INSTRUCTION MANUAL AND WARRANTY INFORMATION
1-YEAR LIMITED WARRANTY
IMPORTANT SAFETY INSTRUCTIONS
WHEN USING ELECTRICAL PRODUCTS, BASIC SAFETY PRECAUTIONS SHOULD ALWAYS BE
FOLLOWED, INCLUDING THE FOLLOWING:
READ ALL INSTRUCTIONS BEFORE USING.
DANGER – TO REDUCE THE RISK OF ELECTRIC SHOCK:
- DO NOT place or store appliance where it can fall or be pulled into a tub or sink. • DO NOT place in or drop into water or other liquids.
WARNING – TO REDUCE THE RISK OF BURNS, FIRE, ELECTRIC SHOCK,
OR INJURY TO PERSONS:
-
DO NOT attempt to look directly at the UV LEDs while the unit is on. UV light
can be irritating to the eyes and skin. -
DO NOT attempt to modify this product. It has been designed to contain
UV exposure. -
THIS PRODUCT IS PROVIDED WITH A SAFETY MECHANISM TO REDUCE THE
RISK OF EXPOSURE TO ULTRAVIOLET RADIATION.
SAVE THESE INSTRUCTIONS
CAUTION – PLEASE READ ALL INSTRUCTIONS CAREFULLY BEFORE OPERATING.
- DO NOT expose the device to fire or excessive temperature. Exposure to fire
or temperatures above 265°F may cause explosion. • Follow all charging instructions and do not charge the device outside of
the temperature range specified. Charging improperly or at temperatures
outside of the specified range may damage the battery and increase the risk
of fire. Product operating and charging range: 32°F – 104°F/0°C – 40°C.
UNIQUE FEATURES & SPECIFICATIONS
UV-C TECHNOLOGY
Ultraviolet (UV) light is a short wavelength light invisible to the human eye.
It kills up to 99.9% of bacteria and viruses. There are cold-, heat-, and
drugresistant
germs. There are no common UV-C resistant germs.
REVOLUTIONARY LED TECHNOLOGY
Environmentally friendly, and is mercury and chemical free.
RECHARGEABLE
This battery-powered sanitizer can run up to 30 sanitizing cycles per charge,
all while you’re on the go! This product will not sanitize while it is
charging.
PROPRIETARY POP UP
Through research, simulations and third-party lab testing, we’ve derived the
maximum sanitization efficacy between light dispersion angle and UV-C
intensity. Our pop-up mechanism ensures optimal ultraviolet light exposure
across the surface or object. So popping up your wand provides maximum
efficacy.
ULTRAFAST SANITIZATION
Kills up to 99.9% of viruses and bacteria* at the DNA level in less than 5
seconds.
Slowly sweep the wand over any surface or object for maximum sanitization.
SAFE
Childproof safety feature ensures device can only be used when the two side
buttons are pressed and held after the top power button is pressed. After the
top
power button is pressed, the side buttons must remain pressed in to sanitize.
ANTIBACTERIAL COATING
All exposed components of this product feature an antibacterial coating so
your
hands stay germ free.
PORTABLE SANITIZER WAND
CHARGING YOUR PORTABLE SANITIZER WAND
Charging takes 2-3 hours for a full charge.
-
To charge your wand, use the included charging cable. Plug the small end
(micro USB) into the charging port, beneath the protective cover. Plug the
USB end into a computer or USB wall charger. -
The power icon of the wand will show flashing green when charging.
-
When the wand is fully charged, the LED will turn solid green.
-
One full charge will give you 30 sanitizing cycles.
LED INDICATORS
- Solid red
|
-
At the end of the sanitizing cycle, solid red for 3 seconds and
then off: 20%-30% battery left and can sanitize -
Solid red for 3 seconds when the power button is pressed: <20%
battery left and cannot sanitize
---|---
- Flashing red for
3 seconds
|
-
Both side buttons are not pressed in
-
Solid green
|
-
Fully charged
-
Flashing blue
|
-
In sanitizing mode
-
Flashing green
|
-
Charging
-
Alternating red
and blue flashing
for 3 seconds
|
- UV-C LED malfunction
HOW TO USE
-
Remove cover (Fig. 1).
-
Pop up (Fig. 2).
-
Press power button (Fig. 3).
-
Within 10 seconds of pressing the power button, press and hold both side
buttons (Fig. 4). -
Wave wand over any surface or object to sanitize; side buttons must be
pressed in to sanitize (Fig. 5). -
LED light ring will flash blue during the 1-minute sanitization cycle. To run
another cycle, repeat steps 3-5.
