BEGA 66519 Wall Luminaire Instruction Manual
- June 13, 2024
- BEGA
Table of Contents
BEGA 66519 Wall Luminaire Instruction Manual
BEGA
Wandleuchte
Wall luminaire
Applique
Instructions for use
Application
Wall luminaire with two-sided light output. For illumination and design tasks
in architecture.
The light directed downwards is intended to illuminate the wall and the
horizontal surface in front of it.
The light directed upwards is intended to illuminate the wall and ceiling
surfaces.
Product description
Luminaire made of aluminium alloy, aluminium and stainless steel BEGA Unidure®
coating technology Clear safety glass
Silicone gasket
Reflector made of pure anodised aluminium Mounting plate with 2 fixing
holes ø 4.3 mm · 160 x 14 mm spacing
2 cable entries for through-wiring of mains supply cable ø 7-10.5 mm, max. 5 G
1.5@ Connecting terminal 2.5@ with plug connection
Earth conductor connection BEGA Ultimate Driver®
LED power supply unit 220-240 V x 0/50-60 Hz DC 176-264 V
DALI-controllable
Basic insulation is provided between the mains and control cables
BEGA Thermal Control®
Temporary thermal regulation to protect temperature-sensitive components
without switching off the luminaire
Safety class I Protection class IP 65
Dust-tight and protection against water jets Impact strength IK10
Protection against mechanical impacts < 20 joule
r – Safety mark c – Conformity mark Weight: 5.2 kg
This product contains light sources of energy efficiency classes D
Safety
The installation and operation of this luminaire are subject to national safety regulations.
Installation and commissioning may only be
carried out by a qualified electrician.
The manufacturer accepts no liability for damage caused by improper use or installation.
If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.
Overvoltage protection
The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547.
To achieve an additional protection against
e. g. transients, etc. we recommend separate overvoltage protection components.
You can find them on our website at
Lamp
Module connected wattage 24.6 W
Luminaire connected wattage 26.6 W
Rated temperature ta = 25 °C
Ambient temperature ta max = 50 °C 66 519
K3
Module designation 2x LED-0724/830
Colour temperature 3000 K
Colour rendering index CRI > 80
Module luminous flux 3830 lm
Luminaire luminous flux 2446 lm Luminaire luminous
efficiency 92 lm / W 66 519 K4
Module designation 2x LED-0724/840
Colour temperature 4000 K
Colour rendering index CRI > 80
Module luminous flux 3930 lmLuminaire
luminous flux 2523 lm Luminaire luminous efficiency
94,8 lm / W
Lighting technology
Half beam angle 17°
Installation
The luminaire must only be operated with the complete protective cover.
LED are high-quality electronic components! Please avoid touching the light output opening of the LED directly during installation or relamping.
Undo screw at wall box and remove mounting plate.
Pass the power connecting cable through the cable entry in the mounting plate.
Note position of application of the mounting plate “arrow down”.
Fix the mounting plate with enclosed or any other suitable fixing material
onto the mounting surface.
Make earth conductor connection and electrical connection to the connecting
terminal (plug connection).
Push plug into coupler as far as it will go. Make earth conductor connection
between luminaire and mounting plate.
Note position of application of the luminaire “arrow down”.
Place luminaire housing onto the mounting plate and fix it.
Make sure that gasket is positioned correctly.
Cleaning · Maintenance
Clean luminaire regularly with solvent-free cleansers from dirt and deposits.
Do not use high pressure cleaners.
Please note:
Do not remove the desiccant bag from the luminaire housing.
It is needed to remove residual moisture.
Replacing the LED module
The designation of the LED module is noted on a label in the luminaire.
The light colour and light output of BEGA replacement modules correspond to
those of the modules originally fitted.
The module can be replaced by qualified
persons using standard tools.
Disconnect the system and open the luminaire. Please follow the installation
instructions for the LED module.
Inspect and, if necessary, replace the luminaire gaskets.
Defective glass must be replaced. Close the luminaire.
Spares __
Spare glass 14 000 212
LED power supply unit DEV-0270/700
LED module 3000 K LED-0724/830
LED module 4000 K LED-0724/840
Reflector 76 001 134
Gasket glass 83 000 563
Gasket wall box 83 001 081
Sealing ring 83 001 757
Read More About This Manual & Download PDF: