BEGA 50093.3K3 LED Wall Luminaire Instruction Manual

June 13, 2024
BEGA

BEGA 50093.3K3 LED Wall Luminaire

BEGA-50093-3K3-LED-Wall-Luminaire-PRODUCT-IMG

Product Information

The product is a wall luminaire made of hand-blown opal glass with a metal housing. It is designed for interior applications and can be used for various lighting tasks. The installation and operation of the luminaire must comply with national safety regulations. Only a qualified electrician should carry out the installation and commissioning. The manufacturer is not liable for any damage caused by improper use or installation. Any modifications to the luminaire should be done by a responsible person. The electronic components in the luminaire are protected against overvoltage according to DIN EN 61547. For additional protection against transients, it is recommended to use separate overvoltage protection components available on the manufacturer’s website. The luminaire uses LED modules with a connected wattage of 7.9W and a rated temperature of 25°C. The ambient temperature should also be kept within 25°C. The colour temperature of the LED module is 3000K, with a colour rendering index (CRI) greater than 90. The module has a luminous flux of 1040 lm, while the luminaire has a luminous flux of 529 lm and a luminous efficiency of 52.9 lm/W. To replace the LED module, refer to the label inside the luminaire for the module designation. The replacement modules from BEGA have the same light colour and output as the original modules. Qualified individuals can replace the module using standard tools. Disconnect the system and open the luminaire following the installation instructions for the LED module. Replace any defective glass and close the luminaire. The product also has spare parts available, including spare glass, LED power supply unit, LED module 3000K, and a shield. Refer to the provided codes for ordering the spares.

Product Usage Instructions

  1. Ensure that the installation and operation of the luminaire comply with national safety regulations.
  2. Only a qualified electrician should install and commission the luminaire.
  3. Visit the manufacturer’s website for separate overvoltage protection components if needed.
  4. Maintain the ambient temperature within 25°C for proper operation.
  5. To replace the LED module, follow these steps:
  6. Disconnect the system and open the luminaire.
  7. Refer to the label inside the luminaire for the LED module designation.
  8. Use standard tools to replace the module.
  9. Follow the installation instructions provided for the LED module.
  10. Replace any defective glass if necessary.
  11. Close the luminaire after completing the replacement.
  12. If you require spare parts, refer to the provided codes for ordering the desired items.

DIMENSIONS

BEGA-50093-3K3-LED-Wall-Luminaire-FIG-1

Instructions for use

Application

  • Enclosed and free-radiating wall luminaire made of hand-blown opal glass, with metal housing, for all lighting tasks in interior applications.

Product Description

  • Metal luminaire housing, finish Chrome
  • Hand-blown opal glass
  • Metal shield, chrome finish 2 mounting holes ø 4.5 mm
  • Distance apart 138 mm
  • 2 cable entries for through-wiring for mains cable up to ø 10.5 mm max. 3 × 1.5@
  • Connection terminal 2.5@
  • Earth conductor connection
  • LED power supply unit 220-240 V 50-60 Hz
  • BEGA Thermal Switch®
  • Temporary thermal shutdown to protect temperature-sensitive components
  • Safety class I
  •  – Safety mark
  •  – Conformity mark
  • Weight: 1.1 kg
  • This product contains light sources of energy efficiency class(es) D

Safety

  • The installation and operation of this luminaire are subject to national safety regulations.
  • Installation and commissioning may only be carried out by a qualified electrician.
  • The manufacturer accepts no liability for damage caused by improper use or installation.
  • If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.

Overvoltage protection

  • The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547.
  • To achieve an additional protection against e. g. transients, etc. we recommend separate overvoltage protection components.
  • You can find them on our website at  www.bega.com.

Lamp

  • Module connected wattage 7.9 W
  • Luminaire connected wattage 10 W
  • Rated temperature ta = 25 °C
  • Ambient temperature ta max = 25 °C

50 093.3 K3

  • Module designation LED-0589/930
  • Colour temperature 3000 K
  • Colour rendering index CRI > 90
  • Module luminous flux 1040 lm
  • Luminaire luminous flux 529 lm
  • Luminaire luminous efficiency 52,9 lm / W

Installation

  • The luminaire must only be operated with the complete protective cover.
  • LED are high-quality electronic components!
  • Please avoid touching the light output opening of the LED directly during installation or relamping.
  • Lead the mains supply cable through the cable entry into the luminaire housing.
  • Fix the mounting plate with enclosed or any other suitable fixing material onto the mounting surface.
  • Be sure to use the gasket rings supplied.
  • Make earth conductor connection.
  • Push silicone sleeves over the lines and make electrical connection.
  • Insert the glass into luminaire housing and fix it by screwing the shield hand-tight clockwise onto the glass.
  • Remove the protective film from the shield.
  • NOTE: If adhesive residue from the protective film remains on the edge of the shield, it can be removed using commercially available lighter fluid.

Cleaning · Maintenance

  • Clean luminaire regularly with solvent-free cleansers from dirt.
  • Defective glass must be replaced.

Replacement of the LED module

  • The designation of the LED module is noted on a label in the luminaire.
  • The light colour and light output of BEGA replacement modules correspond to those of the modules originally fitted.
  • The module can be replaced by qualified persons using standard tools.
  • Disconnect the system and open the luminaire.
  • Please follow the installation instructions for the LED module.
  • Defective glass must be replaced.
  • Close the luminaire.

Spares

  • Spare glass 11 003 166 .1
  • LED power supply unit DEV-0177/350
  • LED module 3000 K LED-0589/930
  • Shield 72 001 007 M

BEGA Gantenbrink-Leuchten KG