BEGA 77017 In-Ground Luminaire Instruction Manual

June 13, 2024
BEGA

BEGA 77017 In-Ground Luminaire

Product Information

This product is a floodlight with symmetrical light distribution. It is designed for recessed mounting in compacted surfaces, paths, and places. It is specifically designed as a drive-over luminaire for vehicles with pneumatic tires. However, it should not be used for installation in road lanes where it may be exposed to horizontal strain due to braking, acceleration, and change of direction.

The installation and operation of this luminaire must comply with national safety regulations. Only qualified electricians should perform the installation and commissioning. The manufacturer does not accept liability for damage caused by improper use or installation. If any modifications are made to the luminaire, the person responsible for these modifications will be considered the manufacturer.

The luminaire can only be operated with an operating device that meets the requirements according to EN 61347-2-13. The maximum idle voltage of 60 V DC must conform to SELV or SELV equivalent.

Product Usage Instructions

  1. Prior to installation, ensure that a proper foundation capable of accepting a maximum pressure load of 2,000 kg (~20 kN) is provided by the customer. The pressure load is transferred to the foundation by the luminaire housing.
  2. The foundation must be carried out on a firm subgrade to ensure stability.
  3. The luminaire housing must be firmly concreted in to achieve firm stability.
  4. Ensure that the operating device used with the luminaire meets the requirements according to EN 61347-2-13 and has a maximum idle voltage of 60 V DC conforming to SELV or SELV equivalent.

Dimension

Instructions for use

Application

  • Floodlight with symmetrical light distribution.
  • For recessed mounting in compacted surfaces, paths, and places.
  • Drive-over luminaire for vehicles with pneumatic tyres.

Please note:

  • Luminaire must not be used for installation in road lanes, where the fixture is exposed to a horizontal strain due to braking, acceleration, and change of direction.

Product Description

  • Cover ring Luminaire housing made of stainless steel and cast stainless steel
  • Steel grade number 1.4301
  • Clear safety glass
  • Silicone gasket
  • Reflector made of pure anodized aluminum 2 mounting holes ø 5mm
  • Distance apart 80mm 1,8m water-resistant connecting cable 05RN8-F 2×1@ with implemented water stopper and 1.2m PVC cable conduit
  • Safety Class III 3
  • Protection class IP 68 10 m
  • Dust-tight and water pressure tight
  • Maximum submersion depth 10 m
  • Not suitable for permanent operation underwater
  • Pressure load 2,000 kg (~20 kN)
  • Impact strength IK10
  • Protection against mechanical impacts < 20 joule
  • Maximum surface temperature 20 °C (measured according to EN 60598 of a 15 °C)
  • Safety mark
  • Conformity mark
  • Weight: 0.6 kg
  • This product contains light sources of energy efficiency class(es) D, E

Safety

  • The installation and operation of this luminaire are subject to national safety regulations.
  • Installation and commissioning may only be carried out by a qualified electrician.
  • The manufacturer accepts no liability for damage caused by improper use or installation.
  • If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.

Please note:

  • The luminaire can only be operated with an operating device that fulfills the requirements according to EN 61347-2-13.
  • The maximum idle voltage of 60 V DC must conform to SELV or SELV equivalent.

Lighting technology

  • Half beam angle 44°

Lamp

  • Module connected wattage 1.2 W
  • Luminaire connected wattage 1.5 W
  • Rated temperature ta= 25 °C
  • Ambient temperature ta max =65 °C
  • When installed in heat-insulating material ta max=55 °C Voltage 24 V = DC

77 017K27

  • Module designation LED-0268/ 827
  • Color temperature 2700 K
  • Color rendering index CRI >80
  • Module luminous flux 215 lm
  • Luminaire luminous flux 136 lm
  • Luminaire luminous efficiency 90,7 lm /W

77 017K3

  • Module designation LED -0268/830
  • Color temperature 3000 K
  • Color rendering index CRI >80
  • Module luminous flux 220 lm
  • Luminaire luminous flux 139 lm
  • Luminaire luminous efficiency 92,7 lm/W

77 017K4

  • Module designation LED-0268/ 840
  • Colour temperature 4000 K
  • Colour rendering index CRI >80
  • Module luminous flux 225 lm
  • Luminaire luminous flux 142 lm
  • Luminaire luminous efficiency 94,7 lm/W

Notice prior to installation:

  • To accept the maximum pressure load of 2,000 kg (~20 kN) a proper foundation must be provided by the customer.
  • The pressure load is transferred to the foundation by this luminaire housing provided at the site.
  • The foundation must be carried out on firm subgrade.
  • In order to obtain a firm stableness, the luminaire housing must be firmly concreted.

