BEGA 50602.2 Wall Luminaire
Product Information
Product Description | Luminaire made of Aluminium, finish Stainless steel |
---|---|
Crystal Glasses | Partially satin matt |
Weight | 3.0 kg |
Energy Efficiency Class | E |
Protection Class | I |
Impact Strength | IK06 |
Power Supply Unit | 220-240 V x 0/50-60 Hz DC 170-280 V |
DALI Control | Yes |
Product Usage Instructions
The installation and operation of this luminaire are subject to national safety regulations. Installation and commissioning may only be carried out by a qualified electrician. The manufacturer accepts no liability for damage caused by improper use or installation. If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer. To achieve an additional protection against e.g. transients, etc., it is recommended to use separate overvoltage protection components. Please refer to our website at www.bega.com for more information. During installation or relamping, please avoid touching the light output opening of the LED directly.
DIMENSIONS
Instructions for use
Application
- Wall luminaire · indoor luminaire for brilliant light with crystal glasses and aluminium luminaire housing.
- The luminaire directs the light of the lamps upwards and downwards.
Product Description
- Luminaire made of Aluminium, finish Stainless steel
- Crystal glasses, partially satin matt, with screw neck
- Reflectors made of anodised pure aluminium 2 elongated fixing holes
- Width 5 mm · 76,5 mm spacing
- 1 cable entry for mains supply cable up to ø 10.5 mm max. 5 x 1.5@
- Connecting terminal 2.5@ with plug connection
- Earth conductor connection
- 2-pole connection terminals for digital control
- LED power supply unit 220-240 V 0/50-60 Hz
- DC 170-280 V
- DALI-controllable
- Basic insulation is provided between the mains and control cables
- BEGA Thermal Switch®
- Temporary thermal shutdown to protect temperature-sensitive components
- Safety class I
- Impact strength IK06
- Protection against mechanical impacts < 1 joule
- – Safety mark
- – Conformity mark
- Weight: 3.0 kg
- This product contains light sources of energy efficiency class(es) E
Safety
- The installation and operation of this luminaire are subject to national safety regulations.
- Installation and commissioning may only be carried out by a qualified electrician.
- The manufacturer accepts no liability for damage caused by improper use or installation.
- If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.
Overvoltage protection
- The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547.
- To achieve an additional protection against e. g. transients, etc. we recommend separate overvoltage protection components.
- You can find them on our website at www.bega.com.
Installation
- LED are high-quality electronic components!
- Please avoid touching the light output opening of the LED directly during installation or relamping.
- Undo set screw and lift off luminaire housing.
- Loosen push plug connection and earth connection (plug connection).
- Pass the power connecting cable through the cable entry in the mounting plate.
- Note position of application of the mounting plate “arrow down”.
- Fasten the mounting plate with the supplied fastening material or other suitable fastening material to the installation surface.
- Make earth conductor connection.
- Push silicone sleeves over the lines and make electrical connection to terminal (plug connection).
- The two connecting terminals marked DA, DA are provided for digital control purposes.
- If these terminals are not assigned, the luminaire will work with full light output.
- Make earth conductor connection between luminaire housing and mounting plate.
- Push plug into coupler as far as it will go.
- Install luminaire housing over mounting plate and tighten set screw.
- Note position of application of the luminaire “arrow down”.
Lamp
- Module connected wattage 23 W
- Luminaire connected wattage 26.3 W
- Rated temperature ta = 25 °C
- Ambient temperature ta max = 25 °C
50 602.2 K3
- Module designation 2x LED-0800/930
- Colour temperature 3000 K
- Colour rendering index CRI > 90
- Module luminous flux 3470 lm
- Luminaire luminous flux 2557 lm
- Luminaire luminous efficiency 97,2 lm / W
50 602.2 K4
- Module designation 2x LED-0800/940
- Colour temperature 4000 K
- Colour rendering index CRI > 90
- Module luminous flux 3520 lm
- Luminaire luminous flux 2593 lm
- Luminaire luminous efficiency 98,6 lm / W
Replacement of the LED module
- The designation of the LED module is noted on a label in the luminaire.
- The light colour and light output of BEGA replacement modules correspond to those of the modules originally fitted.
- The module can be replaced by qualified persons using standard tools.
- Disconnect the system and open the luminaire.
- Please follow the installation instructions for the LED module.
- Defective glass must be replaced.
- Close the luminaire.
Cleaning · Maintenance
- Disconnect the electrical installation.
- Unscrew glasses with reflectors from luminaire housing.
- Remove reflector retaining springs.
- Clean luminaire and glasses.
- Defective glass must be replaced.
- Use only solvent-free cleansers.
- Attach reflectors with retaining springs to glasses.
- Screw glasses with reflectors into luminaire housing.
Spares
- Spare glass 11 003 448 10M RG
- LED power supply unit DEV-0365/700
- LED module 3000 K LED-0800/930
- LED module 4000 K LED-0800/940
- Reflector 76 001 796