Both side buttons must be pressed during the entire sanitizing cycle. If you
release either side button, the wand will turn off.
Slowly sweep the wand over any surface or object for maximum sanitization.
Always use the sanitizing wand facing the surface or object that you wish
to sanitize. Do not shine it into the air or toward yourself, other humans or
animals.
Homedics SAN-W100 Portable Sanitizer Wand Manual
TROUBLESHOOTING
FAQS
HOW DO I KNOW IF THE WAND IS WORKING?
The light ring will flash blue indicating the UV-C LEDs are on and
sanitizing. Use the UV-C test strip for proof of the UV-C LED’s effectiveness.
LED INDICATOR KEEPS FLASHING RED. WHAT DOES IT MEAN?
Flashing red means the safety mechanism is not engaged. Please make
sure to press and hold both side buttons after a short press of the power
button.
IS THIS SAFE TO USE ON ELECTRONIC DEVICES?
Yes, UV CLEAN uses UV-C light, not water or chemicals. UV-C light kills germs
and is completely safe for use on electronic devices.
WHAT CAN IT SANITIZE?
The UV CLEAN Portable Sanitizer Wand was designed to sanitize just
about anything. Use it to sanitize any surface or object. UV-C light is
harmful to the eyes and skin. Avoid direct exposure. For more information
about how UV-C works, please visit www.HoMedics.com.
FAQS (CONT.)
WILL IT SANITIZE IF IT’S NOT POPPED UP?
Yes, the wand will still work and the UV-C LEDs will still turn on if the wand
buttons are pressed correctly according to instructions. However, if it is not
popped up, then the coverage area of the UV-C light is greatly reduced.
CAN I RUN MULTIPLE CONSECUTIVE SANITIZING CYCLES?
Yes, you can! Though the first slow sweep over something will have
sanitized the surface or object up to 99.9%, there is no harm in doing it
again if you wish.
CARE AND MAINTENANCE
- Clean surface with a soft, damp cloth.
- DO NOT use harsh chemicals.
WARNING : This product has an internal, nonreplaceable lithium battery.
Please dispose in accordance with your local, state, province, and country
guidelines. Batteries (battery pack or batteries installed) should not be
exposed to excessive heat such as sunshine, fire, or the like.
WEE EXPLANATION
This marking indicates that this product should not be
disposed of
with other household wastes throughout the EU. To prevent possible
harm to the environment or human health from uncontrolled waste
disposal, recycle it responsibly to promote the sustainable reuse of
material resources. To return your used device, please use the return
and collection systems or contact the retailer where the product was
purchased. They will accept this product for environmentally safe
recycling.
BATTERY DIRECTIVE
This symbol indicates that batteries must not be
disposed of in
domestic waste as they contain substances which can be damaging
to the environment and our health. Please dispose of batteries in
designated collection points.
FCC AND IC STATEMENTS
This device complies with Part 15 of the FCC Rules. Operation is subject to
the
following two conditions: (1) This device may not cause harmful interference,
and
(2) This device must accept any interference received, including interference
that
may cause undesired operation.
NOTE: HoMedics is not responsible for any radio or TV interference caused
by
unauthorized modifications to this equipment. Such modifications could void
the user authority to operate the equipment.
NOTE: This equipment has been tested and found to comply with the limits
for
a Class B digital device, pursuant to Part 15 of the FCC Rules and CAN ICES-3
(B)/
NMB-3 (B). These limits are designed to provide reasonable protection against
harmful interference in a residential installation. This equipment generates,
uses, and can radiate radio frequency energy and, if not installed and used
in accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not
occur
in a particular installation. If this equipment does cause harmful
interference
to radio or television reception, which can be determined by turning the
equipment off and on, the user is encouraged to try to correct the
interference
by one or more of the following measures:
-
Reorient or relocate the receiving antenna.
-
Increase the separation between the equipment and receiver.
-
Connect the equipment into an outlet on a circuit different from that to
which the receiver is connected. -
Consult the dealer or an experienced radio/TV technician for help.
RSS INFORMATION
This device complies with RSS-210 of the IC Rules. Operation is subject to the
following 2 conditions: (1) This device may not cause harmful interference,
and
(2) This device must accept any interference received, including interference
that
may cause undesired operation. This Class B digital apparatus complies with
Canadian ICES-003.
SUPPLIER’S DECLARATION OF CONFORMITY
Product Description: UV CLEAN PORTABLE SANITIZER WAND™
Model Number: SAN-W100
Trade Name: HoMedics
FCC Compliance Statement
This device complies with Part 15 of the FCC Rules. Operation is subject to
the
following two conditions: (1) This device may not cause harmful interference,
and
(2) This device must accept any interference received, including interference
that
may cause undesired operation.
U.S. Contact Information
Company: HoMedics LLC
Address: 3000 N Pontiac Trail, Commerce Township, MI 48390
8:30am-7:00pm EST Monday-Friday
1-800-466-3342
1-YEAR LIMITED WARRANTY
HoMedics sells its products with the intent that they are free of defects in
manufacture and
workmanship for a period of 1 year from the date of original purchase, except
as noted below.
HoMedics warrants that its products will be free of defects in material and
workmanship under
normal use and service. This warranty extends only to consumers and does not
extend to Retailers.
To obtain warranty service on your HoMedics product, contact a Consumer
Relations representative
for assistance. Please make sure to have the model number of the product
available.
HoMedics does not authorize anyone, including but not limited to Retailers,
the subsequent
consumer purchaser of the product from a Retailer, or remote purchasers, to
obligate HoMedics
in any way beyond the terms set forth herein. This warranty does not cover
damage caused by
misuse or abuse; accident; the attachment of any unauthorized accessory;
alteration to the product;
improper installation; unauthorized repairs or modifications; improper use of
electrical/power supply;
loss of power; dropped product; malfunction or damage of an operating part
from failure to provide
manufacturer’s recommended maintenance; transportation damage; theft; neglect;
vandalism; or
environmental conditions; loss of use during the period the product is at a
repair facility or otherwise
awaiting parts or repair; or any other conditions whatsoever that are beyond
the control of HoMedics.
This warranty is effective only if the product is purchased and operated in
the country in which the
product is purchased. A product that requires modifications or adoption to
enable it to operate
in any other country than the country for which it was designed, manufactured,
approved, and/or
authorized, or repair of products damaged by these modifications is not
covered under this warranty.
THE WARRANTY PROVIDED HEREIN SHALL BE THE SOLE AND EXCLUSIVE WARRANTY. THERE
SHALL BE NO OTHER WARRANTIES EXPRESS OR IMPLIED, INCLUDING ANY IMPLIED
WARRANTY
OF MERCHANTABILITY OR FITNESS OR ANY OTHER OBLIGATION ON THE PART OF THE
COMPANY
WITH RESPECT TO PRODUCTS COVERED BY THIS WARRANTY. HOMEDICS SHALL HAVE NO
LIABILITY FOR ANY INCIDENTAL, CONSEQUENTIAL, OR SPECIAL DAMAGES. IN NO EVENT
SHALL
THIS WARRANTY REQUIRE MORE THAN THE REPAIR OR REPLACEMENT OF ANY PART OR PARTS
THAT ARE FOUND TO BE DEFECTIVE WITHIN THE EFFECTIVE PERIOD OF THE WARRANTY.
NO REFUNDS WILL BE GIVEN. IF REPLACEMENT PARTS FOR DEFECTIVE MATERIALS ARE NOT
AVAILABLE, HOMEDICS RESERVES THE RIGHT TO MAKE PRODUCT SUBSTITUTIONS IN LIEU
OF REPAIR OR REPLACEMENT.
This warranty does not extend to the purchase of opened, used, repaired,
repackaged, and/or
resealed products, including but not limited to sale of such products on
internet auction sites and/
or sales of such products by surplus or bulk resellers. Any and all warranties
or guarantees shall
immediately cease and terminate as to any products or parts thereof that are
repaired, replaced,
altered, or modified, without the prior express and written consent of
HoMedics.
This warranty provides you with specific legal rights. You may have additional
rights that may vary
from country to country. Because of individual country regulations, some of
the above limitations
and exclusions may not apply to you.
For more information regarding our product line in the USA, please visit
www.HoMedics.com.
For Canada, please visit www.HoMedics.ca.
FOR SERVICE IN THE USA
cservice@HoMedics.com
8:30am–7:00pm EST Monday–Friday
1-800-466-3342
FOR SERVICE IN CANADA
cservice@HoMedicsgroup.ca
8:30am–5:00pm EST Monday–Friday
1-888-225-7378
Read More About This Manual & Download PDF:
Homedics SAN-W100 Portable Sanitizer Wand Manual – Optimized
PDF
Homedics SAN-W100 Portable Sanitizer Wand Manual – Original
PDF
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>