BEGA 50349.2 Wall Luminaire for Indoor Use Instruction Manual
- June 13, 2024
- BEGA
Table of Contents
**BEGA 50349.2 Wall Luminaire for Indoor Use Instruction Manual
**
Application
Wall luminaire · indoor luminaire with velvet white luminaire housing and
inside hue.
The light emits upwards and downwards.
Product description
Wall luminaire “STUDIO LINE”
Aluminium luminaire housing,
finish Colour velvet white inside hue aluminium matt
Reflector made of pure anodised aluminium 2 elongated fixing holes
Width 4.5mm · 90 x 38mm spacing
1 cable entry for through-wiring for mains cable
Connecting terminal 2.5@ with plug connection
Earth conductor connection
LED-Module for mains voltage
220-230 V 50/60 Hz
BEGA Thermal Switch®
Temporary thermal shutdown to protect temperature-sensitive components
Safety class I
– Safety mark
– Conformity mark
Weight: 0.65 kg
This product contains light sources of energy efficiency class(es) F
Safety
The installation and operation of this luminaire are subject to national
safety regulations.
Installation and commissioning may only be carried out by a qualified
electrician.
The manufacturer accepts no liability for damage caused by improper use or
installation.
If subsequent modifications are made to the luminaire, the person responsible
for these modifications shall be considered the manufacturer.
Overvoltage protection
The electronic components installed in the luminaire are protected against
overvoltage in accordance with DIN EN 61547.
To achieve an additional protection against e.g. transients, etc. we recommend
separate overvoltage protection components.
You can find them on our website at www.bega.com.
Lamp
Luminaire connected wattage 10 W
Rated temperature ta=25 °C
Ambient temperature ta max=40 °C
50 349.2K3
Module designation LED-0607/930
Colour temperature 3000 K
Colour rendering index Ra > 90
Module luminous flux 940 lm
Luminaire luminous flux 310 lm
Luminaire luminous efficiency 31 lm/W
Installation
LED are high-quality electronic components!
Please avoid touching the light output opening of the LED directly during
installation or relamping.
Undo set screw and lift off luminaire housing.
Loosen LED-connection and earth connection (plug connection).
Pass the power connecting cable
through the cable entry in the mounting plate.
Note position of application of the luminaire “arrow down”.
Fasten the mounting plate with the supplied fastening material or other
suitable fastening material to the installation surface.
Make earth conductor connection.
Push silicone sleeves over the lines and make electrical connection to
terminal (plug connection).
Make earth conductor connection between luminaire housing and mounting plate.
Push LED plug into coupler as fa as it will go.
Install luminaire housing over mounting plate and tighten set screw.
Cleaning · Maintenance
Clean luminaire regularly with solvent-free cleansers from dirt.
Replacing the LED module
The designation of the LED module is noted on a label in the luminaire.
The light colour and light output of BEGA replacement modules correspond to
those of the modules originally fitted. The module can be replaced by
qualified persons using standard tools.
Disconnect the system and open the luminaire.
Please follow the installation instructions for the LED module.
Inspect and, if necessary, replace the luminaire gaskets.
Close the luminaire.
Spares
LED module 3000 K LED-0607/930
BEGA Gantenbrink-Leuchten KG · Postfach 3160 · 58689 Menden · info@bega.com · www.bega.com