Module Designation| Colour Temperature| Colour Rendering Index| Module Luminous Flux| Luminaire Luminous Flux| Luminaire Luminous Efficiency
---|---|---|---|---|---
84 557 K27| 2700 K| CRI > 80| 5760 lm| 3886 lm| 101.2 lm / W
84 557 R K27| 2700 K| CRI > 80| 5760 lm| 3402 lm| 88.6 lm / W
84 557 K3| 3000 K| CRI > 80| 6010 lm| 4055 lm| 105.6 lm / W
84 557 R K3| 3000 K| CRI > 80| 6010 lm| 3550 lm| 92.4 lm / W
84 557 K4| 4000 K| CRI > 80| 6165 lm| 4160 lm| 108.3 lm / W
84 557 R K4| 4000 K| CRI > 80| 6165 lm| 3642 lm| 94.8 lm / W

Product Usage Instructions

  1. Overvoltage protection: The electronic components installed in the luminaire are protected against overvoltage according to DIN EN 61547. For additional protection against transients, it is recommended to use separate overvoltage protection components. You can find them on our website at www.bega.com.
  2. Please note: Do not remove the desiccant bag from the luminaire housing. It is needed to remove residual moisture.

Instructions for use

Application

Floodlight with symmetrical wide beam light distribution.
For embedding in gravel, lawns, flower beds, or in compacted, non-inflammable surfaces. Drive-over luminaire for vehicles with pneumatic tyres.

Please note:

Luminaire must not be used for installation in road lanes, where the fixture is exposed to a horizontal strain due to braking, acceleration and change of direction.
For walk-through public areas, we recommend skid-blocking glass– see accessories.

DIMENSION

BEGA-84557-In-Ground-Luminaire-FIG-
\(1\)

Product Description

  • Luminaire made of stainless steel
  • Steel grade no. 1.4301
  • Clear safety glass
  • Reflector surface made of pure aluminium Optical silicone lens · BEGA Hybrid Optics® 1,8 m water-resistant connecting cable 07RN8-F 5 G 1@ with implemented water stopper and 1.2 m PVC cable conduit
  • BEGA Ultimate Driver®
  • LED power supply unit
  • 220-240 V x 0/50-60 Hz
  • DC 176-264 V
  • DALI controllable
  • A basic isolation exists between power cable and control line
  • BEGA Thermal Control®
  • Temporary thermal regulation to protect temperature-sensitive components without switching off the luminaire
  • Safety class I
  • Protection class IP 68 10 m
  • Dust-tight and water pressure tight
  • Maximum submersion depth 10 m
  • Not suitable for permanent operation under water
  • Pressure load 2,000 kg (~20 kN)
  • Impact strength IK10
  • Protection against mechanical impacts < 20 joule
  • Maximum surface temperature 30 °C (measured according to EN 60598 of ta 15 °C)
  • Conformity mark
  • Safety mark
  • Weight: 7.2 kg
  • This product contains light sources of energy efficiency class(es) D

Safety

  • The installation and operation of this luminaire are subject to national safety regulations. Installation and commissioning may only be carried out by a qualified electrician.
  • We recommend fuse protection via a residual current circuit breaker to be provided by the customer.
  • The manufacturer accepts no liability for damage caused by improper use or installation. If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.

Overvoltage protection

  • The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547.
  • To achieve additional protection against e. g. transients, etc. we recommend separate overvoltage protection components.
  • You can find them on our website at www.bega.com.BEGA-84557-In-Ground-Luminaire-FIG- \(2\)

Installation

  • Luminaire housing must not be installed in heat-insulating material.
  • Luminaire for recessed mounting in gravel, lawns and flower beds.
  • The recessed depth must be arranged such that the trim ring is above ground level.
  • When installed in compacted surfaces make sure that the housing is firmly fixed and that the trim ring is not directly resting on the pavement or other surfaces (Fig. A). For this purpose installation housing 70 688 can be practical (Fig. B).
  • The electrical connection must be carried out with matching protection class and safety class with suitable connection terminals (not included in the scope of delivery) at the luminaire power supply cable.
  • We recommend that you use distribution box 70 730 or 71 053 for this purpose.
  • Ensure that the connection cable is correctly connected.
  • Make the mains connection to the brown (L), blue (N) and green-yellow wires ( ).
  • The control cables are connected via the two wires marked DALI.
  • If these wires are not assigned, the luminaire will work with full light output.
  • Tighten the screws in the trim ring evenly crosswise.
  • Torque = 5 Nm.

