Instruction on mounting and use
Closely follow the instructions set out in this manual. All responsibility,
for any eventual inconveniences, damages or fires caused by not complying with
the instructions in this manual, is declined. This appliance is intended to be
used in household and similar application such as: – staff kitchen areas in
shop, offices and other working environments; – farm houses; – by clients in
hotels, motels and other residential type environments; – bed and breakfast
type environments.
The hood can look different to that illustrated in the drawings in this
booklet. The instructions for use, maintenance and installation, however,
remain the same.
- It is important to conserve this booklet for consultation at any moment. In the case of sale, cession or move, make sure it is together with the product.
- Read the instructions carefully: there is important information about installation, use and safety.
- Do not carry out electrical or mechanical variations on the product or on the discharge conduits.
- Before proceeding with the installation of the appliance verify that there are no damaged all components. Otherwise contact your dealer and do not proceed with the installation.
Note: The parts marked with the symbol “(*)” are optional accessories supplied only with some models or otherwise not supplied, but available for purchase.
Caution
-
Before any cleaning or maintenance operation, disconnect hood from the mains by removing the plug or disconnecting the mains electrical supply.
-
Always wear work gloves for all installation and maintenance operations.
-
This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved.
-
Children shall not be allowed to tamper with the controls or play with the appliance.
-
Cleaning and user maintenance shall not be made by children without supervision.
-
The premises where the appliance is installed must be sufficiently ventilated, when the kitchen hood is used together with other gas combustion devices or other fuels.
-
The hood must be regularly cleaned on both the inside and outside (AT LEAST ONCE A MONTH).
-
This must be completed in accordance with the maintenance instructions provided. Failure to follow the instructions provided regarding the cleaning of the hood and filters will lead to the risk of fires.
-
Do not flambé under the range hood.
-
Do not remove filters during cooking.
-
For lamp replacement use only lamp type indicated in the Maintenance/Replacing lamps section of this manual.
The use of exposed flames is detrimental to the filters and may cause a fire risk, and must therefore be avoided in all circumstances. Any frying must be done with care in order to make sure that the oil does not overheat and ignite.
CAUTION: Accessible parts of the hood may become hot when used with cooking appliances. -
Do not connect the appliance to the mains until the installation is fully complete.
-
With regards to the technical and safety measures to be adopted for fume discharging it is important to closely follow the regulations provided by the local authorities.
-
The air must not be discharged into a flue that is used for exhausting fumes from appliance burning gas or other fuels.
WARNING! Failure to install the screws or fixing device in accordance with these instructions may result in electrical hazards. -
Do not use or leave the hood without the lamp correctly mounted due to the possible risk of electric shocks.
-
Never use the hood without effectively mounted grids.
-
The hood must NEVER be used as a support surface unless specifically indicated.
-
Use only the fixing screws supplied with the product for installation or, if not supplied, purchase the correct screws type.
-
Use the correct length for the screws which are identified in the Installation Guide.
-
In case of doubt, consult an authorized service assistance center or similar qualified person.
WARNING! Do not use with a programmer, timer, separate remote control system or any other device that switches on automatically.
Electrical connection
The mains power supply must correspond to the rating indicated on the plate
situated inside the hood. If provided with a plug connect the hood to a socket
in compliance with current regulations and positioned in an accessible area,
after installation. If it not fitted with a plug (direct mains connection) or
if the plug is not located in an accessible area, after installation, apply a
double pole switch in accordance with standards which assures the complete
disconnection of the mains under conditions relating to over-current category
III, in accordance with installation instructions.
WARNING! Before re-connecting the hood circuit to the mains supply and
checking the efficient function, always check that the mains cable is
correctly assembled.
Installation
-
The minimum distance between the supporting surface for the cooking equipment on the hob and the lowest part of the range hood must be not less than 60cm from electric cookers and 70cm from gas or mixed cookers.
If the instructions for installation for the gas hob specify a greater distance, this must be adhered to.
Check of the ceiling
The ceiling must be flat, horizontal, sturdy enough, and resistant
Warnings
The hood is designed to be installed in a dropped ceiling
The dropped ceiling must be sturdy and have a load-bearing capacity suitable for a product with max. weight of 30 Kg (model with steel panel) or 34 Kg (model with glass panel).
Do not install the hood directly in the dropped ceiling panels, but use a suitable frame or support. -
This appliance is marked according to the European directive 2012/19/EC – UK SI 2013 No.3113 on Waste Electrical and Electronic Equipment (WEEE).
-
By ensuring this product is disposed of correctly, you will help prevent potential negative consequences for the environment and human health, which could otherwise be caused by inappropriate waste handling of this product.
-
The symbol on the product, or on the documents accompanying the product, indicates that this appliance may not be treated as household waste. Instead it should be taken to the appropriate collection point for the recycling of electrical and electronic equipment. Disposal must be carried out in accordance with local environmental regulations for waste disposal.
-
For further detailed information regarding the process, collection and recycling of this product, please contact the appropriate department of your local authorities or the local department for household waste or the shop where you purchased this product. Appliance designed, tested and manufactured according to:
-
Safety: EN/IEC 60335-1; EN/IEC 60335-2-31, EN/IEC 62233.
-
Performance: EN/IEC 61591; ISO 5167-1; ISO 5167-3; ISO 5168; EN/IEC 60704-1; EN/IEC 60704-2-13; EN/IEC 60704-3; ISO 3741; EN 50564; IEC 62301.
