OPTONICA 2009 Recessed Ceiling Ring Installation Guide
- June 9, 2024
- OPTONICA
Table of Contents
OPTONICA 2009 Recessed Ceiling Ring
Product Information
- Product Name: Unknown
- Importer: Prima Group 2004 LTD
- Address: Bulgaria, 1784 Sofia, Mladost 1, bl. 144, Ground Floor
- Contact Number: +359 2 988 45 72
Product Usage Instructions
Unfortunately, the above text extract does not provide any information regarding the product usage instructions. We recommend checking the user manual or contacting the importer for further assistance.
Installation
Manual SKU: 2009, 2010
- Switch off the power
- Ensure that the void depth is a minimum of 90 mm and the thickness of the ceiling is a maximum of 20 mm (Pic 1)
- Cut a hole using an appropriate tool according to the cut-out (Pic 2)
- Connect the wire of the drive to mains (110-220V) in a correct way, and put the driver into the ceiling properly (Pic 3)
- Push the spring clips upwards and fit them into the ceiling hole to ensure the product is sitting properly into the hole (Pic 4)
- Switch on the power if the above steps are done properly without any mistakes.
IMPORTER: Prima Group 2004 LTD, Bulgaria, 1784 Sofia, Mladost 1, bl. 144, Ground Floor; Phone: +359 2 988 45 72;
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>