Installation

  • A 24 V safety direct voltage source with a smoothed residual ripple of max. 10 % is required for the electrical connection of the luminaire – see accessories.
  • If other safety direct voltage sources are used, an upstream fuse (max. 6 A) must be provided by the customer.
  • Connect the black line with the negative and the red line with the positive terminal of the mains supply unit.
  • Position luminaire housing on the foundation (as described above) and fix it with enclosed or any other suitable fixing material.
  • To protect the luminaire connecting the cable from damage push the enclosed cable conduits over the cable.
  • Push the long corrugated tube (ø 20 mm) over the connecting cable up to the water stop.
  • Push the short corrugated tube (ø 25 mm) over the water stop up to the housing.
  • The electrical connection at the luminaire connecting cable must be carried out on-site according to the protection class and safety class.
  • We recommend using a distribution box 70 730 or 71 053.
  • After finishing the groundwork remove the protection foil from the luminaire cover.
  • Tighten the screws in the trim ring evenly crosswise.
  • Torque = 3Nm.

Please note:

  • Do not remove the desiccant bag from the luminaire housing.
  • It is needed to remove residual moisture.

Cleaning · Maintenance

  • After installation, the luminaire should first be cleaned. Building dust, residues from contact adhesives, paint splashes, and rust film must be completely removed. Never use high-pressure cleaners and cleaning implements made of normal steel, steel brushes, or steel wool because they cause extraneous rust to form.
  • When using stainless steel cleaners, please read the directions carefully.
  • Cleaning agents containing hydrochloric acid and chlorides should never be used.
  • We recommend cleaning the luminaires regularly

Replacing the LED module

  • The designation of the LED module is noted on a label in the luminaire.
  • The light color and light output of BEGA replacement modules correspond to those of the modules originally fitted. The module can be replaced by qualified persons using standard tools.
  • Disconnect the electrical installation.
  • Clean dirt and deposits from key openings of the screw head. Do not use a high-pressure cleaner. Open the luminaire and clean it. Use only solvent-free cleansers. Dismantle the
  • LED-board unit and disconnect the connecting cable at the terminal of the LED board unit.
  • Make the electrical connection of the new LED board unit.
  • Fix the LED board unit in the luminaire housing.
  • Check all screws and threads thoroughly and grease. Check the gasket and replace, it if necessary. The luminaire housing must be completely clean and absolutely dry. Close the luminaire. Torque = 3 Nm. Chemicals that have a corroding effect must not affect the luminaire housing.

Accessories

  • Power supply unit for LED luminaires 24 V DC
  • Safety transformer according to EN 61558/VDE 0570 part 2-6
  • 70 564 Power supply unit for 5-15 W
  • 70 465 Power supply unit for 10-25 W
  • 70 565 Power supply unit for 20-35 W
  • 70 566 Power supply unit for 30-50 W
  • 70 567 Power supply unit for 40-75 W
  • 70 169 Power supply unit for 70-150 W
    • 230 V y 50-60 Hz
  • 70 114 Power supply unit for 0-70 W
  • AC range: AC: 198-264 V y 50-60 Hz
  • DC range: DC: 176-275 V
  • The power supply units are also suitable for the operation of several LED luminaires. In this case, the maximum wattage of the power supply unit must not be exceeded.
  • 70 730 Distribution box for installation in soil with 7 cable entries Connection terminals 5 x 4@
  • For the accessories, separate instructions for use can be provided upon request.

Spares

  • Spare glass 14 000 916
  • LED module 2700 K LED- 0268/827
  • LED module 3000 K LED- 0268/830
  • LED module 4000 K LED- 0268/840
  • Reflector 76 001 124
  • Gasket 83 001 762
  • BEGA Gantenbrink-Leuchten KG
  • Postfach 3160
  • 58689 Menden
  • info@bega.com
  • www.bega.com

Documents / Resources

| BEGA 77017 In-Ground Luminaire [pdf] Instruction Manual
77017 In-Ground Luminaire, 77017, In-Ground Luminaire, Luminaire
---|---

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals