Manual SKU: 2009, 2010

  1. Switch off the power
  2. Ensure that the void depth is a minimum of 90 mm and the thickness of the ceiling is a maximum of 20 mm (Pic 1)OPTONICA-2009-Recessed-Ceiling-Ring-FIG-4
  3. Cut a hole using an appropriate tool according to the cut-out (Pic 2)OPTONICA-2009-Recessed-Ceiling-Ring-FIG-5
  4. Connect the wire of the drive to mains (110-220V) in a correct way, and put the driver into the ceiling properly (Pic 3)OPTONICA-2009-Recessed-Ceiling-Ring-FIG-6
  5. Push the spring clips upwards and fit them into the ceiling hole to ensure the product is sitting properly into the hole (Pic 4)OPTONICA-2009-Recessed-Ceiling-Ring-FIG-7
  6. Switch on the power if the above steps are done properly without any mistakes.