Safety Information
Safety signs
Overview
The iLOQ F50S Key Tube Lock Cylinders are battery-free programmable electromechanical key tube lock cylinders for the iLOQ S50 locking system.
Two different Reader Knob lengths are available, short and long. In the product code (e.g. F50S.2×1.HZ), replace “x” with 1 = short reader or 2 = long reader.
Care and Maintenance
-
The instructions should be carefully followed during installation and use. These instructions and any maintenance instructions should be passed on by the installer to the user.
-
The iLOQ F50S Key Tube Lock Cylinders must be installed and used carefully without excessive force.
-
Do not drop the product.
-
The product should not be modified in any way except in accordance with the modifications
described in these instructions. -
Due to the integrated spring operated locking bolt the F50S Key Tube Lock Cylinder is self-locking, use with care.
-
The product is designed to be maintenance-free. It does not require any regular maintenance.
Installation of the iLOQ F50S Key Tube Lock Cylinder
To conform with local requirements, use locally approved key tubes (please note: the key tube is not included in delivery).
Mount the key tube according to the tube manufacturer’s instructions. To ensure reliable operation of the F50S Key Tube Lock Cylinder make sure that the tube is at a 4 degree angle to prevent water pooling inside and the key tube is mounted max. 5mm inside the wall surface.
In case an existing key tube is mounted too deep inside the wall and the F50S Key Tube Lock Cylinder cannot be placed in the key tube, it is possible to replace the Reader Knob with a longer version. (See Section 6 for replacing the Reader Knob).
See the correct positioning of the F50S Key Tube Lock Cylinder inside the tube from the following image
Compatible Key Tubes
The following key tubes are compatible with F50S Key Tube Lock Cylinder:
Please verify the compatibility of the key tubes beforehand.
Replacing the Reader Knob
The Reader Knob may need to be replaced if the length of the original knob is not suitable for the installation environment or the knob is damaged.
1. Loosen the screw on the Reader Knob. Use a T10 (torx) tool.
2. Pull the Reader Knob off the neck.
3. Slide the new Reader Knob onto the neck so that the screw hole is facing the same direction as the two knob adjustment slots in the neck.
4. Tighten the screw to a torque of 1.5 Nm. Use a T10 (torx) tool.
After installation
Make sure that you have installed all components necessary for the specific installation. Open and close the F50S Key Tube Lock Cylinder to test the cylinder functionality after installation.
Instructions for use
The F50S Key Tube Lock Cylinder needs to be initially programmed with a PC and an iLOQ P55S.1 Programming Key. See separate instructions for programming from the P55S.1 Programming Key user guide.
Open the key tube
Lock the key tube
Disposal of Decommissioned Products
Compliance
The products mentioned inside this user guide are in conformity with the requirements of the directives declared on this page.
CE
SIMPLIFIED EU DECLARATION OF CONFORMITY:
Hereby, iLOQ Oy declares that the radio equipment type H50S Padlocks are in
compliance with Directive 2014/53/EU. The full text of the EU declaration of
conformity is available at the following internet address:
https://www.iloq.com/en/company/patents-and-approvals/
Communication standard: NFC 13,56 MHz Load modulation (ASK) ISO/IEC 14443A, no transmitter.
FCC
Chapter 1, Subpart A, Part 2 of Title 47 of the Code of Federal Regulations The conformity was assessed in accordance the following standard: FCC – FCC Rule Part 15
Note : This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
ISED
Innovation, Science and Economic Development Canada (ISED)
The conformity was assessed in accordance the following standard:
ISED – ICES 003, Issue 7: 2020 – class B
UKCA
Hereby, iLOQ Oy declares that the radio equipment type H50S Padlocks are in compliance with the UK relevant statutory requirements. The full text of the declaration of conformity is available at the following internet address: https://www.iloq.com/en/company/patents-and-approvals/
iLOQ
www.support.iloq.com
Elektroniikkatie 10
90590 Oulu
Finland
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>