BEGA 50147.4 Wall Washer for Indoor Use Instruction Manual
- June 13, 2024
- BEGA
Table of Contents
BEGA 50 147.4 Wall Washer for Indoor Use Instruction Manual
Technical amendments reserved
50 147.4
Wall washer for indoor use
Instructions for use
Application
Wall washer · indoor luminaire for the glare free illumination of wall surfaces with the mounting surface being the reflection surface. The light emits upwards and downwards.
Product description
Die-cast aluminium and aluminium housing, finish Colour palladium
Crystal glass, inside matt
Reflector made of pure anodised aluminium
2 mounting holes ø 4.8 mm
Distance apart 265 x 65 mm
2 cable entries for through-wiring of mains supply cable ø 7-10.5 mm, max. 5 G
1.5@
Connection terminal 2.5
Earth conductor connection
2-pole connecting terminal for digital control
LED power supply unit
220-240 V 0/50-60 Hz
DC 196-250 V
DALI-controllable
Basic insulation is provided between the mains and control cables
BEGA Thermal Control®
Temporary thermal regulation to protect temperature-sensitive components
without switching off the luminaire
Safety class I
– Safety mark
– Conformity mark
Weight: 2.5 kg
This product contains light sources of energy efficiency class(es) D
Safety
The installation and operation of this luminaire are subject to national
safety regulations.
Installation and commissioning may only be carried out by a qualified
electrician.
The manufacturer accepts no liability for damage caused by improper use or
installation.
If subsequent modifications are made to the luminaire, the person responsible
for these modifications shall be considered the manufacturer.
Overvoltage protection
The electronic components installed in the luminaire are protected against
overvoltage in accordance with DIN EN 61547.
To achieve an additional protection against e. g. transients, etc. we
recommend separate overvoltage protection components.
You can find them on our website at www.bega.com.
Lamp
Module connected wattage: 32.8 W
Luminaire connected wattage: 37 W
Rated temperature: ta = 25 °C
Ambient temperature: ta max = 30 °C
50 147.4 K3
Module designation: 2x LED-0695/930
Colour temperature: 3000 K
Colour rendering index: CRI > 90
Module luminous flux: 4830 lm
Luminaire luminous flux: 3845 lm
Luminaire luminous efficiency: 103,9 lm / W
50 147.4 K4
Module designation: 2x LED-0695/940
Colour temperature: 4000 K
Colour rendering index: CRI > 90
Module luminous flux: 5020 lm
Luminaire luminous flux: 3990 lm
Luminaire luminous efficiency: 107,8 lm / W
Installation
LED are high-quality electronic components!
Please avoid touching the light output opening of the LED directly during
installation or relamping.
Undo screws and lift off luminaire top.
Loosen earth connection (plug connection) and LED-connection between luminaire
top and luminaire base.
Lead the mains supply cable through the cable entry of the luminaire base.
Note position of application of the luminaire “arrow down”.
Fix luminaire base with enclosed or any other suitable fixing material onto
the mounting surface.
Be sure to use the gasket rings supplied.
Make the earth conductor connection and the electrical connection to the
terminals.
For digital control please use the connecting terminal DA, DA.
In case this terminal is not used the luminaire will be operated at full light
output.
Make earth connection (plug connection) and LED-connection between luminaire
top and luminaire base again.
Install luminaire top part, adjust it and tighten screws evenly.
Cleaning · Maintenance
Clean luminaire regularly with solvent-free cleansers from dirt.
Replacing the LED module
The designation of the LED module is noted on a label in the luminaire.
The light colour and light output of BEGA replacement modules correspond to
those of the modules originally fitted. The replacement can be carried out by
a qualified person using standard tools.
Disconnect the system and open the luminaire.
Uninstall the reflector.
Please follow the installation instructions for the LED module.
Install the reflector. Defective glass must be replaced. Close the luminaire.
Replacement of the glass
Undo screws and lift off luminaire top.
Loosen earth connection (plug connection) and LED-connection between luminaire
top and luminaire base.
Loosen reflector screws, separate earth connection and remove reflector.
Loosen screws of the glass retaining springs and remove glass retaining
springs from the luminaire top.
Remove damaged glass. Insert replacement glass.
Reinstall glass retaining springs and tighten screws on both sides.
Insert reflector into luminaire top part, make earth connection to reflector
and tighten reflector screws (0,6 Nm).
Make earth connection (plug connection) and LED-connection between luminaire
top and luminaire base again.
Install luminaire top part, adjust it and tighten screws evenly.
Spares
Spare glass: 14 001 184 RG
LED power supply unit: DEV-0305/700i
LED module 3000 K: LED-0695/930
LED module 4000 K: LED-0695/940
Reflector: 76 001 511
BEGA Gantenbrink-Leuchten KG · Postfach 31 60 · 58689 Menden · info@bega.com · www.bega.com