This device complies with port 15 of the FCC and Industry Canada license- exempt RSS standard(s). Operation is subject to the following two conditions:

  1. this device may not cause harmful interference, and
  2. this device must accept any interference received. including interference that may cause undesired operation.

FCC NOTE

The manufacturer is not responsible for any radio or TV interference caused by unauthorized modifications to this equipment. Such modifications could void the user’s authority to operate the equipment.

NOTE This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Port 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in o residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in o particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on o circuit different from that to which the receiver is connected.
  • Consult the dealer or on expenenced radio/TV technician for help

Important note: To comply with the FCC RF exposure compliance requirements, no change to the antenna or the device is permitted. Any change to the antenna or the device could result in the device exceeding the RF exposure requirements and void user’s authority to operate the device.

STOP

DO NOT RETURN THIS PRODUCT TO THE STORE

If you have any problems or questions, contoct our tech support team at, 1-800 654-8483, option 1 Monday-Friday, 8-5pm CST For the most up-to-date product support, accessories, electronic (PDF) format manuals and more. visit www.jascoproducts.com/support

WARNING

RISK OF FIRE RISK OF ELECTRICAL SHOCK RISK OF BURNS
CONTROLLING APPLIANCES:
EXERCISE EXTREME CAUTION WHEN USING Z-WAVE DEVICES TO CONTROL APPLIANCES. OPERATION OF THE Z-WAVE DEVICE MAY BE IN A DIFFERENT ROOM THAN THE CONTROLLED APPLIANCE, ALSO AN UNINTENTIONAL ACTUATION MAY OCCUR IF THE WRONG BUTTON ON THE REMOTE IS PRESSED Z-WAVE DEVICES MAY AUTOMATICALLY BE POWERED ON DUE TO T:=NED EVENT PROGRAMMING, DEPENDING UPON THE APPLI-ANCE, THESE UNATTENDED OR UNINTENTIONAL OP-ERATIONS COULD POSSIBLY RESULT IN A HAZARDOUS CONDITION. FOR THESE REASONS, WE RECOMMEND THE FOLLOWING: DO NOT USE Z-WAVE DEVICES TO CONTROL ELECTRIC HEATERS OR ANY OTHER APPLIANCES WHICH MAY PRES-ENT A HAZARDOUS CONDITION DUE TO UNATTENDED OR UNINTENTIONAL OR AUTOMATIC POWER ON CONTROL

NOT FOR USE WITH MEDICAL OR LIFE SUPPORT EQUIPMENT
z-Wave enabled devices should never be used to supply power to. or control the On/Off status of medical and/or life support equipment.

WARRANTY

JASCO Products warrants this product to be free from manufacturing defects for a period of two years from the onginal dote of consumer purchase. This warranty is limited to the repair or replacement of this product only and does not extend to consequential or incidental damage to other products that may be used with this product. This warranty is in lieu of all other warranties, expressed or implied. Some states do not allow limitations on how long on implied warranty lasts or permit the exclusion or limitation of incidental or consequential damage. so the above limitations may not apply to you. This warranty gives you specific rights, and you may also have other rights which vary from state to state. Please contact Customer Service at 800-654-8483 (option 11 between 7:30AM – 5:00PM CST or via our website (www.joscoproducts.com) if the unit should prove defective within the warranty period.

SPECIFICATIONS

ZW4002 Power: 120 VAC, 60 Hz. I Signal (Frequencyl 908.42 MHz. Maximum Loads: 1.5A No more than two identical fans to the switch. Not to exceed 1.5 Amp resistive load. CONTROLS FAN MOTOR ONLY. For use only with split capacitor or shaded pole ceiling fan motors. Range: Up to 100 feet line of sight between the Wireless Controller and the closest Z-Wave receiver module. Operating Temperature Range: 32-104° F 10-40° Cl For indoor use only. Specifications subject to change without notice due to continuing product improvement
Instruction

Tools you Will Need

Tools you Will Need

IMPORTANT! No more than two identical fans to the smart switch. Not to exceed 1.5 Amp resistive load. CONTROLS FAN MOTOR ONLY. For use only with split capacitor or shaded pole ceiling fan motors.

Getting To Know Your New Z-Wave Device

  • Turn ON/OFF and adjust Si speed levels manually or remotely via the Z Wave controller
  • Con be Included in multiple Groups and Scenes
  • May be used in single pole installation or with up to two GE Add-on switches in 3-woy or 4-way wiring configurations
  • Interchangeable Paddle switch — White & light almond paddle in package
  • Uses a standard, decorative size wall plate for single gang installations (wolf plate not included)
  • Blue LED indicates switch location in a dark room
  • Z-Wave Certified for simple pairing and integrated home automation
  • Screw Terminal Installation — requires winng connections for Line Hon, Load, Neutral, and Ground. Traveler wire required for 3-way or 4-way installation
    Wave Device

A. Top Rocker — Press & release to turn fan control on, press & hold increoses speed)
B. Bottom Rocker — (Press & release to turn tan control off press & hold to decrease speed)
C. Ground (Green/Bore)
D. Load – odd
E. Line Black’
F. Traveler ‘Red/Other)
G. Neutral twrntel

Single, Dual And Triple Gang Boxes
When instailing the In-wail Smart Fon Control in multiple gang boxes it may be necessary to break off one or both sides of the scored tabs on the front yoke. This does not affect the electrical rating of the switch (see specifications for details).
Triple Gang Boxes
Triple Gang Boxes

WARNING

Turn OFF the power to the branch circuit for the switch and fixture at the service panel. All wiring connections must be made with the POWER OFF to avoid personal injury and/or damage to the switch.

Multi-switch wiring
is tallations, please refer to Add-on Switch manual. Single switch wiring Before you start: you may wish to change the paddle color to match your wallplate or decore. Please proceed to section 5.

  1. Shut off power to the circuit at circuit breaker or fuse box
    IMPORTANT! Verify power is OFF to switch box before continuing.

  2. Remove wall plate 3. Remove the switch mounting screws 4. Carefully remove the switch from the switch box. DO NOT disconnect the wires.

Linking your device

  1. Follow the instructions for your Z-wave certified controller to include a device to the Z-v mart fon control sliAnitcin

  2. Once the controller is ready to include your device, press and release the top or bottom of tt-(rocker) to include it in the network.
    Note: Your controller may need to be within 10 feet of the device to be included.

  3. Once your controller has confirmed that the device has been included, refresh  the Z-wave n( nih to opitirnize nerformonCii
    Please reference the controller/gateway’s manual for instructions.
    Now you have complete control to turn your fixture ON/OFF and adjust fan speed level! according to groups, scenes, schedules and interactive automations programmed by If your Z-wove certified controller features Remote Access, you can now control your fixture u r Controller-nirn your mobile
    Note: To exclude and reset the device, follow the instructions provided by your Z-Wave control)

  4. There are up to five screw terminals on the switch, these are marked A. LINE (Hot) — Block (connected to power) B. Neutral — White C. LOAD — Black (connected to font 0 GROUND — Green/Bare E. TRAVELER — Red/Other (only used in 3-way insatallations) Match these screw terminals to the wires connected to the existing switch.

  5. Disconnect the wires from the existing switch. Be careful to label wires occording to the previous terminal connection. Observe Important Wiring Information
    IMPORTANT!: This Fan Control is rated for and intended to only be used with copper wire. Wire Gauge Requirements Use 14 AWG or larger wires suitable for at least BO’ C for supplying Line (HOT). Load. Neutral, Ground and Traveler connections. Wire strip length: For attachment to screw terminals: Strip insulation r i25mml For attachment using the enclosure’s holes: Strip insulation 5/8″116mm) UL specifies that the tightening torque for the screws is 14 Kgf-cm f12 ibf-in). 7 Connect the green or bare copper ground wire to the GROUND terminal.

  6. Connect the block wire that goes to the light to the terminal marked LOAD.

  7. Connect the black wire that comes from the electrical service panel (Hot) to the