Product Name 23 250.3 K3
Module Designation 2x LED-0424/930
Colour Temperature 3000 K
Colour Rendering Index (CRI) > 90
Module Luminous Flux 1260 lm
Luminaire Luminous Flux 912 lm
Luminaire Luminous Efficiency 103.6 lm / W

Safety

The installation and operation of this luminaire are subject to national safety regulations. Installation and commissioning may only be carried out by a qualified electrician. The manufacturer accepts no liability for damage caused by improper use or installation. If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.

Overvoltage Protection

The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547. To achieve an additional protection against e.g. transients, etc. we recommend separate overvoltage protection components. You can find them on our website at www.bega.com.

Installation

For mounting and dismantling, please keep a minimum distance of 250 mm between the removable cap and the wall. LEDs are high-quality electronic components! Please avoid touching the light output opening of the LED directly during installation or relamping.

Spares

Spare Glass 11 002 946 .1R G
LED Power Supply Unit DEV-0304/350
LED Module 3000 K LED-0424/930
Gasket 83 001 179

Instructions for use

Application

  • Wall luminaire · indoor luminaire made of hand-blown opal glass and metal housing, for all lighting tasks in interior applications.
  • They are ideal for places where a soft and uniform lighting distribution is required. Luminaire with a high protection class.

DIMENSION

BEGA-23250-3-Wall-Luminaire-for-Indoor-Use-FIG-
\(2\)

Product Description

  • Luminaire made of Aluminium, finish Chrome
  • Hand-blown opal glass
  • 2 elongated fixing holes
  • Width 6 mm · 275 mm spacing
  • Insulating housing with cable entry formains supply cable up to ø 10,5 mm,
  • max. 3 x 1,5@
  • Connection terminal 2.5@
  • Earth conductor connection
  • BEGA Ultimate Driver®
  • LED power supply unit
  • 220-240 V x 0/50-60 Hz
  • DC 176-264 V
  • BEGA Thermal Switch®
  • Temporary thermal shutdown to protect temperature-sensitive components
  • Safety class I
  • Protection class IP 44
  • Protected against granular foreign bodies
  • ≥ 1 mm and splash water
  • Impact strength IK02
  • Protection against mechanical impacts < 0.2 joule
  • Safety mark
  • Conformity mark
  • Weight: 1.7 kg
  • This product contains light sources of energy efficiency class(es) D

Safety

  • The installation and operation of this luminaire are subject to national safety regulations. Installation and commissioning may only be carried out by a qualified electrician.
  • The manufacturer accepts no liability for damage caused by improper use or installation. If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.

Overvoltage protection

  • The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547.
  • To achieve an additional protection against e. g. transients, etc. we recommend separate overvoltage protection components.
  • You can find them on our website at www.bega.com.

FEATURES

Lamp

  • Module connected wattage 7.6 W
  • Luminaire connected wattage 8.8 W
  • Rated temperature ta = 25 °C
  • Ambient temperature ta max = 40 °C

23 250.3 K3

  • Module designation 2x LED-0424/930
  • Colour temperature 3000 K
  • Colour rendering index CRI > 90
  • Module luminous flux 1260 lm
  • Luminaire luminous flux 912 lm
  • Luminaire luminous efficiency 103,6 lm / W

Insulation housing

BEGA-23250-3-Wall-Luminaire-for-Indoor-Use-FIG- \(3\)

Installation

  • For mounting and dismantling please keep a minimum distance of 250 mm between the removable cap and the wall.
  • LEDs are high-quality electronic components!Please avoid touching the light output opening of the LED directly during installation or relamping.

Open luminaire:

  • Loosen knob, remove cap and glass.
  • Drill mounting holes into the mounting surface – spacing 275 mm.
  • For the mains supply connecting open the insulation housing – pull open – strip mains supply cable max. 15 mm and lead it into the insulation housing – see sketch.
  • Make earth conductor connection and electrical connection.
  • Connect both parts of the insulation housing until they audibly engage.
  • The outer coating of the cable has to be fully enclosed by the compression nipple.
  • Fix luminaire with enclosed or any other suitable fixing material onto the mounting surface. Place glass into luminaire housing, close luminaire with the cap and screw in knob into the cap.

Replacement of the LED module

  • The designation of the LED module is noted on a label in the luminaire.
  • The light colour and light output of BEGA replacement modules correspond to those of the modules originally fitted. The module can be replaced by qualified persons using standard tools.
  • Disconnect the system.
  • Loosen lateral knob, remove cap and take out glass.
  • Please follow the installation instructions for the LED module.
  • Defective glass must be replaced.
  • Insert glass into luminaire housing, close luminaire with the cap and screw in knob into the cap.

Spares

  • Spare glass 11 002 946 .1R G
  • LED power supply unit DEV-0304/350
  • LED module 3000 K LED-0424/930
  • Gasket 83 001 179

BEGA Gantenbrink-Leuchten KG · Postfach 31 60 · 58689 Menden · info@bega.com
www.bega.com

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals