Product Information

  • Product Name: Schwimmbadleuchte (Swimming pool luminaire)
  • Model Number: 99 812
  • Recommended Installation Depth: 400 to 700 mm below the water surface
  • Compatib i lity: Intended for use underwater
  • Not suitable for brine pools, salt water pools or salt water electrolysis disinfection
  • Requirements: Installation must follow the guidelines set out in IEC 60364-7-702
  • Operating Device: Must be operated with a SELV (Safety Extra Low Voltage) operating device that meets the requirements of EN 61347-2-13
  • Maximum Open-Circuit Voltage: 30 V DC
  • Safety: Installation and operation must comply with national safety regulations. Only qualified electricians should perform installation and commissioning.
  • Maintenance: Use stainless steel tools for installation and maintenance work. Power supply unit must be operated outside the water. Ensure the cable length is sufficient for maintenance work above the water level.
  • Do not remove the desiccant bag from the luminaire housing as it is needed to remove residual moisture.

Product Usage Instructions

  1. Ensure the luminaire is installed at the recommended depth of 400 to 700 mm below the water surface in the swimming pool.
  2. Follow the guidelines outlined in IEC 60364-7-702 for correct installation, considering areas, ambient zones, etc.
  3. Avoid direct or indirect contact of the luminaire with baser foreign metals via swimming pool water, tools, etc.
  4. Do not use the swimming pool luminaire in brine pools, salt water pools, or with salt water electrolysis disinfection.
  5. Operate the luminaire only with a SELV operating device that meets the requirements of EN 61347-2-13. The maximum open-circuit voltage should be 30 V DC or SELV-equivalent.
  6. Alternatively, connect the luminaire to safety transformers in compliance with EN 61558/VDE 0570 Parts 2-6. The transformer must have an open-circuit voltage of less than 30 V DC and be approved for this type of installation.
  7. Ensure compliance with national safety regulations during installation and operation. Only qualified electricians should perform installation and commissioning.
  8. Use stainless steel tools for installation and maintenance work.
  9. Establish the connection on-site with the correct protection class and safety class for the luminaire.
  10. The power supply unit should be operated outside the water.
  11. When conducting maintenance work above the water level, ensure the cable length is long enough.
  12. Do not remove the desiccant bag from the luminaire housing as it is necessary to remove residual moisture.

Instructions for use

BEGA-99812-Swimming-Pool-Luminaire-1

Application
Recessed swimming pool luminaire for the illumination of public and private swimming and bathing pools with drinking water supply.

  • Pool with wall tiles
  • Pool with film lining
  • Metal or synthetic pool

Please note:

  • The luminaire is intended solely for use under water. Recommended installation depth 400 to 700 mm below the water surface
  • The requirements set out in IEC 60364-7-702 (e.g. areas, ambient zones, etc.) are mandatory for the correct installation of the luminaire.
  • Direct or indirect contact with baser foreign metals via swimming pool water, tools, etc. must be prevented.
  • For water in swimming pools and bathing pools in accordance with DIN 19643 and typical pool water temperatures (max. 40 °C), the luminaire can be used in water with a chloride ion concentration of up to 500 mg/l.
  • The swimming pool luminaire is not suitable for brine pools, salt water pools or salt water electrolysis disinfection.
  • A 24 V safety direct voltage source with a smoothed residual ripple of max. 10 % is required for the operation of the luminaire – see accessories.

Important:

  • The luminaire must only be operated with a SELV operating device that meets the requirements of EN 61347-2-13.
  • The maximum open-circuit voltage of 30 V DC must be SELV or SELV-equivalent.
  • Alternatively, the connection may be made to safety transformers in compliance with
  • EN 61558/VDE 0570 Parts 2-6 with an opencircuit voltage of < 30 V DC.
  • The transformer must be approved for this type of installation.

Safety

The installation and operation of this luminaire are subject to national safety regulations. Installation and commissioning may only be carried out by a qualified electrician. The manufacturer accepts no liability for damage caused by improper use or installation. If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.

Product description

  • Swimming pool luminaire made of stainless steel – material no. 1.4404 – electropolished
  • Safety glass, clear Silicone gasket
  • Reflector made of pure anodised aluminium 3m Connecting cable 05RN8-F 2×1@ suitable for laying underwater
  • Shell colour blue
  • Installation and luminaire housing with 1 screw cable gland each
  • Hose connection on installation housing for soft PVC protective hose ø 20 x 3mm
  • PVC protective hose for cable routing must be provided by the customer
  • BEGA article number 62000250
  • Safety class III 3
  • Protection class IP68 10m · Water pressure tight
  • Maximum submersion depth 10 m
  • Weight: 1.9 kg
  • This product contains light sources of energy efficiency class(es) D

Installation

Only stainless steel tools may be used for installation and maintenance work. The connection must be established on site with the correct protection class and safety class for the luminaire. The power supply unit may only be operated outside the water.
As maintenance work is carried out above the water level, make sure the cable is long enough.

Open the luminaire: Undo the screws and pull the luminaire housing out of the recessed housing. Loosen the countersunk screws and remove the flange ring from the recessed housing with both gaskets. A safety direct voltage source with a 24 V smoothed residual ripple of max. 10% is required for the electrical connection of the luminaire – see accessories. If other safety direct voltage sources are used, an upstream fuse (max. 6 A) must be provided by the customer.

  • Terminal +: Cable wire red
  • Terminal +: Cable wire black

Installation in concrete pools:

  • The recessed housing is poured when constructing the pool.
  • Calibrate the recessed housing on the formwork and secure it in place so that the cable entry is positioned on top.
  • Avoid contact with low-alloy or unalloyed steels.
  • Install the PVC protective hose provided by the customer, ø 20 x 3 mm (BEGA article number 62000250) onto the recessed housing using the enclosed hose clip until it is water-tight.
  • Route the PVC house on-site in such a way that the connecting cable can be inserted and the pool will not drain on its own.
  • If necessary, seal the PVC hose with an additional PG screw gland (BEGA article number 750215V)BEGA-99812-Swimming-Pool-Luminaire-2

Concrete pool with wall tiles

  • After removing the formwork, clean the installation housing, reinsert the screws so that the threaded holes are uncovered.
  • Attach the tiles up to the internal diameter of the installation housing.
  • Using a flange gasket, place the flange ring against the pool wall with the pin facing upward and securely connect with screws.
  • Do not use screws without sealing gaskets.
  • The second flange gasket is only required for pools with film lining and thin-walled pools.
  • If the screws are not long enough, use standard screws of sufficient length made of stainless steel, 1.4401, 1.4404 or 1.4571.
  • Spray the joint between the installation housing and the flange gasket with a suitable sealing compound.
  • Route the cable through the screw cable gland and the PVC protective hose.
  • Tighten the screw cable glands. Wind the cable around the luminaire housing.
  • Hang the luminaire housing up on the pin – screw cable gland facing downward – and secure in place with the screwdriver provided.BEGA-99812-Swimming-Pool-Luminaire-3

Concrete pool with film lining

  • After removing the formwork, clean the installation housing.
  • After installing the film in the pool, cut out the required opening and holes for screws.
  • The pool film must be positioned between the two flange gaskets.
  • Do not use screws without sealing gaskets.
  • Guide the screws through the holes of the flange ring directed upward – flange gasket, film, second flange gasket – and screw into place with the installation housing.
  • Tighten the screws securely.
  • Route the cable through the screw cable gland and the PVC protective hose.
  • Tighten the screw cable glands.
  • Wind the cable around the luminaire housing.
  • Hang the luminaire housing up on the pin – screw cable gland facing downward – and secure in place with the screwdriver provided.BEGA-99812-Swimming-Pool-Luminaire-4

Thin-walled pool made of metal or synthetic material

  • Calibrate the recessed opening with the flange ring on the pool wall.
  • The flange ring pin can be directed upwards for use as a template for marking the recessed opening ø145mm and the through holes ø5.5mm.
  • Make the recessed opening and drill holes in the pool wall.
  • The pool wall must be positioned between the two flange gaskets.
  • Using a flange gasket, place the recessed housing against the pool wall with the cable entry facing upward.
  • Using a flange gasket, place the flange ring against the pool wall from the inside with the flange ring pin facing upward and securely connect the entire unit with screws.
  • Do not use screws without sealing gaskets.
  • Install the PVC protective hose provided by the customer, ø20 x 3mm (BEGA article number 62000250) onto the recessed housing using the enclosed hose clip until it is water-tight.
  • Route the PVC house on-site in such a way that the connecting cable can be inserted and the pool will not drain on its own.
  • If necessary, seal the PVC hose with an additional PG screw gland (BEGA article number 750215V).
  • Route the cable through the screw cable gland and the PVC protective hose.
  • Tighten the screw cable glands.
  • Wind the cable around the luminaire housing.
  • Hang the luminaire housing up on the pin with the screw cable gland facing down and secure in place with the screwdriver provided.

Please note:

  • Do not remove the desiccant bag from the luminaire housing.
  • It is needed to remove residual moisture.

Lamp

  • Module connected wattage 8.2 W
  • Luminaire connected wattage 9.9 W
  • Rated temperature ta=25 °C
  • Ambient temperature ta max=65 °C
  • Voltage 24 V = DC

99 812K3

  • Module designation LED-1197/830
  • Colour temperature 3000 K
  • Colour rendering index CRI > 80
  • Module luminous flux 1380 lm
  • Luminaire luminous flux 890 lm
  • Luminaire luminous efficiency 89,9 lm/W

Light technique

  • Installation depth 400 to 700 mm below water level.
  • In order to achieve uniform luminance distribution for private swimming pools, we recommend an axis distance of 2.00-3.00 m.

Replacing the LED module

  • The designation of the LED module is noted on a label in the luminaire.
  • The light colour and light output of BEGA replacement modules correspond to those of the modules originally fitted.
  • The replacement must be carried out by a qualified person.
  • Disconnect the system from the power supply.
  • LED are high-quality electronic components! Avoid direct skin contact with the
  • LED light aperture during replacements.
  • Loosen the rotating part with the screwdriver provided.
  • Unhook the luminaire housing, unwind the cable and lift the luminaire housing over the edge of the pool.
  • To open the luminaire housing, unscrew the nuts.
  • Disassemble the reflector.
  • Replace LED module.
  • Follow the installation instructions for the LED module.
  • Replace the desiccant pouch inside the luminaire housing.
  • It is needed to remove residual moisture.
  • Check connecting cable and gaskets and replace as needed.
  • Clean and dry the lamp area, glass and sealing surfaces. Please note the relevant instructions under Cleaning · Maintenance.
  • Insert the reflector. Place the gasket with glass over the threaded bolts of the trim ring. Make sure the gasket is positioned correctly.
  • Place trim ring with gasket and glass on the luminaire housing.
  • Ensure that the screw cable gland and rotating part are positioned correctly (see drawing).
  • Close the luminaire housing tight with the trim ring.
  • Tighten the nuts uniformly in crosswise fashion.
  • Torque = 2Nm.
  • Wind the cable around the luminaire housing.
  • Hang the luminaire housing up on the pin and tighten the rotating part with the screwdriver provided.

Cleaning · Maintenance

  • Regular cleaning ensures long-lasting corrosion protection.
  • Only non-abrasive cleaning agents may be used to clean the luminaire.
  • Sponges, sponge wipes and fleece cloths made of synthetic material without abrasive grit may be used in the visible area.
  • Brushes with bristles made of natural or synthetic material can be used in the nonvisible area.
  • Metal cleaning tools (wire brushes, steel wool sponges, etc.) may not be used.
  • Prevent damage to the electropolished surfaces.
  • When carrying out cleaning work on the swimming pool, the luminaire must not come into contact with acids or cleaning agents that attack metal.
  • Only stainless steel cleaners suitable for the swimming area are permitted for the luminaires.
  • Do not use high pressure cleaners.

Accessories

BEGA Safety transformers according to EN 61558-2-6/VDE 0570, part 2-6

  • 70 564 Power supply unit for 5 – 15 W
  • 70 465 Power supply unit for 10 – 25 W
  • 70 565 Power supply unit for 20 – 35 W
  • 70 566 Power supply unit for 30 – 50 W
  • 70 567 Power supply unit for 40 – 75 W
  • 70 169 Power supply unit for 70 – 150 W
  • 70 223 Recessed distribution box for flush installation into floors or in walls. For the installation of cable for the swimming pool luminaire safety class III

For the accessories a separate instructions for use can be provided upon request.

Spares

  • Spare glass 14 000 352
  • LED module 3000 K LED-1197/830
  • Reflector 76 001 234
  • Gasket flange 82 000 294
  • Gasket glass 83 001 809

BEGA Gantenbrink-Leuchten KG · Postfach 3160 · 58689 Menden · info@bega.com · www.bega.com

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals