Laserliner ClimaHome-Check Digital Hygrometer For Long Term Room Climate Monitoring Instruction Manual

October 29, 2023
Laserliner

Laserliner ClimaHome-Check Digital Hygrometer For Long Term Room Climate

Monitoring

Completely read through the operating instructions, the „Warranty and Additional Information“ booklet as well as the latest information under the internet link at the end of these instructions. Follow the instructions they contain. This document must be kept in a safe place and passed on together with the device.

Function / Application

This digital hygrometer provides information on the ambient temperature and relative humidity. The device saves the minimum and maximum climate values. The fold-out stand/clip with integral magnets allows the device to be placed on tables, attached to objects, or fixed to metal surfaces.

General safety instructions

  • The device must only be used in accordance with its intended purpose and within the scope of the specifications.
  • The structure of the device must not be modified in any way.
  • Do not expose the device to mechanical stress, extreme temperatures or significant vibration

Safety instructions

Dealing with electromagnetic radiation

  • The measuring device complies with electromagnetic compatibility regulations and limit values in accordance with EMC-Directive 2014/30/EU.
  • Local operating restrictions – for example, in hospitals, aircraft, petrol stations or in the vicinity of people with pacemakers –may apply. Electronic devices can potentially cause hazards or interference or be subject to hazards or interference.

Danger – powerful magnetic fields

  • Powerful magnetic fields can adversely affect persons with active medical implants (e.g. pacemaker) as well as electromechanical devices (e.g. magnetic cards, mechanical clocks, precision mechanics, hard disks).
  • With regard to the effect of powerful magnetic fields on persons, the applicable national stipulations and regulations must be complied with such as BGV B11 §14 „electromagnetic fields“ (occupational health and safety – electromagnetic fields) in the Federal Republic of Germany.
  • To avoid interference/disruption, always keep the implant or device  a safe distance of at least 30 cm away from the magnet.

Inserting battery

Open the battery compartment and insert battery according to the symbols. Be sure to pay attention to polarity.

Laserliner ClimaHome-Check Digital Hygrometer For Long Term Room Climate
Monitoring 1

The device has been optimised for use in fixed measuring locations. Please wait 10 minutes after changing to a measuring location with a significantly different climate.

DESCRIPTION

Laserliner ClimaHome-Check Digital Hygrometer For Long Term Room Climate
Monitoring 2

  1. LC display
  2. Switch on MAX/MIN values
  3. CLEAR, reset MAX/MIN values
  4. Battery compartment
  5. Fold-out stand / clip
  6. Integrated magnetic holder
    • Room temperature in C
    • MAX/MIN values display
    • Relative humidity in %rH

DISPLAY

Laserliner ClimaHome-Check Digital Hygrometer For Long Term Room Climate
Monitoring 3

Information on maintenance and care

Clean all components with a damp cloth and do not use cleaning agents, scouring agents and solvents. Store the device in a clean and dry place.

Technical data

and dry place.|
---|---
 |
Technical data (Subject to technical changes without notice. 21W12)
Humidity

Measuring range (relative) Accuracy (absolute) Humidity (relative)

| ****

20% … 95%

± 3% (30% … 70%)

± 5% (20% … 30%, 70% … 95%)

Ambient temperature Measuring range Accuracy| ****

-9.9°C … 60°C

± 1°C (0°C … 50°C)

± 2°C (< 0°C und > 50°C)

Power supply| 1 x 1.5V LR03 (AAA)
Operating conditions| 0°C … 50°C, max. humidity, 95% rH, no condensation, max. working altitude 2000 m above sea level
Storage conditions| -10°C … 60°C, max. humidity, 80% rH
Dimensions (W x H x D)| 66 x 57 x 17 mm
Weight| 47 g (incl. battery)

EU directives and disposal

This device complies with all necessary standards for the free movement of goods within the EU. This product is an electric device and must be collected separately for disposal according to the European Directive on waste electrical and electronic equipment. Further safety and supplementary notices at: http://laserliner.com/info?an=AKH