-
EMC: EN 55014-1; CISPR 14-1; EN 55014-2; CISPR 14-2; EN/IEC 61000-3-2; EN/IEC 61000-3-3. Suggestions for a correct use in order to reduce the environmental impact: Switch ON the hood at minimum speed when you start cooking and kept it running for few minutes after cooking is finished. Increase the speed only in case of large amount of smoke and vapor and use boost speed(s) only in extreme situations. Replace the charcoal filter(s) when necessary to maintain a good odor reduction efficiency. Clean the grease filter(s) when necessary to maintain a good grease filter efficiency. Use the maximum diameter of the ducting system indicated in this manual to optimize efficiency and minimize noise.
Use
The hood is designed to be used for exhausting version.
In this case the fumes are conveyed outside of the building by means of a
special pipe connected with the connection ring located on top of the hood.
CAUTION!
The exhausting pipe is not supplied and must be purchased apart.
Diameter of the exhausting pipe must be equal to that of the connection ring.
CAUTION!
If the hood is supplied with active charcoal filter, then it must be removed.
Connect the hood and discharge holes on the walls with a diameter equivalent
to the air outlet (connection flange).
Using the tubes and discharge holes on walls with smaller dimensions will
cause a diminution of the suction performance and a drastic increase in noise.
Any responsibility in the matter is therefore declined.
! Use a duct of the minimum indispensable length.
! Use a duct with as few elbows as possible (maximum elbow angle: 90°).
! Avoid drastic changes in the duct cross-section.
Operation
This product is designed to work with an Elica remote control, either supplied
with the product or purchased separately as an optional. To control the hood
via remote control, the affiliation procedure must be carried out.
CAUTION!
To begin, the hood must be disconnected and then reconnected to the power
supply and the affiliation procedure must be carried out within the first
minute of connection to the power. Read the instructions supplied with the
remote control, which provide detailed instructions on affiliation and correct
use.
Note: the Speed 4 (and the Speed 5, where applicable) if selected, will
activate for a limited period of time after which Speed 2 is automatically
enabled.
Remote control connection (if applicable)
Once the remote control has been connected, this will be displayed on the
hood: both LEDs flash.
Note: Using the remote control, delayed shut-down can be programmed based
on the aspiration speed (power) enabled at that moment:
Speed 1 (low aspiration): 20 minutes
Speed 2 (medium aspiration): 15 minutes
Speed 3 (high aspiration): 10 minutes
Filter Saturation indicator lights
At regular intervals, the LEDs on the hood indicate the need to carry out
filter maintenance.
Note: The filter saturation signal is visible for a few seconds when the
hood is switched on; within this time, the saturation indicator lights must be
reset.
Flashing Green LED: carry out maintenance on the grease filter.
Red flashing LED: carry out maintenance on the charcoal filter (only for hoods
operating in “Filtration Version”).
Note: Run the “RESET FILTRES” command via the remote control.
Activating/deactivating the filter saturation indicator light
Note: Run the procedure with the hood switched off. The charcoal filter
saturation indicator light is usually deactivated.
If no control is given within maximum 10 sec, the hood automatically exits
this function, at any time, and returns to the previous state. Press and hold
the B+C keys (Simultaneously) to enter the setup menu:
Briefly press button C to select the filter to be set up:
Grease filter:Green Charcoal filter: Red Briefly press button B to activate
(the 2nd LED flashing) or deactivate (2nd LED off).
Note: the LEDs light up for a limited number of seconds after which they
turn off to indicate that the indicator light has been activated (or
deactivated).
The device can also be used in combination with a Window sensor KIT (not
supplied by the manufacturer).
If the Window sensor KIT is installed (only in the case of use in EXTRACTOR
mode), air extraction will halt every time the window in the room, on which
the KIT is applied, is closed.
-
The KIT must be electrically connected to the device by qualified and specialised technical personnel.
-
The KIT must be certified separately in accordance with the safety standards for the component and its use with the device. Installation must be carried out in accordance with current regulations for domestic systems.
PLEASE NOTE: -
the wiring of the KIT to be connected to the device must be part of a certified safety extra-low voltage (SELV) circuit.
-
the manufacturer of this device declines all liability for any inconvenience, damage or fires caused by defects and/or problems associated with the malfunction and/or incorrect installation of the KIT.
Maintenance
Cleaning
Clean using ONLY a cloth dampened with neutral liquid detergent.
DO NOT CLEAN WITH TOOLS OR INSTRUMENTS. Do not use abrasive products. DO NOT
USE ALCOHOL!
Panel
Fig. 3-17
The panel for perimeter suction should always be left closed and should only
be opened in case of maintenance interventions (eg cleaning or replacing
filters).
Grease filter
Fig. 3-17
Traps cooking grease particles.
This must be cleaned once a month (or when the filter saturation indication
system – if envisaged on the model in possession – indicates this necessity)
using non aggressive detergents, either by hand or in the dishwasher, which
must be set to a low temperature
and a short cycle.
When washed in a dishwasher, the grease filter may discolor slightly, but this
does not affect its filtering capacity.
To remove the grease filter, pull the spring release handle.
Replacing lamps
The hood is equipped with a lighting system based on LED technology.
The LEDs guarantee an optimum lighting, a duration up to 10 times longer than
the traditional lamps and allow to save 90% electrical energy.
The lighting system cannot be replaced by the user, contact Customer Service
in case of malfunction.