BEGA 50064.5 Wall Luminaire for Indoor Use Instruction Manual
- June 13, 2024
- BEGA
Table of Contents
Wall luminaire for indoor use
50 064.5
Instructions for use
Application
Wall luminaire · indoor luminaire with integrated power supply unit for many
lighting tasks in interior applications.
The light emits upwards and downwards.
Product description
Luminaire made of aluminum alloy Finish Colour velvet black Crystal glass with
white matt finish 2 elongated fixing holes Width 4.5 mm · 84 mm spacing 2
cable entries for through-wiring of mains supply cable ø 7-10.5 mm, max. 5 G
1.5@ Connection terminal 2.5@ Earth conductor connection 2-pole connecting
terminal for digital control
BEGA Ultimate Driver®
LED power supply unit 220-240 V x 0/50-60 Hz DC 176-276 V
DALI-controllable
Number of DALI addresses: 1
Basic insulation is provided between the mains and control cables
BEGA Thermal Control®
Temporary thermal regulation to protect temperature-sensitive components
without switching off the luminaire
Safety class I
Impact strength IK07
Protection against mechanical impacts < 2 joule
– Safety mark
****– Conformity mark
Weight: 1.6 kg
This product contains light sources of energy efficiency class(es) D
Safety
The installation and operation of this luminaire are subject to national
safety regulations.
Installation and commissioning may only be carried out by a qualified
electrician.
The manufacturer accepts no liability for damage caused by improper use or
installation.
If subsequent modifications are made to the luminaire, the person responsible
for these modifications shall be considered the manufacturer.
Overvoltage protection
The electronic components installed in the luminaire are protected against
overvoltage in accordance with DIN EN 61547.
To achieve an additional protection against e. g. transients, etc. we
recommend separate overvoltage protection components.
You can find them on our website at www.bega.com.
Lamp
Module connected wattage | 16.4 W |
---|---|
Luminaire connected wattage | 19.3 W |
Rated temperature | ta = 25 °C |
Ambient temperature | ta max = 40 °C |
50 064.5 K3
Module designation | 2x LED-0275/930 |
---|---|
Colour temperature | 3000 K |
Colour rendering index | CRI > 90 |
Module luminous flux | 3290 lm |
Luminaire luminous flux | 1174 lm |
Luminaire luminous efficiency | 60,8 lm / W |
Installation
LED are high-quality electronic components!
Please avoid touching the light output opening of the LED directly during
installation or relamping.
Undo the screws and lift off the luminaire top. Lead the mains supply cable
through the cable entry of the luminaire base.
Note position of application of the luminaire “arrow down”. Fix luminaire base
with enclosed or any other suitable fixing material onto the mounting surface.
Be sure to use the gasket rings supplied. Make earth conductor connection.
Push silicone sleeves over the lines and make electrical connection.
For digital control please use the connecting terminal DA, DA.
In case this terminal is not used the luminaire will be operated at full light
output.
Make earth conductor connection between luminaire top and luminaire base (plug
connection).
Install the luminaire top, press-on and manually tighten screws evenly.
Cleaning · Maintenance
Clean luminaire regularly with solvent-free cleansers from dirt.
Replacing the LED module
The designation of the LED module is noted on a label in the luminaire.
The light colour and light output of BEGA replacement modules correspond to
those of the modules originally fitted.
The module can be replaced by qualified persons using standard tools.
Disconnect the system and open the luminaire. Please follow the installation
instructions for the LED module.
Inspect and, if necessary, replace the luminaire gaskets.
Defective glass must be replaced. Close the luminaire.
Spares
LED power supply unit | DEV-0312/500 |
---|---|
LED module 3000 K | LED-0275/930 |
BEGA Gantenbrink-Leuchten KG · Postfach 31 60 · 58689 Menden · info@bega.com · www.bega.com
References