient temperature ta max = 45 °C
23 256.3 K3
- Module designation 2x LED-0425/930
- Colour temperature 3000 K
- Colour rendering index CRI > 90
- Module luminous flux 2210 lm
- Luminaire luminous flux * 1643 lm
- Luminaire luminous efficiency * 106 lm / W
preliminary data
Insulation housing
Installation
- For mounting and dismantling please keep a minimum distance of 350 mm between the removable cap and the wall.
- LEDs are high-quality electronic components! Please avoid touching the light output opening of the LED directly during installation or relamping.
Open luminaire:
- Loosen knob, remove cap and glass.
- Drill mounting holes into the mounting surface – spacing 460 mm.
- For the mains supply connecting open the insulation housing – pull open – strip mains supply cable max. 15 mm and lead it into the insulation housing – see sketch.
- Make earth conductor connection and electrical connection.
- Connect both parts of the insulation housing until they audibly engage.
- The outer coating of the cable has to be fully enclosed by the compression nipple.
- Fix luminaire with enclosed or any other suitable fixing material onto the mounting surface. Place glass into luminaire housing, close luminaire with the cap and screw in knob into the cap.
Replacement of the LED module
- The designation of the LED module is noted on a label in the luminaire.
- The light colour and light output of BEGA replacement modules correspond to those of the modules originally fitted. The module can be replaced by qualified persons using standard tools.
- Disconnect the system.
- Loosen lateral knob, remove cap and take out glass.
- Please follow the installation instructions for the LED module.
- Defective glass must be replaced.
- Insert glass into luminaire housing, close luminaire with the cap and screw in knob into the cap.
Spares
- Spare glass 11 002 525 .1R G
- LED power supply unit DEV-0136/350
- LED module 3000 K LED-0425/930
- Gasket 83 001 179