BEGA 24 455 House Number Luminaire Instructions

June 13, 2024
BEGA

BEGA 24 455 House Number Luminaire

Product Information

This product is a house number luminaire made of aluminium alloy with crystal glass. It is designed to display one up to three-digit numbers. The installation and operation of this luminaire must comply with national safety regulations. Only a qualified electrician should perform the installation and commissioning. The manufacturer is not liable for any damage caused by improper use or installation. If any modifications are made to the luminaire, the person responsible for these modifications will be considered the manufacturer. The luminaire has two module designations: 24 455 K3 and 24 455 K4. Each module designation has different specifications for colour temperature, colour rendering index, module luminous flux, luminaire luminous flux, and luminaire luminous efficiency. The module connected wattage for this luminaire is 1.9 W for 24 455 K3 and 2.5 W for 24 455 K4. The ambient temperature range is between 25°C and 60°C. There is overvoltage protection installed in the luminaire according to DIN EN 61547. For additional protection against transients, it is recommended to use separate overvoltage protection components available on the manufacturer’s website at www.bega.com.

Product Usage Instructions

  1. Undo the hexagon socket head screws (wrench size 3 mm) through the opening in the luminaire housing until they stop. Lift the luminaire top.
  2. Disconnect the plug-connection of the LED connecting cable.
  3. Lead the mains supply cable through the cable entry of the luminaire base.
  4. Fix the luminaire base onto the mounting surface using the enclosed or any other suitable fixing material.
  5. Make the earth conductor connection and the electrical connection.
  6. To ensure the maximum service life of the electrical components, place the enclosed desiccant pouch in the luminaire. Remove the desiccant pouch from the foil packaging and place it in the position marked by the red information label before finally closing the luminaire.
  7. Make an earth conductor connection between the luminaire top and luminaire base.
  8. Connect the LED connection cable using a plug connector. Ensure that the gasket is correctly positioned.
  9. Install the luminaire top, press it on, and tighten the screws evenly.

Instructions for use

Application
House number luminaire made of aluminium alloy with crystal glass. For one up to three-digit numbers.

Product description

  • Luminaire made of aluminium alloy, aluminium and stainless steel
  • BEGA Unidure® coating technology
  • Safety glass, white
  • with 1-3 digit numbers
  • lettering height 100 mm
  • Silicone gasket
  • 2 elongated fixing holes
  • Width 6 mm · 177 mm spacing
  • 2 cable entries for through-wiring of mains supply cable ø 7-10.5 mm
  • Connecting terminal and
  • earth conductor terminal 2.5@
  • BEGA Ultimate Driver®
  • LED power supply unit
  • 220-240 V x 0/50-60 Hz
  • DC 176-264 V
  • BEGA Thermal Switch®
  • Temporary thermal shutdown to protect temperature-sensitive components
  • Safety class I
  • Protection class IP 65
  • Dust-tight and protection against water jets Impact strength IK06
  • Protection against mechanical
  • impacts < 1 joule
  •  – Safety mark
  • – Conformity mark
  • Weight: 1.6 kg
  • This product contains light sources of energy efficiency classes C

Safety
The installation and operation of this luminaire are subject to national safety regulations. Installation and commissioning may only be carried out by a qualified electrician. The manufacturer accepts no liability for damage caused by improper use or installation. If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.

Lamp

  • Module connected wattage: 1.9 W
  • Luminaire connected wattage: 2.5 W
  • Rated temperature: ta = 25 °C
  • Ambient temperature: ta max = 60 °C

24 455 K3

  • Module designation: LED-1090/830
  • Colour temperature: 3000 K
  • Colour rendering index: CRI > 80
  • Module luminous flux: 340 lm
  • Luminaire luminous flux: 75 lm
  • Luminaire luminous efficiency: 30 lm / W

24 455 K4

  • Module designation: LED-1090/840
  • Colour temperature: 4000 K
  • Colour rendering index: CRI > 80
  • Module luminous flux: 360 lm
  • Luminaire luminous flux: 80 lm
  • Luminaire luminous efficiency: 32 lm / W

Overvoltage protection

The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547. To achieve an additional protection against e. g. transients, etc. we recommend separate overvoltage protection components. You can find them on our website at www.bega.com.

Installation

Undo hexagon socket head screws (wrench size 3 mm) through the opening in the luminaire housing up to the stop and lift luminaire top. Disconnect plug- connection of the LED connecting cable. Lead the mains supply cable through the cable entry of the luminaire base. Fix luminaire base with enclosed or any other suitable fixing material onto the mounting surface. Make the earth conductor connection and the electrical connection. In order to guarantee the maximum service life of the electrical components, the enclosed desiccant pouch must be placed in the luminaire. Remove the desiccant pouch from the foil packaging and place it in the position marked by the red information label immediately before finally closing the luminaire. Make earth conductor connection between luminaire top and luminaire base. Connect the LED connection cable by means of a plug connector. Make sure that gasket is positioned correctly. Install the luminaire top, press-on and tighten screws evenly.

Cleaning · Maintenance

Clean luminaire regularly with solvent-free cleansers from dirt and deposits. Do not use high pressure cleaners.

Replacing the LED module

  • The designation of the LED module is noted on a label in the luminaire.
  • The light colour and light output of BEGA replacement modules correspond to those of the modules originally fitted.
  • The module can be replaced by qualified persons using standard tools.
  • Disconnect the system and open the luminaire. Please follow the installation instructions for the LED module.
  • Inspect and, if necessary, replace the luminaire gaskets.
  • Defective glass must be replaced.
  • Close the luminaire.

Spares

  • Spare glass with frame graphite: 25 000 036
  • Spare glass with frame silver: 25 000 037
  • LED power supply unit: DEV-0292/350
  • LED module 3000 K: LED-1090/830
  • LED module 4000 K: LED-1090/840
  • Gasket connection housing: 83 001 027

BEGA Gantenbrink-Leuchten KG
Postfach 31 60
58689 Menden
[email protected]
www.bega.com

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

BEGA User Manuals

Related Manuals