eurener ULTRA 400Wp N Type All Black Solar Panel Owner’s Manual

June 16, 2024
eurener

eurener ULTRA 400Wp N Type All Black Solar Panel

eurener-ULTRA-400Wp-N-Type-All-Black-Solar-Panel-fig-1

Product Information

Specifications

  • Manufacturer: European Experts in Residential Modules
  • Product Name: Ultra MEPV 120 cells – Eurener PV Module
  • Power Output : > 400Wp
  • Cell Type : N-type cell
  • Features:
    • Higher resistance to LID and LeTID
    • Back contact technology
    • Improved energy yield by reducing BB shadowing
    • Better temperature coefficient
    • Minimized thermal losses, improved efficiency
    • Easy to handle
    • Comfortable installation thanks to optimized area size
    • Premium aesthetic
    • Commercial and residential rooftop integration
    • Elegant design
    • Cells free from frontal metallization
  • Product Warranty: 20 Years (+5 years for Premium Partners)
  • Performance Warranty: Linear Warranty with 93% performance at 30 years
  • Market Standard Warranty: 80%

Product Usage Instructions

Installation
The Ultra MEPV 120 cells – Eurener PV Module is designed for both commercial and residential rooftop integration. Follow the steps below for installation:

  1. Select a suitable location on the rooftop with ample sunlight exposure.
  2. Ensure the surface is clean and free from any debris.
  3. Position and secure the PV module using appropriate mounting brackets.
  4. Connect the module’s junction box to the electrical system using the provided connector.
  5. Ensure all connections are properly secured and insulated.

Handling
The Ultra MEPV 120 cells – Eurener PV Module is designed to be easy to handle. Follow the guidelines below:

  • When transporting the module, ensure it is properly secured to prevent damage.
  • Avoid placing heavy objects on top of the module.
  • Handle the module with care to avoid scratching or damaging the surface.

Maintenance
To ensure optimal performance and longevity of the Ultra MEPV 120 cells – Eurener PV Module, follow these maintenance tips:

  • Regularly clean the surface of the module with a soft cloth or sponge.
  • Avoid using abrasive materials or harsh chemicals that may damage the module.
  • Inspect the module for any signs of damage or loose connections.
  • If any issues are detected, consult a professional for repair or replacement.

FAQ

  • What is the power output of the Ultra MEPV 120 cells – Eurener PV Module?
    The power output is greater than 400Wp.

  • What is the warranty period for this product?
    The product comes with a 20-year warranty, which can be extended to 25 years for Premium Partners.

  • What is the performance warranty?
    The performance warranty is linear, with a guaranteed 93% performance at 30 years.

  • Is the Ultra MEPV 120 cells – Eurener PV Module suitable for residential use?
    Yes, it is designed for both commercial and residential rooftop integration.

  • How should I handle the module during transportation?
    The module should be properly secured to prevent damage during transportation.

  • How often should I clean the surface of the module?
    It is recommended to regularly clean the surface of the module to remove any dirt or debris that may affect its performance. Frequency may vary depending on the environmental conditions.

PRODUCT FEATURES

  • N-type cell
    Higher resistance to LID and LeTID

  • Back contact technology
    Improved energy yield by reducing BB shadowing

  • Better temperature coeficient
    Minimized thermal losses, improved efficiency

  • Easy to handle
    Comfortable installation thanks to an optimized area size

  • Premium aesthetic
    Commercial and residential rooftop integration

  • Elegant design
    Cells free from frontal metallization

SPECIFICATION

**Dimension

**eurener-ULTRA-400Wp-N-Type-All-Black-Solar-Panel-
fig-2

Mechanical Specification

  • Solar cells 120 (6 x 20), N-Type monocrystalline silicon cells
  • Front Glass 3,2 mm thick tempered glass with high strength and ARC
  • Frame Black anodized aluminium
  • Junction Box IP68, 3 by-pass diodes
  • Connector Original MC4-Evo 2
  • Cable 1000 mm (±20%) length and 4 mm² section
  • Dimension 1727 x 1039 x 30 mm (±1%)
  • Area 1,79 m²
  • Weight and packaging 20 kg, 949 pcs-truck

Temperature Coeficients

  • Temperature coeficient of Isc (α) 0,045 %/°C
  • Temperature coeficient of Voc (β) -0,247 %/°C
  • Temperature coeficient of Pmax (γ) -0,290 %/°C
  • Temperature range -40 °C ~ +85 °C
  • Nominal operating cell temperature (NOCT) 43 ± 2 °C

STC: 1000 W/m2, module temperature 25ºC, AM 1,5

  • Nominal power. Pmax 400 Wp
  • Module efficiency 22,31 %
  • Short-circuit current (Isc) 12,05 A
  • Open-circuit voltage (Voc) 42,10 V
  • Maximum power current (Imp) 11,09 A
  • Maximum power voltage (Vmp) 36,10 V

NOCT: 800 W/m2, ambient temperature 20ºC, AM 1,5

  • Nominal power. Pmax 306,52 W
  • Short-circuit current (Isc) 9,72 A
  • Open-circuit voltage (Voc) 40,23 V
  • Maximum power current (Imp) 8,96 A
  • Maximum power voltage (Vmp) 34,23 V

Operating parameters

  • Maximum voltage 1500 V
  • Maximum series fuse rating. Ir 20 A
  • Power output tolerance 0 – +3%
  • Voc and Isc tolerance ±3%
  • Fire rating Class C (UL 790)
  • Protection class Class II (IEC 61140)
  • Hail resistance HW3/RG3
  • Mechanical loads Front load 5400 Pa, Back load 2400 P
    NOTE: Read the instruction manual of this product and follow the indications STC. Values are valid for: 1000W/m2, AM 1,5 and cells temperature of 25ºC. Measurement tolerance +/-3% (AAA Solar simulation -IEC 60.904-9-). All the information of this brochure may be amended without notice by Eurener.