Please note:

Do not remove the desiccant bag from the luminaire housing.
It is needed to remove residual moisture.

FEATURES

Lamp

  • Module connected wattage 35.7 W
  • Luminaire connected wattage 38.4 W
  • Rated temperature ta = 25 °C
  • Ambient temperature ta max = 40 °C

84 557 K27

  • Module designation LED-0785/827
  • Colour temperature 2700 K
  • Colour rendering index CRI > 80
  • Module luminous flux 5760 lm
  • Luminaire luminous flux 3886 lm
  • Luminaire luminous efficiency 101,2 lm / W

84 557 R K27

  • Module designation LED-0785/827
  • Colour temperature 2700 K
  • Colour rendering index CRI > 80
  • Module luminous flux 5760 lm
  • Luminaire luminous flux 3402 lm
  • Luminaire luminous efficiency 88,6 lm / W

84 557 K3

  • Module designation LED-0785/830
  • Colour temperature 3000 K
  • Colour rendering index CRI > 80
  • Module luminous flux 6010 lm
  • Luminaire luminous flux 4055 lm
  • Luminaire luminous efficiency 105,6 lm / W

84 557 R K3

  • Module designation LED-0785/830
  • Colour temperature 3000 K
  • Colour rendering index CRI > 80
  • Module luminous flux 6010 lm
  • Luminaire luminous flux 3550 lm
  • Luminaire luminous efficiency 92,4 lm / W

84 557 K4

  • Module designation LED-0785/840
  • Colour temperature 4000 K
  • Colour rendering index CRI > 80
  • Module luminous flux 6165 lm
  • Luminaire luminous flux 4160 lm
  • Luminaire luminous efficiency 108,3 lm / W

84 557 R K4

  • Module designation LED-0785/840
  • Colour temperature 4000 K
  • Colour rendering index CRI > 80
  • Module luminous flux 6165 lm
  • Luminaire luminous flux 3642 lm
  • Luminaire luminous efficiency 94,8 lm / W

Lighting technology

Half beam angle 21°

Cleaning Maintenance

  • After installation, the luminaire should first be cleaned. Building dust, residues from contact adhesives, paint splashes and rust film must be completely removed. Never use high pressure cleaners and cleaning implements made of normal steel, steel brushes or steel wool because they cause extraneous rust to form. When using stainless steel cleaners, please read the directions carefully.
  • Cleaning agents containing hydrochloric acid and chlorides should never be used.
  • We recommend cleaning the luminaires regularly.

Replacing the LED module

  • The designation of the LED module is noted on a label in the luminaire.
  • The light colour and light output of BEGA replacement modules correspond to those of the modules originally fitted. The module can be replaced by qualified persons using standard tools.
  • Disconnect the electrical installation.
  • LED are high-quality electronic components! Please avoid touching the light output opening of the LED directly during relamping.
  • Clean dirt and deposits from key openings of screw head. Do not use a high pressure cleaner. Open the luminaire and clean.
  • Use only solvent-free cleaners.
  • The luminaire housing must be completely clean and absolutely dry.
  • Please follow the installation instructions for the LED module.
  • Check all screws and threads thoroughly and grease them.
  • Check the gasket and replace, if necessary. A broken glass must be replaced.
  • Insert glass with gasket – with stepped side turned upward and the groove structure of the gasket turned downward – into the luminaire housing. Make sure that the glass is correctly positioned in the gasket bed.
  • Place trim ring onto glass step and tighten screws crosswise.
  • Torque = 5 Nm.

Accessories

14000233R Skid-blocking glass
BEGA skid-blocking glass with the highest rating R 13 according to DIN 51130 can be used without restriction for all public areas. Abrasion resistance according to
EN ISO 10545-7 Class 3

  • 70 688 Installation housing
  • 70 730 Distribution box for installation in soil with 7 cable entries Connection terminals 5 x 4@

For the accessories, a separate instructions for use can be provided upon request.

Spares

  • Spare glass skid blocking 14 000 233 R
  • Spare glass 14 001 523
  • LED power supply unit DEV-0270/700i
  • LED module 2700 K LED-0785/827
  • LED module 3000 K LED-0785/830
  • LED module 4000 K LED-0785/840
  • Reflector 76 001 613
  • Gasket glass 83 002 037